Catalog Altivar Process Modular Variable Speed Drives For Cabinet Integration

Download as pdf or txt
Download as pdf or txt
You are on page 1of 109

Catalog | August 2021

Variable speed drives


Altivar Process for Cabinet Integration

www.se.com
Quick access to product information
Get technical information about your product

Each commercial reference presented in a catalog contains a hyperlink.


Click on it to obtain the technical information of the product:
– Characteristics, Dimensions and drawings, Mounting and clearance,
Connections and schemas, Performance curves
– Product image, Instruction sheet, User guide, Product certifications,
End of life manual

Find your catalog

• Up-to-date catalogs
> With just 3 clicks, you can access the Industrial Automation • Embedded product selectors,360° pictures
• Optimized search by commercial references
and Control catalogs, in both English and French
> Consult digital automation catalogs at Digi-Cat Online

Select your training

> Find the right Training for your needs on our Global website
> Locate the training center with the selector tool, using this link
Altivar
Discover Altivar
Variable speed drives and soft starters
Altivar variable speed drives and soft starters deliver top performance
in motor control applications across machines, processes, and
buildings. With built-in intelligence, these smart connected devices
gather and share data to improve operational efficiency, safety, and
reliability.

Explore our offer


- Altivar Process
- Altivar Machine
- Altivar Building
- Altivar Soft Starters
Green Premium TM

Enhance sustainability with AltivarTM Process drives


Superior environmental performance thanks to upgradability and modernization solutions
Altivar Process is RoHS and REACH compliant Communication & Wi-Fi modules
• Transparent environment information The additional fieldbus modules allow you to easily integrate
• Life Cycle Analysis, compliant with ISO 14025 Altivar Process drives in your scalable automation system.
• Circularity Profile
Together with the Wi-Fi access point, they bring easy access
to the real data provided by the drive, helping the digitalization
and easy integration of the drive in Industry 4.0 technologies.
Altivar Process drives offer key benefits to help you achieve
superior sustainable performance by enhancing functionality, Passive filters*
performance, and capacity of both hardware and software. The optional passive filter available with Altivar Process drives
offers you the possibility to improve your installation's power
quality by reducing the harmonics levels, even keeping your
The additional hardware options and firmware upgradability existing drives installed.
capabilities of Altivar Process can help you to maximize process
continuity and operation, as well as reduce your operational Additional I/O & safety modules*
expenses, by avoiding the need to replace your drive or modify The I/O module helps you to extend your application's
your existing installation as a retrofit. performance and integration.
Benefits The Safety module optimizes the overall cost of the installation
• Maximize process continuity and operation by avoiding the need for additional external devices, while
• Reduce your OPEX conforming to international safety standards.
• Easy scalability of your automation system Firmware updates & Service expertise
• Future-ready solution for Industry 4.0 Our global network of service experts offers you the possibility
• Improve the power quality of your system with a low of upgrading your drive’s firmware and modernizing its
investment hardware to extend your drive's service life.
• Improve the Safety Integrity Level (SIL), and/or
Performance Level (PEL), integration, and Experience the difference today at
performance of your application
• Optimize your maintenance costs and the drive's se.com/green-premium
service life
* For more information regarding the compatibility of these options, please visit us at se.com/drives
Life is On | Schneider Electric
www.se.com
Contents

b General presentation................................................................................. page 2


Altivar Process Modular drives for cabinet integration
selection guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6

b Altivar Process Modular variable speed drives presentation.............. page 10


b Altivar Process Modular offer structure
v Presentation.............................................................................................. page 18
v Description................................................................................................ page 19

Altivar Process Modular variable speed drives


b Sub-assemblies and accessories
v Power modules.......................................................................................... page 20
v Control units.............................................................................................. page 22
v Housings................................................................................................... page 23
v Control cables............................................................................................ page 23
v Power busbar kits...................................................................................... page 24
v Fuses......................................................................................................... page 24
v Mechanical mounting kits.......................................................................... page 25
v Additional modules for liquid-cooled drives................................................ page 26
v Braking modules........................................................................................ page 27
v Control units for braking unit...................................................................... page 27
b Options..................................................................................................... page 28
b Drives for cabinet integration
v Presentation.............................................................................................. page 30
v Architectures............................................................................................. page 31
v 400...480 V 50/60 Hz supply Standard drives............................................ page 35
v 500...690 V 50/60 Hz supply Standard drives............................................ page 41
v 400...480 V 50/60 Hz supply Low Harmonic/Regen drives........................ page 47
v 500...690 V 50/60 Hz supply Low Harmonic/Regen drives........................ page 53
v 400...480 V 50/60 Hz supply Standard Liquid-cooled drives ..................... page 59
v 500...690 V 50/60 Hz supply Standard Liquid-cooled drives ..................... page 65
v Braking unit references.............................................................................. page 71
v Combinations............................................................................................ page 80
b Motor starters
v Applications............................................................................................... page 94
v Combinations............................................................................................ page 94

Services
b A whole world of services for your drives.............................................page 110

Index
b Product reference index.........................................................................page 112

1
General presentation Variable speed drives
Altivar Process
Business optimization, process efficiency

Altivar Process is the new comprehensive range of variable speed drives from
Altivar Process Schneider Electric, covering the majority of industrial applications with two series:

Provides the efficiency you deserve > ATV600: drives focused on fluid management and processing and energy saving
> ATV900: drives focused on maximum productivity with exceptional motor control
and connectivity

Depending on customer requirements, Altivar Process drives are available as


wall-mounting, floor-standing, and optimized solutions for integration in cabinets.

Wall-mounting drives Enclosed drive solutions Drives for cabinet integration


from 0.75 kW up to 315 kW from 0.75 kW up to 2600 kW from 0.75 kW up to 2600 kW
(1...500 HP) (1...2600 HP) (1...2600 HP)

Altivar Process range

Business optimization
Optimum monitoring of your process
> Instant response if pump efficiency drops thanks to embedded pump monitoring
> Notification of critical operating points without additional sensors
> Process integration with pressure, flow, and level control including compensation
of flow losses

Energy-saving drive solution


> Up to 30% energy saving when on standby due to the innovative ‘‘Stop & go’’
operation without additional costs
Pump monitoring display
> Smart control of the internal fans depending on operation
> Optimum energy efficiency over the whole lifecycle
> Data logging and graphic display of the power consumption
Energy consumption

STOP
Process efficiency
Motor performance and connectivity
GO
> Excellent motor performance on any type of motor
> Ethernet dual port offers maximum services such as connection to the control
Operating

room and process transparency


Energy saved > Network service helps ensure operation continuity even in case of connection
Ready

breakdown
“Stop & go”
t
> Web server and data logging help to reduce downtime through fast
troubleshooting and preventive maintenance
“Stop & go” function
Altivar Efficiency Calculator
This tool calculates the level of energy efficiency of your variable speed drive
according to the Ecodesign standard EN/IEC 61800-9-2.
> Drive efficiency (CDM Complete Drive Module)
Drive performance is determined according to 8 operating points considering
Calculate your level of energy efficiency torque and speed
with the Altivar Efficiency Calculator > System efficiency (PDS Power Drive System)
System performance is determined according to 8 operating points considering
torque and speed. This includes the efficiency of the variable speed drive and its
motor.

Saving energy with variable speed drives


2
General presentation Variable speed drives
(continued) Altivar Process
Real-time intelligence, user-friendliness, green product

ur
Sec ity Real-time intelligence
Web server and services via Ethernet
> Embedded Web server interface based on the Ethernet network gives you
process monitoring with your daily working tools.
AchillesTM Level2 certified
> Local and remote access to energy use and customized dashboards means
your energy is visible anywhere, any time, on PC, tablet, or smartphone.
ODVA organization:
Supports network
technologies based on
EtherNet/IP
User-friendliness
Simple integration in controller environments
FDT Technology: > Easy integration thanks to standardized FDT/DTM and ODVA technology
A widely-accepted
international standard in
> Supported by predefined EcoStruxure Control Expert libraries
the automation industry > Easy access via PC, tablet, or smartphone
> Robust connection via ‘‘cybersecure Ethernet’’

for Industry
Oil, Gas & Mining, Minerals & Consumer Packaged
Petrochemicals Water & Wastewater Machinery Discrete Industries
Metals Goods
EcoStruxure™Architecture

Apps,
Analytics & Field Services
Services
End-to-end Cybersecurity

Engineering Asset Performance EcoStruxure Plant Advisor EcoStruxure Machine Advisor


Cloud and/or On Premise

Planning & Operations Monitoring and Control


Modicon

Edge
Control
Industrial Edge Control EcoStruxure EcoStruxure EcoStruxure EcoStruxure Triconex SCADA Systems EcoStruxure Power
for IIoT Automation Expert Process Expert Foxboro DCS Safety Systems Monitoring Expert

Harmony Altivar EcoStruxure TeSys Lexium Set Series

Connected
Products
Advanced operator Variable speed drives Process Innovative and Advanced motion Advanced motion
and soft starters Instrumentation connected solutions control and robotics control and robotics Sensors and
interface and
RFID
industrial relays for motor starters

Sophisticated service concept


> Modular design provides easy spare parts logistics
> Optimized maintenance costs due to dynamic maintenance schedule, with
integrated monitoring of individual components
> Simple exchange of power modules and fans
> Quick assistance with dynamic QR codes and Customer Care app

Scanning the QR code from Instant access to online help


a smartphone or tablet
Green product
Designed to have a smaller carbon footprint
> The Green Premium product label, Schneider Electric’s eco-mark, indicates your
compliance with international environmental standards such as:
- RoHS according to European Directive 2011/65 and the delegated
Directive (EU) 2015/863
- REACH according to EU regulation 1907/2006
- IEC 62635: The end-of-life instructions comply with the latest recycling
rules; up to 85% of the product components can be recycled

(1) The Schneider Electric industrial software business and AVEVA have merged to trade as
AVEVA Group plc, a UK listed company. The Schneider Electric and Life is On trademarks
are owned by Schneider Electric and are being licensed to AVEVA by Schneider Electric.

Best-in-class service concept


3
General presentation Variable speed drives
(continued) Altivar Process Modular
Modularity

nce Exce The Altivar Process Modular offer is designed for easy and cost-effective integration
na
of power-intensive drives into cabinets. From just a few standard components it is
te

lle
Main

nce

possible to build a wide range of air- and liquid-cooled drives from 75 to 2600 kW
(125 to 2600 HP) in different integration types.

Customers using our Altivar Process Modular offer benefit from all the advanced
features of service-oriented Altivar Process ATV600 and ATV900 drives developed
for industrial applications such as water & wastewater, mining, minerals & metals, oil
& gas, and consumer packaged goods (CPG).
Consolidating a powerful range

> ATV600 drives focused on fluid management and processing and energy saving
> ATV900 drives focused on maximum productivity with exceptional motor control
and connectivity

Modularity
Get more than just a drive with the Altivar Process Modular offer:
> Standardized and cost-efficient integration
> Flexibility in cabinet design such as protection rating and incoming supply
equipment
> Prewired, tested electric core components
> Integrated category C3 EMC filter
> Reduced harmonics with integrated line choke for Standard drives and less than
3% THDi for Low Harmonic/Regen drives
> Integrated high-efficiency motor filter reducing the risk of motor winding insulation
aging and motor damage even for longer motor cables
> Ready-to-connect line supply terminals on top and motor terminals at the bottom
> Reduced downtime of assets thanks to easily changeable electric core
components such as power module with wheel (for Standard/Reduced Height
drives) and power fan (for Low Harmonic/Regen, Standard, and Reduced Height
drives) inside a drawer accessible from the front face

Option and accessories supplied Flexible drive solutions


Electric core components
by Schneider Electric or for cabinet integration
manufactured locally

Standardized integrated cabinet design

Easy and standardized cabinet integration


4
General presentation Variable speed drives
(continued) Altivar Process Modular
Cabinet integration

m
-m
e-to ark Cabinet integration
et
Ti

Standardization of integration design for ATV600


and ATV900 solutions
> ATV600 and ATV900 drive solutions by simply changing the control unit
> Larger application scope with power rating through module paralleling up to
Cost-saving solution due to standardization 1800 kW/2500 HP at 400 V supply voltage and up to 2600 kW/2600 HP at 690 V
and local production supply voltage
> Reduced engineering workload thanks to standardization
> Optimized supply chain with standard sub-assembly and kits available ex stock

Local production
> Assembly of Modular drive architectures on sites of qualified partners belonging to
Schneider Electric network
> Altivar Process Modular partners have access to dedicated selection tools,
drawings, EPLAN macros, integration manuals, videos, and training material
> Options and accessories may be supplied by Schneider Electric or manufactured
locally

Fast construction of power connections and


control cabling Main benefits
> Cost-saving solution with reduced integration workload (lighter and less space-
consuming) and simplified purchasing (optimized number of parts covering all
architectures)
> Reduce lead time to end users thanks to standardized integration design and
simple adaptation as per application requirement
> Enlarge your business scope thanks to simple maintenance of the Altivar Process
Modular offer

Compact compared with a standard product


5
Selection guide Variable speed drives
Altivar Process Modular
Drives for cabinet integration

Market segments b Water & wastewater b Water & wastewater


b Oil & gas b Oil & gas
b Mining, minerals & metals b Mining, minerals & metals
b Consumer packaged goods (CPG)

Mounting type Cabinet integration


Drive type Drive products for cabinet integration Modular Standard drives Modular Low Harmonic/Regen drives Modular Liquid-cooled drives
Degree of protection IP20 IP00
Power range Three phase: 380…480 V (kW/HP) 0.75...90/1...120 – –
for 50...60 Hz line supply Three-phase: 400 V (kW) – 110...800 110...1800
Three-phase: 440 V (kW) – 110...800 110...1800
Three-phase: 480 V (HP) – 150...1100 150...2500
Three-phase: 500 (kW) – 75...800 110...1900
Three-phase: 600 (HP) – 125…1200 150...2600
Three-phase: 690 (kW) – 110…1200 160...2600
Drive Output frequency 0.1...500 Hz
Control type Asynchronous motor Standard constant torque, variable standard torque, optimized torque mode
Synchronous motor PM (permanent magnet) motor, synchronous reluctance motor
Functions Advanced functions Including all the advanced features of ATV600 drives:
b Accurate measurement for monitoring system energy consumption (deviation < 5%)
b Installation energy drift detection
b Embedded Ethernet with direct access to system configuration and monitoring
b Integration of actual pump curves to optimize the system operating point
b Optimized pump monitoring based on actual operating point
b Sensorless estimated flow rate
b Measurements expressed in working units (e.g. m3/h, kWh/m3)
b Limitation of overvoltage at the motor terminals
b Contextual access to technical documentation through dynamic QR code
b Continuous and historical real-time measurements with customizable dashboards
b Predictive and preventive maintenance tracking functions (e.g. temperatures with PT100/1000 probe, fan monitoring)
b Easy setting of drive identification for Altivar Process Modular drives
Integrated safety function 1: STO (Safe Torque Off) SIL3
Number of preset speeds 16
Number of integrated I/O Analog inputs 3: Configurable as voltage (0...10 V) or current (0-20 mA/4-20 mA), 2 of them including probes (PTC, PT100, PT1000, or KTY84)
Digital inputs 6: Voltage 24 V c (positive or negative logic)
Digital output –
Analog outputs 2: Configurable as voltage (0...10 V) or current (0-20 mA)
Relay outputs 3: 1 with NO/NC contacts and 2 with NO contacts
Safety function inputs 2: For safety function STO
Extended I/O module Analog inputs 2 differential analog inputs configurable via software as voltage (0...±10 V) or current (0-20 mA/4-20 mA), or for PTC, PT100, or PT1000 2- or 3-wire probes
(optional) Digital inputs 6: Voltage 24 V c (positive or negative logic)
Digital outputs 2: Assignable
Extended relay module Relay outputs 3: NO contacts
(optional)
Communication Integrated Modbus/TCP, Modbus serial link
Option modules Ethernet/IP, Modbus TCP and MD-Link dual port, CANopen daisy chain, SUB-D, and screw terminal block, PROFINET, PROFIBUS DP V1, DeviceNet, BACnet MS/TP, POWERLINK
Configuration and runtime tools Graphic display terminal, embedded Web server, DTM (Device Type Manager), SoMove software
Standards and certifications 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, EN/IEC 61800-3, EN/IEC 61800-5-1, 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 13849-1, TÜV certification, e marking, cULus, IEC 61508, IEC 61000-4-5, IEC 61000-4-6, EN/IEC 61800-3, EN/IEC 61800-5-1,
IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, Marine certification (DNV-GL, ABS, RINA, BV, LR) (1), ATEX 2/22, ATEX 1/21, IEC 61000-3-12, IEC 60721-3, IEC 13849-1, TÜV certification,
TÜV certification, e marking, ATEX 2/22, ATEX 1/21 e marking, cULus, IEC 61508, ATEX 2/22, ATEX 1/21
References ATV630pppN4Z ATV6A0ppppp ATV6B0ppppp ATV6L0ppppp
Page – 35 47 59
(1) For marine product certificate, please contact your Schneider Electric representative.

More technical information on www.se.com More technical information on www.se.com

6 6
7
Selection guide (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration

Market segments b Oil & gas b Water & wastewater


b Mining, minerals & metals b Oil & gas
b Consumer packaged goods (CPG) b Mining, minerals & metals
b Water & wastewater

Mounting type Cabinet integration


Drive type Drive products for cabinet integration Modular Standard drives Modular Low Harmonic/Regen drives Modular Liquid-cooled drives
Degree of protection IP20 IP00
Power range Three-phase: 380…480 V (kW/HP) 0.75...90/1...120 – –
for 50...60 Hz line supply Three-phase: 400 V (kW) – 110...800 110...1800
Three-phase: 440 V (kW) – 110...800 110...1800
Three-phase: 480 V (HP) – 150...1100 150...2500
Three-phase: 500 (kW) – 75...800 110...1900
Three-phase: 600 (HP) – 125…1200 150...2600
Three-phase: 690 (kW) – 110…1200 160...2600
Drive Output frequency 0.1...599 Hz
Control type Asynchronous motor Standard constant torque, variable standard torque, optimized torque mode
Synchronous motor PM (permanent magnet) motor, synchronous reluctance motor
Functions Advanced functions Including all the advanced features of ATV900 drives:
b High-performance motor control with an overload torque up to 180% Tn in an open or closed loop
b Asynchronous, synchronous, special motors: all efficiency classes, brand independent, permanent magnet motors, torque motors, conical sliding rotor, reluctance motor
b Integrated EtherNet/IP and Modbus TCP dual port, cybersecurity (Achilles Level 2)
b Smart integration in PlantStruxure and Foxboro Evo process automation systems
b Optimized energy efficiency, detection of energy consumption drift of the installation
b Adaptation to the process by dedicated functions with modular design
b Embedded safety functions STO SIL3
b Master/slave and load sharing with drive-to-drive capability:
v torque sharing on rigid coupling
v torque sharing on elastic coupling
b Contextual access to technical documentation through dynamic QR code
b Continuous and historical real-time measurements with customizable dashboards
b Predictive maintenance (e.g. temperatures with PT100/1000 probe, fan monitoring, etc.)
b Easy setting of drive identification
Integrated safety function 1: STO (Safe Torque Off) SIL3
Number of preset speeds 16
Number of integrated I/O Analog inputs 3: 2 configurable as voltage (0...10 V) or current (0-20 mA/4-20 mA), including probes (PTC, PT100, PT1000, or KTY84), and 1 configurable as voltage (0...±10 V)
Digital inputs 8: Voltage 24 V c (positive or negative logic)
Digital output 1: Assignable, can be used as PTO (pulse train output)
Analog outputs 2: Configurable as voltage (0...10 V) or current (0-20 mA)
Relay outputs 3: 1 with NO/NC contacts and 2 with NO contacts
Safety function inputs 2: For safety function STO
Extended I/O module Analog inputs 2 differential analog inputs configurable via software current (0-20 mA/4-20 mA), or for PTC, PT100, or PT1000 2- or 3-wire probes
(optional) Digital inputs 6: Voltage 24 V c (positive or negative logic)
Digital outputs 2: Assignable
Extended relay module Relay outputs 3: NO contacts
(optional)
Communication Integrated EtherNet/IP, Modbus/TCP Dual port, Modbus serial link
Option modules CANopen daisy chain, SUB-D, and screw terminal block, PROFINET, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK
Configuration and runtime tools Graphic display terminal, embedded Web server, DTM (Device Type Manager), SoMove software
Standards and certifications 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, EN/IEC 61800-3, EN/IEC 61800-5-1, 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, Marine certification (DNV-GL, ABS, RINA, BV, LR) (1), IEC 13849-1, TÜV certification, e marking, IEC 61000-4-5, IEC 61000-4-6, EN/IEC 61800-3, EN/IEC 61800-5-1,
IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, cULus, ATEX 2/22, ATEX 1/21 IEC 61000-3-12, IEC 60721-3, IEC 13849-1, TÜV certification,
TÜV certification, e marking, ATEX 2/22, ATEX 1/21 e marking, cULus, IEC 61508, ATEX 2/22, ATEX 1/21
References ATV930pppN4Z ATV9A0ppppp ATV9B0ppppp ATV9L0ppppp
Page – 36 48 60
(1) For marine product certificate, please contact your Schneider Electric representative.

More technical information on www.se.com More technical information on www.se.com

8 9
Presentation Variable speed drives
Altivar Process Modular

Process
Altivar Process drives are specifically designed to meet the requirements of the
following market segments:
b Water & wastewater
b Oil & gas
b Mining, minerals & metals
b Consumer packaged goods (CPG)

Altivar Process Modular range

EcoStruxure PlantTM integration


EcoStruxure Foxboro DCS
process automation system The association of Altivar Process services with Schneider Electric process
automation control systems like EcoStruxure Foxboro DCS (for process systems)
or EcoStruxure Hybrid DCS (for hybrid systems) offers a high-performance, global
automation and motor control solution with optimized total cost of ownership (TCO).

The solution provides operational integrity for people, processes, and assets, with
improved maintenance support to help reduce downtime and ensure operation
Mesh control network continuity.

It offers operational insight by accessing more information to optimize the process


and control energy efficiency.

Based on market standards (FDT/DTM, Ethernet, etc.), it is a sustainable, scalable


solution that enables processes to be adapted easily and affordably.
Valve
Ethernet
Serial link

Pump

Altivar Process Drive System


and drives

Altivar Process in EcoStruxure Foxboro DCS architecture


Water & wastewater applications
b Pumping
b Drilling
b Suction
b Dosing
b Odor control
b Ventilation
b Gas compression
b Treatment plant
b Wastewater treatment
b Sludge removal

Use
b Pumping station and storage tank
b Irrigation
b Treatment plant
b Desalination plant
b Storage and booster station
b Housing
b Wastewater lift station
b Wastewater treatment
b Discharge back into the environment, land application
b Decanter

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

10
Presentation (continued) Variable speed drives
Altivar Process Modular

Process (continued)
Oil & gas applications
b Hydrocarbon production:
v Drilling
v Offshore and onshore extraction
v Water treatment and re-injection
v Crude oil storage
v Separation
v Pipeline pumping
v Storage
v Refining
v DOF (digital oil field)

Use
b Pumps:
v Submersible
v Hydraulic
v Pipeline
v Reverse flow
v Water injection
v Kerosene
b PCP (progressive cavity pump)
b ESP (electrical submersible pump)
b Rod pump
b Mud pump
b Rotary table, top drive
b Draw works
b Regasification compressors
b Refining:
v Fans
v Compressors

Mining, minerals & metals applications


b Flotation and thickening
b Rinsing and filtration
b Mine shaft pumping
b Preheater fan
b Waste gas evacuation
b Cooling fan
b Separator for vertical roller mill
b Storage and loading
b Water supply
b Pumping
b Drying fans
b Open-pit or underground mining
b Stockpiling/homogenization
b Concentration/mineral separation
b Solid-liquid separation
b Final handling/transport
b Clinker production
b Cement production

Use
b Conveyors
b Grinders
b Mixers
b Pumps
b Tunnel boring machines
b Long-distance heavy conveying
b Bucket wheel excavator
b Special cranes:
v Gantry cranes
v Grab cranes
b Grinding mills (ball mills, SAG and AG mills)
b Spiral and magnetic separators
b Reclaimers and stackers
b Ship loaders
b Mobile mining machines
b Vibro feeders
b Crushers
b Long belt conveyors
b Kiln main drives
b Separators for VRM (vertical roller mills)

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

11
Presentation (continued) Variable speed drives
Altivar Process Modular

Process (continued)
Consumer packaged goods (CPG) applications
b Pumping
b Drying fans
b Dairy beverage
b Agribusiness

Use
b Conveyors
b Mixers
b Centrifuges
b Pumps
b Extruders
b Shredders
b Centrifuges
b Hot rotary dryers

General presentation of the offer


Altivar Process drives can help improve equipment performance and reduce
operating costs by optimizing energy consumption and user comfort.
Altivar Process drives provide a wide range of integrated functions, such as:
b Safety and automation functions that meet the requirements of some of the most
demanding applications
b Various optional communication modules available for seamless integration into
the main automation architectures
b Numerous configurable I/O as standard to facilitate adaptation to specific
applications
b Intuitive commissioning using the graphic display terminal and SoMove
commissioning software
b Local and remote access and monitoring using the embedded Web server
b Energy savings and protection of the grid by means of integrated harmonic filters
b Installation EMC conformity by means of integrated EMC filters
Altivar Process Modular drives are designed for IT systems.
Modular drive architecture with 2 power modules from 200 kW
to 315 kW on 400 V supply

Modular drive
Altivar Process Modular is ready to build into cabinets to create high-power drive
Common outlet for
solutions with minimum dimensions that withstand harsh environments.
Roof-top fan
air flow through
power and control Altivar Process Modular brings a new approach with sub-assemblies to build drives
sections
locally:
b A power module section to be combined in different drive architectures. Each
architecture covers several drive power ranges, set at the discretion of the
integrator by using SoMove commissioning software
b Control units that make the drive family differentiation of the power architecture
between ATV600 and ATV900 families
b Optional kits and accessories that can be supplied by Schneider Electric or
Common inlet for manufactured locally
Power fan air flow through
power and control b Altivar Process Modular Standard drives can be designed as Reduced Height
sections versions for integration in 1.6 m/5.25 ft cabinets
IP21/UL Type1 integration with a common cooling air b Liquid-cooled modules to create high-power drive solutions that withstand harsh
flow environments
Altivar Process Modular drives are designed to operate on IT and corner-grounded (1)
systems.
Altivar Process Modular drives can also be supplied as Engineered Drive System
variants from 75 to 2600 kW (125...2600 HP), developed by Schneider Electric based
on customer specifications. For more information, please contact your Schneider
Electric supplier.

