100% found this document useful (6 votes)
7K views23 pages

HD BE Parameter List & Error

This document contains: 1) A list of 65 parameters that can be configured on an elevator control system including settings like language, number of floors, door type, and more. 2) Technical specifications for the control system including its dimensions, operating temperature range, input/output voltages, and security features. 3) An overview of the control system's features such as its LCD display, data recording, inspection mode, and group control capabilities. 4) Descriptions and screenshots of the control system's user interface including its opening screen, main screen, and menu system for navigating settings.

Uploaded by

Hedefsan Trade
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (6 votes)
7K views23 pages

HD BE Parameter List & Error

This document contains: 1) A list of 65 parameters that can be configured on an elevator control system including settings like language, number of floors, door type, and more. 2) Technical specifications for the control system including its dimensions, operating temperature range, input/output voltages, and security features. 3) An overview of the control system's features such as its LCD display, data recording, inspection mode, and group control capabilities. 4) Descriptions and screenshots of the control system's user interface including its opening screen, main screen, and menu system for navigating settings.

Uploaded by

Hedefsan Trade
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

www.hedefsan.

net  1 
 

PARAMETER LIST 
00  Language setting ( Turkish / English ) 
01   Lift type 
02   Command type 
03   Number of stops 
04   Number of basement 
05   Door type 
06   Busy time 
07   Lock waiting time 
08   Waiting at floor time 
09   High speed time 
10   Low speed time 
11   Max. Door time 
12   Go to park time 
13   Park stop 
14   Fire stop 
15   Direction arrow light 
16   Change password 
17   Cancel password 
18   Maintenance done 
19   Maintenance time 
20   Error list 
21   Digital setting 
22   Special door setting 
23   Rescuer (Active / Cancel 
24   Dublex setting 
25   Call transfer 
26   Phase protection (Active / Cancel) 
27   Ptc (Active / Cancel) 
28   Car serial board (Active / Cancel) 
29   Automatic door open time 
30   Single door full automatic 
31   Rp delay   For roped VVVF and hydraulic elevators 
32   Inspection movement type 
33   Early door opener 
34   Star triangle   For hydraulic elevators 
35   Motor valve time    For hydraulic elevators 

 
01 Ocak 2017
www.hedefsan.net  2 
 
36   Door open leveling 
37   Buttom stop 
38   Early door opener way 
39   Target Floor display flash 
40   Display output 
41   Maximum car call  
42   Safety delay 
43   Maximum car speed 
44   Counter type 
45   Go distance after JF 
46   Photocell time 
47   Krc (Active / Cancel) 
48   Encoder divider 
49   Automatic door at park 
50   Position reset 
51   Regulator Monitoring / Brake Monitoring 
52   Floor landing correction 
53   Floor ascent correction 
54   Short floor way 
55   Long floor way 
56   Gong sound 
57   First setup 
58   Lcd contrast 
59   UCM test 
60   Interval speed 
61   Kak‐sak time 
62   Cabin light from card 
63   Delete automatic recording 
64   Input assignment 
65   Factory setting 
 

 
01 Ocak 2017
www.hedefsan.net  3 
 
TECHNICAL SPECIFICATIONS 
Dimensions 
267× 201 × 35 
 Lenght × Width × Hight (mm) 
Operation Temperature  ±0 ‐ +60 °C 
Protection Class  IP20 
Humidity  %95 
Main Control Inputs  3 x 380V, 50Hz, N 
Control Feed Voltage  24 ± 5 Vdc 
Power Usage  Maks. 400mA 10W, for 24VDC  
230Vac max. For hydraulic elevators in 
Security Circuit Voltage 
emergency descent 24Vdc   
Control Signal Inputs  24 ± 5 Vdc 
24 ± 5 Vdc  
Control Signal Outputs 
Short‐Circuit Protection 
 

MAJOR FEATURES 
 2‐line 16‐character LCD display and 4 button keyboard 
 RS‐485 serial communication for group operation 
 RS‐485 serial communication for serial system connection with cabin 
 Recording the last 20 errors  
 Including door bridging safety circuit  
 Including phase sequential motor protection circuit 
 Including in‐ and output control of 2 automatic doors 
 Short circuit protected digital and signal outputs 
 Setting of indicator possible via menu: 7‐segment, Binary and Gray code 
 UPS support for emergency descent on hydraulic elevators. 
 

