Q.PEAK BLK-G4.

1 290-300
Q.ANTUM SOLAR MODULE

The new high-performance module Q.PEAK BLK-G4.1 is the ideal solu-


tion for residential buildings thanks to its innovative cell technology
Q.ANTUM. The world-record cell design was developed to achieve
the best performance under real conditions – even with low radiation
intensity and on clear, hot summer days.

Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY


Higher yield per surface area and lower BOS costs and higher power
classes and an efficiency rate of up to 18.3 %.

INNOVATIVE ALL-WEATHER TECHNOLOGY


Optimal yields, whatever the weather with excellent low-light
and temperature behaviour.

ENDURING HIGH PERFORMANCE


Long-term yield security with Anti LID Technology,
Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™.

EXTREME WEATHER RATING YIELD SECURITY

High-tech aluminium alloy frame, certified for ANTI PID TECHNOLOGY


(APT)

high snow (5400 Pa) and wind loads (4000 Pa). HOT-SPOT PROTECT
(HSP)

TRACEABLE QUALITY
(TRA.Q ™)
MAXIMUM COST REDUCTIONS ANTI LID TECHNOLOGY
EN (ALT)
Up to 10 % lower logistics costs due to higher EN
module capacity per box.
MOD:27898 photon.info/laboratory

11/2016
A RELIABLE INVESTMENT Quality Tested
Best polycrystalline
 high reliability

Inclusive 12-year product warranty and 25-year linear 




low degradation
optimized durability
continous line monitoring
solar module 2014
Q.PRO-G2 235
performance warranty2. 174 modules tested
www.VDEinfo.com
ID. 40032587

1
APT test conditions according
to IEC/TS 62804-1:2015,
method B (−1500 V, 168 h)
2
See data sheet on rear
for further information.
THE IDEAL SOLUTION FOR:
Rooftop arrays on
residential buildings
MECHANICAL SPECIFICATION
Format 1670 mm × 1000 mm × 32 mm (including frame) EN 150 mm
1670 mm
980 mm
345 mm
Weight 18.5 kg
Front Cover 3.2 mm thermally pre-stressed glass with 4 × Grounding points ø 4.5 mm

anti-reflection technology Frame


Product label
Back Cover Composite film 951 mm

≥1000 mm
Frame Black anodised aluminium Cable with 1000 m m
connectors
Cell 6 × 10 monocrystalline Q.ANTUM solar cells Junction box

Junction box 66-77 mm × 90-115 mm × 15-20 mm,


Protection class ≥ IP67, with bypass diodes
8 × Drainage holes
Cable 4 mm² Solar cable; (+) 1000 mm, (−) 1000 mm 4 × Mounting slots (DETAIL A)

Connector Multi-Contact, MC4, IP65 and IP68 16 mm


32 mm DETAIL A

8.5 mm
24.5 mm

ELECTRICAL CHARACTERISTICS
POWER CLASS 290 295 300
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)
Power at MPP 2 PMPP 290 295 300
Short Circuit Current* I SC 9.63 9.70 9.77
Minimum

Open Circuit Voltage* VOC 38.19 39.48 39.76


Current at MPP* IMPP 9.07 9.17 9.26
Voltage at MPP* VMPP 31.96 32.19 32.41
Efficiency 2 η ≥ 17.4 ≥ 17.7 ≥ 18.0
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC 3
Power at MPP 2 PMPP 214.6 218.3 222.0
Short Circuit Current* I SC 7.77 7.82 7.88
Minimum

Open Circuit Voltage* VOC 36.65 36.92 37.19


Current at MPP* IMPP 7.12 7.20 7.27
Voltage at MPP* VMPP 30.14 30.33 30.52
1
1000 W/m², 25 °C, spectrum AM 1.5 G 2
Measurement tolerances STC ± 3 %; NOC ± 5 % 3
800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ

Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE


EN At least 98 % of nominal power during 110
[%]
efficiency[%]

100
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]

Q CELLS
first year. Thereafter max. 0.6 % degra-
EFFICIENCY

98 Industry standard for linear warranties*

95
Industry standard for tiered warranties*
dation per year.
100
At least 92.6 % of nominal power up to
Relative

10 years.
RELATIVE

90
At least 83.6 % of nominal power up to 90
25 years.
85

All data within measurement tolerances. 80


200 400 600 800 1000
80 Full warranties in accordance with the
Irradiance
[W/M[W/m²]
warranty terms of the Q CELLS sales IRRADIANCE 2
]
75 organisation of your respective country.
0 5 10 15 20 25 Typical module performance under low irradiance conditions in
Standard terms of guarantee for the 10 PV companies
*
YEARS comparison to STC conditions (25 °C, 1000 W/m2).
with the highest production capacity in 2014 (as at: September 2014)

TEMPERATURE COEFFICIENTS

Specifications subject to technical changes © Hanwha Q CELLS Q.PEAK BLK-G4.1_295-300_2017-11_Rev01_EN


Temperature Coefficient of ISC α [% / K] + 0.04 Temperature Coefficient of VOC β [% / K] − 0.28
Temperature Coefficient of PMPP γ [% / K] − 0.39 Normal Operating Cell Temperature NOCT [°C] 45

PROPERTIES FOR SYSTEM DESIGN


Maximum System Voltage VSYS [V] 1000 Safety Class II
Maximum Reverse Current IR [A] 20 Fire Rating C
Push / Pull Load [Pa] 5400 / 4000 Permitted Module Temperature −40 °C up to +85 °C
(Test-load in accordance with IEC 61215) On Continuous Duty

QUALIFICATIONS AND CERTIFICATES PARTNER


VDE Quality Tested, IEC 61215 (Ed. 2); IEC 61730 (Ed. 1), Application class A
This data sheet complies with DIN EN 50380.

NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation
and use of this product.

Hanwha Q CELLS GmbH


Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL [email protected] | WEB www.q-cells.com