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

12
Presentation (continued) Variable speed drives
Altivar Process Modular

Power air outlet


General presentation of the offer (continued)
Cabinet integration (air-cooled)
Control air outlet Altivar Process Modular brings flexible solutions for special integration constraints
as well as standard integration in 2 m/6.56 ft height and 600 mm/23.62 in. depth
cabinets with IP21 (UL Type 1)/IP54 (UL Type 12) protection rating.
The Altivar Process Modular drives offer consists of:
Door fan b Drive power and control modules
Control air inlet b Semiconductor protection fuses
Power fan through door fan b Line chokes to limit THDi levels for the Standard version and less than 3% THDi
for the Low Harmonic/Regen version
Power air inlet b A filter to help protect the motor against the effects of dv/dt
through a plinth b Accessible terminals to simplify the motor wiring and power wiring
(power fan inside
module) IP21 (UL Type 1) integration type creates a common cooling air flow for the power
IP54/UL Type 12 integration with a separate and control sections.
cooling air flow
The IP54 (UL Type 12) integration mechanical kit introduces a system for separating
the cooling air flow between the power and control sections, allowing operation in a
highly polluted environment as well as optimum management of thermal stress in
the plant room.

Cabinet integration (liquid-cooled)


Altivar Process liquid-cooled drives for cabinet integration offer a modular high-
power solution for installation in cabinets and separate enclosures. Thanks to the
optimized liquid cooling concept, these drives are suitable for operation in a very
harsh environment.
The integrated liquid cooling allows optimal dissipation of the heat losses and
therefore optimizes the encapsulation of the whole drive unit. Its robust design
meets the requirements for applications in harsh enviroments and provides
protection up to IP66.
Ideally suited to customer needs with flexible cooling concepts:
b Air-cooled drive with internal liquid/air heat exchanger
b Air-cooled drive with external liquid/air heat exchanger to dissipate the heat
losses out of the operating room
b Liquid-cooled drive with liquid/liquid heat exchanger, encapsulated solution for
harsh environment and “low noise” requirements

IP23 air-cooled design with IP23 with external air heat


internal liquid/air heat exchanger
exchanger

Optimized cabinet design


Altivar Process Modular liquid-cooled drives bring flexible solutions for special
integration constraints with a 6- or 12-pulse supply and robust design with two
offers:
b Universal: Suitable for all kinds of grid with integrated mains choke (THDi y 48%
at 6-pulse or THDi y 9% at 12-pulse supply at 80 to 100% load)
b Compact: Optimized with dedicated transformer for most compact dimensions

Up to IP66 with liquid/liquid


heat exchanger
(1) Only Modular Standard drives for 380...480 V supply are compatible with corner-grounded
systems.

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

13
Presentation (continued) Variable speed drives
Altivar Process Modular

General presentation of the offer (continued)


Low Harmonic/Regen drives
The Low Harmonic/Regenerative drives are used when drives need to generate
particularly low harmonics on the mains.

In addition, Low Harmonic/Regen drives are capable of feeding energy back to the
mains, enabling a 4Q operation and improving overall application efficiency.

In comparison with commonly-used 2-level AFE (active front end) architectures, the
3-level technology of Altivar Process Modular Low Harmonic/Regen drives allows
this new technology to reach a total distortion factor (THDi) of around 2% and thus
fulfills the requirements of standard IEEE 519 for a THDi < 5% in case of distorted
Low Harmonic/Regen drive architecture with 2 power modules mains. Additionally, the cos Phi ≈ 1 in each load situation (from 30 % Pn) helps to
reduce the line supply load.

The Low Harmonic/Regen drives range is an optimum solution for energy efficiency
and process optimization.

+ UDC
Device features
Enhanced motor service life due to the 3-level concept
The 3-level AIC (active infeed converter) technology reduces the voltage load at the
motor significantly, compared with other low harmonic frequency inverters. The
fluctuating adaptation of the DC link voltage helps to extend the motor service life.

- UDC
Reduced losses due to the 3-level concept
2-level technology In comparison with the traditional circuit structure of active mains rectifiers, the
switching frequency is increased and the current load is reduced at the same time
when using 3-level technology.
+ UDC
+ UDC
2 Compact dimensions due to the 3-level concept
A significant advantage of the 3-level technology is the reduced size of the integrated
- UDC
filter. Due to the increased switching frequency and its location inside the forced
2 cooling air channel, the dimensions of the filter can be almost halved.
- UDC

3-level technology

Braking units
Same integration process as standard power module
Braking units and standard power modules have the same frame and size. They use
the same integration kits and DC bus bar kits.

Compliant with Standard and Low Harmonic/Regen drives


Braking units can be built for APM Standard drives, APM Reduced Height drives and
APM Low Harmonic/Regen drives with an ATV900 control unit.

Compliant with any APM integration type


b Standard integration in 2 m/6.56 ft high cabinets
b Reduced Height integration in 1.6 m/5.25 ft high cabinets
b IP21/UL Type 1 with a common cooling air flow
Braking unit module b IP54/UL Type 12 with a separate cooling air flow

Advanced functions with ATV900


b With Standard drives:
v Full braking torque also in overload range
v Shortening and monitoring of deceleration time, such as for long travel application
v Temporary regenerative load, such as for hoist applications
b With Low Harmonic/Regen drives:
v Braking operation when Energy regeneration is not possible

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

14
Presentation (continued) Variable speed drives
Altivar Process Modular

General presentation of the offer (continued)


Selection tool for Altivar Process Modular
The Selection tool is an intuitive guide for defining the parts list and specification list
to build Altivar Process Modular drives.

It is used to:
b Design the correct Modular drive architecture according to the application needs
by simply choosing the drive type, protection rating, cabinet type and supplier,
supply voltage, and power rating
b Obtain the parts list containing the power modules, control units, mechanical
accessories, options, and specifications and their required quantity
b Customize the parts list with project details and additional materials

The tool is accessible to registered partners of Altivar Process Modular through the
download area of the mySchneider partner portal.
Selection tool for Altivar Process Modular

Altivar Process Altivar Process Modular Partner Program


The Altivar Process Modular offer is dedicated to partners building ATV600 and
Modular ATV900 high-power drive solutions.
Drive Integration Partner Program This offer enhances our partners’ offerings as they are able to:
b Build customized panels and high-power drive solutions by paralleling drive
modules up to 1800 kW (2500 HP) in 380...480 V supply voltage and
2600 kW (2600 HP) in 500...690 V supply voltage
b Assemble the final drive and perform panel integration
b Benefit from the standardized way of drive integration using the modular concept
b Perform the final power setting and drive registration
b Order/produce mechanical options for integration locally
b Access the download area of the partner portal and find all the relevant technical
documents, including mechanical specifications
b Access service training material for commissioning, assembly, and after-sales
services
b Become a Schneider Electric recognized trained and registered drive integration
partner

THDi y 48% for 80...100% load


Rugged
with Altivar Process
Altivar Process Modular drives are designed to adapt to the harshest environments.
b Ambient operating temperature
v Temperature without derating:
-10...40 °C/14...104 °F for Altivar Process Modular Standard (air- and liquid-cooled)
-5...40 °C/23..104 °F for Altivar Process Modular Low Harmonic/Regen
v Temperature with derating of output power: < 50 °C/< 122 °F
b Relative humidity without condensing: 5...95%
b Storage and transport temperature: -40…+70 °C/-40…+158 °F
b Operating altitude:
v 0…1,000 m/0…3,300 ft without derating
v 1,000...4,800 m/3,300…15,740 ft with derating of 1% per 100 m/330 ft
b Withstand to harsh environments:
Altivar Process drive THDi v Chemical class 3C3 conforming to IEC/EN 60721-3-3
v Mechanical class 3S3 conforming to IEC/EN 60721-3-3
v Printed circuit boards with protective coating
v IP00 to integrate in an enclosure

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

15
Presentation (continued) Variable speed drives
Altivar Process Modular

General presentation of the offer (continued)


Energy
Energy consumption

Altivar Process drives help to optimize power consumption by reducing the rms
STOP input current for the same load.
b Standard offer:
v THDi y 48% for 80 to 100% load on the most common operating range
GO
maintaining an optimum power factor
v Embedded line choke technology complying with standard IEC 61000-3-12
Operating

v Low Harmonic offer compatible with standard IEEE 519


Energy saved
Ready

In addition, thanks to the “Stop & go” function, Altivar Process drives can reduce
“Stop & go” power consumption by up to 30% during system stop phases by disabling some
t functions automatically (the power section, fans, backlighting, etc.). On a system
restart request, the Altivar Process drive takes less than 2 seconds to restart the
“Stop & go” function
motor.

Integrated as standard, the “Stop & go” function can be enabled and disabled in the
drive parameters.

Environment
The Altivar Process Modular drives offer has been developed to meet the
requirements of directives regarding protection of the environment and to anticipate
future changes in regulations:
b REACH (1) + solution for REACH Substitute It Now (halogen-free wiring and
plastics)
b PEP (Product Environmental Profile) eco-passport program for reducing the
carbon footprint and conserving raw materials
b EoLI (End of Life Instruction) (2)

Electromagnetic compatibility (EMC)


Compliance with electromagnetic compatibility requirements has been incorporated
into the design of Altivar Process Modular drives, which simplifies installation and
provides an economical means of helping to ensure equipment meets e marking
requirements.
Altivar Process Modular drives have category C3 EMC filters that allow 300 m/980 ft
of shielded motor cables.

(1) European regulation 1907/2006.


(2) According to IEC 62635 Enhanced Guidelines.

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

16
Presentation (continued) Variable speed drives
Altivar Process Modular

General presentation of the offer (continued)


Installation/Maintenance
Altivar Process Modular drives are ergonomically designed to adapt to any type of
installation:
b IP00 modules that can be integrated in cabinets with an IP21 (UL Type 1) or IP54
(UL Type 12) protection rating as a standard integration and up to IP66 with
liquid-cooled modules
b Easy installation of products and systems:
v Color code for connections to the removable terminal blocks on the HMI block
v Long cable: Highly efficient integrated motor filters for dv/dt and common mode
reduction and voltage peak limitation allow motor cable lengths up to 300 m/980 ft
with shielded cable (category C3 environment) and 500 m/1,640 ft with
unshielded cable (category C4 environment)
b Asynchronous or synchronous drive in open loop for 0.1...599 Hz output frequency
b Special motors: Submersible, synchronous reluctance, and tapered rotor motors
b Lower maintenance costs due to drive’s ergonomic design:
v Fans can be replaced in less than 5 minutes thanks to access from front face
and drawer design
v Wheel on standard drive power module for easy removal
v Limited number of parts and integrated power auxiliaries
b Embedded Web server:
v Compatible process elements for easier implementation
v Direct worldwide access to monitoring and maintenance functions:
- Reading values
- Modifying data
- Configuring parameters
- Changing controller status

Catalog Catalog
Integrated functions
Altivar Process Modular drives include numerous advanced functions for more
complex applications in each market segment.

For more information, please refer to the Altivar Process ATV600 and
Altivar Process ATV900 catalogs.
Altivar Process ATV600 Altivar Process ATV900
Variable speed drives Variable speed drives

se.com
www.se.com

Altivar Process catalogs


Click to open the documents

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

17
Presentation Variable speed drives
Altivar Process Modular

Altivar Process Modular offer structure


Presentation
The Altivar Process Modular drives offer is composed of sub-assemblies and
accessories that are integrated into cabinets to create modular drive solutions.

These separate elements can be ordered from our Schneider Electric Partner
Network. For more information on the references, see page 20.

Numerous drive solutions can be built using these modular parts.


For more information on the characteristics of these configurations, see page 35.

Altivar Process Modular Standard architecture from 1 to 6


modules

Altivar Process Modular Low Harmonic/Regen architecture


from 1 to 6 modules

Altivar Process Modular Standard Reduced Height architecture


from 1 to 6 modules

Altivar Process Modular - Liquid-cooled architecture from 1 to


6 modules

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

18
Description Variable speed drives
Altivar Process Modular

Altivar Process Modular offer structure (continued)


Description
The Altivar Process Modular drives offer consists of sub-assemblies and
accessories:
1  Power module, braking unit, or mains module
2  Front face cover
3  Control units for ATV600 and ATV900 or braking unit
Accessories
Optional extensions: Communication, I/O expansion, and encoder modules

2
1

3
2

Altivar Process Modular standard drives Altivar Process Modular Low Harmonic/Regen drives

1 1
2
2

3
3

Braking units Altivar Process Modular standard Reduced Height drives

Altivar Process Modular power connection kit


Altivar Process Modular - Liquid-cooled drives

Accessories comprise:
b Power connection kits
b Digi-Link cables
b Mechanical mounting kits

Altivar Process Modular Digi-Link cables For more information, please contact your Schneider Electric supplier.

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

19
References Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Power modules
ATVM_CP19046

Description Reference Weight


kg/lb
Standard architectures
Standard power module
Power module 160 kW - 380…480 V IP00: APM1A0C16N401 155/
b 1 x standard power unit 342
b 1 x standard mains unit
b 3 x fuse holder with screws and washers for the fuse
b 2 x brackets with nuts for front mechanical connection

Power module 200 kW - 500…690 V IP00: APM1A0C20Y6 168/


b 1 x standard power unit 370
b 1 x standard mains unit
b 3 x fuse holder with screws and washers for the fuse
b 2 x brackets with nuts for front mechanical connection
APM1A0C16N401
Low Harmonic/Regen power module
Power module 160 kW - 380…480 V IP00: APM1B0C16N4 260/
b 1 x power module for Low Harmonic/Regen APM drives 574
b 3 x fuse holder with screws and washers for the fuse
ATVM_CP24091
ATVM_CP20082

Power module 200 kW - 500…690 V IP00: APM1B0C20Y6 290/


b 1 x power module for Low Harmonic/Regen APM drives 639
b 3 x fuse holder with screws and washers for the fuse

Reduced Height architectures


Standard power module (Reduced Height integration)
Power module for Reduced Height 160 kW - 380…480 V APM1A0C16N4RH 100/
IP00: 220
b 1 x power module
Power module for Reduced Height 200 kW - 500…690 V APM1A0C20Y6RH 100/
IP00: 220
b 1 x power module
APM1A0C16N4RH APMCA03LCN4RH
Liquid-cooled architectures
Standard power module liquid-cooled
Standard power module 200 kW - 380…480V IP00: APM1L0C20N4 82.5/
b 1 x standard power unit with embedded 6-/12-pulse rectifier 182
b 1 x integrated water/water heat exchanger

Standard power module 315 kW - 380…480V IP00 APM1L0C31N4 82.5/


ATVM_CP20125

b 1 x standard power unit with embedded 6-/12-pulse rectifier 182


b 1 x integrated water/water heat exchanger

Standard power module 280 kW - 500…690V IP00: APM1L0C28Y6 82.5/


b 1 x standard power unit with embedded 6-/12-pulse rectifier 182
b 1 x integrated water/water heat exchanger

Standard power module 450 kW - 500…690V IP00 APM1L0C45Y6 82.5/


b 1 x standard power unit with embedded 6-/12-pulse rectifier 182
b 1 x integrated water/water heat exchanger

Overall dimensions
Reference WxHxD
APM1L0C28Y6
mm in.
APM1A0C16N401 230 x 1705 x 510 9.10 x 67.12 x 20.08
APM1A0C20Y6
APM1B0C16N4 450 x 1692 x 508 17.72 x 66.61 x 20
APM1B0C20Y6
APM1A0C16N4RH 230 x 1230 x 509 9.10 x 48.43 x 20
APM1A0C20Y6RH
APM1L0C20N4 232 x 1080 x 526 9.13 x 40.08 x 20.71
APM1L0C31N4
APM1L0C28Y6
APM1L0C45Y6

20
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Power modules
Description Reference Weight
kg/lb
Reduced Height architectures (continued)
Mains module (Reduced Height integration)
Mains module 1 line choke - 380…480V - IP00: APMCA01LCN4RH 103/
For combination with 1 standard power module. 227
ATVM_CP26093

b 1 x mains module for APM Standard Reduced


Height 380...480V
b Components for power fan management:
Controller, 48 VDC power supply, 2 x relays and 2 x relay
holders, 3 x fuses and 3 x fuse holders
Mains module 2 line chokes - 380…480V - IP00: APMCA02LCN4RH 160/
For combination with 2 x standard power modules. 353
b 1 x mains module for APM Standard Reduced
Height 380...480V
b Components for power fan management:
Controller, 48 VDC power supply, 2 x relays and 2 x relay
holders, 3 x fuses and 3 x fuse holders
APMCA02LCN4RH
Mains module 3 line chokes - 380…480V - IP00: APMCA03LCN4RH 217/
For combination with 3 x standard power modules. 478
b 1 x mains module for APM Standard Reduced
Height 380...480V
b Components for power fan management:
Controller, 48 VDC power supply, 2 x relays and 2 x relay
holders, 3 x fuses and 3 x fuse holders
Mains module 1 line choke - 500…690V - IP00: APMCA01LCY6RH 116/
For combination with 1 standard power module. 256
b 1 x mains module for APM Standard Reduced
Height 500…690V
b Components for power fan management:
Controller, 48 VDC power supply, 2 x relays and 2 x relay
ATVM_CP24091

holders, 3 x fuses and 3 x fuse holders


Mains module 2 line chokes - 500…690V - IP00: APMCA02LCY6RH 186/
For combination with 2 x standard power modules. 410
b 1 x mains module for APM Standard Reduced
Height 500…690V
b Components for power fan management:
Controller, 48 VDC power supply, 2 x relays and 2 x relay
holders, 3 x fuses and 3 x fuse holders
Mains module 3 line chokes - 500…690V - IP00: APMCA03LCY6RH 256/
For combination with 3 x standard power modules. 564
b 1 x mains module for APM Standard Reduced
Height 500…690V
APMCA03LCY6RH b Components for power fan management:
Controller, 48 VDC power supply, 2 x relays and 2 x relay
holders, 3 x fuses and 3 x fuse holders

Overall dimensions
Reference WxHxD
mm in.
APMCA01LCN4RH 269 x 1248 x 506 10.60 x 49.10 x 19.92
APMCA02LCN4RH
APMCA03LCN4RH
APMCA01LCY6RH
APMCA02LCY6RH
APMCA03LCY6RH

21
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Control units for power module


ATVM_CP19041

Description Reference Weight


kg/lb
ATV600 (1)
Standard module 380…480 V APM6A0CTLN401 6.8/
14.9
Standard module 500…690 V APM6A0CTLY6 6.8/
14.9
APM6A0CTLN401
Low Harmonic 380…480 V APM6B0CTLN4 8.0/
17.6
Low Harmonic 500…690 V APM6B0CTLY6 4.8/
ATVM_CP19025

10.6
Liquid-cooled 380...480 V APM6L0CTLN4 6.5/
14.3
Liquid-cooled 500...690 V APM6L0CTLY6 6.5/
14.3
ATV900 (1)
APM6B0CTLY6 Standard module 380…480 V APM9A0CTLN401 6.8/
14.9
Standard module 500…690 V APM9A0CTLY6 6.8/
14.9
ATVM_CP20126

Low Harmonic/Regen 380…480 V APM9B0CTLN4 8.0/


17.6
Low Harmonic/Regen 500…690 V APM9B0CTLY6 4.8/
10.6
Liquid-cooled 380...480 V APM9L0CTLN4 6.5/
14.3
Liquid-cooled 500...690 V APM9L0CTLY6 6.5/
APM9L0CTLY6 14.3

Overall dimensions
Reference WxHxD
mm in.
APM6A0CTLN401 230 x 678 x 108 9.10 x 16.80 x 4.30
APM9A0CTLN401
APM6A0CTLY6
APM9A0CTLY6
APM6L0CTLN4 230 x 510 x 131 9.10 x 20.08 x 5.16
APM6L0CTLY6
APM6B0CTLN4 450 x 520 x 105 17.72 x 20.47 x 4.13
APM9B0CTLN4
APM6B0CTLY6
APM9B0CTLY6
APM9L0CTLN4 230 x 510 x 131 9.10 x 20.08 x 5.16
APM9L0CTLY6
(1) All control units include 1 control unit (metal housing + control block + power board),
1 graphic display terminal, 1 Digi-Link cable, 1 cable for 24 V supply, and cables for voltage
measurement (mains, DC, motor).

22
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Housings
ATVM_65654_CPSCT18007

Description Reference Weight


kg/lb
Standard front face cover VW3A97A01 5.0/
11.0
Low Harmonic/Regen front face cover VW3A97B01 5.9/
13.0
Overall dimensions
VW3A97A01
Reference WxHxD
mm in.
VW3A97A01 230 x 678 x 108 9.06 x 26.70 x 4.25
VW3A97B01 450 x 520 x 105 17.72 x 20.47 x 4.13

Control cables
Description Reference Weight
kg/lb
RJ45 module-link cable 1.5 m/4.92 ft VW3A83BMR015 0.120/
0.264
RJ45 module-link cable 5 m/16.4 ft VW3A83BMR050 0.230/
ATVM_65654_CPSCT18005

0.507
Digi-Link cable 2 m/6.56 ft VW3A83CDG020 0.100/
0.220
Digi-Link cable 3 m/9.84 ft VW3A83CDG030 0.140/
VW3A83CDGpp 0.309
Digi-Link cable 5 m/16.4 ft VW3A83CDG050 0.230/
0.507
Digi-Link cable 10 m/33 ft VW3A83CDG100 0.430/
0.948

23
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Power busbar kits


ATVM_65654_CPSCT18009

Description Reference Weight


kg/lb
VW3A98ABMAAA Power busbar kit to connect 1 standalone power module in a VW3A98ABMAAA 4.5/
400 mm/15.75 in. width cabinet. 9.9

Power busbar kit to connect 2 side-by-side power modules in VW3A98ABMCAB 8.0/


a 600 mm/23.62 in. width cabinet 17.6

Power busbar kit to connect 3 side-by-side power modules in VW3A98ABMCAC 12.0/


a 800 mm/31.50 in. width cabinet 26.5
ATVM_65654_CPSCT18010

Power busbar kit to connect 2 remote power modules VW3A98ABMDCE 2.5/


integrated in side-by-side cabinet columns of: 5.5
VW3A98ABMCAC b 600 mm + 600 mm (23.62 in. + 23.62 in.) width or
b 800 mm + 600 mm (31.50 in. + 23.62 in.) width
Power busbar kit to connect 2 remote power modules VW3A98ABMDCF 2.0/
integrated in side-by-side cabinet columns of 800 mm + 4.4
800 mm (31.50 in. + 31.50 in.) width
Power busbar kit to connect: VW3A98ABPC1 1.0/
b 2 side-by-side standard power modules or 2.2
b 1 side-by-side standard power module + 1 braking unit
Power busbar kit to connect: VW3A98ABPDCE1 2.6/
ATVM_65654_CPSCT18012

b 2 remote standard power modules or 5.7


b 1 remote standard power module and 1 braking unit
In side-by-side cabinet columns of:
b 600 mm + 600 mm (23.62 in. + 23.62 in.) width or
b 800 mm + 600 mm (31.50 in. + 23.62 in.) width
Power busbar kit to connect 2 power modules integrated in VW3A98ABPDCF 2.0/
side-by-side cabinet columns of 800 mm+ 800 mm (31.50 in. + 4.4
31.50 in.) width
Power busbar kit to connect 1 standalone Low Harmonic VW3A98BBMAAB 8.4/
power module integrated in a 600 mm/23.62 in. width cabinet 18.5

VW3A98CTM01 Power busbar kit to connect 2 side-by-side Low Harmonic VW3A98BBMCAD 16.5/
power modules integrated in a 1,000 mm/39.37 in. width 36.4
cabinet
Power busbar kit to connect 2 remote Low Harmonic power VW3A98BBMDCG 1.8/
modules integrated in side-by-side cabinet columns of: 4.0
b 600 mm + 1,000 mm (23.62 in. + 39.37 in.) width or
b 1,000 mm + 1,000 mm (39.37 in. + 39.37 in.) width
ATVM_65654_CPSCT18013

Power busbar kit to connect 2 side-by-side Low Harmonic VW3A98BBPC 2.0/


power modules 4.4

Power busbar kit to connect 2 remote Low Harmonic power VW3A98BBPDCG 2.5/
modules integrated in side-by-side cabinet columns of: 5.5
b 600 mm + 1,000 mm (23.62 in. + 39.37 in.) width or
b 1,000 mm + 1,000 mm (39.37 in. + 39.37 in.) width
Power busbar kit to connect 1 Low Harmonic/Regen power VW3A98BBPDCK 1.0/
module with 1 braking unit integrated in side-by-side cabinet 2.2
columns of:
b 400 mm + 600 mm (15.75 in. + 23.62 in.) width or
VW3A98CTM02
b 400 mm + 1,000 mm (15.75 in. + 39.37 in.) width
Power busbar mounting kit VW3A98CTM01 0.5/
1.1

Power terminal kit VW3A98CTM02 7.5/


16.5
ATVM_65654_CPSCT18008

Fuses
Description Reference Weight
VW3A98CF4040 kg/lb
Set of 3 fuses 315 A VW3A98CF3169 0.750/
1.653

Set of 3 fuses 400 A, UL certified VW3A98CF4040 0.750/


1.653

24
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Mechanical mounting kits


ATVM_65654_CPSCT18014

Description Cabinet Reference Weight


kg/lb
Mounting kits
Mains terminal extension plates for drive architectures SF/TS8/VX25 VW3A98CTM03 6.5/
with UL certification 14.2
Mains bar support for a required SCR rating > 50 kA SF/TS8/VX25 VW3A98CTM04 0.2/
0.4
Mechanical mounting kit for integration of: SF/TS8 VW3A99ACFAA 6.6/
VW3A99ACFAA b 1 standard power module in a 400 mm/15.75 in. VX25 VW3A99ACFAA01 14.6
width cabinet
Mechanical mounting kit for integration of: SF/TS8 VW3A99ACFCB 9.5/
b 2 standard power modules in a 600 mm/23.62 in. VX25 VW3A99ACFCB01 20.9
width cabinet
Mechanical mounting kit for integration of: SF/TS8 VW3A99ACFEC 14.0/
b 3 standard power modules in a 800 mm/31.50 in. VX25 VW3A99ACFEC01 30.9
width cabinet.
ATVM_65654_CPSCT18018

Removable support SF/TS8/VX25 VW3A99AR01 2.2/


4.9
Mechanical mounting kit for integration of: SF/TS8 VW3A99BCFAB 17.0/
b 1 Low Harmonic/Regen power module in a VX25 VW3A99BCFAB01 37.5
600 mm/23.62 in. width cabinet
VW3A99AR01 Mechanical mounting kit for integration of: SF/TS8 VW3A99BCFCD 26.0/
b 2 Low Harmonic/Regen power modules in a VX25 VW3A99BCFCD01 57.3
1,000 mm/39.37 in. width cabinet.
Removable support for Low Harmonic power module SF/TS8/VX25 VW3A99BR01 16.5/
integration 36.4
Mechanical mounting kit for integration of: SF/TS8/VX25 VW3A99ACFCBN01 10.0/
b 1 standard power module + 1 mains module 22.0
Mechanical mounting kit for integration of: SF/TS8 VW3A99ACFCBM01 9.0/
b 2 standard power modules or 19.8
b 1 standard power module + 1 braking module or
b 2 braking modules
ATVM_CP20100