   

 
01 Ocak 2017
www.hedefsan.net  4 
 
 
OPENING SCREEN 
When you power on, you can view the software version and serial 
HD BE 
number of the card on the opening screen. After a couple a seconds 
Ver:1.0 SerialNo:030485  the screen changes to the MAIN SCREEN. 
 

MAIN SCREEN 

Waiting for Call…  Here it shows the feed voltage (100) and the number of the floor 
D:15     +25.4V  where the elevator is at the present. 

Waiting for Call … 
If encoder is selected as counter type it looks like this. 
D:15     +25.4V   65000 
 

INSPECTION FROM BOARD 
Çıkış butonuna 2 saniye basılı tutarak asansörü karttan revizyon 
Inspection from Board 
konumuna alabilir daha sonra yukarı ve aşağı butonları ile hareket 
D:15         +24.0 V  ettirebilirsiniz. 
 

RECORDING FROM BUTTONS 
Hold down both the up and the down button during one second, the 
Manuel Record ==> 10 
manual recording screen will appear. Select the floor number and press 
D:15         +24.0 V  enter. You can easely send your elevator to any floor you like. 
 

 GROUP WORKING DISPLAY 

 
01 Ocak 2017
www.hedefsan.net  5 
 

Group (ABCDEF) P‐A 
The status of 6 panels in group operation is shown as:   
D:15         +24.0 V 

A‐B‐C‐D‐E‐F Is the ID name of the control panels that are defined in 
group. 
Indicates wether the control panel with communication 
A‐a  is included in the group operation. (Lowercase means 
that it is excluded from the elevator group)  
Indicates the ID name of the master of the control 
P‐A  panels. 
Indicates a none existing control panel or a control panel 
‐‐  without communication.  
』  Shows the speed of the communication. 
 

ENTER MENU 
To enter the menu press and hold the ENTER button for 3 seconds. If 
00: Language setting  no password is defined for an entry permit (0000: initial password), 
English   then the display shows the first parameter and the text "LISAN / 
LANGUAGE" will appear. 
 

PASSWORD MENU 
If you previously defined a 
password, enter your 
If you previously defined a password, enter your password using the 
password using the UP and 
UP and DOWN buttons correctly. Then press the ENTER button to 
DOWN buttons correctly. 
confirm the password. 
Then press the ENTER button 
to confirm the password. 
If your password is entered correctly the first parameter will appear on 
the screen. If entered incorrectly, the "INCORRECT PASSWORD!" 
warning will appear and the card will return to the main screen. The 
card does not block when you enter the wrong password. But you can 
contact us for password help if you communicate the serialcode. Use 
the UP and DOWN buttons to move between the parameters of the 
program. And use the ENTER and EXIT buttons to change the parameter 
value. After changing the parameter value with the UP and DOWN 
buttons, record by pressing the ENTER button. Or you can press cancel 
to return to the old setting.  
 

 
 
01 Ocak 2017
www.hedefsan.net  6 
 
EXIT MENU 

Exit menu  Press EXIT button to exit the menu. By pressing ENTER when you see 
       (ENTER)  “EXIT MENU” you can exit the menu screen. 

LANGUAGE SETTING 

00: Language setting  Turkish  English  Russian 


English  In this parameter, you can choose that languages. 
 

LIFT TYPE 

01: Lift type  
Asansörünüzün tahrik tipini bu parametre ile ayarlayabilirsiniz. 
Double speed 
Continous gear (with asynchronous machine) and gearless (with 
Roped VVVF 
synchronous machine) 
Hydraulic  Choose this setting for hydraulic elevators. 
 

COMMAND TYPE 

02: Command Type 
Set your elevator command type here. 
Simple Command 
The cabin and floor buttons are connected parallely. No other except 
Simple Command 
the one registration is kept in memory. 
The cabin and floor buttons are connected parallely. Registrations are 
Mixed Collective 
kept in memory. 
The cabin and floor buttons are connected seperately. Cabin 
Down Collective  registrations are collected from both sides. Floor calls are collected 
when when cabin moves in downward direction. 
Cabin registrations and the up and down buttons at the floors are 
Full Collective (both ways)  connected seperately. Cabin registrations and floor calls are collected 
in appropriate manner of movement direction. 
If the number of stops in a duplex elevator is more then 9 stops, this 
Duplex Special 
setting is used for a full collective command.   

