0% found this document useful (0 votes)
18 views1 page

Quiz 1: Three Phase Circuits: (10 Marks)

This document contains 7 questions about analyzing three phase circuits. The questions cover topics like calculating phase current, line current, power factor, apparent power, active and reactive powers for a delta connected load. Other questions involve finding circuit parameters for a balanced delta load, calculating capacitance value for a combination of star connected inductances and delta connected capacitances, determining load power factor based on wattmeter readings, calculating power delivered to a star connected resistive load, and calculating the ratio of line currents for a load connected in star vs delta.

Uploaded by

Merey Zhumayeva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views1 page

Quiz 1: Three Phase Circuits: (10 Marks)

This document contains 7 questions about analyzing three phase circuits. The questions cover topics like calculating phase current, line current, power factor, apparent power, active and reactive powers for a delta connected load. Other questions involve finding circuit parameters for a balanced delta load, calculating capacitance value for a combination of star connected inductances and delta connected capacitances, determining load power factor based on wattmeter readings, calculating power delivered to a star connected resistive load, and calculating the ratio of line currents for a load connected in star vs delta.

Uploaded by

Merey Zhumayeva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

QUIZ 1: THREE PHASE CIRCUITS

1. A three phase delta connected load, with an impedance of (𝑨 + 𝑗𝑩) Ω per phase is
fed from 230V, 50 Hz supply. Find the phase current, line current, power factor,
apparent power, active and reactive powers of the load. (20 Marks)

2. A balanced 3-phase delta connected load takes C kW at a lagging current of D


Amps when connected to a 3-phase, 400V, 50 Hz source. Find the circuit
parameters per phase. (20 Marks)

3. Three star connected inductances, each of E Henry per phase, are connected in
parallel with three delta connected capacitances each of ‘C’ farads per phase. This
combination takes no current from 3-phase 230V, 50Hz supply. Find the value
of C? (20 Marks)

4. During three phase power measurement by two wattmeter method one wattmeter
reads zero. What is the nature of the load power factor? (10 Marks)

5. During three phase power measurement by two wattmeter method both


wattmeter reads equal power but of opposite sign. What is the nature of the load
power factor? (10 Marks)

6. A load consists of three resistors (F ohms each) which are connected in star
across 3-phase, 400 V mains. Find the power delivered to the load. (10 Marks)

7. A 3-phase balanced load is connected to a 3-phase mains once in star and then
in delta. Find the ratio of line currents in star to that in delta? (10 Marks)

You might also like