Mechanical mounting kit for integration of: VX25 VW3A99ACFCBM02 9.0/


b 2 standard power modules or 19.8
b 1 standard power module + 1 braking module or
b 2 braking modules
Mechanical mounting kit for integration of: SF/TS8 VW3A99ACFEBN01 12.0/
b 3 standard power modules or 26.5
b 2 standard power modules + 1 braking module
Mechanical mounting kit for integration of: VX25 VW3A99ACFEBN02 12.0/
VW3A99ACFCBM02 b 3 standard power modules or 26.5
b 2 standard power modules + 1 braking module
Mechanical mounting kit for integration of: SF/TS8/VX25 VW3A99ACFABM 5.5/
b 1 mains module 12.1

Top air ducts


Top outlet cooling air duct for IP54/UL Type 12 integration of: VW3A99ACA03 1.8/
b 1 standard power module or 4.0
ATVM_CP20109

b 1 braking unit
Top outlet cooling air duct for IP54/UL Type 12 integration of: VW3A99BCA03 1.7/
b 1 Low Harmonic/Regen power module 3.7
Top outlet cooling air duct for IP54/UL Type 12 integration of: VW3A99ACA04 3.0/
b 1 standard power module or 6.6
b 1 braking module
Top outlet cooling air duct for IP54/UL Type 12 integration of: VW3A99ACA11 2.5/
b 1 mains module 5.5
Top outlet cooling air duct for IP54/UL Type 12 integration of: VW3A99ACA12 4.0/
b 1 standard power module or 8.8
b 1 braking module in cabinet with an air cooling outlet at the top rear side
Top outlet cooling air duct for IP54/UL Type 12 integration of: VW3A99ACA13 3.0/
VW3A99ACA11
b 1 mains module in cabinet with an air cooling outlet at the top rear side 6.6

25
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Mechanical mounting kits (continued)


Description Cabinet Reference Weight
kg/lb
Bottom supports and ducts
ATVM_65654_CPSCT18002

Bottom support for IP21/UL Type 1 integration of: VW3A99ACA01 8.0/


b 1 standard power module VW3A99ACA07 17.6

Bottom support for IP54/UL Type 12 integration of: VW3A99ACA02 7.6/


b 1 standard power module VW3A99ACA08 17.8

Bottom inlet air duct for IP54/UL Type 12 integration of: VW3A99BCA02 6.9/
VW3A99ACA01
b 1 Low Harmonic/Regen power module 15.2
Bottom support for IP21/UL Type 1 integration of: SF/TS8 VW3A99ACA05 3.0/
b 1 standard power module or 6.6
b 1 mains module or
b 1 braking module
Bottom support for IP54/UL Type 12 integration of: SF/TS8 VW3A99ACA06 6.0/
b 1 standard power module or 13.2
b 1 mains module or
b 1 braking module
Bottom support for IP21/UL Type 1 integration of: VX25 VW3A99ACA09 3.0/
b 1 standard power module or 6.6
b 1 mains module or
ATVM_CP20105

b 1 braking module
Bottom support for IP54/UL Type 12 integration of: VX25 VW3A99ACA10 6.0/
b 1 standard power module or 13.2
b 1 mains module or
b 1 braking module
VW3A99ACA10
Mechanical mounting kits for liquid-cooled drives
Connection kit for drive power module and motor protection module in VW3A98LBPC1 15.0/
600mm/23.62 in. width cabinets for 2 to 6 modules 33.1
Mains bar support VW3A98LTMC1 1.5/
3.3
Set of tubes for liquid cooling VW3A98LGHC1 5.0/
11.0
Over-pressure valve VW3A98LGHC2 2.5/
5.5
Motor terminal extension for box lugs VW3A98LBPC3 2.5/
5.5
Braking module interconnection kit including cabinet cooling module VW3A98LBPC2 27.0/
adapter 59.5
Module-link cable 10 m/32.8 ft for braking unit VW3A83BMR100 0.430/
0.948
Steel support for liquid-cooled module VW3A99LR01 6.0/
13.2

Additional modules for liquid-cooled drives


ATVM_CP20128

Description Reference Weight


kg/lb
Line paralleling
Line paralleling module IP00, 380 … 480 V APM1L0LPMN4 40.0/
b 6- or 12-pulse supply 88.2
b 1 x paralleling choke
b 3 x semiconductor fuses
Line paralleling module IP00, 500 … 690 V APM1L0LPMY6 40.0/
APM1L0LFMY6 b 6- or 12-pulse supply 88.2
b 1 x paralleling choke
b 3 x semiconductor fuses
Line filter
Line filter module IP00, 380 … 480 V APM1L0LFMN4 6.5/
b EMC filter 14.3
Line filter module IP00, 500 … 690 V APM1L0LFMY6 6.5/
b EMC filter 14.3

26
References (continued) Variable speed drives
Altivar Process Modular
Sub-assemblies and accessories

Additional modules for liquid-cooled drives (continued)


ATVM_CP19035B

Description Reference Weight


kg/lb
Line choke
Line choke module IP00, 380 … 480 V APM1L0LCMN4 183/
b 6- or 12-pulse supply 404
b 2 x three-phase line reactors
b 6 x semiconductor fuses
b EMC filter
Line choke module IP00, 500 … 690 V APM1L0LCMY6 183/
b 6- or 12-pulse supply 404
b 2 x three-phase line reactors
b 6 x semiconductor fuses
b EMC filter
Motor protection
Motor protection module IP00, 380 … 480 V APM1L0MPMN4 32.5/
APMBC0C63Y6 b 1 x dv/dt filter and common mode filter 71.7
b Integrated motor terminals
Motor protection module IP00, 500 … 690 V APM1L0MPMY6 32.5/
ATVM_CP19041

b 1 x dv/dt filter and common mode filter 71.7


b Integrated motor terminals
Cabinet cooling
Cabinet cooling module IP00, 115 VAC APM1L0CCM115 13.5/
b Air/water heat exchanger with fan 29.8
Cabinet cooling module IP00, 230 VAC APM1L0CCM230 13.5/
b Air/water heat exchanger with fan 29.8
APMBC0CTLY6
Braking modules
Description Reference Weight
kg/lb
Braking module for APM 380…480 V: APMBC0C50N4 95/
b 1 x power unit 209
b 1 x air outlet unit
b 2 x brackets with nuts for front mechanical connection
Braking module for APM 500…690 V: APMBC0C63Y6 95/
b 1 x power unit 209
b 1 x air outlet unit
b 2 x brackets with nuts for front mechanical connection
Overall dimensions
Reference WxHxD
mm in.
APMBC0C50N4 750 x 1,360 x 700 29.53 x 53.54 x 27.56
APMBC0C63Y6

Control units for braking unit


Description Reference Weight
kg/lb
Control unit for braking unit 380…480 V APMBC0CTLN4 6.7/
14.8
Control unit for braking unit 500...690 V APMBC0CTLY6 6.7/
14.8
Overall dimensions
Reference WxHxD
mm in.
APMBC0CTLN4 287 x 735 x 178 11.30 x 28.94 x 7.01
APMBC0CTLY6

27
Presentation, Variable speed drives
references Altivar Process Modular
Options: Wear parts, configuration and runtime tools

Wear parts
ATVM_65654_CPSCT18006

Description Reference Weight


kg/lb
VX5VAM001 Power fan kit VX5VAM001 1.420/
3.130
Drive power fan kit VX5VAML001 0.7/
1.543
Cabinet cooling fan kit, 115 V a VX5VAML003 1.4/
3.086
Cabinet cooling fan kit, 230 V a VX5VAML002 1.4/
3.086

SoMove software for Altivar Process Modular


Presentation
SoMove software for PC is used to configure, set up, and maintain Altivar Process
drives.

In addition to the standard features offered by SoMove software, such as the


oscilloscope function for accurate display of data samples or access to multi-drive
applications, the following features are accessible to partners of Altivar Process
Modular drives:

b F irst-time drive setting including architecture identification and validation, main


voltage and nominal power range setting, and operational reference creation,
which is the identity card of the configuration
b Serial number generation for the built modular drive
b Activation of warranty by registering the built modular drive in the Schneider
SoMove software Electric Partner Database
b Start-up and and maintenance of the built modular drive

For more information on SoMove setup software, please consult the SoMove Setup
software for motor control devices catalog.

Presentation: Variable speed drives: Combinations: Dimensions:


page 10 page 30 page 80 page 20

28
References Variable speed drives
Altivar Process Modular
Options: Graphic display terminal, communication
accessory

Graphic display terminal (supplied with the drive)


References
Description Reference Weight
kg/
lb
Graphic display terminal VW3A1111 0.200/
0.441

Graphic display terminal


(example shows dynamic pump operation in relation to its
optimum operation)

Communication accessory
Description Reference Weight
kg/
lb
Wi-Fi dongle TCSEGWB131W 0.134/
Portable battery-powered Wi-Fi access point for Wi-Fi equipment 0.295
(PC, tablet, smartphone, etc.)

Instant access to online help

References
Description Length IP rating Reference Weight
m/ kg/
ft lb
Remote mounting kit – 65/UL Type VW3A1112 –
Order with remote-mounting 12
cordset VW3A1104Rppp

Tightening tool – – ZB5AZ905 0.016/


for remote mounting kit 0.035

Remote-mounting cordset 1/ – VW3A1104R10 0.050/


equipped with 2 RJ45 connectors 3.28 0.110
Remote mounting kit for mounting graphic display terminal
on enclosure door (front panel) 3/ – VW3A1104R30 0.150/
9.84 0.331

5/ – VW3A1104R50 0.250/
16.4 0.551

10/ – VW3A1104R100 0.500/


33 1.102

IP65 remote mounting kit for – 65 VW3A1115 0.018/


Ethernet port (1) 0.040
Ø 22 RJ45 female/female adapter
with seal
(1) Used to connect a remote PC to the RJ45 port on an IP21 drive mounted in an enclosure.
Drill hole with a standard Ø 22 tool, as used for a pushbutton (requires a remote-mounting
Remote mounting kit for graphic display terminal (rear panel) cordset VW3A1104Rppp equipped with 2 RJ45 connectors).

Presentation: Variable speed drives: Combinations: Dimensions:


page 10 page 30 page 80 page 20

29
Presentation Variable speed drives
Altivar Process Modular

Modular drives
Modular drive solutions can be built using power modules, control units, and
accessories. They cover motor power ratings from 75…2600 kW/125…2600 HP
for 380…690 V three-phase voltages.

Three-phase power supply - 380…480 V (-15…10%) Standard


Motor power Degree of protection Reference
110…800 kW IP00 ATV6A0C11p4…C80p4
150…1100 HP ATV9A0C11p4…C80p4

Three-phase power supply 500 V (-10…15%), 600…690 V (-15…10%) Standard


Motor power Degree of protection Reference
75…1200 kW IP00 ATV6A0C11p6…M12p6
125…1200 HP ATV9A0C11p6…M12p6

Three-phase power supply - 380…440 V (-15…10%), 480 V (-10…10%) Low Harmonic


Motor power Degree of protection Reference
Altivar Process Modular Standard architecture from 1 to 6
modules 110…800 kW IP00 ATV6B0C11p4…C80p4
150…1100 HP ATV9B0C11p4…C80p4

Three-phase power supply 500 V (-15…10%), 600…690 V (-10…10%) Low Harmonic


Motor power Degree of protection Reference
75…1200 kW IP00 ATV6B0C11p6…M12p6
125…1200 HP ATV9B0C11p6…M12p6

Liquid-cooled three-phase power supply - 400 V…480 V (-15…10%) Standard


Motor power Degree of protection Reference
132…1800 kW IP00 ATV6L0C13p4…M18p4
200…2500 HP ATV9L0C13p4…M18p4

Liquid-cooled three-phase power supply - 500 V…690 V (-15…10%) Standard


Motor power Degree of protection Reference
132…2600 kW IP00 ATV6L0C20p6…M26p6
200…2600 HP ATV9L0C20p6…M26p6

Altivar Process Modular Low Harmonic/Regen architecture


from 1 to 6 modules

+ 20% (ATV900) + 50% Altivar Process Modular variable speed drives are designed for use in two operating
+ 10% (ATV600) modes that can optimize the drive nominal rating according to the system
P nominal constraints.
These two modes are:
P nominal - 1 b Normal duty (ND): Dedicated mode for applications requiring a slight overload
(up to 110% for ATV600 and 120% for ATV900) with a motor power no higher
than the drive nominal power
b Heavy duty (HD): Dedicated mode for applications requiring a significant
overload (up to 150% for both ATV600 and ATV900) with a motor power no
higher than the drive nominal power derated by one rating

Power/current
Normal duty
Heavy duty
Normal duty and Heavy duty modes

30
Presentation (continued) Variable speed drives
Altivar Process Modular
Architectures

Architectures
Altivar Process Modular drives can be integrated into cabinets with the following dimensions:
b 2,000 mm/78.7 in. height for standard cabinets or 1,600 mm/63 in., height for Reduced Height cabinets
b 600 mm/23.6 in. depth
b Four different widths: 400 mm/15.7 in., 600 mm/23.6 in., 800 mm/31.5 in., and 1,000 mm/39.4 in.

For a 380..480 V line supply, there are five different kinds of Standard and Reduced Height architectures for Standard or Low Harmonic/Regen
drives with a power range from 110 to 800 kW (150 to 1100 HP).

For a 500…690 V line supply, there are six different kinds of Standard and Reduced Height architectures for Standard, Low Harmonic/Regen,
or Liquid-cooled drives from 75 to 2600 kW (125 to 2600 HP).

Architectures with braking exist on all the Standard drive ranges. For the Low Harmonic/Regen drive architectures, there are three different kinds of
architecture with a power range from 110 to 500 kW (150 to 700 HP) for a 380..480 V line supply and 75 to 630 kW (125 to 650 HP) for a 500…690 V line
supply.
Please refer to the combinations table (see page 80) to learn more about the possible architectures.
Standard drive solutions without braking - Standard architectures

1 x APM 2 x APM 3 x APM 4 x APM 5 x APM 6 x APM


400 mm width 600 mm width 800 mm width 1,200 mm width 1,400 mm width 1,600 mm width

380…480 V 110 to 160 kW 200 to 315 kW 355 to 500 kW 560 to 630 kW 710 to 800 kW –
500…690 V 75 to 200 kW 160 to 400 kW 355 to 630 kW 560 to 800 kW 710 to 1000 kW 800 to 1200 kW

Top air duct Line supply bars kits


Bottom air duct Digi-Link cables
and support
DC connection bar kits
400 mm width 600 mm width 800 mm width Power module Control unit Set of 3 fuses Motor busbar kits

Standard drive solutions with braking - Standard architectures

400 mm width 600 mm width 800 mm width

1 x APM 2 x APM 3 x APM 4 x APM


1 x BM 1 x BM 1 x BM 2 x BM Power module Control unit
600 mm width 800 mm width 1,200 mm width 1,600 mm width

400 V 110 to 160 kW 200 to 315 kW 355 to 500 kW 560 to 630 kW


690 V 75 to 200 kW 160 to 400 kW 355 to 630 kW 560 to 800 kW

Braking module Control unit

Top air duct


Bottom air duct
and support

Set of 3 fuses

Line supply bars kits


Digi-Link cables
5 x APM 6 x APM
Module link cables
2 x BM 2 x BM
2,000 mm width 2,200 mm width DC connection bar kits
Motor busbar kits
400 V 710 to 800 kW –
690 V 710 to 1000 kW 800 to 1200 kW

31
Presentation (continued) Variable speed drives
Altivar Process Modular
Architectures

Architectures (continued)
Standard drive solution without braking - Reduced Height architectures

600 mm width 800 mm width

1 x APM 2 x APM 3 x APM 4 x APM Reduced Height Mains module


800 mm width 1,200 mm width 1,400 mm width 2,400 mm width power module (3 models):
400 V 110 to 160 kW 200 to 315 kW 355 to 500 kW 560 to 630 kW 1 x line choke
2 x line chokes
690 V 110 to 200 kW 250 to 400 kW 500 to 630 kW 800 kW 3 x line chokes

Control unit

Top air duct


Bottom air duct
and support

5 x APM 6 x APM 3-phase mains cabling


2,600 mm width 2,800 mm width Digi-Link cables
400 V 710 to 800 kW – DC connection bar kits
690 V 1000 kW 1200 kW Motor busbar kits

Standard drive solution with braking - Reduced Height architectures

1 x APM 2 x APM 3 x APM 4 x APM


1 x BM 1 x BM 1 x BM 2 x BM
1,200 mm width 1,400 mm width 1,800 mm width 3,000 mm width
400 V 110 to 160 kW 200 to 315 kW 355 to 500 kW 560 to 630 kW
690 V 110 to 200 kW 250 to 400 kW 500 to 630 kW 800 kW

5 x APM 6 x APM
2 x BM 2 x BM
3,200 mm width 3,400 mm width
400 V 710 to 800 kW –
690 V 1000 kW 1200 kW

Top air duct 3-phase mains cabling


Bottom air duct Digi-Link cables
and support DC connection bar kits
600 mm 800 mm Reduced Braking Braking Mains module Control unit
Top outlet cooling Motor busbar kits
width width Height module control unit (3 models):
power 1 x line choke Module link cables
module 2 x line chokes
3 x line chokes

32
Presentation (continued) Variable speed drives
Altivar Process Modular
Architectures

Architectures (continued)
Low Harmonic/Regen drive solutions without braking - Standard architectures

600 mm width 1,000 mm width

1 x APM 2 x APM 3 x APM 4 x APM


600 mm width 1,000 mm width 1,600 mm width 2,000 mm width
380…480 V 110 to 160 kW 200 to 315 kW 355 to 500 kW 560 to 630 kW Power module Control unit
500…690 V 75 to 200 kW 160 to 400 kW 355 to 630 kW 560 to 800 kW

Top air duct

Air duct
Set of 3 fuses

Line supply bars kits


Module link cables
Digi-Link cables
DC connection bar kits
Motor busbar kits
5 x APM 6 x APM
2,600 mm width 3,000 mm width
380…480 V 710 to 800 kW –
500…690 V 710 to 1000 kW 800 to 1200 kW

Low Harmonic/Regen drive solutions with braking - Standard architectures

400 mm width

600 mm width 1,000 mm width

1 x APM 2 x APM 3 x APM


1 x BM 1 x BM 1 x BM
1,000 mm width 1,400 mm width 2,000 mm width Power module Control unit

400 V 110 to 160 kW 200 to 315 kW 355 to 500 kW

Braking module Control unit


Top air duct
Air duct

Set of 3 fuses
Bottom air duct
and support

Line supply bars kits


4 x APM 5 x APM
1 x BM 1 x BM Module link cables
2,400 mm width 3,000 mm width Digi-Link cables
400 V 560 to 630 kW 710 to 800 kW DC connection bar kits
Motor busbar kits

33
Presentation (continued) Variable speed drives
Altivar Process Modular
Architectures

Architectures (continued)
Liquid-cooled drive solutions – Standard architectures - Compact

1 x STD PM 2 x STD PM 3 x STD PM 4 x STD PM 5 x STD PM 6 x STD PM


400 mm width 600 mm width 800 mm width 1,200 mm width 1,400 mm width 1,600 mm width

400 V 132 to 315 kW 400 to 630 kW 800 to 900 kW 1000 to 1200 kW 1500 kW 1800 kW
690 V 200 to 450 kW 560 to 900 kW 1200 to 1400 kW 1600 to 1800 kW 2200 kW 2600 kW

Line filter module Mains supply


Motor protection Digi-Link cables
module
Connection kits
Line paralleling
400 mm width 600 mm width 800 mm width Power module Control unit module (incl. 6 fuses) Liquid cooling

Liquid-cooled drive solutions – Standard architectures - Universal

1 x STD PM 2 x STD PM 3 x STD PM 4 x STD PM 5 x STD PM 6 x STD PM


600 mm width 1,200 mm width 1,800 mm width 2,400 mm width 3,000 mm width 3,600 mm width

400 V 132 to 315 kW 400 to 630 kW 800 to 900 kW 1000 to 1200 kW 1500 kW 1800 kW
690 V 200 to 450 kW 560 to 900 kW 1200 to 1400 kW 1600 to 1800 kW 2200 kW 2600 kW

Cabinet cooling module Mains supply


Digi-Link cables
Motor protection module
Connection kits
600 mm width Power module Control unit Line choke module
(incl. 6 fuses) Liquid cooling

Motor starters
Schneider Electric offers combinations of circuit breakers and contactors to be able to use Altivar Process Modular drives in optimum
conditions (see page 94).

34
References Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 400 V 50/60 Hz

400 V (-15...10%) IP00 Modular Standard drives (1)


ATVM_CP19044

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
400 V 400 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 48% at 100% load in Normal duty
ND 110 – 198 137 50 211 232 ATV6A0C11Q4
HD 90 – 167 116 50 173 260
ATV6A0C11Q4
ND 132 – 233 161 50 250 275 ATV6A0C13Q4
HD 110 – 198 137 50 211 317
ND 160 – 278 193 50 302 332 ATV6A0C16Q4
HD 132 – 233 161 50 250 375
ND 200 – 352 244 50 370 407 ATV6A0C20Q4
HD 160 – 290 201 50 302 453
ATVM_CP19049

ND 250 – 432 299 50 477 525 ATV6A0C25Q4


HD 200 – 353 245 50 370 555
ND 315 – 538 373 50 590 649 ATV6A0C31Q4
HD 250 – 432 299 50 477 716
ND 355 – 611 423 50 660 726 ATV6A0C35Q4
HD 280 – 489 339 50 520 780
ND 400 – 681 472 50 730 803 ATV6A0C40Q4
HD 315 – 545 378 50 590 885
ND 450 – 764 529 50 830 913 ATV6A0C45Q4
HD 355 – 611 423 50 660 990
ND 500 – 846 586 50 900 990 ATV6A0C50Q4
HD 400 – 681 472 50 730 1095
ATV6A0C25Q4 ND 560 – 948 657 50 1020 1122 ATV6A0C56Q4
HD 450 – 767 531 50 830 1245
ND 630 – 1058 733 50 1140 1254 ATV6A0C63Q4
HD 500 – 849 588 50 900 1350
ND 710 – 1192 826 50 1260 1386 ATV6A0C71Q4
HD 560 – 951 659 50 1020 1530
ND 800 – 1335 925 50 1420 1562 ATV6A0C80Q4
HD 630 – 1061 735 50 1140 1710

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

35
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 400 V 50/60 Hz

400 V (-15...10%) IP00 Modular Standard drives (continued) (1)


ATVM_CP19044

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
400 V 400 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 48% at 100% load in Normal duty
ND 110 – 198 135 50 211 253 ATV9A0C11Q4
HD 90 – 167 114 50 173 260
ATV9A0C16Q4
ND 132 – 233 161 50 250 300 ATV9A0C13Q4
HD 110 – 198 136 50 211 317
ND 160 – 278 192 50 302 362 ATV9A0C16Q4
HD 132 – 233 161 50 250 375
ND 200 – 352 242 50 370 444 ATV9A0C20Q4
HD 160 – 290 198 50 302 453
ATVM_CP19049

ND 250 – 432 299 50 477 572 ATV9A0C25Q4


HD 200 – 353 245 50 370 555
ND 315 – 538 373 50 590 708 ATV9A0C31Q4
HD 250 – 432 299 50 477 716
ND 355 – 611 423 50 660 792 ATV9A0C35Q4
HD 280 – 489 339 50 520 780
ND 400 – 681 472 50 730 876 ATV9A0C40Q4
HD 315 – 545 378 50 590 885
ND 450 – 764 529 50 830 996 ATV9A0C45Q4
HD 355 – 611 423 50 660 990
ND 500 – 846 586 50 900 1080 ATV9A0C50Q4
HD 400 – 681 472 50 730 1095
ATV9A0C20Q4 ND 560 – 948 657 50 1020 1224 ATV9A0C56Q4
HD 450 – 767 531 50 830 1245
ND 630 – 1058 733 50 1140 1368 ATV9A0C63Q4
HD 500 – 849 588 50 900 1350
ND 710 – 1192 826 50 1260 1512 ATV9A0C71Q4
HD 560 – 951 659 50 1020 1530
ND 800 – 1335 925 50 1420 1704 ATV9A0C80Q4
HD 630 – 1061 735 50 1140 1710

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

36
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 440 V 50/60 Hz

440 V (-15...10%) IP00 Modular Standard drives (1)


ATVM_CP19049

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
440 V 440 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 48% at 100% load in Normal duty
ND 110 – 183 139 50 211 232 ATV6A0C11R4
HD 90 – 155 118 50 173 260
ATV6A0C20R4
ND 132 – 214 163 50 250 275 ATV6A0C13R4
HD 110 – 183 139 50 211 317
ND 160 – 255 194 50 302 332 ATV6A0C16R4
HD 132 – 214 163 50 250 375
ND 160 – 325 248 50 370 407 ATV6A0C20R4
ATVM_OP19050

HD 160 – 269 205 50 302 453


ND 250 – 396 302 50 477 525 ATV6A0C25R4
HD 200 – 325 248 50 370 555
ND 315 – 493 376 50 590 649 ATV6A0C31R4
HD 250 – 396 302 50 477 716
ND 355 – 559 426 50 660 726 ATV6A0C35R4
HD 280 – 450 343 50 520 780
ND 400 – 623 475 50 730 803 ATV6A0C40R4
HD 315 – 501 382 50 590 885
ND 450 – 697 531 50 830 913 ATV6A0C45R4
HD 355 – 559 426 50 660 990
ND 500 – 771 588 50 900 990 ATV6A0C50R4
ATV6A0C35R4 HD 400 – 623 475 50 730 1095
ND 560 – 865 659 50 1020 1122 ATV6A0C56R4
HD 450 – 703 536 50 830 1245
ND 630 – 965 735 50 1140 1254 ATV6A0C63R4
HD 500 – 776 591 50 900 1350
ND 710 – 1087 828 50 1260 1386 ATV6A0C71R4
HD 580 – 869 662 50 1020 1530
ND 800 – 1216 927 50 1420 1562 ATV6A0C80R4
HD 630 – 968 738 50 1140 1710

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

37
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 440 V 50/60 Hz

440 V (-15...10%) IP00 Modular Standard drives (continued) (1)


ATVM_CP19049

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
440 V 440 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 48% at 100% load in Normal duty
ND 110 – 183 136 50 211 253 ATV9A0C11R4
HD 90 – 155 115 50 173 260
ATV9A0C31R4
ND 132 – 214 162 50 250 300 ATV9A0C13R4
HD 110 – 183 138 50 211 317
ND 160 – 255 194 50 302 362 ATV9A0C16R4
HD 132 – 214 162 50 250 375
ND 160 – 325 245 50 370 444 ATV9A0C20R4
ATVM_OP19050