 
01 Ocak 2017
www.hedefsan.net  7 
 
 

NUMBER OF STOP 

03: Number of Stops 
Set the number of stops (maximum 16) here. 
D:16 
 

NUMBER OF BASEMENT 

04: Number of basement 
Set the number of basement here. 
01 
If the elevator is down collective, the floors that are under the basement that is set, it will be up 
collective. 
Note: Used in command types except for down collective. 
 

DOOR TYPE 

05: Door Type 
Set the open‐close signal type for automatic doors here. 
Swing Door 

 Swing Door  Only for elevators that have no automatic door. 

Aut. Unlimited  Only used for elevators with automatic unlimited cabin doors. 

Aut. limited  Only used for elevators with automatic limited cabin doors.  

Full Aut. Unlimited  Only used for elevators with full automatic unlimited cabin doors. 

 Full Aut. limited  Only used for elevators with full automatic limited cabin doors. 
According to the EN 81‐1/2 standarts in states of emergency stop, revision and take back automatic 
doors must remain stationary. 
 

 
01 Ocak 2017
www.hedefsan.net  8 
 
 

BUSY TIME 

06: : Busy Time 
Set the cabin light delay here. 
006 Seconds 

5 ‐ 20 Seconds  Set the cabin light delay time between the minimum and maximum. 

According to the EN 81‐1/2 standards it is not allowed to bypass the cabin light delay. 

On elevators with simple cımmand (non‐collective) this parameter must be equal to the ‘’WAIT 
AT STOP’’ time. And the busy time must be at least 2 seconds.  
 

LOCK WAITING TIME 

07: Lock waiting   Set the maximum time to wait for the door lock signal (140) after 
008 Seconds  getting the door closed signal. 

8 ‐ 30 Seconds  Set the lock waiting time between the minimum and maximum. 
 

WAITING AT STOP TIME 

08: Waiting Time at Floor  Set the waiting time before going to other registrations while 
008 Seconds  collecting. 

3 ‐ 15 Seconds  Set the waiting time at floor between the minimum and maximum. 

According to the EN81‐1 and EN 81‐2 standards, elevators( menuel doors) when the car reached 
to the stop, it has to wait 2 seconds before moving again. 

On elevators with simple command (non‐collective) this parameter must me equal to the “CABIN 
LIGHT” time and must be at least 2 seconds. 
 

 
01 Ocak 2017
www.hedefsan.net  9 
 
 

HIGH SPEED TIME 
Set the maximum time of cruising between 2 stops. If this time should 
09: : High speed time 
be exceeded, the system automatically stops the movement of the 
015 Seconds  cabin and blocks it. 

5 ‐ 120 Seconds  Set the fast cruising time between the minimum and maximum. 
 According to the EN81‐1 / 2 standards motor operation time work must not exceed the smaller 
of the following; 
 
 45 seconds 
 Longest cruising distance +10 seconds 
 If longest cruising distance is less than 10 seconds, the timeout should be at least 20 seconds 
 

LOW SPEED TIME 
Set the maximum time of slow cruising from the moment it meets the 
10: Low speed time 
stopper of the target floor. If this time should be exceeded, the 
015 Seconds  system automatically stops the movement of the cabin and blocks it. 

5 ‐ 60 Seconds  Set the slow cruising time between the minimum and maximum. 
 

MAX. DOOR STILL OPEN ERROR TIME 
If after the time set in this parameter the door is not closed yet the 
11: Max. Door time 
control panel will go out of service. It is possible to choose to bypass this 
015 Seconds  function. 
Set the time for passing the door still open error between the minimum 
15 ‐ 250 Seconds 
and maximum. 
 

GO TO PARK TIME 

12: Go to park time  
Set the waiting time before going to park stop. 
015 Seconds 

0 ‐ 250 Seconds  Set the waiting time between the minimum and maximum. 
 

 
01 Ocak 2017
www.hedefsan.net  10 
 
 

PARK STOP 

13: Park stop  Set the park stop here. When elevator pauses its operation,it goes to 
05  this floor and waits with open doors. 

