EDWARDS® Catalog u EST3 Mass Notification

LIFE SAFETY & INCIDENT MANAGEMENT

Local Operations
Console
3-ANNCPU3, 3-LCDANN,
3-6ANN, 3-10ANN, 3-REMICA
7120-1657:
0193

S3424

APPROVED

Overview Standard Features


EST3 remote annunciation and control equipment is ideally suited • Variety of wallbox configurations neatly houses annunciation
to serve mass notification purposes. LCD display modules, remote and control, as well as paging equipment
microphones, and control and display modules configured for
• On-board microphone provides instant access to mass notifi-
mass notification operation provide everything that’s needed for
cation audio
annunciation, control, and paging operations. In these applica-
tions, annunciators are configured to operate as Local Operation • Slide-in labels makes mass notification configuration easy
Consoles (LOCs), from which mass notification is initiated and • Standard 3-LCD (168 characters) and large-format 3-LCDXL1
controlled. (960 character) display options
Annunciator cabinets are constructed from 16 gauge cold rolled • LCD uses queues to sort events
steel. The gray textured enamel finish of the annunciators comple-
ments any decor. Both surface and semi-flush mounting cabinet • Programmable LED flash rates
configurations maximize mounting flexibility and esthetic appeal.
Cabinet arrangements allow LED and LCD annunciation, as well
as paging, to easily combine in a single enclosure. Slide-in labeling Configurable Features
for LEDs and switches provides designation flexibility for mass
notification labeling. • Fan & Damper HOA 3-Position Switches
• Audio and strobe selector switches using two-position or three-
position switches
• Fire Alarm Zone Annunciation
• Prerecorded message selection

Page 1 of 4 D ATA S H E E T E85010-0148


Not to be used for installation purposes. Issue 1.1
Application Switch and Display Modules
Local Operating Consoles should be located so as to provide
response personnel and building occupants with access to the
mass notification (MNEC) system. They should be used to send
messages in emergency situations from locations in the building
other than from the Autonomous Control Unit (ACU).
LOC Location Guidelines:1
• Provide a separate LOC for use by the fire department near
the building fire alarm control panel (or fire command center)
unless this is also the location of the ACU.
• Do not place an LOC inside locked rooms or closets (with the
possible exception of the operating console intended for use
by the fire department near the FACP).
• Install LOCs at those facility entrances/exits that will be used
when building access is limited during emergency situations.
• Locate LOCs so that occupants do not need to travel a dis-
tance in excess of 61 m (200 ft) horizontally or to other floors
to access one.
• Make LOCs available for use by visitors in those facilities open
to unescorted visitors or to the public.
1
Unified Facilities Criteria 4-021-01: Design and Operation of Mass Notifi-
cation Systems, 5-6.1 & 4-5.1.

Controls and Indicators

3-24x 3-12Sx 3-12/S1xx 3-6/3S1xxx


24 Colored 12 switches 12 switches or
LEDs with one with two 3-4/3SGYWR
colored LED colored LEDs Six switches with
per switch per switch three colored
LEDs per switch

LEDs are available in red, green, yellow and white.


Consult the ordering information table for details.

1. 3-LCD
2. 3-REMICA paging microphone and in-use indicators
3. 3-12SR or equivalent
4. 3-24R or equivalent
5. MNEC ON button status LED. On indicates MNEC ON button
was pressed.
6. MNEC ON button. Press to activate MNEC operation.
7. PAGE ALL button status LED. On indicates PAGE ALL button
was pressed.
8. PAGE ALL button. Press to direct live voice instructions
from the 3-REMICA microphone to all notification appliance
circuits.
9. MNEC status LED. On indicates MNEC operation is active.
10. NAC status LED. On indicates all notification appliance cir-
cuits are active.

Page 2 of 4 D ATA S H E E T E85010-0148


Not to be used for installation purposes. Issue 1.1
(33.5 cm) (30.7 cm) (33.5 cm)

Dimensions
Semiflush Surface mount
14.5 in. (36.8 cm) 16.1 in. (40.9 cm)

2.75 in. (7.0 cm) 2.75 in. (7.0 cm)

16.1 in. (40.9 cm)

6ANN/B(-S)
13.19 in. 12.1 in. 13.19 in.
(33.5 cm) (30.7 cm) (33.5 cm)

Semiflush Surface mount


23.86 in. (60.60 cm) 25.47 in. (64.7 cm)

2.75 in. (7.0 cm)

25.47 in. (64.7 cm)

10ANN/B(-S)
12.1 in. 13.19 in. 12.1 in.
(30.7 cm) (33.5 cm) (30.7 cm)