HD 160 – 269 201 50 302 453


ND 250 – 396 302 50 477 572 ATV9A0C25R4
HD 200 – 325 248 50 370 555
ND 315 – 493 376 50 590 708 ATV9A0C31R4
HD 250 – 396 302 50 477 716
ND 355 – 559 426 50 660 792 ATV9A0C35R4
HD 280 – 450 343 50 520 780
ND 400 – 623 475 50 730 876 ATV9A0C40R4
HD 315 – 501 382 50 590 885
ND 450 – 697 531 50 830 996 ATV9A0C45R4
HD 355 – 559 426 50 660 990
ND 500 – 771 588 50 900 1080 ATV9A0C50R4
ATV9A0C40R4 HD 400 – 623 475 50 730 1095
ND 560 – 865 659 50 1020 1224 ATV9A0C56R4
HD 450 – 703 536 50 830 1245
ND 630 – 965 735 50 1140 1368 ATV9A0C63R4
HD 500 – 776 591 50 900 1350
ND 710 – 1087 828 50 1260 1512 ATV9A0C71R4
HD 580 – 869 662 50 1020 1530
ND 800 – 1216 927 50 1420 1704 ATV9A0C80R4
HD 630 – 968 738 50 1140 1710

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

38
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 480 V 50/60 Hz

480 V (-15...10%) IP00 Modular Standard drives (1)


ATVM_OP19051

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
480 V 480 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 48% at 100% load in Normal duty
ND – 150 168 140 50 211 232 ATV6A0C11T4
HD – 125 145 121 50 173 260
ATV6A0C56T4
ND – 200 218 181 50 250 275 ATV6A0C13T4
HD – 150 168 140 50 211 317
ND – 250 268 223 50 302 332 ATV6A0C16T4
HD – 200 218 181 50 250 375
ND – 300 328 273 50 370 407 ATV6A0C20T4
ATVM_OP19052

HD – 250 280 233 50 302 453


ND – 400 427 355 50 477 525 ATV6A0C25T4
HD – 300 328 273 50 370 555
ND – 500 528 439 50 590 649 ATV6A0C31T4
HD – 400 427 355 50 477 716
ND – 550 586 487 50 660 726 ATV6A0C35T4
HD – 450 486 404 50 520 780
ND – 600 634 527 50 730 803 ATV6A0C40T4
HD – 500 536 446 50 590 885
ND – 650 685 569 50 830 913 ATV6A0C45T4
HD – 550 586 487 50 660 990
ND – 700 736 612 50 900 990 ATV6A0C50T4
ATV6A0C80T4 HD – 600 634 527 50 730 1095
ND – 800 842 700 50 1020 1122 ATV6A0C56T4
HD – 650 690 574 50 830 1245
ND – 900 939 781 50 1140 1254 ATV6A0C63T4
HD – 700 740 615 50 900 1350
ND – 1000 1044 868 50 1260 1386 ATV6A0C71T4
HD – 800 846 703 50 1020 1530
ND – 1100 1146 953 50 1420 1562 ATV6A0C80T4
HD – 900 942 783 50 1140 1710

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

39
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 480 V 50/60 Hz

480 V (-15...10%) IP00 Modular Standard drives (continued) (1)


ATVM_OP19051

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
480 V 480 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 48% at 100% load in Normal duty
ND – 150 168 138 50 211 253 ATV9A0C11T4
HD – 125 145 118 50 173 260
ATV9A0C63T4
ND – 200 218 180 50 250 300 ATV9A0C13T4
HD – 150 168 140 50 211 317
ND – 250 268 223 50 302 362 ATV9A0C16T4
HD – 200 218 180 50 250 375
ND – 300 328 271 50 370 444 ATV9A0C20T4
ATVM_OP19052

HD – 250 280 230 50 302 453


ND – 400 427 355 50 477 572 ATV9A0C25T4
HD – 300 328 273 50 370 555
ND – 500 528 439 50 590 708 ATV9A0C31T4
HD – 400 427 355 50 477 716
ND – 550 586 487 50 660 792 ATV9A0C35T4
HD – 450 486 404 50 520 780
ND – 600 634 527 50 730 876 ATV9A0C40T4
HD – 500 536 446 50 590 885
ND – 650 685 569 50 830 996 ATV9A0C45T4
HD – 550 586 487 50 660 990
ND – 700 736 612 50 900 1080 ATV9A0C50T4
ATV9A0C80T4 HD – 600 634 527 50 730 1095
ND – 800 842 700 50 1020 1224 ATV9A0C56T4
HD – 650 690 574 50 830 1245
ND – 900 939 781 50 1140 1368 ATV9A0C63T4
HD – 700 740 615 50 900 1350
ND – 1000 1044 868 50 1260 1512 ATV9A0C71T4
HD – 800 846 703 50 1020 1530
ND – 1100 1146 953 50 1420 1704 ATV9A0C80T4
HD – 900 942 783 50 1140 1710

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

40
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 500 V 50/60 Hz

500 V (-10...15%) IP00 Modular Standard drives (1)


ATVM_CP19044

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
500 V 500 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 48% at 100% load in Normal duty
ND 75 – 110 95 50 125 138 ATV6A0C11N6
HD 55 – 83 72 50 105 158
ATV6A0C11N6
ND 90 – 129 112 50 145 160 ATV6A0C13N6
HD 75 – 110 95 50 125 188
ND 110 – 154 133 50 175 193 ATV6A0C16N6
HD 90 – 129 112 50 145 218
ND 132 – 183 158 50 215 237 ATV6A0C20N6
HD 110 – 154 133 50 175 263
ATVM_CP19049

ND 160 – 225 195 50 275 303 ATV6A0C25N6


HD 132 – 190 165 50 215 323
ND 220 – 303 262 50 340 374 ATV6A0C31N6
HD 160 – 225 195 50 275 413
ND 280 – 380 329 50 425 468 ATV6A0C40N6
HD 220 – 303 262 50 340 510
ND 355 – 484 419 50 520 572 ATV6A0C50N6
HD 280 – 385 333 50 425 638
ND 450 – 607 526 50 650 715 ATV6A0C63N6
HD 355 – 484 419 50 520 780
ND 560 – 756 655 50 830 913 ATV6A0C80N6
HD 450 – 610 528 50 650 975
ATV6A0C25N6 ND 710 – 954 826 50 1030 1133 ATV6A0M10N6
HD 560 – 758 656 50 830 1245
ND 800 – 1070 927 50 1230 1353 ATV6A0M12N6
HD 710 – 954 826 50 1030 1545

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

41
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 500 V 50/60 Hz

500 V (-10...15%) IP00 Modular Standard drives (continued) (1)


ATVM_CP19044

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
500 V 500 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 48% at 100% load in Normal duty
ND 75 – 110 95 50 125 150 ATV9A0C11N6
HD 55 – 83 72 50 105 158
ATV9A0C11N6
ND 90 – 129 112 50 145 174 ATV9A0C13N6
HD 75 – 110 95 50 125 188
ND 110 – 154 133 50 175 210 ATV9A0C16N6
HD 90 – 129 112 50 145 218
ND 132 – 183 158 50 215 258 ATV9A0C20N6
HD 110 – 154 133 50 175 263
ATVM_CP19049

ND 160 – 225 195 50 275 330 ATV9A0C25N6


HD 132 – 190 165 50 215 323
ND 220 – 303 262 50 340 408 ATV9A0C31N6
HD 160 – 225 195 50 275 413
ND 280 – 380 329 50 425 510 ATV9A0C40N6
HD 220 – 303 262 50 340 510
ND 355 – 484 419 50 520 624 ATV9A0C50N6
HD 280 – 385 333 50 425 638
ND 450 – 607 526 50 650 780 ATV9A0C63N6
HD 355 – 484 419 50 520 780
ND 560 – 756 655 50 830 996 ATV9A0C80N6
HD 450 – 610 528 50 650 975
ATV9A0C25N6 ND 710 – 954 826 50 1030 1236 ATV9A0M10N6
HD 560 – 758 656 50 830 1245
ND 800 – 1070 927 50 1230 1476 ATV9A0M12N6
HD 710 – 954 826 50 1030 1545

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

42
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 600 V 50/60 Hz

600 V (-15...10%) IP00 Modular Standard drives (1)


ATVM_OP19050

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
(4) 60 s
600 V 600 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 48% at 100% load in Normal duty
ND – 125 112 116 50 125 138 ATV6A0C11T6
HD – 100 92 96 50 105 158
ATV6A0C50T6
ND – 150 131 136 50 145 160 ATV6A0C13T6
HD – 125 112 116 50 125 188
ND – 175 152 158 50 175 193 ATV6A0C16T6
HD – 150 131 136 50 145 218
ND – 200 172 179 50 215 237 ATV6A0C20T6
ATVM_OP19051

HD – 175 152 158 50 175 263


ND – 250 218 227 50 275 303 ATV6A0C25T6
HD – 200 179 186 50 215 323
ND – 350 298 310 50 340 374 ATV6A0C31T6
HD – 250 218 227 50 275 413
ND – 450 379 394 50 425 468 ATV6A0C40T6
HD – 350 298 310 50 340 510
ND – 550 464 482 50 520 572 ATV6A0C50T6
HD – 450 383 398 50 425 638
ND – 650 544 565 50 650 715 ATV6A0C63T6
HD – 550 464 482 50 520 780
ND – 800 670 696 50 830 913 ATV6A0C80T6
ATV6A0C80T6
HD – 650 547 568 50 650 975
ND – 1000 833 866 50 1030 1133 ATV6A0M10T6
HD – 800 673 699 50 830 1245
ND – 1200 994 1033 50 1230 1353 ATV6A0M12T6
HD – 1000 835 835 50 1030 1545

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) For 600V UL certified drives, a higher SCCR is possible under some conditions. Please refer to the Integration Manual
PHA2451702 for more details.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

43
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 600 V 50/60 Hz

600 V (-15...10%) IP00 Modular Standard drives (continued) (1)


ATVM_OP19050

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
(4) 60 s
600 V 600 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 48% at 100% load in Normal duty
ND – 125 112 116 50 125 150 ATV9A0C11T6
HD – 100 92 96 50 105 158
ATV9A0C50T6
ND – 150 131 136 50 145 174 ATV9A0C13T6
HD – 125 112 116 50 125 188
ND – 175 152 158 50 175 210 ATV9A0C16T6
HD – 150 131 136 50 145 218
ND – 200 172 179 50 215 258 ATV9A0C20T6
ATVM_OP19051

HD – 175 152 158 50 175 263


ND – 250 218 227 50 275 330 ATV9A0C25T6
HD – 200 179 186 50 215 323
ND – 350 298 310 50 340 408 ATV9A0C31T6
HD – 250 218 227 50 275 413
ND – 450 379 394 50 425 510 ATV9A0C40T6
HD – 350 298 310 50 340 510
ND – 550 464 482 50 520 624 ATV9A0C50T6
HD – 450 383 398 50 425 638
ND – 650 544 565 50 650 780 ATV9A0C63T6
HD – 550 464 482 50 520 780
ND – 800 670 696 50 830 996 ATV9A0C80T6
ATV9A0C80T6
HD – 650 547 568 50 650 975
ND – 1000 833 866 50 1030 1236 ATV9A0M10T6
HD – 800 673 699 50 830 1245
ND – 1200 994 1033 50 1230 1476 ATV9A0M12T6
HD – 1000 835 835 50 1030 1545

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) For 600V UL certified drives, a higher SCCR is possible under some conditions. Please refer to the Integration Manual
PHA2451702 for more details.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

44
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 690 V 50/60 Hz

690 V (-15...10%) IP00 Modular Standard drives (1)


ATVM_OP19052

Motor Line supply Altivar Process


Power indicated on rating plate Line Apparent Maximum Maximum Max. Reference
(2) current (3) power prospective continuous transient
line Isc current (2) current for
60 s
690 V 690 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 48% at 100% load in Normal duty
ND 110 – 118 141 50 125 138 ATV6A0C11Q6
HD 90 – 100 120 50 105 158
ATV6A0M10Q6
ND 132 – 138 165 50 145 160 ATV6A0C13Q6
HD 110 – 118 141 50 125 188
ND 160 – 163 195 50 175 193 ATV6A0C16Q6
HD 132 – 138 165 50 145 218
ND 200 – 200 239 50 215 237 ATV6A0C20Q6
ATVM_OP19053

HD 160 – 163 195 50 175 263


ND 250 – 255 305 50 275 303 ATV6A0C25Q6
HD 200 – 211 252 50 215 323
ND 315 – 316 378 50 340 374 ATV6A0C31Q6
HD 250 – 255 305 50 275 413
ND 400 – 394 471 50 425 468 ATV6A0C40Q6
HD 315 – 316 378 50 340 510
ND 500 – 495 592 50 520 572 ATV6A0C50Q6
HD 400 – 401 479 50 425 638
ND 630 – 615 735 50 650 715 ATV6A0C63Q6
HD 500 – 495 592 50 520 780

ATV6A0M12Q6 ND 800 – 776 927 50 830 913 ATV6A0C80Q6


HD 630 – 619 740 50 650 975
ND 1000 – 969 1158 50 1030 1133 ATV6A0M10Q6
HD 800 – 779 931 50 830 1245
ND 1200 – 1161 1388 50 1230 1353 ATV6A0M12Q6
HD 1000 – 971 1160 50 1030 1545

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft
cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

45
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 690 V 50/60 Hz

690 V (-15...10%) IP00 Modular Standard drives (continued) (1)


ATVM_OP19052

Motor Line supply Altivar Process


Power indicated on rating plate Line Apparent Maximum Maximum Max. Reference
(2) current power prospective continuous transient
(3) line Isc current (2) current for
60 s
690 V 690 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 48% at 100% load in Normal duty
ND 110 – 118 141 50 125 150 ATV9A0C11Q6
HD 90 – 100 120 50 105 158
ATV9A0M10Q6
ND 132 – 138 165 50 145 174 ATV9A0C13Q6
HD 110 – 118 141 50 125 188
ND 160 – 163 195 50 175 210 ATV9A0C16Q6
HD 132 – 138 165 50 145 218
ND 200 – 200 239 50 215 258 ATV9A0C20Q6
ATVM_OP19053

HD 160 – 163 195 50 175 263


ND 250 – 255 305 50 275 330 ATV9A0C25Q6
HD 200 – 211 252 50 215 323
ND 315 – 316 378 50 340 408 ATV9A0C31Q6
HD 250 – 255 305 50 275 413
ND 400 – 394 471 50 425 510 ATV9A0C40Q6
HD 315 – 316 378 50 340 510
ND 500 – 495 592 50 520 624 ATV9A0C50Q6
HD 400 – 401 479 50 425 638
ND 630 – 615 735 50 650 780 ATV9A0C63Q6
HD 500 – 495 592 50 520 780

ATV9A0M12Q6 ND 800 – 776 927 50 830 996 ATV9A0C80Q6


HD 630 – 619 740 50 650 975
ND 1000 – 969 1158 50 1030 1236 ATV9A0M10Q6
HD 800 – 779 931 50 830 1245
ND 1200 – 1161 1388 50 1230 1476 ATV9A0M12Q6
HD 1000 – 971 1160 50 1030 1545

(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual PHA2451702).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Note: Altivar Process Modular Standard drives can be designed as Reduced Height versions for integration in 1.6 m/5.25 ft
cabinets.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

46
References Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 400 V 50/60 Hz
ATVPro_62317_CPMGU180016

400 V (-15…10%) IP00 Modular Low Harmonic drives (1)


Motor Line supply Altivar Process
Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
400 V 400 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 5% at 100% load in Normal duty
ND 110 – 175 121 50 211 232 ATV6B0C11Q4
ATV6B0C11Q4
HD 90 – 144 100 50 173 260
ND 132 – 208 144 50 250 275 ATV6B0C13Q4
HD 110 – 174 121 50 211 317
ND 160 – 252 174 50 302 332 ATV6B0C16Q4
HD 132 – 208 144 50 250 375
ND 200 – 313 217 50 370 407 ATV6B0C20Q4
HD 160 – 252 174 50 302 453
ATVPro_CP19025

ND 250 – 389 270 50 477 525 ATV6B0C25Q4


HD 200 – 313 217 50 370 555
ND 315 – 491 340 50 590 649 ATV6B0C31Q4
HD 250 – 389 270 50 477 716
ND 355 – 553 383 50 660 726 ATV6B0C35Q4
HD 280 – 436 302 50 520 780
ND 400 – 620 429 50 730 803 ATV6B0C40Q4
HD 315 – 491 340 50 590 885
ND 450 – 697 483 50 830 913 ATV6B0C45Q4
HD 355 – 553 383 50 660 990
ND 500 – 775 537 50 900 990 ATV6B0C50Q4
ATV6B0C20Q4
HD 400 – 620 429 50 730 1095
ND 560 – 868 601 50 1020 1122 ATV6B0C56Q4
HD 450 – 697 483 50 830 1245
ND 630 – 971 673 50 1140 1254 ATV6B0C63Q4
HD 500 – 775 537 50 900 1350
ND 710 – 1094 758 50 1260 1386 ATV6B0C71Q4
HD 560 – 868 601 50 1020 1530
ND 800 – 1227 850 50 1420 1562 ATV6B0C80Q4
HD 630 – 971 673 50 1140 1710
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

47
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 400 V 50/60 Hz
ATVPro_62317_CPMGU180016

400 V (-15…10%) IP00 Modular Low Harmonic/Regen drives (1)


Motor Line supply Altivar Process
Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
400 V 400 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 5% at 100% load in Normal duty
ND 110 – 175 121 50 211 253 ATV9B0C11Q4
ATV9B0C13Q4
HD 90 – 144 100 50 173 260
ND 132 – 208 144 50 250 300 ATV9B0C13Q4
HD 110 – 174 121 50 211 317
ND 160 – 252 174 50 302 362 ATV9B0C16Q4
HD 132 – 208 144 50 250 375
ND 200 – 313 217 50 370 444 ATV9B0C20Q4
HD 160 – 252 174 50 302 453
ATVPro_CP19025

ND 250 – 389 270 50 477 572 ATV9B0C25Q4


HD 200 – 313 217 50 370 555
ND 315 – 491 340 50 590 708 ATV9B0C31Q4
HD 250 – 389 270 50 477 716
ND 355 – 553 383 50 660 792 ATV9B0C35Q4
HD 280 – 436 302 50 520 780
ND 400 – 620 429 50 730 876 ATV9B0C40Q4
HD 315 – 491 340 50 590 885
ND 450 – 697 483 50 830 996 ATV9B0C45Q4
HD 355 – 553 383 50 660 990
ND 500 – 775 537 50 900 1080 ATV9B0C50Q4
ATV9B0C25Q4
HD 400 – 620 429 50 730 1095
ND 560 – 868 601 50 1020 1224 ATV9B0C56Q4
HD 450 – 697 483 50 830 1245
ND 630 – 971 673 50 1140 1368 ATV9B0C63Q4
HD 500 – 775 537 50 900 1350
ND 710 – 1094 758 50 1260 1512 ATV9B0C71Q4
HD 560 – 868 601 50 1020 1530
ND 800 – 1227 850 50 1420 1704 ATV9B0C80Q4
HD 630 – 971 673 50 1140 1710
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

48
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 440 V 50/60 Hz

440 V (-15…10%) IP00 Modular Low Harmonic drives (1)


ATVPro_CP19026

Motor Line supply Altivar Process


Power indicated on rating plate Line Apparent Maximum Maximum Max. Reference
(2) current power prospec- continuous transient
(3) tive line Isc current (2) current for
60 s
440 V 440 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 5% at 100% load in Normal duty
ND 110 – 159 121 50 211 232 ATV6B0C11R4
ATV6B0C31R4
HD 90 – 132 100 50 173 260
ND 132 – 190 145 50 250 275 ATV6B0C13R4
HD 110 – 159 121 50 211 317
ND 160 – 229 174 50 302 332 ATV6B0C16R4
HD 132 – 190 145 50 250 375
ND 200 – 285 217 50 370 407 ATV6B0C20R4
HD 160 – 229 174 50 302 453
ATVPro_CP19027

ND 250 – 354 270 50 477 525 ATV6B0C25R4


HD 200 – 285 217 50 370 555
ND 315 – 446 340 50 590 649 ATV6B0C31R4
HD 250 – 354 270 50 477 716
ND 355 – 503 383 50 660 726 ATV6B0C35R4
HD 280 – 396 302 50 520 780
ND 400 – 563 429 50 730 803 ATV6B0C40R4
HD 315 – 446 340 50 590 885
ND 450 – 634 483 50 830 913 ATV6B0C45R4
HD 355 – 503 383 50 660 990
ND 500 – 704 537 50 900 990 ATV6B0C50R4
ATV6B0C56R4
HD 400 – 563 429 50 730 1095
ND 560 – 789 601 50 1020 1122 ATV6B0C56R4
HD 450 – 634 483 50 830 1245
ND 630 – 883 673 50 1140 1254 ATV6B0C63R4
HD 500 – 704 537 50 900 1350
ND 710 – 995 758 50 1260 1386 ATV6B0C71R4
HD 560 – 789 601 50 1020 1530
ND 800 – 1115 850 50 1420 1562 ATV6B0C80R4
HD 630 – 883 673 50 1140 1710
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

49
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 440 V 50/60 Hz

440 V IP00 (-15…10%) Modular Low Harmonic/Regen drives (1)


ATVPro_CP19026

Motor Line supply Altivar Process


Power indicated on rating plate Line Apparent Maximum Maximum Max. Reference
(2) current power prospec- continuous transient
(3) tive line Isc current (2) current for
60 s
440 V 440 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 5% at 100% load in Normal duty
ND 110 – 159 121 50 211 253 ATV9B0C11R4
ATV9B0C40R4
HD 90 – 132 100 50 173 260
ND 132 – 190 145 50 250 300 ATV9B0C13R4
HD 110 – 159 121 50 211 317
ND 160 – 229 174 50 302 362 ATV9B0C16R4
HD 132 – 190 145 50 250 375
ND 200 – 285 217 50 370 444 ATV9B0C20R4
HD 160 – 229 174 50 302 453
ATVPro_CP19027

ND 250 – 354 270 50 477 572 ATV9B0C25R4


HD 200 – 285 217 50 370 555
ND 315 – 446 340 50 590 708 ATV9B0C31R4
HD 250 – 354 270 50 477 716
ND 355 – 503 383 50 660 792 ATV9B0C35R4
HD 280 – 396 302 50 520 780
ND 400 – 563 429 50 730 876 ATV9B0C40R4
HD 315 – 446 340 50 590 885
ND 450 – 634 483 50 830 996 ATV9B0C45R4
HD 355 – 503 383 50 660 990
ND 500 – 704 537 50 900 1080 ATV9B0C50R4
ATV9B0C63R4 HD 400 – 563 429 50 730 1095
ND 560 – 789 601 50 1020 1224 ATV9B0C56R4
HD 450 – 634 483 50 830 1245
ND 630 – 883 673 50 1140 1368 ATV9B0C63R4
HD 500 – 704 537 50 900 1350
ND 710 – 995 758 50 1260 1512 ATV9B0C71R4
HD 560 – 789 601 50 1020 1530
ND 800 – 1115 850 50 1420 1704 ATV9B0C80R4
HD 630 – 883 673 50 1140 1710
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

50
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 480 V 50/60 Hz

480 V (-10…10%) IP00 Modular Low Harmonic drives (1)


ATVPro_CP19028

Motor Line supply Altivar Process


Power indicated on rating Line Apparent Maximum Maximum Max. Reference
plate (2) current power prospec- continuous transient
(3) tive line current (2) current
Isc for
480 V 480 V 60 s
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
ATV6B0C45T4
THDi ≤ 5% at 100% load in Normal duty
ND – 150 148 123 50 211 232 ATV6B0C11T4
HD – 125 125 104 50 173 260
ND – 200 197 164 50 250 275 ATV6B0C13T4
HD – 150 148 123 50 211 317
ND – 250 245 203 50 302 332 ATV6B0C16T4
HD – 200 197 164 50 250 375
ND – 300 292 243 50 370 407 ATV6B0C20T4
HD – 250 245 203 50 302 453
ATVPro_CP19023

ND – 400 387 322 50 477 525 ATV6B0C25T4


HD – 300 292 243 50 370 555
ND – 500 484 402 50 590 649 ATV6B0C31T4
HD – 400 387 322 50 477 716
ND – 550 533 443 50 660 726 ATV6B0C35T4
HD – 450 436 362 50 520 780
ND – 600 578 480 50 730 803 ATV6B0C40T4
HD – 500 484 402 50 590 885
ND – 650 626 520 50 830 913 ATV6B0C45T4
ATV6B0C71T4 HD – 550 533 443 50 660 990
ND – 700 674 561 50 900 990 ATV6B0C50T4
HD – 600 578 480 50 730 1095
ND – 800 771 641 50 1020 1122 ATV6B0C56T4
HD – 650 626 520 50 830 1245
ND – 900 862 717 50 1140 1254 ATV6B0C63T4
HD – 700 674 561 50 900 1350
ND – 1000 958 797 50 1260 1386 ATV6B0C71T4
HD – 800 771 641 50 1020 1530
ND – 1100 1049 872 50 1420 1562 ATV6B0C80T4
HD – 900 862 717 50 1140 1710
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

51
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 480 V 50/60 Hz

480 V (-10…10%) IP00 Modular Low Harmonic/Regen drives (1)


ATVPro_CP19028

Motor Line supply Altivar Process


Power indicated on rating Line Apparent Maximum Maximum Max. Reference
plate (2) current power prospec- continuous transient
(3) tive line current (2) current
Isc for 60 s
480 V 480 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
ATV9B0C50T4 THDi ≤ 5% at 100% load in Normal duty
ND – 150 148 123 50 211 253 ATV9B0C11T4
HD – 125 125 104 50 173 260
ND – 200 197 164 50 250 300 ATV9B0C13T4
HD – 150 148 123 50 211 317
ND – 250 245 203 50 302 362 ATV9B0C16T4
HD – 200 197 164 50 250 375
ND – 300 292 243 50 370 444 ATV9B0C20T4
HD – 250 245 203 50 302 453
ATVPro_CP19023

ND – 400 387 322 50 477 572 ATV9B0C25T4


HD – 300 292 243 50 370 555
ND – 500 484 402 50 590 708 ATV9B0C31T4
HD – 400 387 322 50 477 716
ND – 550 533 443 50 660 792 ATV9B0C35T4
HD – 450 436 362 50 520 780
ND – 600 578 480 50 730 876 ATV9B0C40T4
HD – 500 484 402 50 590 885
ND – 650 626 520 50 830 996 ATV9B0C45T4
ATV9B0C80T4 HD – 550 533 443 50 660 990
ND – 700 674 561 50 900 1080 ATV9B0C50T4
HD – 600 578 480 50 730 1095
ND – 800 771 641 50 1020 1224 ATV9B0C56T4
HD – 650 626 520 50 830 1245
ND – 900 862 717 50 1140 1368 ATV9B0C63T4
HD – 700 674 561 50 900 1350
ND – 1000 958 797 50 1260 1512 ATV9B0C71T4
HD – 800 771 641 50 1020 1530
ND – 1100 1049 872 50 1420 1704 ATV9B0C80T4
HD – 900 862 717 50 1140 1710
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