FIRE STOP 
Set here the fire stop. When Fire input (at SIDE) is active the elevator 
14: Fire Stop  goes to the defined floor directly and waits with its doors open. 
01  Elevator will return to normal operation mode when fire signal is 
over. 
This is the minimum and maximum time that is waited before going to 
0 ‐ 250 Seconds 
park stop.  
Cancel  Fire stop is not defined in the system. 
1 – 16   Fire stop is defined in the system. 
 

ARROW FLASH 

15: Arrow flash 
Set here the flashing direction arrow while the elevator is  in motion. 
Active 

ACTIVE  Direction arrow flashes in direction of movement. 

CANCEL  Direction arrow  light up constantly in direction of movement. 
 

CHANGE PASSWORD 

16: Change password  Set or change the password code here.  

1_0_0_0_0  If the display looks like this, the password is activated. 
 

CANCEL PASSWORD 

 
01 Ocak 2017
www.hedefsan.net  11 
 

17: Cancel password  Cancel the password code here. 

0_0_0_0_0  If the display looks like this, the password is canceled. 
 

MAINTENANCE DONE 

18: Maintenance done  Reset here the maintenance period. 

Maintenance done !  You can reset your maintenance time by pressing the enter key. 
 

MAINTENANCE TIME 
For every day the card operates the value of this parameter drops by 
one. For example, if it is set for 45 days, this parameter will show a 
19: Maintenance time  value of 15 when 30 days have passed. After 45 days the value will be 
0. 
45 ‐ 250 days  Set the maintenance time between the minimum and maximum. 
 

ERROR LIST 
Here you can view the last 20 errors with their stop names, starting 
20: Error list 
with the last error. When reaching the first error, an option to delete 
817 Doesn’t come  the errors pops up. You can delete all errors by pressing ENTER. 
 

 
01 Ocak 2017
www.hedefsan.net  12 
 
DIGITAL SETTING 

21: Digital setting 
When the floor number is blinking, set the floor number with the UP‐
DOWN buttons till you come to the floor number you want to change. 

16
Press the ENTER button and next you will see the digits blinking. Set 
the value you like. When finished exit with the exit button. Or if you 
want to set another stop/floor, press the enter button, when floor 
number is blinking, repeat the steps. 

Indicator type  Outputs that can be selected 

 ‐4, ‐3, ‐2, ‐1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 ,11, 12, 13, 14, 15, 16  
7 Segment indicator 
 A, B, C, D, E, F, H, J, L, N, O, P 
 

SPECIAL DOOR SETTING 
Set the floor at which you want to open the automatic A and B doors. 
22: Special door setting  When floor number is blinking, change the floor number with the  UP‐
DOOR:01             A‐B  DOWN buttons till you come to the floor number you want to change. 
Press the ENTER button and next you will see the door setting 
blinking. Determine the door setting again by using the UP‐DOWN 
A‐B 
buttons. 
 

RESCUER 
With stepless gear (asynchronous machine) and gearless 
23: Rescuer  (synchronous machine) hydraulic elevators the rescue‐type is 
determined here. 
 

DUPLEX SETTING 

24: Duplex setting   Set here the group ID of the control panel during the group operation. 
A panel  Group IDs A, B, C, D, E, or F can be used. The identity of each lift must 
be different. Priority when in the same distance is given to the 
elevator with the lowest group identity. 
A‐B‐C‐D‐E‐F 
 

 
01 Ocak 2017
www.hedefsan.net  13 
 
CALL TRANSFER 
If the elevator operates in group and external calls are connected to a 
25: Call transfer  
single panel, this paremeter should be ACTIVE, in other cases it 
Active  should be cancelled. 
 

PHASE PROTECTION 

26: Phase production  
Set the phase sequence or deactivate the phase here. 
Phase sequenced 

Out of Order  Deactivate phase 

Phase unsequenced  Activates phase without sequence 

Phase sequenced  Activates phase sequenced 
 

PTC 

27: Ptc 
Choose the PTC motor thermistor input setting. 
Active 

ACTIVE  Activates it. 
CANCEL  Deactivates it. 
 

CABIN SERIAL CARD 

28: Cabin Serial Card   Activate this parameter when the serial communication card is 
Active  connected.   