Specifications
Catalog Number 3-ANNCPU3 3-ANNSM 3-LCD 3-LCDXL1
Agency Listings UL, ULC, FM, CE
Mounts over 3-ANNCPU
Mounting Space Two Spaces One Space Mounts over 3-ANNCPU
plus two spaces.
Communication Format RS-485 N/A N/A N/A
Current @ 24 Vdc
Standby 144 mA 10mA 40mA 48mA
Alarm 144 mA 10mA 42mA 50mA
Wiring Termination Plug in terminal strip
Twisted Pair 18-14 AWG
Wiring Size
(0.75-1.5 mm²) N/A
5000 ft (1524m)
Max. Wire Distance
between any 3 panels
Relative Humidity 93% non condensing at 90° F (32° C)
Temperature Rating 0-49° C (32 - 120° F)
Wiring Styles Class A or Class B
The EST3 is modularly listed under the following standards: UL 864 categories: UOJZ, UOXX, UUKL and SYZV, UL 294 category ALVY, UL 609 category AOTX, UL 636
category ANET, UL 1076 category APOU, UL 365 category APAW, UL 1610 category AMCX, UL 1635 category AMCX. ULC-S527, ULC-S301, ULC-S302, ULC-S303,
ULC-S306, ULC/ORD-C1076 and ULC/ORD-C693. UL2572 for Mass Notification.

For detailed specifications on EST3 compatible annunciator display and control modules please refer to EDWARDS literature sheet part number 85010-0055.

Page 3 of 4 D ATA S H E E T E85010-0148


Not to be used for installation purposes. Issue 1.1
Ordering Information
Catalog Ship Wt.
Description
Number lb (kg)
Command Module Annunciators (Come with CPU, LCD display and doors. Order wallbox
L I F E S A F E TY & I NCI DE NT M AN AGEM EN T separately.)
3-LCDANN Remote LCD Command Module Annunciator. 3.8 (1.7)
Contact us
Base Annunciators (Come with two 3-ANNSM annunciator support modules, a CPU, and doors.
Phone: 800-655-4497 (Option 4) Order Display/Control modules, additional support modules & wallbox separately.)
Email: [email protected]  
Website: edwardsfiresafety.com 6.28
3-6ANN Six Position Base Annunciator.
(2.85)
8985 Town Center Pkwy 3-10ANN 10 Position Base Annunciator. 10.5 (4.8)
Bradenton, FL 34202

© 2020 Carrier CPU, Support Module, & LCD Displays


All rights reserved. 3-ANNCPU3 Annunciator CPU 1 (.45)
CPU doors with filler plates. Order separately, one required per CPU
3-CPUDR 0.25 (.11)
where no LCD display is installed.
3-ANNSM Annunciator Support Module .45 (.2)
3-LCD Liquid Crystal Display Module, eight lines. .8 (.36)
Liquid Crystal Display Module, 40 lines mounts in 3-6ANN or 3-10ANN
3-LCDXL1 anunciators. Note one 3-LCDXL1KBL, (ordered separately) is required for each
3-LCDXL1 mounting into 3-6ANN or 3-10ANN annunicator boxes.
Cable for 3-LCDXL1 (Use to connect 3-ANNCPU3 to first annuciator support
3-LCDXL1KBL
module.

Control/Display Modules
3-CPUDR Two blank filler plates suitable for any annunciator blank space. .5 (.22)
3-24R 24 Red LED Display Module .35 (.12)
3-24Y 24 Yellow LED Display Module .35 (.12)
3-24G 24 Green LED Display Module .35 (.12)
3-12SR 12 switches with 12 Red LED Display/Control Module .35 (.12)
3-12SY 12 switches with 12 Yellow LED Display/Control Module .35 (.12)
3-12SG 12 switches with 12 Green LED Display/Control Module .35 (.12)
3-12RY 12 Red LED and 12 Yellow LED Display Module .35 (.12)
3-12/S1GY 12 switches with one Green and one Yellow LED per switch .35 (.12)
3-12/S1RY 12 switches with one Red and one Yellow LED per switch .35 (.12)
3-12/S2Y 12 switches with two Yellow LEDs per switch .35 (.12)
Six groups of three switches. Each switch with one LED: Green, Yellow,
3-6/3S1G2Y .35 (.12)
Yellow.
Six groups of three switches. Each switch with one LED: Green, Yellow,
3-6/3S1GYR .35 (.12)
Red.
12 switches in four groups of three switches, switch one with a green
3-4/3SGYWR LED, switch two with yellow and white LEDs and switch three with a .35 (.12)
red LED
Filler Plate, order separately one required per 3-ANNSM when no
3-FP 0.1 (0.05)
LED or LED/Switch module installed on operator layer.

Microphone
3-REMICA Remote microphone for use in 3-ANN series annunciator cabinets 15 (6.8)

Enclosures
6ANN/B Six position LED/LCD flush mount wallbox 7.0 (3.2)
6ANN/B-S Six position LED/LCD surface mount wallbox 7.0 (3.2)
10ANN/B Ten position LED/LCD flush mount wallbox 9.0 (4.1)
10ANN/B-S Ten position LED/LCD surface mount wallbox 9.0 (4.1)
04-01-20

Page 4 of 4 D ATA S H E E T E85010-0148


Not to be used for installation purposes. Issue 1.1