Ultrasonic Wind Measuring System: Type WSS-L, Wsdi, Wsi
Ultrasonic Wind Measuring System: Type WSS-L, Wsdi, Wsi
• Sea-waterproof construction
This system offers the advantage of reading the measuring results from several locations on-board, e.g. at control desks
both on the bridge and on the bridge wings.
The displays are provided with data output for serial transfer of measuring values to the navigation computer of the ship
and/or to a personal computer via NMEA protocol.
The system indicates relative wind speed and wind direction. If indication of absolute wind speed and wind direction is
required, these values must be calculated separately.
Construction
The wind measuring system WSS-L consists of three components: A wind sensor, an interface box and 1-3 displays
for indication of wind speed and wind direction.
Placing: Ideally, the wind sensor should be placed far from large objects that might influence the
measuring results; however, in practice this is normally not possible on-board a ship.
The best result is achieved by placing the sensor at the top of a mast in the opposite
end of the superstructure.
Placing the sensor just above the superstructure is disadvantageous, especially where
the superstructure consists of wide side faces, over which the wind is forced. This may
result in turbulence, velocities and wind directions that are out of proportion to the
actual, undisturbed wind speed and wind direction.
Connections: The wind sensor is supplied with 2 metres fixed cable. From factory the cable is
connected to the sensor via a waterproof gland, and this must not be replaced by
another cable; the cable is extended by using a connecting box.
Installation cable: 4 x 0.75mm2 screened cable, e.g. UL2464 18AWG4C+AE, length max. 300 metres,
capacity max. 70nF between signal conductors.
Mounting: The sensor is delivered with a mounted steel tap. The tap is fastened on the mast using
e.g. a pole/tube with an inner ¾” RG thread.
The keyboard on the front of the display is provided with 3 push-buttons at the right for setting of:
Light intensity: The light intensity is adjusted to a suitable level by pressing the up arrow (▲)/down
arrow (▼) keys to increase/decrease the light intensity (8 levels).
Read-out in "m/s" or "knots": The "MODE" push-button is used to change the measuring unit for the wind speed
between reading in m/s or knots. A red LED at the centre of the display is lit, indicating
the selected measuring unit.
2
Technical specifications
Wind sensor type WSS-L
Sensor generally:
- Power supply: 12V DC ±20% (max. 1.1A)
24V DC ±20% (max. 0.6A)
- Temperature: Working range: 0...+60°C (WSS-L is without heater, which means that there is no
prevention from icing). Operation below 0°C is not weather dependent
Storage: -60...+70°C
- Relative humidity: 0…100%
- Pressure: 600…1100hPa
2
- Electrical connection: 2m 4 x 0.75mm screened cable type UL2464 18AWG4C+AE between sensor and
connection box (connection box is not included). The 2m cable is fixed on the
sensor
- Materials: Wind sensor housing: Polycarbonate +10% glass fibre
Mounting tap: Corrosion-resistant stainless steel
Weight: 0.8kg
- Protection: IP66, to EN 60529
- Electromagnetic compatibility: EN 61326: 1997 + Am 1:1998 + Am 2:2001
Communication port:
- RS485: NMEA 0183 protocol. For further information, see specific manual
4
Dimensions, wind sensor WSS-L
All dimensions in mm
127.0
114.0
198.0
149.8
82.4
49.5
¾” thread.
WSS-L
Dimensions, display
All dimensions in mm
100.8
144.0
144.0
135.5
m/s
kts m/s
kts
Max 40.0
PANEL CUT-OUT
TOL:±0.5
ALL DIMENSIONS IN MM.
136.0 + 1.0
WSDI
99.7
75.0
61.0
85.0 110.0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
5
Connections
WSS/WSS-L interface box WSI
Pin no. Function Note
1 Supply voltage - 24V DC supply for the interface box
2 +
3 NC
4 RS485 comm. A Wind speed and direction data from the wind sensor
5 B
6 GND
7 Power supply + 30V DC supply for the wind sensor
8 out NC
9 -
10 Wind speed TTL out Wind speed and direction data to the display type WSDI
11 Direction TTL out
12 Common GND
13 NC Do not connect
14 NC
15 NC
Display WSDI
Pin no. Function Note
AC Supply 220V AC or 110V AC To change from 220V AC to 110V AC or vice versa, see the
AC manual for WSS-L
GND EARTH The ship’s hull, it is not necessary to connect this terminal
1 AUX +5V DC External mode control For external dimmer and read-out of m/s or KTS in the display
2 0V Input from WSS Terminal 12 on the interface box, WSI
3 Wind speed interface box Terminal 10 on the interface box, WSI
4 Direction Terminal 11 on the interface box, WSI
5 Screen The cable screen. Do not connect the other end
A Signal NMEA NMEA0183 version 1.5 or 2.x-3.0
B Return
Screen The cable screen. Do not connect the other end
9 Mode shift m/s or KTS Read-out in the display
10 Dimmer ▼ Decrease illumination
11 Dimmer ▲ Increase illumination
6
Connection diagram
Connection
box 9 7 5 4 6
4 x 0.75mm²
cable lenght 1
18-32V
max. 300m 2
+
3
4
B A
Input
5
WSS
6
7
+
Supply
8 D = wind Direction
9 S = wind Speed
3 10
DS
DO NOT Display
4 11
WSDI
2 12
13
Not used
connect
14
15
The WSS box has to be mounted indoor,
recommended is close to the indicator.
LISTENER
220V AC ACCORDING TO
NMEA 0183 MULTIPLE
STANDARD LISTENERS
1 2 3 4 5 A B 9 10 11
+5V
0V
EARTH
MODE
wind Speed
SIGNAL
DIRECTION
SCREEN
RETURN
SCREEN
LISTENER
Display
E.g. VDR
WSDI
1
11
EXTERNAL
10 CONTROL
9 MODE
Order specifications
Type Power supply
Example: WSS-L 220V AC