 
When this parameter is cancelled the serial communication continues but only the floor inputs and 
other inputs will be canceled. 
 
 

AUTOMATIC DOOR OPEN TIME 
29: Automatic door open 
time  Set the time from opening till closing of the automatic door. 
15 Seconds 

 
01 Ocak 2017
www.hedefsan.net  14 
 
05 – 20 Seconds  Set the door open‐close time between the minimum and maximum. 
 

SINGLE DOOR FULL AUTOMATIC 

30: Single door full  On elevators with swing doors, set this parameter when there’s only 
automatic  one full automatic door. 

RP DELAY 
It could be demanded with roped VVVF systems to delay the fall of 
31: RP Delay  the main contactor. In such cases, the RP delay of the relay output is 
02600  set by this parameter. With hydraulic elevators it is used as motor 
delay.  
00000 – 25000 Miliseconds  Set the contactor delay time between the minimum and maximum.. 
 

REVISION MOVEMENT TYPE 
32: Revision movement 
type  Set the movement type of the up and down limit switches in revision. 
Until Limit switch 
When limit switches are enabled the elevator will stop before reaching 
Until Limit switch 
its floor. 
Until Floor  Even when limit switches are enabled the elevator will go to its floor. 
Until Stop   This parameter uses only for test. 
 

EARLY DOOR OPENER 
Activate here the early door opener function. (for roped VVVF and 
33: Early door opener   hydraulic elevators)  
Active   It is not possible to execute a levelling from inside cabin before 
activating this parameter. 

 
01 Ocak 2017
www.hedefsan.net  15 
 
ACTIVE  Early door opener activated. 
CANCEL  Early door opener canceled. 
For the early door opener, the movement of the cabin while the door is open is resticted to the 
door opening area and restricted to a speed of 0,15 m/s. This is permitted under the control of 
the door bridging circuit on the HD BE. 
 

STAR TRIANGLE 
Set the waiting time after finishing the star connection of the motor 
34 Star triangle  
when rising and before continuing to the triangle connection in a 
01000  hydraulic system. 
Set the passing time to the triangle connection between the minimum 
00000 – 25000 Miliseconds 
and maximum.  
 

MOTOR VALVE TIME 

35: Motor valve time  
The delay of the valves while rising in a hydraulic system is set here. 
00100 

00000 – 25000 Miliseconds  Set the valve delay time between the minimum and maximum. 
 

OPEN DOOR LEVELING 
Activate here the open door releveling.  
36: Door open leveling  (For roped  VVVF and hydraulic elevators) 
Active   It is not possible to execute a levelling from inside cabin before 
activating this parameter. 
ACTIVE  Releveling is activated. 
CANCEL  Releveling is canceled. 
 

 
01 Ocak 2017
www.hedefsan.net  16 
 
BUTTOM STOP 
This parameter is used only in group operation. If there’s a difference 
37: Bottom  stop  in stops of the elevators, then this parameter is used to set the 
2  bottom floor stop of the elevator that is different.  For this setting, 
the number of stops of the elevators in group operation must be the 
same in the menu. For example, in a duplex system with 10 stops, 
when elevator A doesn’t service the bottom floor and only elevator B 
 
does: Both elevators must be set to 10 stops and the bottom floor 
stop of elevator A must be set up as 2.   
 

EARLY DOOR OPENER WAY 
For the start of the early opening of the automatic door, set here the 
38: : Early door opener way  number of milimeters before reaching the floor. 
080 
 Only applicable when early door opener is activated. 
Set the early door opener distance between the minimum and 
040 – 150 Milimeter 
maximum. 
 

TARGET FLOOR DISPLAY FLASH 
39: Target floor display  When this parameter is activated, the floor display flashes the 
flash  number of the target floor at each stop while moving down or up the 
Active  shaft.  

ACTIVE  Target floor display flash is activated.  
CANCEL  Target floor display flash is canceled. 
 

DISPLAY OUTPUT 

40: Display output   Set the display output of the HD One X S controller card and HD Seri 
7 segment output  card. 

7 Segment output  Normal output. 
Gray code output  Gray code output. 

 
01 Ocak 2017
www.hedefsan.net  17 
 
Binary code output  Binary code output. 
 