52
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 500 V 50/60 Hz

500 V (-10...15%) IP00 Modular Low Harmonic drives (1)


ATVPro_62317_CPMGU180016

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
500 V 500 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 5% at 100% load in Normal duty
ND 75 – 98 85 50 125 138 ATV6B0C11N6
ATV6B0C11N6
HD 55 – 72 62 50 105 158
ND 90 – 117 101 50 145 160 ATV6B0C13N6
HD 75 – 98 85 50 125 188
ND 110 – 141 122 50 175 193 ATV6B0C16N6
HD 90 – 117 101 50 145 218
ND 132 – 169 146 50 215 237 ATV6B0C20N6
HD 110 – 141 122 50 175 263
ATVPro_CP19025

ND 160 – 204 176 50 275 303 ATV6B0C25N6


HD 132 – 169 146 50 215 323
ND 220 – 278 241 50 340 374 ATV6B0C31N6
HD 160 – 204 176 50 275 413
ND 280 – 352 305 50 425 468 ATV6B0C40N6
HD 220 – 278 241 50 340 510
ND 355 – 446 386 50 520 572 ATV6B0C50N6
HD 280 – 352 305 50 425 638
ND 450 – 562 487 50 650 715 ATV6B0C63N6
HD 355 – 446 386 50 520 780
ND 560 – 701 607 50 830 913 ATV6B0C80N6
ATV6B0C25N6
HD 450 – 564 488 50 650 975
ND 710 – 884 766 50 1030 1133 ATV6B0M10N6
HD 560 – 701 607 50 830 1245
ND 800 – 991 859 50 1230 1353 ATV6B0M12N6
HD 710 – 884 766 50 1030 1545
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

53
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 500 V 50/60 Hz

500 V (-10...15%) IP00 Modular Low Harmonic/Regen drives (1)


ATVPro_62317_CPMGU180016

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current (3) power prospective continuous transient
line Isc current (2) current for
60 s
500 V 500 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 5% at 100% load in Normal duty
ND 75 – 98 85 50 125 150 ATV9B0C11N6
ATV9B0C11N6
HD 55 – 72 62 50 105 158
ND 90 – 117 101 50 145 174 ATV9B0C13N6
HD 75 – 98 85 50 125 188
ND 110 – 141 122 50 175 210 ATV9B0C16N6
HD 90 – 117 101 50 145 218
ND 132 – 169 146 50 215 258 ATV9B0C20N6
HD 110 – 141 122 50 175 263
ATVPro_CP19025

ND 160 – 204 176 50 275 330 ATV9B0C25N6


HD 132 – 169 146 50 215 323
ND 220 – 278 241 50 340 408 ATV9B0C31N6
HD 160 – 204 176 50 275 413
ND 280 – 352 305 50 425 510 ATV9B0C40N6
HD 220 – 278 241 50 340 510
ND 355 – 446 386 50 520 624 ATV9B0C50N6
HD 280 – 352 305 50 425 638
ND 450 – 562 487 50 650 780 ATV9B0C63N6
HD 355 – 446 386 50 520 780
ND 560 – 701 607 50 830 996 ATV9B0C80N6
ATV9B0C25N6
HD 450 – 564 488 50 650 975
ND 710 – 884 766 50 1030 1236 ATV9B0M10N6
HD 560 – 701 607 50 830 1245
ND 800 – 991 859 50 1230 1476 ATV9B0M12N6
HD 710 – 884 766 50 1030 1545
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves in
the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

54
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 600 V 50/60 Hz

600 V (-10...10%) IP00 Modular Low Harmonic drives (1)


ATVPro_CP19026

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current power prospective continuous transient
(3) line Isc current (2) current for
(4) 60 s
600 V 600 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
THDi ≤ 5% at 100% load in Normal duty
ND – 125 102 106 50 125 138 ATV6B0C11T6
ATV6B0C50T6
HD – 100 82 86 50 105 158
ND – 150 121 126 50 145 160 ATV6B0C13T6
HD – 125 102 106 50 125 188
ND – 175 142 147 50 175 193 ATV6B0C16T6
HD – 150 121 126 50 145 218
ND – 200 161 167 50 215 237 ATV6B0C20T6
HD – 175 142 147 50 175 263
ATVPro_CP19027

ND – 250 199 207 50 275 303 ATV6B0C25T6


HD – 200 160 166 50 215 323
ND – 350 277 288 50 340 374 ATV6B0C31T6
HD – 250 199 207 50 275 413
ND – 450 355 369 50 425 468 ATV6B0C40T6
HD – 350 277 288 50 340 510
ND – 550 434 451 50 520 572 ATV6B0C50T6
HD – 450 355 369 50 425 638
ND – 650 511 531 50 650 715 ATV6B0C63T6
HD – 550 434 451 50 520 780
ND – 800 628 652 50 830 913 ATV6B0C80T6
ATV6B0C80T6
HD – 650 513 533 50 650 975
ND – 1000 785 815 50 1030 1133 ATV6B0M10T6
HD – 800 628 652 50 830 1245
ND – 1200 937 973 50 1230 1353 ATV6B0M12T6
HD – 1000 785 815 50 1030 1545
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) T hese values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual PHA2452602).
(3) T ypical value for the indicated motor power and for the maximum prospective line Isc.
(4) For 600V UL certified drives, a higher SCCR is possible under some conditions. Please refer to the Integration Manual
PHA2452602 for more details.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

55
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 600 V 50/60 Hz

600 V (-10...10%) IP00 Modular Low Harmonic/Regen drives (1)


ATVPro_CP19026

Motor Line supply Altivar Process


Power indicated on rating plate (2) Line Apparent Maximum Maximum Max. Reference
current power prospective continuous transient
(3) line Isc current (2) current for
(4) 60 s
600 V 600 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
THDi ≤ 5% at 100% load in Normal duty
ND – 125 102 106 50 125 150 ATV9B0C11T6
ATV9B0C50T6
HD – 100 82 86 50 105 158
ND – 150 121 126 50 145 174 ATV9B0C13T6
HD – 125 102 106 50 125 188
ND – 175 142 147 50 175 210 ATV9B0C16T6
HD – 150 121 126 50 145 218
ND – 200 161 167 50 215 258 ATV9B0C20T6
HD – 175 142 147 50 175 263
ATVPro_CP19027

ND – 250 199 207 50 275 330 ATV9B0C25T6


HD – 200 160 166 50 215 323
ND – 350 277 288 50 340 408 ATV9B0C31T6
HD – 250 199 207 50 275 413
ND – 450 355 369 50 425 510 ATV9B0C40T6
HD – 350 277 288 50 340 510
ND – 550 434 451 50 520 624 ATV9B0C50T6
HD – 450 355 369 50 425 638
ND – 650 511 531 50 650 780 ATV9B0C63T6
HD – 550 434 451 50 520 780
ND – 800 628 652 50 830 996 ATV9B0C80T6
ATV9B0C80T6 HD – 650 513 533 50 650 975
ND – 1000 785 815 50 1030 1236 ATV9B0M10T6
HD – 800 628 652 50 830 1245
ND – 1200 937 973 50 1230 1476 ATV9B0M12T6
HD – 1000 785 815 50 1030 1545
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) T hese values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual PHA2452602).
(3) T ypical value for the indicated motor power and for the maximum prospective line Isc.
(4) For 600V UL certified drives, a higher SCCR is possible under some conditions. Please refer to the Integration Manual
PHA2452602 for more details.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

56
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 690 V 50/60 Hz

690 V (-10...10%) IP00 Modular Low Harmonic drives (1)


ATVPro_CP19028

Motor Line supply Altivar Process


Power indicated on rating Line Apparent Maximum Maximum Max. Reference
plate (2) current power prospective continuous transient
(3) line Isc current (2) current
for 60 s
690 V 690 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for fluid management
ATV6B0M10Q6 THDi ≤ 5% at 100% load in Normal duty
ND 110 – 102 122 50 125 138 ATV6B0C11Q6
HD 90 – 85 101 50 105 158
ND 132 – 122 146 50 145 160 ATV6B0C13Q6
HD 110 – 102 122 50 125 188
ND 160 – 148 177 50 175 193 ATV6B0C16Q6
HD 132 – 122 146 50 145 218
ND 200 – 183 219 50 215 237 ATV6B0C20Q6
HD 160 – 148 177 50 175 263
ATVPro_CP19023

ND 250 – 228 273 50 275 303 ATV6B0C25Q6


HD 200 – 183 219 50 215 323
ND 315 – 287 343 50 340 374 ATV6B0C31Q6
HD 250 – 228 273 50 275 413
ND 400 – 363 434 50 425 468 ATV6B0C40Q6
HD 315 – 287 343 50 340 510
ND 500 – 453 541 50 520 572 ATV6B0C50Q6
HD 400 – 362 433 50 425 638
ND 630 – 568 678 50 650 715 ATV6B0C63Q6
ATV6B0M12Q6 HD 500 – 453 541 50 520 780
ND 800 – 718 859 50 830 913 ATV6B0C80Q6
HD 630 – 569 680 50 650 975
ND 1000 – 898 1073 50 1030 1133 ATV6B0M10Q6
HD 800 – 718 859 50 830 1245
ND 1200 – 1078 1288 50 1230 1353 ATV6B0M12Q6
HD 1000 – 898 1073 50 1030 1545
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

57
References (continued) Variable speed drives
Altivar Process Modular
Drives for cabinet integration
Three-phase supply voltage: 690 V 50/60 Hz

690 V (-10...10%) IP00 Modular Low Harmonic/Regen drives (1)


ATVPro_CP19028

Motor Line supply Altivar Process


Power indicated on rating Line Apparent Maximum Maximum Max. Reference
plate (2) current power prospective continuous transient
(3) line Isc current (2) current
for 60 s
690 V 690 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular for demanding applications
ATV9B0M10Q6 THDi ≤ 5% at 100% load in Normal duty
ND 110 – 102 122 50 125 150 ATV9B0C11Q6
HD 90 – 85 101 50 105 158
ND 132 – 122 146 50 145 174 ATV9B0C13Q6
HD 110 – 102 122 50 125 188
ND 160 – 148 177 50 175 210 ATV9B0C16Q6
HD 132 – 122 146 50 145 218
ND 200 – 183 219 50 215 258 ATV9B0C20Q6
HD 160 – 148 177 50 175 263
ATVPro_CP19023

ND 250 – 228 273 50 275 330 ATV9B0C25Q6


HD 200 – 183 219 50 215 323
ND 315 – 287 343 50 340 408 ATV9B0C31Q6
HD 250 – 228 273 50 275 413
ND 400 – 363 434 50 425 510 ATV9B0C40Q6
HD 315 – 287 343 50 340 510
ND 500 – 453 541 50 520 624 ATV9B0C50Q6
HD 400 – 362 433 50 425 638
ND 630 – 568 678 50 650 780 ATV9B0C63Q6
ATV9B0M12Q6 HD 500 – 453 541 50 520 780
ND 800 – 718 859 50 830 996 ATV9B0C80Q6
HD 630 – 569 680 50 650 975
ND 1000 – 898 1073 50 1030 1236 ATV9B0M10Q6
HD 800 – 718 859 50 830 1245
ND 1200 – 1078 1288 50 1230 1476 ATV9B0M12Q6
HD 1000 – 898 1073 50 1030 1545
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual PHA2452602).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

58
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 400 V 50/60 Hz

400 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20132

Motor Line supply Altivar Process


Power indicated on rating plate Line Apparent Maximum Maximum Max. Reference
(2) current power prospective continuous transient
(3) line Isc current current for
(2) 60 s
400 V 400 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ATV6L0C13Q4 ND 132 - 244 169 50 250 275 ATV6L0C13Q4
HD 110 - 210 145 50 211 317
ND 160 - 287 199 50 302 332 ATV6L0C16Q4
HD 132 - 244 169 50 250 375
ND 200 - 350 242 50 370 407 ATV6L0C20Q4
ATVM_CP20133

HD 160 - 287 199 50 302 453


ND 250 - 429 297 50 477 525 ATV6L0C25Q4
HD 200 - 350 242 50 370 555
ND 315 - 536 371 50 590 649 ATV6L0C31Q4
HD 250 - 429 297 50 477 716
ND 400 - 684 474 50 730 803 ATV6L0C40Q4
HD 315 - 549 380 50 590 885
ND 500 - 847 587 50 900 990 ATV6L0C50Q4
HD 400 - 684 474 50 730 1095
ND 630 - 1056 732 50 1140 1254 ATV6L0C63Q4
ATV6L0C50Q4 HD 500 - 847 587 50 900 1350
ND 800 - 1335 925 50 1420 1562 ATV6L0C80Q4
HD 630 - 1062 736 50 1140 1710
ND 900 - 1502 1041 50 1600 1760 ATV6L0C90Q4
HD 710 - 1188 823 50 1260 1890
ND 1000 - 1669 1156 50 1770 1947 ATV6L0M10Q4
HD 800 - 1339 928 50 1420 2130
ND 1200 - 2005 1389 50 2140 2354 ATV6L0M12Q4
HD 1000 - 1669 1156 50 1770 2655
ND 1500 - 2513 1741 50 2680 2948 ATV6L0M15Q4
HD 1200 - 2005 1389 50 2140 3210
ND 1800 - 3028 2098 50 3200 3520 ATV6L0M18Q4
HD 1400 - 2341 1622 50 2470 3705
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

59
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 400 V 50/60 Hz

400 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20132

Motor Line supply Altivar Process


Power indicated on rating plate Line Apparent Maximum Maximum Max. Reference
(2) current power prospective continuous transient
(3) line Isc current current for
(2) 60 s
ND: Normal duty 400 V 400 V
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤48% at 100% load in Normal duty with 6-pulse supply (4)
ND 132 - 244 169 50 250 300 ATV9L0C13Q4
HD 110 - 210 145 50 211 317
ATV9L0C13Q4
ND 160 - 287 199 50 302 362 ATV9L0C16Q4
HD 132 - 244 169 50 250 375
ND 200 - 350 242 50 370 444 ATV9L0C20Q4
HD 160 - 287 199 50 302 453
ND 250 - 429 297 50 477 572 ATV9L0C25Q4
ATVM_CP20133

HD 200 - 350 242 50 370 555


ND 315 - 536 371 50 590 708 ATV9L0C31Q4
HD 250 - 429 297 50 477 716
ND 400 - 684 474 50 730 876 ATV9L0C40Q4
HD 315 - 549 380 50 590 885
ND 500 - 847 587 50 900 1080 ATV9L0C50Q4
HD 400 - 684 474 50 730 1095
ND 630 - 1056 732 50 1140 1368 ATV9L0C63Q4
HD 500 - 847 587 50 900 1350
ATV9L0C50Q4 ND 800 - 1335 925 50 1420 1704 ATV9L0C80Q4
HD 630 - 1062 736 50 1140 1710
ND 900 - 1502 1041 50 1600 1920 ATV9L0C90Q4
HD 710 - 1188 823 50 1260 1890
ND 1000 - 1669 1156 50 1770 2124 ATV9L0M10Q4
HD 800 - 1339 928 50 1420 2130
ND 1200 - 2005 1389 50 2140 2568 ATV9L0M12Q4
HD 1000 - 1669 1156 50 1770 2655
ND 1500 - 2513 1741 50 2680 3216 ATV9L0M15Q4
HD 1200 - 2005 1389 50 2140 3210
ND 1800 - 3028 2098 50 3200 3840 ATV9L0M18Q4
HD 1400 - 2341 1622 50 2470 3705
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

60
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 440 V 50/60 Hz

440 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20134

Motor Line supply Altivar Process


Power indicated on rating Line Apparent Maximum Maximum Max. Reference
plate (2) current power prospective continuous transient
(3) line Isc current current for
(2) 60 s
440 V 440 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤48% at 100% load in Normal duty with 6-pulse supply (4)
ATV6L0C80R4 ND 132 - 228 174 50 250 275 ATV6L0C13R4
HD 110 - 198 151 50 211 317
ND 160 - 266 203 50 302 332 ATV6L0C16R4
HD 132 - 228 174 50 250 375
ND 200 - 323 246 50 370 407 ATV6L0C20R4
HD 160 - 266 203 50 302 453
ATVM_CP20135

ND 250 - 394 300 50 477 525 ATV6L0C25R4


HD 200 - 323 246 50 370 555
ND 315 - 490 373 50 590 649 ATV6L0C31R4
HD 250 - 394 300 50 477 716
ND 400 - 627 478 50 730 803 ATV6L0C40R4
HD 315 - 506 386 50 590 885
ND 500 - 774 590 50 900 990 ATV6L0C50R4
HD 400 - 627 478 50 730 1095
ND 630 - 963 734 50 1140 1254 ATV6L0C63R4
HD 500 - 774 590 50 900 1350
ATV6L0M10R4
ND 800 - 1217 927 50 1420 1562 ATV6L0C80R4
HD 630 - 969 738 50 1140 1710
ND 900 - 1365 1040 50 1600 1760 ATV6L0C90R4
HD 710 - 1083 825 50 1260 1890
ND 1000 - 1518 1157 50 1770 1947 ATV6L0M10R4
HD 800 - 1220 930 50 1420 2130
ND 1200 - 1820 1387 50 2140 2354 ATV6L0M12R4
HD 1000 - 1518 1157 50 1770 2655
ND 1500 - 2279 1737 50 2680 2948 ATV6L0M15R4
HD 1200 - 1820 1387 50 2140 3210
ND 1800 - 2741 2089 50 3200 3520 ATV6L0M18R4
HD 1400 - 2125 1619 50 2470 3705
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive temperature
rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating
curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

61
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 440 V 50/60 Hz

440 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20134

Motor Line supply Altivar Process


Power indicated on rating Line Apparent Maximum Maximum Max. Reference
plate (2) current power prospective continuous transient
(3) line Isc current current for
ND: Normal duty 440 V 440 V (2) 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤48% at 100% load in Normal duty with 6-pulse supply (4)
ND 132 - 228 174 50 250 300 ATV9L0C13R4
HD 110 - 198 151 50 211 317
ATV9L0C80R4
ND 160 - 266 203 50 302 362 ATV9L0C16R4
HD 132 - 228 174 50 250 375
ND 200 - 323 246 50 370 444 ATV9L0C20R4
HD 160 - 266 203 50 302 453
ND 250 - 394 300 50 477 572 ATV9L0C25R4
ATVM_CP20135

HD 200 - 323 246 50 370 555


ND 315 - 490 373 50 590 708 ATV9L0C31R4
HD 250 - 394 300 50 477 716
ND 400 - 627 478 50 730 876 ATV9L0C40R4
HD 315 - 506 386 50 590 885
ND 500 - 774 590 50 900 1080 ATV9L0C50R4
HD 400 - 627 478 50 730 1095
ND 630 - 963 734 50 1140 1368 ATV9L0C63R4
HD 500 - 774 590 50 900 1350

ATV9L0M10R4 ND 800 - 1217 927 50 1420 1704 ATV9L0C80R4


HD 630 - 969 738 50 1140 1710
ND 900 - 1365 1040 50 1600 1920 ATV9L0C90R4
HD 710 - 1083 825 50 1260 1890
ND 1000 - 1518 1157 50 1770 2124 ATV9L0M10R4
HD 800 - 1220 930 50 1420 2130
ND 1200 - 1820 1387 50 2140 2568 ATV9L0M12R4
HD 1000 - 1518 1157 50 1770 2655
ND 1500 - 2279 1737 50 2680 3216 ATV9L0M15R4
HD 1200 - 1820 1387 50 2140 3210
ND 1800 - 2741 2089 50 3200 3840 ATV9L0M18R4
HD 1400 - 2125 1619 50 2470 3705
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

62
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 480 V 50/60 Hz

480 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20136

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate current power prospective continuous transient
(2) (3) line Isc current current
(2) for 60 s
480 V 480 V
ND: Normal duty
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤48% at 100% load in Normal duty with 6-pulse supply (4)
ND - 200 230 191 50 250 275 ATV6L0C13T4
ATV6L0M15T4
HD - 150 183 152 50 211 317
ND - 250 278 231 50 302 332 ATV6L0C16T4
HD - 200 230 191 50 250 375
ND - 300 327 272 50 370 407 ATV6L0C20T4
HD - 250 278 231 50 302 453
ATVM_CP20137

ND - 400 425 353 50 477 525 ATV6L0C25T4


HD - 300 327 272 50 370 555
ND - 500 527 438 50 590 649 ATV6L0C31T4
HD - 400 425 353 50 477 716
ND - 600 638 530 50 730 803 ATV6L0C40T4
HD - 500 540 449 50 590 885
ND - 700 738 614 50 900 990 ATV6L0C50T4
HD - 600 638 530 50 730 1095
ND - 900 938 780 50 1140 1254 ATV6L0C63T4
HD - 700 738 614 50 900 1350
ATV6L0M18T4 ND - 1100 1148 954 50 1420 1562 ATV6L0C80T4
HD - 900 944 785 50 1140 1710
ND - 1300 1345 1118 50 1600 1760 ATV6L0C90T4
HD - 1000 1045 869 50 1260 1890
ND - 1400 1451 1206 50 1770 1947 ATV6L0M10T4
HD - 1100 1151 957 50 1420 2130
ND - 1700 1761 1464 50 2140 2354 ATV6L0M12T4
HD - 1400 1451 1206 50 1770 2655
ND - 2200 2282 1897 50 2680 2948 ATV6L0M15T4
HD - 1700 1761 1464 50 2140 3210
ND - 2500 2598 2160 50 3200 3520 ATV6L0M18T4
HD - 2000 2073 1723 50 2470 3705
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see
the derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

63
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 480 V 50/60 Hz

480 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20136

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current (2) current
ND: Normal duty 480 V 480 V for 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤48% at 100% load in Normal duty with 6-pulse supply (4)
ND - 200 230 191 50 250 300 ATV9L0C13T4
HD - 150 183 152 50 211 317
ATV9L0M15T4 ND - 250 278 231 50 302 362 ATV9L0C16T4
HD - 200 230 191 50 250 375
ND - 300 327 272 50 370 444 ATV9L0C20T4
HD - 250 278 231 50 302 453
ND - 400 425 353 50 477 572 ATV9L0C25T4
ATVM_CP20137

HD - 300 327 272 50 370 555


ND - 500 527 438 50 590 708 ATV9L0C31T4
HD - 400 425 353 50 477 716
ND - 600 638 530 50 730 876 ATV9L0C40T4
HD - 500 540 449 50 590 885
ND - 700 738 614 50 900 1080 ATV9L0C50T4
HD - 600 638 530 50 730 1095
ND - 900 938 780 50 1140 1368 ATV9L0C63T4
HD - 700 738 614 50 900 1350
ND - 1100 1148 954 50 1420 1704 ATV9L0C80T4
ATV9L0M18T4 HD - 900 944 785 50 1140 1710
ND - 1300 1345 1118 50 1600 1920 ATV9L0C90T4
HD - 1000 1045 869 50 1260 1890
ND - 1400 1451 1206 50 1770 2124 ATV9L0M10T4
HD - 1100 1151 957 50 1420 2130
ND - 1700 1761 1464 50 2140 2568 ATV9L0M12T4
HD - 1400 1451 1206 50 1770 2655
ND - 2200 2282 1897 50 2680 3216 ATV9L0M15T4
HD - 1700 1761 1464 50 2140 3210
ND - 2500 2598 2160 50 3200 3840 ATV9L0M18T4
HD - 2000 2073 1723 50 2470 3705
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see
the derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

64
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 500 V 50/60 Hz

500 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20132

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current (2) current for
ND: Normal duty 500 V 500 V 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ND 132 - 196 170 50 215 237 ATV6L0C20N6
HD 110 - 169 146 50 175 263
ATV6L0C20N6
ND 200 - 281 243 50 308 339 ATV6L0C28N6
HD 160 - 230 199 50 240 360
ND 220 - 307 266 50 340 374 ATV6L0C31N6
HD 180 - 256 222 50 275 413
ND 250 - 344 298 50 425 468 ATV6L0C40N6
ATVM_CP20133

HD 220 - 307 266 50 340 510


ND 315 - 429 372 50 480 528 ATV6L0C45N6
HD 250 - 344 298 50 384 576
ND 400 - 549 475 50 590 649 ATV6L0C56N6
HD 315 - 442 383 50 480 720
ND 500 - 679 588 50 740 814 ATV6L0C71N6
HD 400 - 549 475 50 590 885
ND 630 - 846 733 50 930 1023 ATV6L0C90N6
HD 500 - 679 588 50 740 1110
ATV6L0C71N6 ND 800 - 1070 927 50 1230 1353 ATV6L0M12N6
HD 710 - 957 829 50 1030 1545
ND 1000 - 1335 1156 50 1425 1568 ATV6L0M14N6
HD 800 - 1070 927 50 1130 1695
ND 1200 - 1603 1388 50 1620 1782 ATV6L0M16N6
HD 900 - 1204 1043 50 1330 1995
ND 1300 - 1737 1504 50 1820 2002 ATV6L0M18N6
HD 1000 - 1335 1156 50 1425 2138
ND 1600 - 2141 1854 50 2220 2442 ATV6L0M22N6
HD 1200 - 1602 1387 50 1720 2580
ND 1900 - 2550 2208 50 2620 2882 ATV6L0M26N6
HD 1500 - 2005 1736 50 2120 3180
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

65
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 500 V 50/60 Hz

500 V (-15...10%) IP00 Modular Liquid-cooled drives (1).


ATVM_CP20132

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current (2) current
ND: Normal duty 500 V 500 V for 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ND 132 - 196 170 50 215 258 ATV9L0C20N6
HD 110 - 169 146 50 175 263
ATV9L0C20N6
ND 200 - 281 243 50 308 370 ATV9L0C28N6
HD 160 - 230 199 50 240 360
ND 220 - 307 266 50 340 408 ATV9L0C31N6
HD 180 - 256 222 50 275 413
ATVM_CP20133