MAX. CALL REGISTRATION 

41: Max. Car Call Registration  Set the maximum amount of calls that can be registrated from within 
cabin. When this number is reached it stops registrating any calls 
08  from within cabine. 

01 ‐ 16  Set the number of stops between the minimum and maximum. 
 

SAFETY DELAY 

42: Safety delay  Here set up the time to delay the movement of the elevator after the 
0120  safety circuits 130 and 140 signals. 

0000 – 1000 Milisecond  Set the safety delay time between the minimum and maximum. 
 

CAR MAX.SPEED 

43:Car max.speed   Selecting car max.nominal speed in this parameter 
100  For example:For  1 m/sd  100. 

COUNTER TYPE 

44: Counter type  
Set here your selection of the elevator floor sensor. 
Encoder type 

ML1 & ML2   ML1‐ML2 counter suitable for A3 standards (for Hydraulic) 
Encoder counter  It is uses shaft learning and suitable for A3. 
Encoder 141 & 142  It is uses shaft learning and leveling from 141,142 
 

 
01 Ocak 2017
www.hedefsan.net  18 
 
GO AFTER JF 

45:Go after JF  
This parametere uses for finding floor level at 141,142 leveling 
0100 
If the car level up or down then you can set leveling as incerase or 
000 – 200 Milisecond 
lower the value. 
 

PHOTOCELL WAITING TIME 

46: Photocell waiting time  Set the time of waiting for the photocell signal to close the door after 
003 seconds  the opening of the automatic door. 

01 – 05 seconds  Set the photocell waiting time between the minimum and maximum. 
 

47 RESERVED 

47 RESERVED  47 RESERVED 

47 RESERVED  47 RESERVED 

47 RESERVED  47 RESERVED 

ENCODER DIVIDER 

48: Encoder divider  Enter here the result of the calculation according the elevator speed, 
026  the number of encoder pulse and engine speed. 

Scan the QR code  
To calculate the Encoder Divider Rate Hedefsan has developed  to open the app. 
an  app available on Google Play Store. 

Without the app you can calculate the encoder divider rate by applying this formula:   

Calculation: Motor speed  X Encoder pulse number / 60 / Elevator speed = Enter result in the 48th parameter.  

Example: 1500 X 1024 / 60 / 1000 =26 
 

 
01 Ocak 2017
www.hedefsan.net  19 
 
AUTOMATIC DOOR AT PARK 

49: Aut.Door.At.Park  Set the open or closed position of the automatic door when waiting 
Wait closed  at park. 

Waiting Open  Car waiting open door at park stop. 
Waiting Close  Car waiting close door at park stop. 
 

POSITION RESET 
Even when there’s a power blackout the controller card will 
50: Position reset   remember its last position. But in some special cases when the power 
Cancel  returns, a position reset may be wanted. In that case the elevator will 
go until it reaches the 817 limit switch of the bottom floor. When it 
reaches the bottom floor, the floor counter will reset.  For example: 
  with systems that have battery charged rescuers, this parameter can 
be activated to reset the position. 
ACTIVE  Position reset is activated. 
CANCEL  Position reset is canceled. 
 

REGULATOR MONITORING / BRAKE MONITORING 
51:Regulator & Brake 
Monitoring  
Cancel  Regulator and Brake monitoring can be active in this parameter. 

REGULATOR MONITORING  Regulator monitoring is active. 
BRAKE MONITORING  Brake monitoring is active. 
CANCEL  Regulator and Brake monitoring is cancel. 
 

FLOOR LANDING CORRECTION 
 
01 Ocak 2017
www.hedefsan.net  20 
 
If the elevator counter type is encoder, then the floor landing 
52: Floor landing correction 
correction is set here. The setting is done with – mm if the elevator is 
[16]  =                000  too high and with + mm if it is too low.   
 

FLOOR ASCENT CORRECTION 
If the elevator counter type is encoder, then the floor ascent 
53:Floor ascent correction 
correction is set here. The setting is done with – mm if the elevator is 
[16]  =                000  too high and with + mm if it is too low.   
 

 SHORT FLOOR WAY 

54: Short floor way  Adjust here the slowing down distance when elevator moves one 
140 cm.  floor distance.( This parameter uses at Encoder counter systems.) 

100 – 180 cm  Minimum ve Maksimum deceleration distance. 