ND 250 - 344 298 50 425 510 ATV9L0C40N6


HD 220 - 307 266 50 340 510
ND 315 - 429 372 50 480 576 ATV9L0C45N6
HD 250 - 344 298 50 384 576
ND 400 - 549 475 50 590 708 ATV9L0C56N6
HD 315 - 442 383 50 480 720
ND 500 - 679 588 50 740 888 ATV9L0C71N6
HD 400 - 549 475 50 590 885
ND 630 - 846 733 50 930 1116 ATV9L0C90N6
HD 500 - 679 588 50 740 1110
ATV9L0C71N6
ND 800 - 1070 927 50 1230 1476 ATV9L0M12N6
HD 710 - 957 829 50 1030 1545
ND 1000 - 1335 1156 50 1425 1710 ATV9L0M14N6
HD 800 - 1070 927 50 1130 1695
ND 1200 - 1603 1388 50 1620 1944 ATV9L0M16N6
HD 900 - 1204 1043 50 1330 1995
ND 1300 - 1737 1504 50 1820 2184 ATV9L0M18N6
HD 1000 - 1335 1156 50 1425 2138
ND 1600 - 2141 1854 50 2220 2664 ATV9L0M22N6
HD 1200 - 1602 1387 50 1720 2580
ND 1900 - 2550 2208 50 2620 3144 ATV9L0M26N6
HD 1500 - 2005 1736 50 2120 3180
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

66
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 600 V 50/60 Hz

600 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20134

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current (2) current
ND: Normal duty 600 V 600 V for 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ND - 200 184 191 50 215 237 ATV6L0C20T6
HD - 150 146 152 50 175 263
ATV6L0M12T6
ND - 300 261 271 50 308 339 ATV6L0C28T6
HD - 200 184 191 50 240 360
ND - 350 302 314 50 340 374 ATV6L0C31T6
HD - 250 223 232 50 275 413
ATVM_CP20135

ND - 450 381 396 50 425 468 ATV6L0C40T6


HD - 350 302 314 50 340 510
ND - 500 422 439 50 480 528 ATV6L0C45T6
HD - 400 340 353 50 384 576
ND - 600 512 532 50 590 649 ATV6L0C56T6
HD - 500 434 451 50 480 720
ND - 700 592 615 50 740 814 ATV6L0C71T6
HD - 600 512 532 50 590 885
ND - 900 751 780 50 930 1023 ATV6L0C90T6
HD - 700 592 615 50 740 1110
ATV6L0M18T6
ND - 1200 996 1035 50 1230 1353 ATV6L0M12T6
HD - 1000 838 871 50 1030 1545
ND - 1400 1159 1204 50 1425 1568 ATV6L0M14T6
HD - 1100 919 955 50 1130 1695
ND - 1600 1325 1377 50 1620 1782 ATV6L0M16T6
HD - 1300 1081 1123 50 1330 1995
ND - 1800 1490 1548 50 1820 2002 ATV6L0M18T6
HD - 1400 1162 1208 50 1425 2138
ND - 2200 1823 1895 50 2220 2442 ATV6L0M22T6
HD - 1700 1409 1464 50 1720 2580
ND - 2600 2156 2241 50 2620 2882 ATV6L0M26T6
HD - 2100 1740 1808 50 2120 3180
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

67
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 600 V 50/60 Hz

600 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20134

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current (2) current
ND: Normal duty 600 V 600 V for 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ND - 200 184 191 50 215 258 ATV9L0C20T6
HD - 150 146 152 50 175 263
ATV9L0M12T6
ND - 300 261 271 50 308 370 ATV9L0C28T6
HD - 200 184 191 50 240 360
ND - 350 302 314 50 340 408 ATV9L0C31T6
HD - 250 223 232 50 275 413
ATVM_CP20135

ND - 450 381 396 50 425 510 ATV9L0C40T6


HD - 350 302 314 50 340 510
ND - 500 422 439 50 480 576 ATV9L0C45T6
HD - 400 340 353 50 384 576
ND - 600 512 532 50 590 708 ATV9L0C56T6
HD - 500 434 451 50 480 720
ND - 700 592 615 50 740 888 ATV9L0C71T6
HD - 600 512 532 50 590 885
ND - 900 751 780 50 930 1116 ATV9L0C90T6
HD - 700 592 615 50 740 1110
ATV9L0M18T6
ND - 1200 996 1035 50 1230 1476 ATV9L0M12T6
HD - 1000 838 871 50 1030 1545
ND - 1400 1159 1204 50 1425 1710 ATV9L0M14T6
HD - 1100 919 955 50 1130 1695
ND - 1600 1325 1377 50 1620 1944 ATV9L0M16T6
HD - 1300 1081 1123 50 1330 1995
ND - 1800 1490 1548 50 1820 2184 ATV9L0M18T6
HD - 1400 1162 1208 50 1425 2138
ND - 2200 1823 1895 50 2220 2664 ATV9L0M22T6
HD - 1700 1409 1464 50 1720 2580
ND - 2600 2156 2241 50 2620 3144 ATV9L0M26T6
HD - 2100 1740 1808 50 2120 3180
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see the
derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

68
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 690 V 50/60 Hz

690 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20136

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current current
ND: Normal duty 690 V 690 V (2) for 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ND 200 - 218 261 50 215 237 ATV6L0C20Q6
HD 160 - 184 220 50 175 263
ATV6L0M22Q6
ND 280 - 290 347 50 308 339 ATV6L0C28Q6
HD 220 - 236 282 50 240 360
ND 315 - 322 385 50 340 374 ATV6L0C31Q6
HD 250 - 262 313 50 275 413
ATVM_CP20136

ND 400 - 399 477 50 425 468 ATV6L0C40Q6


HD 315 - 322 385 50 340 510
ND 450 - 446 533 50 480 528 ATV6L0C45Q6
HD 355 - 359 429 50 384 576
ND 560 - 563 673 50 590 649 ATV6L0C56Q6
HD 450 - 462 552 50 480 720
ND 710 - 700 837 50 740 814 ATV6L0C71Q6
HD 560 - 563 673 50 590 885
ND 900 - 875 1046 50 930 1023 ATV6L0C90Q6
HD 710 - 700 837 50 740 1110
ATV6L0M26Q6 ND 1200 - 1260 1506 50 1230 1353 ATV6L0M12Q6
HD 1000 - 976 1166 50 1030 1545
ND 1400 - 1355 1619 50 1425 1568 ATV6L0M14Q6
HD 1100 - 1070 1279 50 1130 1695
ND 1600 - 1547 1849 50 1620 1782 ATV6L0M16Q6
HD 1300 - 1262 1508 50 1330 1995
ND 1800 - 1740 2080 50 1820 2002 ATV6L0M18Q6
HD 1400 - 1357 1622 50 1425 2138
ND 2200 - 2128 2543 50 2220 2442 ATV6L0M22Q6
HD 1700 - 1644 1965 50 1720 2580
ND 2600 - 2517 3008 50 2620 2882 ATV6L0M26Q6
HD 2100 - 2030 2426 50 2120 3180
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see
the derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

69
References (continued) Variable speed drives
Altivar Process Modular
Modular Liquid-cooled drives
Three-phase supply voltage: 690 V 50/60 Hz

690 V (-15...10%) IP00 Modular Liquid-cooled drives (1)


ATVM_CP20136

Motor Line supply Altivar Process


Power indicated on Line Apparent Maximum Maximum Max. Reference
rating plate (2) current power prospective continuous transient
(3) line Isc current current for
ND: Normal duty 690 V 690 V (2) 60 s
HD: Heavy duty
kW HP A kVA kA A A
Altivar Process Modular Liquid-cooled
THDi ≤ 48% at 100% load in Normal duty with 6-pulse supply (4)
ND 200 - 218 261 50 215 258 ATV9L0C20Q6
HD 160 - 184 220 50 175 263
ATV9L0M22Q6
ND 280 - 290 347 50 308 370 ATV9L0C28Q6
HD 220 - 236 282 50 240 360
ND 315 - 322 385 50 340 408 ATV9L0C31Q6
HD 250 - 262 313 50 275 413
ATVM_CP20136

ND 400 - 399 477 50 425 510 ATV9L0C40Q6


HD 315 - 322 385 50 340 510
ND 450 - 446 533 50 480 576 ATV9L0C45Q6
HD 355 - 359 429 50 384 576
ND 560 - 563 673 50 590 708 ATV9L0C56Q6
HD 450 - 462 552 50 480 720
ND 710 - 700 837 50 740 888 ATV9L0C71Q6
HD 560 - 563 673 50 590 885
ND 900 - 875 1046 50 930 1116 ATV9L0C90Q6
HD 710 - 700 837 50 740 1110
ATV9L0M26Q6 ND 1200 - 1260 1506 50 1230 1476 ATV9L0M12Q6
HD 1000 - 976 1166 50 1030 1545
ND 1400 - 1355 1619 50 1425 1710 ATV9L0M14Q6
HD 1100 - 1070 1279 50 1130 1695
ND 1600 - 1547 1849 50 1620 1944 ATV9L0M16Q6
HD 1300 - 1262 1508 50 1330 1995
ND 1800 - 1740 2080 50 1820 2184 ATV9L0M18Q6
HD 1400 - 1357 1622 50 1425 2138
ND 2200 - 2128 2543 50 2220 2664 ATV9L0M22Q6
HD 1700 - 1644 1965 50 1720 2580
ND 2600 - 2517 3008 50 2620 3144 ATV9L0M26Q6
HD 2100 - 2030 2426 50 2120 3180
(1) Integrated motor chokes allowing a shielded motor cable length up to 300 m/984 ft in category C3.
(2) These values are given for a nominal switching frequency of 2.5 kHz for use in continuous operation.
The switching frequency is adjustable from 2 to 4.9 kHz for all ratings.
Above 2.5 kHz, the drive will automatically reduce the switching frequency in the event of an excessive
temperature rise.
For continuous operation above the nominal switching frequency, derate the nominal drive current (see
the derating curves in the Integration Manual).
(3) Typical value for the indicated motor power and for the maximum prospective line Isc.
(4) APM-L architecture is ready for 12-pulse supply, which allows a THDi ≤9%.

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

70
References Variable speed drives
Altivar Process Modular
Braking units 400 V power supply
Standard and Low Harmonic/Regenerative drives

Braking units 400 V power supply


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
400 V power supply - Standard drives
ND 110 – ATV9A0C11Q4 160 – 3x 6.7 198 116.16 75 MODBUOC16Q4APM
HD 90 –
ND 132 – ATV9A0C13Q4
HD 110 –
ND 160 – ATV9A0C16Q4
HD 132 –
MODBUOC16Q4APM
ND 200 – ATV9A0C20Q4 315 – 3x 3.35 375 220 130 MODBUOC31Q4APM
HD 160 –
ND 250 – ATV9A0C25Q4
HD 200 –
ND 315 – ATV9A0C31Q4
HD 250 –
ND 355 – ATV9A0C35Q4 500 – 3x 2.23 600 352 225 MODBUOC50Q4APM
HD 280 –
ND 400 – ATV9A0C40Q4
HD 315 –
ND 450 – ATV9A0C45Q4
HD 355 –
ND 500 – ATV9A0C50Q4
HD 400 –
ND 560 – ATV9A0C56Q4 630 – 6x 3.35 750 440 260 MODBUOC63Q4APM
ND 630 – ATV9A0C63Q4
ND 710 – ATV9A0C71Q4 800 – 6x 2.68 945 554.4 355 MODBUOC80Q4APM
ND 800 – ATV9A0C80Q4 or
3x 2.23
+
3x 3.35

400 V power supply - Low Harmonic/Regenerative drives


ND 110 – ATV9B0C11Q4 160 – 3x 6.7 198 116.16 75 MODBUOC16Q4APM
HD 90 –
ND 132 – ATV9B0C13Q4
HD 110 –
ND 160 – ATV9B0C16Q4
HD 132 –
ND 200 – ATV9B0C20Q4 315 – 3x 3.35 375 220 130 MODBUOC31Q4APM
HD 160 –
ND 250 – ATV9B0C25Q4
HD 200 –
ND 315 – ATV9B0C31Q4
HD 250 –
ND 355 – ATV9B0C35Q4 500 3x 2.23 600 352 225 MODBUOC50Q4APM
HD 280 – –
ND 400 – ATV9B0C40Q4
HD 315 –
ND 450 – ATV9B0C45Q4
HD 355 –
ND 500 – ATV9B0C50Q4
HD 400 –
HD 450 – ATV9B0C56Q4
HD 500 – ATV9B0C63Q4
HD 560 – ATV9B0C71Q4
HD 630 – ATV9B0C80Q4
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

71
References (continued) Variable speed drives
Altivar Process Modular
Braking units 400 V power supply
Liquid-cooled drives

Braking units 400 V power supply (continued)


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
400 V power supply - Liquid-cooled drives
ND 132 - ATV9L0C13Q4 160 – 3x 6.7 198 116.16 75 MODBUOC16Q4APM
HD 110 -
ND 160 - ATV9L0C16Q4
HD 132 -
ND 200 - ATV9L0C20Q4 315 – 3x 3.35 375 220 130 MODBUOC31Q4APM
HD 160 -
MODBUOC16Q4APM
ND 250 - ATV9L0C25Q4
HD 200 -
ND 315 - ATV9L0C31Q4
HD 250 -
ND 400 - ATV9L0C40Q4 500 – 3x 2.23 600 352 225 MODBUOC50Q4APM
HD 315 -
ND 500 - ATV9L0C50Q4
HD 400 -
ND 630 - ATV9L0C63Q4 630 – 6x 3.35 750 440 260 MODBUOC63Q4APM
HD 500 -
ND 800 - ATV9L0C80Q4 800 – 6x 2.68 945 554.4 355 MODBUOC80Q4APM
HD 630 - or
3x 2.23
ND 900 - ATV9L0C90Q4 +
HD 710 - 3x 3.35
ND 1000 - ATV9L0M10Q4
HD 800 -
ND 1200 - ATV9L0M12Q4
HD 1000 -
ND 1500 - ATV9L0M15Q4
HD 1200 -
ND 1800 - ATV9L0M18Q4
HD 1400 -
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

72
References (continued) Variable speed drives
Altivar Process Modular
Braking units 440 V power supply
Standard and Low Harmonic/Regenerative drives

Braking units 440 V power supply


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
440 V power supply - Standard drives
ND 110 – ATV9A0C11R4 160 – 3x 6.7 198 116.16 75 MODBUOC16R4APM
HD 90 –
ND 132 – ATV9A0C13R4
HD 110 –
ND 160 – ATV9A0C16R4
HD 132 –
MODBUOC16R4APM
ND 200 – ATV9A0C20R4 315 – 3x 3.35 375 220 130 MODBUOC31R4APM
HD 160 –
ND 250 – ATV9A0C25R4
HD 200 –
ND 315 – ATV9A0C31R4
HD 250 –
ND 355 – ATV9A0C35R4 500 – 3x 2.23 600 352 225 MODBUOC50R4APM
HD 280 –
ND 400 – ATV9A0C40R4
HD 315 –
ND 450 – ATV9A0C45R4
HD 355 –
ND 500 – ATV9A0C50R4
HD 400 –
ND 560 – ATV9A0C56R4 630 – 6x 3.35 750 440 260 MODBUOC63R4APM
ND 630 – ATV9A0C63R4
ND 710 – ATV9A0C71R4 800 – 6x 2.68 945 554.4 355 MODBUOC80R4APM
ND 800 – ATV9A0C80R4 or
3x 2.23
+
3x 3.35
440 V power supply - Low Harmonic/Regenerative drives
ND 110 – ATV9B0C11R4 160 – 3x 6.7 198 116.16 75 MODBUOC16R4APM
HD 90 –
ND 132 – ATV9B0C13R4
HD 110 –
ND 160 – ATV9B0C16R4
HD 132 –
ND 200 – ATV9B0C20R4 315 – 3x 3.35 375 220 130 MODBUOC31R4APM
HD 160 –
ND 250 – ATV9B0C25R4
HD 200 –
ND 315 – ATV9B0C31R4
HD 250 –
ND 355 – ATV9B0C35R4 500 – 3x 2.23 600 352 225 MODBUOC50R4APM
HD 280 –
ND 400 – ATV9B0C40R4
HD 315 –
ND 450 – ATV9B0C45R4
HD 355 –
ND 500 – ATV9B0C50R4
HD 400 –
HD 450 – ATV9B0C56Q4
HD 500 – ATV9B0C63Q4
HD 560 – ATV9B0C71Q4
HD 630 – ATV9B0C80Q4
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

73
References (continued) Variable speed drives
Altivar Process Modular
Braking units 440 V power supply
Liquid-cooled drives

Braking units 440 V power supply (continued)


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
440 V power supply - Liquid-cooled drives
ND 132 - ATV9L0C13R4 160 – 3x 6.7 198 116.16 75 MODBUOC16R4APM
HD 110 -
ND 160 - ATV9L0C16R4
HD 132 -
ND 200 - ATV9L0C20R4 315 – 3x 3.35 375 220 130 MODBUOC31R4APM
HD 160 -
MODBUOC16R4APM
ND 250 - ATV9L0C25R4
HD 200 -
ND 315 - ATV9L0C31R4
HD 250 -
ND 400 - ATV9L0C40R4 500 – 3x 2.23 600 352 225 MODBUOC50R4APM
HD 315 -
ND 500 - ATV9L0C50R4
HD 400 -
ND 630 - ATV9L0C63R4 630 – 6x 3.35 750 440 260 MODBUOC63R4APM
HD 500 -
ND 800 - ATV9L0C80R4 800 – 6x 2.68 945 554.4 355 MODBUOC80R4APM
HD 630 - or
3x 2.23
ND 900 - ATV9L0C90R4 +
HD 710 - 3x 3.35
ND 1000 - ATV9L0M10R4
HD 800 -
ND 1200 - ATV9L0M12R4
HD 1000 -
ND 1500 - ATV9L0M15R4
HD 1200 -
ND 1800 - ATV9L0M18R4
HD 1400 -
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

74
References Variable speed drives
Altivar Process Modular
Braking units 480 V power supply
Standard and Low Harmonic/Regenerative drives

Braking units 480 V power supply


ATVM_OP19057

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
480 V power supply - Standard drives
ND – 150 ATV9A0C11T4 – 250 3x 6.7 198 116.16 75 MODBUOC16T4APM
HD – 125
ND – 200 ATV9A0C13T4
HD – 150
ND – 250 ATV9A0C16T4
HD – 200
MODBUOC80T4APM
ND – 300 ATV9A0C20T4 – 500 3x 3.35 375 220 130 MODBUOC31T4APM
HD – 250
ND – 400 ATV9A0C25T4
HD – 300
ND – 500 ATV9A0C31T4
HD – 400
ND – 550 ATV9A0C35T4 – 700 3x 2.23 600 352 225 MODBUOC50T4APM
HD – 450
ND – 600 ATV9A0C40T4
HD – 500
ND – 650 ATV9A0C45T4
HD – 550
ND – 700 ATV9A0C50T4
HD – 600
ND – 800 ATV9A0C56T4 – 900 6x 3.35 750 440 260 MODBUOC63T4APM
ND – 900 ATV9A0C63T4
ND – 1000 ATV9A0C71T4 – 1100 6x 2.68 945 554.4 355 MODBUOC80T4APM
ND – 1100 ATV9A0C80T4 or
3x 2.23
+
3x 3.35

480 V power supply - Low Harmonic/Regenerative drives


ND – 150 ATV9B0C11T4 – 250 3x 6.7 198 116.16 75 MODBUOC16T4APM
HD – 125
ND – 200 ATV9B0C13T4
HD – 150
ND – 250 ATV9B0C16T4
HD – 200
ND – 300 ATV9B0C20T4 – 500 3x 3.35 375 220 130 MODBUOC31T4APM
HD – 250
ND – 400 ATV9B0C25T4
HD – 300
ND – 500 ATV9B0C31T4
HD – 400
ND – 550 ATV9B0C35T4 – 700 3x 2.23 600 352 225 MODBUOC50T4APM
HD – 450
ND – 600 ATV9B0C40T4
HD – 500
ND – 650 ATV9B0C45T4
HD – 550
ND – 700 ATV9B0C50T4
HD – 600
HD – 650 ATV9B0C56T4
HD – 700 ATV9B0C63T4
HD – 800 ATV9B0C71T4
HD – 900 ATV9B0C80T4
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

75
References (continued) Variable speed drives
Altivar Process Modular
Braking units 480 V power supply
Liquid-cooled drives

Braking units 480 V power supply (continued)


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
480 V power supply - Liquid-cooled drives
ND - 200 ATV9L0C13T4 – 250 3x 6.7 198 116.16 75 MODBUOC16T4APM
HD - 150
ND - 250 ATV9L0C16T4
HD - 200
ND - 300 ATV9L0C20T4 – 500 3x 3.35 375 220 130 MODBUOC31T4APM
HD - 250
MODBUOC16T4APM
ND - 400 ATV9L0C25T4
HD - 300
ND - 500 ATV9L0C31T4
HD - 400
ND - 600 ATV9L0C40T4 – 700 3x 2.23 600 352 225 MODBUOC50T4APM
HD - 500
ND - 700 ATV9L0C50T4
HD - 600
ND - 900 ATV9L0C63T4 – 900 6x 3.35 750 440 260 MODBUOC63T4APM
HD - 700
ND - 1100 ATV9L0C80T4 – 1100 6x 2.68 945 554.4 355 MODBUOC80T4APM
HD - 900 or
3x 2.23
ND - 1300 ATV9L0C90T4 +
HD - 1000 3x 3.35
ND - 1400 ATV9L0M10T4
HD - 1100
ND - 1700 ATV9L0M12T4
HD - 1400
ND - 2200 ATV9L0M15T4
HD - 1700
ND - 2500 ATV9L0M18T4
HD - 2000
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

Presentation: Configuration and runtime tools: Combinations: Dimensions:


page 10 page 28 page 80 page 20

76
References (continued) Variable speed drives
Altivar Process Modular
Braking units 500 V power supply
Standard and Liquid-cooled drives

Braking units 500 V power supply


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
500 V power supply - Standard drives
ND 75 – ATV9A0C11N6 132 – 3x 11 240 140.8 85 MODBUOC20N6APM
HD 55 –
ND 90 – ATV9A0C13N6
HD 75 –
ND 110 – ATV9A0C16N6
HD 90 –
MODBUOC40N6APM ND 132 – ATV9A0C20N6
HD 110 –
ND 160 – ATV9A0C25N6 280 – 3x 5.5 472.5 277.2 165 MODBUOC40N6APM
HD 132 –
ND 220 – ATV9A0C31N6
HD 160 –
ND 280 – ATV9A0C40N6
HD 220 –
ND 355 – ATV9A0C50N6 450 – 3x 3.67 750 440 285 MODBUOC63N6APM
HD 280 –
ND 450 – ATV9A0C63N6
HD 355 –
ND 560 – ATV9A0C80N6 560 – 6x 5.5 945 554.4 330 MODBUOC80N6APM
HD 450 –
ND 710 – ATV9A0M10N6 710 – 6x 4.4 1200 704 450 MODBUOM10N6APM
HD 560 – or
3x 3.67
+ 3x 5.5
ND 800 – ATV9A0M12N6 800 – 6x 3.67 1500 785 550 MODBUOM12N6APM
HD 710 –

500 V power supply - Liquid-cooled drives


ND 132 - ATV9L0C20N6 132 – 3x 11 240 140.8 85 MODBUOC20N6APM
HD 110 -
ND 200 - ATV9L0C28N6 280 – 3x 5.5 472.5 277.2 165 MODBUOC40N6APM
HD 160 -
ND 220 - ATV9L0C31N6
HD 180 -
ND 250 - ATV9L0C40N6
HD 220 -
ND 315 - ATV9L0C45N6 450 – 3x 3.67 750 440 285 MODBUOC63N6APM
HD 250 -
ND 400 - ATV9L0C56N6
HD 315 -
ND 500 - ATV9L0C71N6 560 – 6x 5.5 945 554.4 330 MODBUOC80N6APM
HD 400 -
ND 630 - ATV9L0C90N6 710 – 6x 4.4 1200 704 450 MODBUOM10N6APM
HD 500 - or
3x 3.67
+ 3x 5.5
ND 800 - ATV9L0M12N6 800 – 6x 3.67 1500 785 550 MODBUOM12N6APM
HD 710 -
ND 1000 - ATV9L0M14N6
HD 800 -
ND 1200 - ATV9L0M16N6
HD 900 -
ND 1300 - ATV9L0M18N6
HD 1000 -
ND 1600 - ATV9L0M22N6
HD 1200 -
ND 1900 - ATV9L0M26N6
HD 1500 -
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

77
References (continued) Variable speed drives
Altivar Process Modular
Braking units 600 V power supply
Standard and Liquid-cooled drives

Braking units 600 V power supply


ATVM_CP19039B

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
600 V power supply - Standard drives
ND – 125 ATV9A0C11T6 – 200 3x 11 240 140.8 85 MODBUOC20T6APM
HD – 100
ND – 150 ATV9A0C13T6
HD – 125
ND – 175 ATV9A0C16T6
HD – 150
MODBUOC40T6APM ND – 200 ATV9A0C20T6
HD – 175
ND – 250 ATV9A0C25T6 – 450 3x 5.5 472.5 277.2 165 MODBUOC40T6APM
HD – 200
ND – 350 ATV9A0C31T6
HD – 250
ND – 450 ATV9A0C40T6
HD – 350
ND – 550 ATV9A0C50T6 – 650 3x 3.67 750 440 285 MODBUOC63T6APM
HD – 450
ND – 650 ATV9A0C63T6
HD – 550
ND – 800 ATV9A0C80T6 – 800 6x 5.5 945 554.4 330 MODBUOC80T6APM
HD – 650
ND – 1000 ATV9A0M10T6 – 1000 6x 4.4 1200 704 450 MODBUOM10T6APM
HD – 800 or
3x 3.67
+ 3x 5.5
ND – 1200 ATV9A0M12T6 – 1200 6x 3.67 1500 785 550 MODBUOM12T6APM
HD – 1000
600 V power supply - Liquid-cooled drives
ND - 200 ATV9L0C20T6 – 200 3x 11 240 140.8 85 MODBUOC20T6APM
HD - 150
ND - 300 ATV9L0C28T6 – 450 3x 5.5 472.5 277.2 165 MODBUOC40T6APM
HD - 200
ND - 350 ATV9L0C31T6
HD - 250
ND - 450 ATV9L0C40T6
HD - 350
ND - 500 ATV9L0C45T6 – 650 3x 3.67 750 440 285 MODBUOC63T6APM
HD - 400
ND - 600 ATV9L0C56T6
HD - 500
ND - 700 ATV9L0C71T6 – 800 6x 5.5 945 554.4 330 MODBUOC80T6APM
HD - 600
ND - 900 ATV9L0C90T6 – 1000 6x 4.4 1200 704 450 MODBUOM10T6APM
HD - 700 or
3x 3.67
+ 3x 5.5
ND - 1200 ATV9L0M12T6 – 1200 6x 3.67 1500 785 550 MODBUOM12T6APM
HD - 1000
ND - 1400 ATV9L0M14T6
HD - 1100
ND - 1600 ATV9L0M16T6
HD - 1300
ND - 1800 ATV9L0M18T6
HD - 1400
ND - 2200 ATV9L0M22T6
HD - 1700
ND - 2600 ATV9L0M26T6
HD - 2100
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

78
References (continued) Variable speed drives
Altivar Process Modular
Braking units 690 V power supply
Standard and Liquid-cooled drives

Braking units 690 V power supply


ATVM_OP19057

Drive Braking unit


Nominal power Reference Power rating Minimum Braking power Reference
ND: Normal duty resistor Cycle (1)
HD: Heavy duty value
1 2 3
kW HP kW HP Ω
690 V power supply - Standard drives
ND 110 – ATV9A0C11Q6 200 – 3x 11 240 140.8 85 MODBUOC20Q6APM
HD 90 –
ND 132 – ATV9A0C13Q6
HD 110 –
ND 160 – ATV9A0C16Q6
HD 132 –
MODBUOM12Q6APM ND 200 – ATV9A0C20Q6
HD 160 –
ND 250 – ATV9A0C25Q6 400 – 3x 5.5 472.5 277.2 165 MODBUOC40Q6APM
HD 200 –
ND 315 – ATV9A0C31Q6
HD 250 –
ND 400 – ATV9A0C40Q6
HD 315 –
ND 500 – ATV9A0C50Q6 630 – 3x 3.67 750 440 285 MODBUOC63Q6APM
HD 400 –
ND 630 – ATV9A0C63Q6
HD 500 –
ND 800 – ATV9A0C80Q6 800 – 6x 5.5 945 554.4 330 MODBUOC80Q6APM
HD 630 –
ND 1000 – ATV9A0M10Q6 1000 – 6x 4.4 1200 704 450 MODBUOM10Q6APM
HD 800 – or
3x 3.67
+
3x 5.5
ND 1200 – ATV9A0M12Q6 1200 – 6x 3.67 1500 785 550 MODBUOM12Q6APM
HD 1000 –
690 V power supply - Liquid-cooled drives
ND 200 - ATV9L0C20Q6 200 – 3x 11 240 140.8 85 MODBUOC20Q6APM
HD 160 -
ND 280 - ATV9L0C28Q6 400 – 3x 5.5 472.5 277.2 165 MODBUOC40Q6APM
HD 220 -
ND 315 - ATV9L0C31Q6
HD 250 -
ND 400 - ATV9L0C40Q6
HD 315 -
ND 450 - ATV9L0C45Q6 630 – 3x 3.67 750 440 285 MODBUOC63Q6APM
HD 355 -
ND 560 - ATV9L0C56Q6
HD 450 -
ND 710 - ATV9L0C71Q6 800 – 6x 5.5 945 554.4 330 MODBUOC80Q6APM
HD 560 -
ND 900 - ATV9L0C90Q6 1000 – 6x 4.4 1200 704 450 MODBUOM10Q6APM
HD 710 - or
3x 3.67
+
3x 5.5
ND 1200 - ATV9L0M12Q6 1200 – 6x 3.67 1500 785 550 MODBUOM12Q6APM
HD 1000 -
ND 1400 - ATV9L0M14Q6
HD 1100 -
ND 1600 - ATV9L0M16Q6
HD 1300 -
ND 1800 - ATV9L0M18Q6
HD 1400 -
ND 2200 - ATV9L0M22Q6
HD 1700 -
ND 2600 - ATV9L0M26Q6
HD 2100 -
(1) Value of the average power that can be dissipated at 50 °C/122 °F. For a 240 s period:
- Cycle 1: 12 s braking at overload (=5%)
- Cycle 2: 120 s braking at overload (=50%)
- Cycle 3: 240 s continuous braking (=100%)

79
Combinations Variable speed drives Combinations (continued) Variable speed drives
Altivar Process Modular Altivar Process Modular
Standard architectures without braking unit Standard architectures without braking unit
400...480 V power supply 500...690 V power supply

Table showing possible combinations to create architectures Table showing possible combinations to create architectures
Motor Drive Control units Power modules Front covers Cabinets for IP Motor Drive Control units Power modules Front covers Cabinets for IP
20/21/23/40/41/43/54 integration 20/21/23/40/41/43/54 integration
ND: Normal duty 400 600 800 1,000 ND: Normal duty 400 600 800 1,000
HD: Heavy duty mm mm mm mm HD: Heavy duty mm mm mm mm
kW HP width width width width kW HP width width width width
Standard drives three-phase supply voltage: 400…480 V 50/60 Hz Standard drives three-phase supply voltage: 500…690 V 50/60 Hz
ND 110…160 ATV6A0C11Q4...C16Q4 1 x APM6A0CTLN401 1 x APM1A0C16N401 – 1 – – – ND 75…132 ATV6A0C11N6...C20N6 1 x APM6A0CTLY6 1 x APM1A0C20Y6 – 1 – – –
HD 90…132 ATV6A0C11R4...C16R4 HD 55…110 ATV9A0C11N6...C20N6 1 x APM9A0CTLY6
ATV9A0C11Q4...C16Q4 1 x APM9A0CTLN401 ND 110…200 ATV6A0C16Q6...C20Q6 1 x APM6A0CTLY6
ATV9A0C11R4...C16R4 HD 90…160 ATV9A0C16Q6...C20Q6 1 x APM9A0CTLY6
ND 150…250 ATV6A0C11T4...C16T4 1 x APM6A0CTLN401 ND 175…200 ATV6A0C16T6...C20T6 1 x APM6A0CTLY6
HD 125…200 HD 150…175 ATV9A0C16T6...C20T6 1 x APM6A0CTLY6
ATV9A0C11T4...C16T4 1 x APM9A0CTLN401
ND 160…280 ATV6A0C25N6...C40N6 1 x APM6A0CTLY6 2 x APM1A0C20Y6 1 x VW3A97A01 – 1 – –
ND 200…315 ATV6A0C20Q4...C31Q4 1 x APM6A0CTLN401 2 x APM1A0C16N401 1 x VW3A97A01 – 1 – –
HD 132…220 ATV9A0C25N6...C40N6 1 x APM9A0CTLY6
HD 160…250 ATV6A0C20R4...C31R4 ND 250…400 ATV6A0C25Q6...C40Q6 1 x APM6A0CTLY6
ATV9A0C20Q4...C31Q4 1 x APM9A0CTLN401 HD 200…315 ATV9A0C25Q6...C40Q6 1 x APM9A0CTLY6
ATV9A0C20R4...C31R4 ND 250…450 ATV6A0C25T6...C40T6 1 x APM6A0CTLY6
ND 300…500 ATV6A0C20T4...C31T4 1 x APM6A0CTLN401 HD 200…350 ATV9A0C25T6...C40T6 1 x APM9A0CTLY6
HD 250…400 ATV9A0C20T4...C31T4 1 x APM9A0CTLN401 ND 355…450 ATV6A0C50N6...C63N6 1 x APM6A0CTLY6 3 x APM1A0C20Y6 2 x VW3A97A01 – – 1 –
ND 355…500 ATV6A0C35Q4...C50Q4 1 x APM6A0CTLN401 3 x APM1A0C16N401 2 x VW3A97A01 – – 1 – HD 280…355 ATV9A0C50N6...C63N6 1 x APM9A0CTLY6
HD 280…400 ATV6A0C35R4...C50R4 ND 500…630 ATV6A0C50Q6...C63Q6 1 x APM6A0CTLY6
ATV9A0C35Q4...C50Q4 1 x APM9A0CTLN401 HD 400…500 ATV9A0C50Q6...C63Q6 1 x APM9A0CTLY6
ND 550…650 ATV6A0C50T6...C63T6 1 x APM6A0CTLY6
ATV9A0C35R4...C50R4
HD 450…550 ATV9A0C50T6...N63T6 1 x APM9A0CTLY6
ND 550…700 ATV6A0C35T4...C50T4 1 x APM6A0CTLN401
ND 560 ATV6A0C80N6 1 x APM6A0CTLY6 4 x APM1A0C20Y6 3 x VW3A97A01 – 2 – –
HD 450…600 ATV9A0C35T4...C50T4 1 x APM9A0CTLN401 HD 450 ATV9A0C80N6 1 x APM9A0CTLY6
ND 560…630 ATV6A0C56Q4...C63Q4 1 x APM6A0CTLN401 4 x APM1A0C16N401 3 x VW3A97A01 – 2 – – ND 800 ATV6A0C80Q6 1 x APM6A0CTLY6
HD 450…500 ATV6A0C56R4...C63R4 HD 630 ATV9A0C80Q6 1 x APM9A0CTLY6
ATV9A0C56Q4...C63Q4 1 x APM9A0CTLN401 ND 800 ATV6A0C80T6 1 x APM6A0CTLY6
ATV9A0C56R4...C63R4 HD 650 ATV9A0C80T6 1 x APM9A0CTLY6
ND 800…900 ATV6A0C56T4...C63T4 1 x APM6A0CTLN401 ND 710 ATV6A0M10N6 1 x APM6A0CTLY6 5 x APM1A0C20Y6 4 x VW3A97A01 – 1 1 –
HD 650…700 ATV9A0C56T4...C63T4 1 x APM9A0CTLN401 HD 560 ATV9A0M10N6 1 x APM9A0CTLY6
ND 710…800 ATV6A0C71Q4...C80Q4 1 x APM6A0CTLN401 5 x APM1A0C16N401 4 x VW3A97A01 – 1 1 – ND 1000 ATV6A0M10Q6 1 x APM6A0CTLY6
HD 560…630 HD 800 ATV9A0M10Q6 1 x APM9A0CTLY6
ATV6A0C71R4...C80R4
ND 1000 ATV6A0M10T6 1 x APM6A0CTLY6
ATV9A0C71Q4...C80Q4 1 x APM9A0CTLN401
HD 800 ATV9A0M10T6 1 x APM9A0CTLY6
ATV9A0C71R4...C80R4 ND 800 ATV6A0M12N6 1 x APM6A0CTLY6 6 x APM1A0C20Y6 5 x VW3A97A01 – – 2 –
ND 1000…1100 ATV6A0C71T4...C80T4 1 x APM6A0CTLN401 HD 710 ATV9A0M12N6 1 x APM9A0CTLY6
HD 800…900 ATV9A0C71T4...C80T4 1 x APM9A0CTLN401 ND 1200 ATV6A0M12Q6 1 x APM6A0CTLY6
Low Harmonic/Regenerative drives three-phase supply voltage: 400…480 V 50/60 Hz HD 1000 ATV9A0M12Q6 1 x APM9A0CTLY6
ND 110…160 ATV6B0C11Q4...C16Q4 1 x APM6B0CTLN4 1 x APM1B0C16N4 – – 1 – – ND 1200 ATV6A0M12T6 1 x APM6A0CTLY6
HD 90…132 ATV6B0C11R4...C16R4 HD 1000 ATV9A0M12T6 1 x APM9A0CTLY6
ATV9B0C11Q4...C16Q4 1 x APM9B0CTLN4 Low Harmonic/Regenerative drives three-phase supply voltage: 500…690 V 50/60 Hz
ATV9B0C11R4...C16R4 ND 75...132 ATV6B0C11N6...C20N6 1 x APM6B0CTLY6 1 x APM1B0C20Y6 – – 1 – –
HD 55…110 ATV9B0C11N6...C20N6 1 x APM9B0CTLY6
ND 150…250 ATV6B0C11T4...C16T4 1 x APM6B0CTLN4
HD 125…200 ND 110…200 ATV6B0C11Q6...C20Q6 1 x APM6B0CTLY6
ATV9B0C11T4...C16T4 1 x APM9B0CTLN4
HD 90…160 ATV9B0C11Q6...C20Q6 1 x APM9B0CTLY6
ND 200…315 ATV6B0C20Q4...C31Q4 1 x APM6B0CTLN4 2 x APM1B0C16N4 1 x VW3A97B01 – – – 1 ND 125…200 ATV6B0C11T6...C20T6 1 x APM6B0CTLY6
HD 160…250 ATV6B0C20R4...C31R4 HD 100…175 ATV9B0C11T6...C20T6 1 x APM9B0CTLY6
ATV9B0C20Q4...C31Q4 1 x APM9B0CTLN4 ND 160…280 ATV6B0C25N6...C40N6 1 x APM6B0CTLY6 2 x APM1B0C20Y6 1 x VW3A97B01 – – – 1
ATV9B0C20R4...C31R4 HD 132…220 ATV9B0C25N6...C40N6 1 x APM9B0CTLY6
ND 300…500 ATV6B0C20T4...C31T4 1 x APM6B0CTLN4 ND 250…400 ATV6B025Q6...C40Q6 1 x APM6B0CTLY6
HD 250…400 ATV9B0C20T4...C31T4 1 x APM9B0CTLN4 HD 200…315 ATV9B025Q6...C40Q6 1 x APM9B0CTLY6
ND 355…500 ATV6B0C35Q4...C50Q4 1 x APM6B0CTLN4 3 x APM1B0C16N4 2 x VW3A97B01 – 1 – 1 ND 250…450 ATV6B0C25T6...C40T6 1 x APM6B0CTLY6
HD 280…400 ATV6B0C35R4...C50R4 HD 200…350 ATV9B0C25T6...C40T6 1 x APM9B0CTLY6
ND 355…450 ATV6B0C50N6...C63N6 1 x APM6B0CTLY6 3 x APM1B0C20Y6 2 x VW3A97B01 – 1 – 1
ATV9B0C35Q4...C50Q4 1 x APM9B0CTLN4
HD 280…355 ATV9B0C50N6...C63N6 1 x APM9B0CTLY6
ATV9B0C35R4...C50R4
ND 500…630 ATV6B0C50Q6...C63Q6 1 x APM6B0CTLY6
ND 550…700 ATV6B0C35T4...C50T4 1 x APM6B0CTLN4 HD 400…500 ATV9B0C50Q6...C63Q6 1 x APM9B0CTLY6
HD 450…600 ATV9B0C35T4...C50T4 1 x APM9B0CTLN4 ND 550…650 ATV6B0C50T6...C63T6 1 x APM6B0CTLY6
ND 560…630 ATV6B0C56Q4...C63Q4 1 x APM6B0CTLN4 4 x APM1B0C16N4 3 x VW3A97B01 – – – 2 HD 450…550 ATV9B0C50T6...C63T6 1 x APM9B0CTLY6
HD 450…500 ATV6B0C56R4...C63R4 ND 560 ATV6B0C80N6 1 x APM6B0CTLY6 4 x APM1B0C20Y6 3 x VW3A97B01 – – – 2
ATV9B0C56Q4...C63Q4 1 x APM9B0CTLN4 HD 450 ATV9B0C80N6 1 x APM9B0CTLY6
ATV9B0C56R4...C63R4 ND 800 ATV6B0C80Q6 1 x APM6B0CTLY6
ND 800…900 ATV6B0C56T4...C63T4 1 x APM6B0CTLN4 HD 630 ATV9B0C80Q6 1 x APM9B0CTLY6
HD 650…700 ATV9B0C56T4...C63T4 1 x APM9B0CTLN4 ND 800 ATV6B0C80T6 1 x APM6B0CTLY6
HD 650 ATV9B0C80T6 1 x APM9B0CTLY6
ND 710…800 ATV6B0C71Q4...C80Q4 1 x APM6B0CTLN4 5 x APM1B0C16N4 4 x VW3A97B01 – 1 – 2
ND 710 ATV6A0M10N6 1 x APM6B0CTLY6 5 x APM1B0C20Y6 4 x VW3A97B01 – 1 – 2
HD 560…630 ATV6B0C71R4...C80R4 HD 560 ATV9A0M10N6 1 x APM9B0CTLY6
ATV9B0C71Q4...C80Q4 1 x APM9B0CTLN4 ND 1000 ATV6A0M10Q6 1 x APM6B0CTLY6
ATV9B0C71R4...C80R4 HD 800 ATV9A0M10Q6 1 x APM9B0CTLY6
ND 1000…1100 ATV6B0C71T4...C80T4 1 x APM6B0CTLN4 ND 1000 ATV6A0M10T6 1 x APM6B0CTLY6
HD 800…900 ATV9B0C71T4...C80T4 1 x APM9B0CTLN4 HD 800 ATV9A0M10T6 1 x APM9B0CTLY6
ND 800 ATV6B0M12N6 1 x APM6B0CTLY6 6 x APM1B0C20Y6 5 x VW3A97B01 – – – 3
Pages 35 22 20 23 (1) (2) HD 710 ATV9B0M12N6 1 x APM9B0CTLY6
(1) These cabinet recommendations are for standard integration. For flexible solutions, please contact your Schneider Electric supplier. ND 1200 ATV6B0M12Q6 1 x APM6B0CTLY6
(2) Cabinets must have a minimum depth of 600 mm/23.6 in., and a minimum height of: HD 1000 ATV9B0M12Q6 1 x APM9B0CTLY6
b 2,150 mm/84.6 in. (including the roof-top extension) for IP20/21/23/40/41/43 standard cabinet integration ND 1200 ATV6B0M12T6 1 x APM6B0CTLY6
b 2,350 mm/92.5 in. (including the plinth and roof-top extension) for IP54 standard cabinet integration HD 1000 ATV9B0M12T6 1 x APM9B0CTLY6
Pages 41 22 20 23 (1) (2)

80 80
81
Combinations (continued) Variable speed drives Combinations (continued) Variable speed drives
Altivar Process Modular Altivar Process Modular
Standard architectures with braking unit Standard architectures with braking unit
400...480 V power supply 500...690 V power supply

Table showing possible combinations to create architectures Table showing possible combinations to create architectures
Motor Braking units Control units for Braking unit Front covers Cabinets (drive + braking unit) Motor Braking units Control units for Braking unit Front covers Cabinets (drive + braking unit)
braking units power modules for braking for IP 20/21/23/40/41/43/54 braking units power modules for braking for IP 20/21/23/40/41/43/54
units integration units integration
ND: Normal duty 400 600 800 1,000 ND: Normal duty 400 600 800 1,000
HD: Heavy duty mm mm mm mm HD: Heavy duty mm mm mm mm
kW HP width width width width kW HP width width width width
Standard drives three-phase supply voltage: 400…480 V 50/60 Hz Standard drives three-phase supply voltage: 500…690 V 50/60 Hz
ND 110…160 1 x MODBUOC16Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – – 1 – – ND 75…132 1 x MODBUOC20N6APM 1 x APMBC0CTLY6 1 x APMBC0C50Y6 – – 1 – –
HD 90…132 1 x MODBUOC16R4APM HD 55…110
ND 110…200 1 x MODBUOC20Q6APM
ND 150…250 1 x MODBUOC16T4APM
HD 90…160
HD 125…200
ND 175…200 1 x MODBUOC20T6APM
ND 200…315 1 x MODBUOC31Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – – – 1 –
HD 150…175
HD 160…250 1 x MODBUOC31R4APM ND 160…280 1 x MODBUOC40N6APM 1 x APMBC0CTLY6 1 x APMBC0C50Y6 – – – 1 –
ND 300…500 1 x MODBUOC31T4APM HD 132…220
HD 250…400 ND 250…400 1 x MODBUOC40Q6APM
ND 355…500 1 x MODBUOC50Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 – 1 – HD 200…315
HD 280…400 1 x MODBUOC50R4APM ND 250…450 1 x MODBUOC40T6APM
HD 200…350
ND 550…700 1 x MODBUOC50T4APM
HD 450…600 ND 355…450 1 x MODBUOC63N6APM 1 x APMBC0CTLY6 1 x APMBC0C50Y6 – 1 – 1 –
HD 280…355
ND 560…630 2 x MODBUOC63Q4APM 1 x APMBC0CTLN4 2 x APMBC0C50N4 1 x VW3A97A01 – – 2 –
HD 450…500 ND 500…630 1 x MODBUOC63Q6APM
2 x MODBUOC63R4APM HD 400…500
ND 800…900 2 x MODBUOC63T4APM ND 550…650 1 x MODBUOC63T6APM
HD 650…700 HD 450…550
ND 710…800 2 x MODBUOC80Q4APM 1 x APMBC0CTLN4 2 x APMBC0C50N4 1 x VW3A97A01 – 2 1 – ND 560 2 x MODBUOC80N6APM 1 x APMBC0CTLY6 2 x APMBC0C50Y6 1 x VW3A97A01 – – 2 –
HD 560…630 2 x MODBUOC80R4APM HD 450
ND 1000…1100 2 x MODBUOC80T4APM ND 800 2 x MODBUOC80Q6APM
HD 800…900 HD 630
Low Harmonic/Regenerative drives three-phase supply voltage: 400…480 V 50/60 Hz ND 800 2 x MODBUOC80T6APM
HD 650
ND 110…160 1 x MODBUOC16Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 1 – –
HD 90…132 ND 710 2 x MODBUOM10N6APM 1 x APMBC0CTLY6 2 x APMBC0C50Y6 1 x VW3A97A01 – 2 1 –
1 x MODBUOC16R4APM HD 560
ND 150…250 1 x MODBUOC16T4APM ND 1000 2 x MODBUOM10Q6APM
HD 125…200 HD 800
ND 200…315 1 x MODBUOC31Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 – – 1 ND 1000 2 x MODBUOM10T6APM
HD 160…250 1 x MODBUOC31R4APM HD 800
ND 300…500 1 x MODBUOC31T4APM ND 800 2 x MODBUOM12N6APM 1 x APMBC0CTLY6 2 x APMBC0C50Y6 1 x VW3A97A01 – 1 2 –
HD 250…400 HD 710
ND 355…500 1 x MODBUOC50Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 1 – 1 ND 1200 2 x MODBUOM12Q6APM
HD 280…400 HD 1000
1 x MODBUOC50R4APM
ND 1200 2 x MODBUOM12T6APM
ND 550…700 1 x MODBUOC50T4APM HD 1000
HD 450…600
ND 560…630 1 x MODBUOC50Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 – – 2 Pages 77 27 27 23 (1) (2)
HD 450…500 1 x MODBUOC50R4APM
ND 800…900 1 x MODBUOC50T4APM
HD 650…700
ND 710…800 1 x MODBUOC50Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 1 – 2
HD 560…630 1 x MODBUOC50R4APM
ND 1000…1100 1 x MODBUOC50T4APM
HD 800…900

Pages 71 27 27 23 (1) (2)


(1) These cabinet recommendations are for standard integration. For flexible solutions, please contact your Schneider Electric supplier.
(2) Cabinets must have a minimum depth of 600 mm/23.6 in., and a minimum height of:
b 2,150 mm/84.6 in. (including the roof-top extension) for IP20/21/23/40/41/43 standard cabinet integration
b 2,350 mm/92.5 in. (including the plinth and roof-top extension) for IP54 standard cabinet integration

81
82 81
83
Combinations (continued) Variable speed drives Combinations (continued) Variable speed drives
Altivar Process Modular Altivar Process Modular
Reduced height architectures without braking unit Reduced height architectures without braking unit
400...480 power supply 500...690 power supply

Table showing possible combinations to create architectures Table showing possible combinations to create architectures
Motor Drive Control units Power modules Mains module Front Cabinets for Motor Drive Control units Power modules Mains module Front Cabinets for
covers IP 20/21/23/ covers IP 20/21/23/
40/41/43/54 40/41/43/54
integration integration
ND: Normal duty 600 mm 800 mm ND: Normal duty 600 mm 800 mm
HD: Heavy duty width width HD: Heavy duty width width
kW HP kW HP
Standard drives three-phase supply voltage: 400…480 V 50/60 Hz - Reduced Height version Standard drives three-phase supply voltage: 500…690 V 50/60 Hz - Reduced Height version
ND 110…160 ATV6A0C11Q4...C16Q4 1 x APM6A0CTLN401 1 x 1x – – 1 ND 75…132 ATV6A0C11N6...C20N6 1 x APM6A0CTLY6 1x 1x – – 1
HD 90…132 ATV6A0C11R4...C16R4 APM1A0C16N4RH APMCA01LCN4RH HD 55…110 ATV9A0C11N6...C20N6 1 x APM9A0CTLY6 APM1A0C20Y6RH APMCA01LCY6RH
ATV9A0C11Q4...C16Q4 1 x APM9A0CTLN401 ND 110…200 ATV6A0C16Q6...C20Q6 1 x APM6A0CTLY6
ATV9A0C11R4...C16R4 HD 90…160 ATV9A0C16Q6...C20Q6 1 x APM9A0CTLY6
ND 150…250 ATV6A0C11T4...C16T4 1 x APM6A0CTLN401 ND 175…200 ATV6A0C16T6...C20T6 1 x APM6A0CTLY6
HD 125…200 ATV9A0C11T4...C16T4 1 x APM9A0CTLN401 HD 150…175 ATV9A0C16T6...C20T6 1 x APM9A0CTLY6
ND 200…315 ATV6A0C20Q4...C31Q4 1 x APM6A0CTLN401 2 x 1x 1x 2 – ND 160…280 ATV6A0C25N6...C40N6 1 x APM6A0CTLY6 2x 1x 1x 2 –
HD 160…250 ATV6A0C20R4...C31R4 APM1A0C16N4RH APMCA02LCN4RH VW3A97A01 HD 132…220 ATV9A0C25N6...C40N6 1 x APM9A0CTLY6 APM1A0C16Y6RH APMCA02LCY6RH VW3A97A01
ATV9A0C20Q4...C31Q4 1 x APM9A0CTLN401 ND 250…400 ATV6A0C25Q6...C40Q6 1 x APM6A0CTLY6
ATV9A0C20R4...C31R4 HD 200…315 ATV9A0C25Q6...C40Q6 1 x APM9A0CTLY6
ND 300…500 ATV6A0C20T4...C31T4 1 x APM6A0CTLN401 ND 250…450 ATV6A0C25T6...C40T6 1 x APM6A0CTLY6
HD 250…400 ATV9A0C20T4...C31T4 1 x APM9A0CTLN401 HD 200…350 ATV9A0C25T6...C40T6 1 x APM9A0CTLY6
ND 355…500 ATV6A0C35Q4...C50Q4 1 x APM6A0CTLN401 3 x 1x 2x 1 1 ND 355…450 ATV6A0C50N6...C63N6 1 x APM6A0CTLY6 3x 1x 2x 1 1
HD 280…400 ATV6A0C35R4...C50R4 APM1A0C16N4RH APMCA03LCN4RH VW3A97A01 HD 280…355 ATV9A0C50N6...C63N6 1 x APM9A0CTLY6 APM1A0C16Y6RH APMCA03LCY6RH VW3A97A01
ATV9A0C35Q4...C50Q4 1 x APM9A0CTLN401 ND 500…630 ATV6A0C50Q6...C63Q6 1 x APM6A0CTLY6
ATV9A0C35R4...C50R4 HD 400…500 ATV9A0C50Q6...C63Q6 1 x APM9A0CTLY6
ND 550…700 ATV6A0C35T4...C50T4 1 x APM6A0CTLN401 ND 550…650 ATV6A0C50T6...C63T6 1 x APM6A0CTLY6
HD 450…600 ATV9A0C35T4...C50T4 1 x APM9A0CTLN401 HD 450…550 ATV9A0C50T6...N63T6 1 x APM9A0CTLY6
ND 560…630 ATV6A0C56Q4...C63Q4 1 x APM6A0CTLN401 4 x 2x 3x 4 – ND 560 ATV6A0C80N6 1 x APM6A0CTLY6 4x 2x 3x 4 –
HD 450…500 ATV6A0C56R4...C63R4 APM1A0C16N4RH APMCA02LCN4RH VW3A97A01 HD 450 ATV9A0C80N6 1 x APM9A0CTLY6 APM1A0C16Y6RH APMCA02LCY6RH VW3A97A01
ATV9A0C56Q4...C63Q4 1 x APM9A0CTLN401 ND 800 ATV6A0C80Q6 1 x APM6A0CTLY6
ATV9A0C56R4...C63R4 HD 630 ATV9A0C80Q6 1 x APM9A0CTLY6
ND 800…900 ATV6A0C56T4...C63T4 1 x APM6A0CTLN401 ND 800 ATV6A0C80T6 1 x APM6A0CTLY6
HD 650…700 ATV9A0C56T4...C63T4 1 x APM9A0CTLN401 HD 650 ATV9A0C80T6 1 x APM9A0CTLY6
ND 710…800 ATV6A0C71Q4...C80Q4 1 x APM6A0CTLN401 5 x 1x 4x 3 1 ND 710 ATV6A0M10N6 1 x APM6A0CTLY6 5x 1x 4x 3 1
HD 560…630 ATV6A0C71R4...C80R4 APM1A0C16N4RH APMCA02LCN4RH VW3A97A01 HD 560 APM1A0C16Y6RH APMCA02LCY6RH VW3A97A01
ATV9A0M10N6 1 x APM9A0CTLY6
+ +
ATV9A0C71Q4...C80Q4 1 x APM9A0CTLN401 ND 1000 ATV6A0M10Q6 1 x APM6A0CTLY6
1x 1x
ATV9A0C71R4...C80R4 APMCA03LCN4RH HD 800 ATV9A0M10Q6 1 x APM9A0CTLY6 APMCA03LCY6RH
ND 1000…1100 ATV6A0C71T4...C80T4 1 x APM6A0CTLN401 ND 1000 ATV6A0M10T6 1 x APM6A0CTLY6
HD 800…900 ATV9A0C71T4...C80T4 1 x APM9A0CTLN401 HD 800 ATV9A0M10T6 1 x APM9A0CTLY6
ND 800 ATV6A0M12N6 1 x APM6A0CTLY6 6x 2x 5x 2 2
Pages 35 22 20 21 23 (1) (2) HD 710 APM1A0C16Y6RH APMCA03LCY6RH VW3A97A01
ATV9A0M12N6 1 x APM9A0CTLY6
ND 1200 ATV6A0M12Q6 1 x APM6A0CTLY6
HD 1000 ATV9A0M12Q6 1 x APM9A0CTLY6
ND 1200 ATV6A0M12T6 1 x APM6A0CTLY6
HD 1000 ATV9A0M12T6 1 x APM9A0CTLY6