 
 LONG FLOOR WAY 
Adjust here the slowing down distance when elevator moves more 
55:: Long floor way 
then a floor distance.(  This parameter uses at Encoder counter  
140 cm.  systems .) 

100 – 180 cm  Minimum ve Maksimum deceleration distance. 

 
 GONG SOUND 

56: Gong sound   FIRST SETUP 
It activates or cancels the gong sound in serial communication. 
Cancel 
57: FIRST SETUP 
This parameter uses for shaft learning. After shaft learning take it cancel  
Cancel 
 

 
01 Ocak 2017
www.hedefsan.net  21 
 
 
LCD CONTRAST 

58:LCD contrast 
Adjust here the LCD contrast. 
035 
 

 
UCM TEST 

59:UCM Test  You can make ucm tes in this parameter. 

 
 INTERVAL SPEED 

60: Interval speed  Set here the interval speed. 

 
KAK – SAK TIME 

61:Kak – Sak time  KL FROM BOARD 
You can adjust passing rescuer mode time in this parameter.. 
007 Second 
62:KL from board  With this parameter, if the cabin lamp is set as active or canceled from the 
Cancel  control card, the KL relay is defined as the out relay at floor . 

 
 DELETE AUTOMATIC RECORDING 
63:Delete automatic  With this parameter, incorrectly given calls from the cabinet button can 
INPUT ASSIGNMENT 
record  be deleted by holding down the button. In addition, in‐cab records 
Cancel 
64:Input assignment  automatically delete all in‐cab records when there are 2 stops in or out 
With this parameter, different features can be defined for assignable 
PI4‐PI5  inputs on the mainboard 

KRC, SGH, RFI, K20, DTS, 817, 818, ML1, ML2, 141, 142, 500, 501, DEP, 
PI4  YNG can defined. 

 
01 Ocak 2017
www.hedefsan.net  22 
 
KRC, SGH, RFI, K20, DTS, 817, 818, ML1, ML2, 141, 142, 500, 501, DEP, 
PI5  YNG  can defined . 
 

FACTORY SETTINGS 

64: Factory settings  Here you can cancel your settings and return to factory settings. 

ERROR LIST
01   Stop Interrupted  120 circuit cuts in motion. 
02   Plug Interrupted  130 or 135 circuit cut in motion 
03   Lock Interrupted  136 or 140 circuit cut in motion 
04   KRC Error  Motor contactor must be adherent situation. 
05   PTC Error  Motor temperature is above the required value. 
06   Power Off  Check the main power. 
07   High Speed Long   The elevator did not reach to stop at high speed. 
08   Low Speed Long  The elevator did not reach to stop at low speed. 
09   Lock Nor Realised  Check door locks. 
10   Plug Not Realised  Check door plug contacts. 
11   There is not Ksr  Check the position of the 817 and 818. 
12   R‐Phase Error  Check R Phase. 
13   S‐ Phase Error  Check S Phase. 
14   T‐ Phase Error  Check T Phase. 
15   None Phases  Check all phases. 
16   Low Voltage  Check  24VDC feed input.  
17   None Enc. Pals  Check motor or regulator encoder. 
18   Leveling Long  Check leveling speed. 
19   None Lower Limit  Check 817 position. 
20   None Upper Limit  Check 818 position. 
21   Lock Shor Circuit  Check door lock. Seperate short circuit in the shor circuit situation. 
22   Reg.C.Released  Check regulator coil. 
23   Phase.C. Error  Check phase collocation. 
Communication  Check S1A‐S1B communication cable. 
24  
Error 
25   Inverter Error  Check SHG position. ”on the VVVF elevator ” 

 
01 Ocak 2017
www.hedefsan.net  23 
 
26   H. Unit Error  Check SHG position. ”on the Hydraulic elevator ” 
PERMANENT ERRORS 
01  M. Brake Error  Check motor brake. 
Involuntary  The elevator moved uncontrollably. 
02 
Movement 
03  ML Short Circuit  Check ML1 and ML2 distance position. 
Reverse Direction  Check the movement direction of the elevator. 
04 
Movement 
Regulator Coil  Check the elevator regulator coil. 
05 
Error 
To erase the above permanent errors, it will be sufficient to hold down the "ÇIKIŞ" button on the 