Pages 41 22 20 21 23 (1) (2)

(1) These cabinet recommendations are for standard integration. For flexible solutions, please contact your Schneider Electric supplier.
(2) Cabinets must have a minimum depth of 600 mm/23.6 in., and a minimum height of:
b 2,150 mm/84.6 in. (including the roof-top extension) for IP20/21/23/40/41/43 standard cabinet integration
b 2,350 mm/92.5 in. (including the plinth and roof-top extension) for IP54 standard cabinet integration

82
84 82
85
Combinations (continued) Variable speed drives Combinations (continued) Variable speed drives
Altivar Process Modular Altivar Process Modular
Reduced height architectures with braking unit Reduced height architectures with braking unit
400...480 V power supply 500...690 V power supply

Table showing possible combinations to create architectures Table showing possible combinations to create architectures
Motor Braking units Control units for Braking unit Front covers Cabinets (drive + braking unit) Motor Braking units Control units for Braking unit Front covers Cabinets (drive + braking unit)
braking units power modules for braking for IP 20/21/23/40/41/43/54 braking units power modules for braking for IP 20/21/23/40/41/43/54
units integration units integration
ND: Normal duty 600 mm width 800 mm width ND: Normal duty 600 mm width 800 mm width
HD: Heavy duty HD: Heavy duty
kW HP kW HP
Standard drives three-phase supply voltage: 400…480 V 50/60 Hz - reduced height version Standard drives three-phase supply voltage: 500…690 V 50/60 Hz - reduced height version
ND 110…160 1 x MODBUOC16Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 2 – ND 75…132 1 x MODBUOC20N6APM 1 x APMBC0CTLY6 1 x APMBC0C50Y6 – 2 –
HD 90…132 HD 55…110
1 x MODBUOC16R4APM
ND 110…200 1 x MODBUOC20Q6APM
ND 150…250 1 x MODBUOC16T4APM HD 90…160
HD 125…200
ND 175…200 1 x MODBUOC20T6APM
ND 200…315 1 x MODBUOC31Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 1 1 HD 150…175
HD 160…250 1 x MODBUOC31R4APM ND 160…280 1 x MODBUOC40N6APM 1 x APMBC0CTLY6 1 x APMBC0C50Y6 – 1 1
ND 300…500 1 x MODBUOC31T4APM HD 132…220
HD 250…400 ND 250…400 1 x MODBUOC40Q6APM
ND 355…500 1 x MODBUOC50Q4APM 1 x APMBC0CTLN4 1 x APMBC0C50N4 – 3 – HD 200…315
HD 280…400 1 x MODBUOC50R4APM ND 250…450 1 x MODBUOC40T6APM
HD 200…350
ND 550…700 1 x MODBUOC50T4APM
HD 450…600 ND 355…450 1 x MODBUOC63N6APM 1 x APMBC0CTLY6 1 x APMBC0C50Y6 – 3 –
HD 280…355
ND 560…630 2 x MODBUOC63Q4APM 1 x APMBC0CTLN4 2 x APMBC0C50N4 1 x VW3A97A01 5 –
HD 450…500 ND 500…630 1 x MODBUOC63Q6APM
2 x MODBUOC63R4APM HD 400…500
ND 800…900 2 x MODBUOC63T4APM ND 550…650 1 x MODBUOC63T6APM
HD 650…700 HD 450…550
ND 710…800 2 x MODBUOC80Q4APM 1 x APMBC0CTLN4 2 x APMBC0C50N4 1 x VW3A97A01 4 1 ND 560 2 x MODBUOC80N6APM 1 x APMBC0CTLY6 2 x APMBC0C50Y6 1 x VW3A97A01 5 –
HD 560…630 2 x MODBUOC80R4APM HD 450
ND 1000…1100 2 x MODBUOC80T4APM ND 800 2 x MODBUOC80Q6APM
HD 800…900 HD 630
ND 800 2 x MODBUOC80T6APM
Pages 71 27 27 23 (1) (2) HD 650
ND 710 2 x MODBUOM10N6APM 1 x APMBC0CTLY6 2 x APMBC0C50Y6 1 x VW3A97A01 4 1
HD 560
ND 1000 2 x MODBUOM10Q6APM
HD 800
ND 1000 2 x MODBUOM10T6APM
HD 800
ND 800 2 x MODBUOM12N6APM 1 x APMBC0CTLY6 2 x APMBC0C50Y6 1 x VW3A97A01 3 2
HD 710
ND 1200 2 x MODBUOM12Q6APM
HD 1000
ND 1200 2 x MODBUOM12T6APM
HD 1000

Pages 77 27 27 23 (1) (2)

(1) These cabinet recommendations are for standard integration. For flexible solutions, please contact your Schneider Electric supplier.
(2) Cabinets must have a minimum depth of 600 mm/23.6 in., and a minimum height of:
b 2,150 mm/84.6 in. (including the roof-top extension) for IP20/21/23/40/41/43 standard cabinet integration
b 2,350 mm/92.5 in. (including the plinth and roof-top extension) for IP54 standard cabinet integration

83
86 83
87
Combinations (continued) Variable speed drives Combinations (continued) Variable speed drives
Altivar Process Modular Altivar Process Modular
Standard liquid-cooled architectures without braking unit Standard liquid-cooled architectures without braking unit
Universal version 380...480 V power supply Universal version 500...690 V power supply

Table showing possible combinations to create architectures Table showing possible combinations to create architectures
Motor Drive Control Power Line choke Motor Cabinet Cabinets for Motor Drive Control Power Line choke Motor Cabinet Cabinets for
units modules module protection cooling IP 20/21/23/40/41/43/ units modules module protection cooling IP 20/21/23/40/41/43/
module module (3) 54/55/66 integration module module (3) 54/55/66 integration
ND: Normal duty 600 mm width ND: Normal duty 600 mm width
HD: Heavy duty HD: Heavy duty
kW HP kW HP
Standard liquid-cooled drives three-phase supply voltage: 380…480 V 50/60 Hz - Universal version Standard liquid-cooled drives three-phase supply voltage: 500…690 V 50/60 Hz - Universal version
ND 132…200 ATV6L0C13Q4…C20Q4 1 x APM6L0CTLN4 1 x APM1L0C20N4 1 x APM1L0LCMN4 1 x APM1L0MPMN4 1 x APM1L0CCM230 1 ND 132…200 ATV6L0C20N6…C28N6 1 x APM6L0CTLY6 1 x APM1L0C28Y6 1 x APM1L0LCMY6 1 x APM1L0MPMY6 1 x APM1L0CCM230 1
HD 110…160 ATV9L0C13Q4…C20Q4 1 x APM9L0CTLN4 HD 110…160 ATV9L0C20N6…C28N6 1 x APM9L0CTLY6
ND 250…315 ATV6L0C25Q4…C31Q4 1 x APM6L0CTLN4 1 x APM1L0C31N4 ND 220…315 ATV6L0C31N6…C45N6 1 x APM6L0CTLY6 1 x APM1L0C45Y6
HD 200…250 ATV9L0C25Q4…C31Q4 1 x APM9L0CTLN4 HD 180…250 ATV9L0C31N6…C45N6 1 x APM9L0CTLY6
ND 132…200 ATV6L0C13R4…C20R4 1 x APM6L0CTLN4 1 x APM1L0C20N4 ND 200…280 ATV6L0C20Q6…C28Q6 1 x APM6L0CTLY6 1 x APM1L0C28Y6
HD 110…160 ATV9L0C13R4…C20R4 1 x APM9L0CTLN4 HD 160…220 ATV9L0C20Q6…C28Q6 1 x APM9L0CTLY6
ND 250…315 ATV6L0C25R4…C31R4 1 x APM6L0CTLN4 1 x APM1L0C31N4 ND 315…450 ATV6L0C31Q6…C45Q6 1 x APM6L0CTLY6 1 x APM1L0C45Y6
HD 200…250 ATV9L0C25R4…C31R4 1 x APM9L0CTLN4 HD 250…355 ATV9L0C31Q6…C45Q6 1 x APM9L0CTLY6
ND 200…300 ATV6L0C13T4…C20T4 1 x APM6L0CTLN4 1 x APM1L0C20N4 1 x APM1L0CCM115 ND 200…300 ATV6L0C20T6…C28T6 1 x APM6L0CTLY6 1 x APM1L0C28Y6 1 x APM1L0CCM115
HD 150…250 ATV9L0C13T4…C20T4 1 x APM9L0CTLN4 HD 150…200 ATV9L0C20T6…C28T6 1 x APM9L0CTLY6
ND 400…500 ATV6L0C25T4…C31T4 1 x APM6L0CTLN4 1 x APM1L0C31N4 ND 350…500 ATV6L0C31T6…C45T6 1 x APM6L0CTLY6 1 x APM1L0C45Y6
HD 300…400 ATV9L0C25T4…C31T4 1 x APM9L0CTLN4 HD 250…400 ATV9L0C31T6…C45T6 1 x APM9L0CTLY6
ND 400 ATV6L0C40Q4 1 x APM6L0CTLN4 2 x APM1L0C20N4 2 x APM1L0LCMN4 2 x APM1L0MPMN4 2 x APM1L0CCM230 2 ND 400 ATV6L0C56N6 1 x APM6L0CTLY6 2 x APM1L0C28Y6 2 x APM1L0LCMY6 2 x APM1L0MPMY6 2 x APM1L0CCM230 2
HD 315 ATV9L0C40Q4 1 x APM9L0CTLN4 HD 315 ATV9L0C56N6 1 x APM9L0CTLY6
ND 500…630 ATV6L0C50Q4…C63Q4 1 x APM6L0CTLN4 2 x APM1L0C31N4 ND 500…630 ATV6L0C71N6…C90N6 1 x APM6L0CTLY6 2 x APM1L0C45Y6
HD 400…500 ATV9L0C50Q4…C63Q4 1 x APM9L0CTLN4 HD 400…500 ATV9L0C71N6…C90N6 1 x APM9L0CTLY6
ND 400 ATV6L0C40R4 1 x APM6L0CTLN4 2 x APM1L0C20N4 ND 560 ATV6L0C56Q6 1 x APM6L0CTLY6 2 x APM1L0C28Y6
HD 315 ATV9L0C40R4 1 x APM9L0CTLN4 HD 450 ATV9L0C56Q6 1 x APM9L0CTLY6
ND 500…630 ATV6L0C50R4…C63R4 1 x APM6L0CTLN4 2 x APM1L0C31N4 ND 710…900 ATV6L0C71Q6…C90Q6 1 x APM6L0CTLY6 2 x APM1L0C45Y6
HD 400…500 ATV9L0C50R4…C63R4 1 x APM9L0CTLN4 HD 560…710 ATV9L0C71Q6…C90Q6 1 x APM9L0CTLY6
ND 600 ATV6L0C40T4 1 x APM6L0CTLN4 2 x APM1L0C20N4 2 x APM1L0CCM115 ND 600 ATV6L0C56T6 1 x APM6L0CTLY6 2 x APM1L0C28Y6 2 x APM1L0CCM115
HD 500 ATV9L0C40T4 1 x APM9L0CTLN4 HD 500 ATV9L0C56T6 1 x APM9L0CTLY6
ND 700…900 ATV6L0C50T4…C63T4 1 x APM6L0CTLN4 2 x APM1L0C31N4 ND 700…900 ATV6L0C71T6…C90T6 1 x APM6L0CTLY6 2 x APM1L0C45Y6
HD 600…700 ATV9L0C50T4…C63T4 1 x APM9L0CTLN4 HD 600…700 ATV9L0C71T6…C90T6 1 x APM9L0CTLY6
ND 800…900 ATV6L0C80Q4…C90Q4 1 x APM6L0CTLN4 3 x APM1L0C31N4 3 x APM1L0LCMN4 3 x APM1L0MPMN4 3 x APM1L0CCM230 3 ND 800…1000 ATV6L0M12N6…M14N6 1 x APM6L0CTLY6 3 x APM1L0C45Y6 3 x APM1L0LCMY6 3 x APM1L0MPMY6 3 x APM1L0CCM230 3
HD 710…710 ATV9L0C80Q4…C90Q4 1 x APM9L0CTLN4 HD 710…800 ATV9L0M12N6…M14N6 1 x APM9L0CTLY6
ND 800…900 ATV6L0C80R4…C90R4 1 x APM6L0CTLN4 ND 1200…1400 ATV6L0M12Q6…M14Q6 1 x APM6L0CTLY6
HD 710…710 ATV9L0C80R4…C90R4 1 x APM9L0CTLN4 HD 1000…1100 ATV9L0M12Q6…M14Q6 1 x APM9L0CTLY6
ND 1100…1300 ATV6L0C80T4…C90T4 1 x APM6L0CTLN4 3 x APM1L0CCM115 ND 1200…1400 ATV6L0M12T6…M14T6 1 x APM6L0CTLY6 3 x APM1L0CCM115
HD 900…1000 ATV9L0C80T4…C90T4 1 x APM9L0CTLN4 HD 1000…1100 ATV9L0M12T6…M14T6 1 x APM9L0CTLY6
ND 1000…1200 ATV6L0M10Q4…M12Q4 1 x APM6L0CTLN4 4 x APM1L0C31N4 4 x APM1L0LCMN4 4 x APM1L0MPMN4 4 x APM1L0CCM230 4 ND 1200…1300 ATV6L0M16N6…M18N6 1 x APM6L0CTLY6 4 x APM1L0C45Y6 4 x APM1L0LCMY6 4 x APM1L0MPMY6 4 x APM1L0CCM230 4
HD 800…1000 ATV9L0M10Q4…M12Q4 1 x APM9L0CTLN4 HD 900…1000 ATV9L0M16N6…M18N6 1 x APM9L0CTLY6
ND 1000…1200 ATV6L0M10R4…M12R4 1 x APM6L0CTLN4 ND 1600…1800 ATV6L0M16Q6…M18Q6 1 x APM6L0CTLY6
HD 800…1000 ATV9L0M10R4…M12R4 1 x APM9L0CTLN4 HD 1300…1400 ATV9L0M16Q6…M18Q6 1 x APM9L0CTLY6
ND 1400…1700 ATV6L0M10T4…M12T4 1 x APM6L0CTLN4 4 x APM1L0CCM115 ND 1600…1800 ATV6L0M16T6…M18T6 1 x APM6L0CTLY6 4 x APM1L0CCM115
HD 1100…1400 ATV9L0M10T4…M12T4 1 x APM9L0CTLN4 HD 1300…1400 ATV9L0M16T6…M18T6 1 x APM9L0CTLY6
ND 1500 ATV6L0M15Q4 1 x APM6L0CTLN4 5 x APM1L0C31N4 5 x APM1L0LCMN4 5 x APM1L0MPMN4 5 x APM1L0CCM230 5 ND 1600 ATV6L0M22N6 1 x APM6L0CTLY6 5 x APM1L0C45Y6 5 x APM1L0LCMY6 5 x APM1L0MPMY6 5 x APM1L0CCM230 5
HD 1200 ATV9L0M15Q4 1 x APM9L0CTLN4 HD 1200 ATV9L0M22N6 1 x APM9L0CTLY6
ND 1500 ATV6L0M15R4 1 x APM6L0CTLN4 ND 2200 ATV6L0M22Q6 1 x APM6L0CTLY6
HD 1200 ATV9L0M15R4 1 x APM9L0CTLN4 HD 1700 ATV9L0M22Q6 1 x APM9L0CTLY6
ND 2200 ATV6L0M15T4 1 x APM6L0CTLN4 5 x APM1L0CCM115 ND 2200 ATV6L0M22T6 1 x APM6L0CTLY6 5 x APM1L0CCM115
HD 1700 ATV9L0M15T4 1 x APM9L0CTLN4 HD 1700 ATV9L0M22T6 1 x APM9L0CTLY6
ND 1800 ATV6L0M18Q4 1 x APM6L0CTLN4 6 x APM1L0C31N4 6 x APM1L0LCMN4 6 x APM1L0MPMN4 6 x APM1L0CCM230 6 ND 1900 ATV6L0M26N6 1 x APM6L0CTLY6 6 x APM1L0C45Y6 6 x APM1L0LCMY6 6 x APM1L0MPMY6 6 x APM1L0CCM230 6
HD 1400 ATV9L0M18Q4 1 x APM9L0CTLN4 HD 1500 ATV9L0M26N6 1 x APM9L0CTLY6
ND 1800 ATV6L0M18R4 1 x APM6L0CTLN4 ND 2600 ATV6L0M26Q6 1 x APM6L0CTLY6
HD 1400 ATV9L0M18R4 1 x APM9L0CTLN4 HD 2100 ATV9L0M26Q6 1 x APM9L0CTLY6
ND 2500 ATV6L0M18T4 1 x APM6L0CTLN4 6 x APM1L0CCM115 ND 2600 ATV6L0M26T6 1 x APM6L0CTLY6 6 x APM1L0CCM115
HD 2000 ATV9L0M18T4 1 x APM9L0CTLN4 HD 2100 ATV9L0M26T6 1 x APM9L0CTLY6

Pages 59 22 20 27 27 27 (1) (2) Pages 65 22 20 27 27 27 (1) (2)

(1) These cabinet recommendations are for standard integration. For flexible solutions, please contact your Schneider Electric supplier.
(2) Cabinets must have a minimum depth of 600 mm/23.6 in., and a minimum height of:
b 2,150 mm/84.6 in. (including the roof-top extension) for IP20/21/23/40/41/43 standard cabinet integration
b 2,350 mm/92.5 in. (including the plinth and roof-top extension) for IP54 standard cabinet integration
(3) Depending on the available control voltage, a module with 115 VAC or 230 VAC can be used.

88 89
Combinations (continued) Variable speed drives Combinations (continued) Variable speed drives
Altivar Process Modular Altivar Process Modular
Standard liquid-cooled architectures without braking unit Standard liquid-cooled architectures without braking unit
Compact version 380...480 V power supply Compact version 500...690 V power supply

Table showing possible combinations to create architectures Table showing possible combinations to create architectures
Motor Drive Control Power Line filter Line Motor Cabinets for IP Motor Drive Control Power Line filter Line Motor Cabinets for IP
units modules module paralleling protection 20/21/23/40/41/ units modules module paralleling protection 20/21/23/40/41/
module module 43/54/55/66 module module 43/54/55/66
integration integration
ND: Normal duty 400 600 800 ND: Normal duty 400 600 800
HD: Heavy duty mm mm mm HD: Heavy duty mm mm mm
kW HP width width width kW HP width width width
Standard liquid-cooled drives three-phase supply voltage: 380…480 V 50/60 Hz - Compact version Standard liquid-cooled drives three-phase supply voltage: 500…690 V 50/60 Hz - Compact version
ND 132…200 ATV6L0C13Q4…C20Q4 1 x APM6L0CTLN4 1 x APM1L0C20N4 1 x APM1L0LFMN4 1 x APM1L0LPMN4 1 x APM1L0MPMN4 1 – – ND 132…200 ATV6L0C20N6…C28N6 1 x APM6L0CTLY6 1 x APM1L0C28Y6 1 x APM1L0LFMY6 1 x APM1L0LPMY6 1 x APM1L0MPMY6 1 – –
HD 110…160 ATV9L0C13Q4…C20Q4 1 x APM9L0CTLN4 HD 110…160 ATV9L0C20N6…C28N6 1 x APM9L0CTLY6
ND 250…315 ATV6L0C25Q4…C31Q4 1 x APM6L0CTLN4 1 x APM1L0C31N4 ND 220…315 ATV6L0C31N6…C45N6 1 x APM6L0CTLY6 1 x APM1L0C45Y6
HD 200…250 ATV9L0C25Q4…C31Q4 1 x APM9L0CTLN4 HD 180…250 ATV9L0C31N6…C45N6 1 x APM9L0CTLY6
ND 132…200 ATV6L0C13R4…C20R4 1 x APM6L0CTLN4 1 x APM1L0C20N4 ND 200…280 ATV6L0C20Q6…C28Q6 1 x APM6L0CTLY6 1 x APM1L0C28Y6
HD 110…160 ATV9L0C13R4…C20R4 1 x APM9L0CTLN4 HD 160…220 ATV9L0C20Q6…C28Q6 1 x APM9L0CTLY6
ND 250…315 ATV6L0C25R4…C31R4 1 x APM6L0CTLN4 1 x APM1L0C31N4 ND 315…450 ATV6L0C31Q6…C45Q6 1 x APM6L0CTLY6 1 x APM1L0C45Y6
HD 200…250 ATV9L0C25R4…C31R4 1 x APM9L0CTLN4 HD 250…355
ATV9L0C31Q6…C45Q6 1 x APM9L0CTLY6
ND 200…300 ATV6L0C13T4…C20T4 1 x APM6L0CTLN4 1 x APM1L0C20N4 ND 200…300 ATV6L0C20T6…C28T6 1 x APM6L0CTLY6 1 x APM1L0C28Y6
HD 150…250 ATV9L0C13T4…C20T4 1 x APM9L0CTLN4 HD 150…200 ATV9L0C20T6…C28T6 1 x APM9L0CTLY6
ND 400…500 ATV6L0C25T4…C31T4 1 x APM6L0CTLN4 1 x APM1L0C31N4 ND 350…500 ATV6L0C31T6…C45T6 1 x APM6L0CTLY6 1 x APM1L0C45Y6
HD 300…400 ATV9L0C25T4…C31T4 1 x APM9L0CTLN4 HD 250…400 ATV9L0C31T6…C45T6 1 x APM9L0CTLY6
ND 400 ATV6L0C40Q4 1 x APM6L0CTLN4 2 x APM1L0C20N4 1 x APM1L0LFMN4 2 x APM1L0LPMN4 2 x APM1L0MPMN4 – 1 – ND 400 ATV6L0C56N6 1 x APM6L0CTLY6 2 x APM1L0C28Y6 1 x APM1L0LFMY6 2 x APM1L0LPMY6 2 x APM1L0MPMY6 – 1 –
HD 315 ATV9L0C40Q4 1 x APM9L0CTLN4 HD 315 ATV9L0C56N6 1 x APM9L0CTLY6
ND 500…630 ATV6L0C50Q4…C63Q4 1 x APM6L0CTLN4 2 x APM1L0C31N4 ND 500…630 ATV6L0C71N6…C90N6 1 x APM6L0CTLY6 2 x APM1L0C45Y6
HD 400…500 ATV9L0C50Q4…C63Q4 1 x APM9L0CTLN4 HD 400…500 ATV9L0C71N6…C90N6 1 x APM9L0CTLY6
ND 400 ATV6L0C40R4 1 x APM6L0CTLN4 2 x APM1L0C20N4 ND 560 ATV6L0C56Q6 1 x APM6L0CTLY6 2 x APM1L0C28Y6
HD 315 ATV9L0C40R4 1 x APM9L0CTLN4 HD 450 ATV9L0C56Q6 1 x APM9L0CTLY6
ND 500…630 ATV6L0C50R4…C63R4 1 x APM6L0CTLN4 2 x APM1L0C31N4 ND 710…900 ATV6L0C71Q6…C90Q6 1 x APM6L0CTLY6 2 x APM1L0C45Y6
HD 400…500 ATV9L0C50R4…C63R4 1 x APM9L0CTLN4 HD 560…710 ATV9L0C71Q6…C90Q6 1 x APM9L0CTLY6
ND 600 ATV6L0C40T4 1 x APM6L0CTLN4 2 x APM1L0C20N4 ND 600 ATV6L0C56T6 1 x APM6L0CTLY6 2 x APM1L0C28Y6
HD 500 ATV9L0C40T4 1 x APM9L0CTLN4 HD 500 ATV9L0C56T6 1 x APM9L0CTLY6
ND 700…900 ATV6L0C50T4…C63T4 1 x APM6L0CTLN4 2 x APM1L0C31N4 ND 700…900 ATV6L0C71T6…C90T6 1 x APM6L0CTLY6 2 x APM1L0C45Y6
HD 600…700 ATV9L0C50T4…C63T4 1 x APM9L0CTLN4 HD 600…700 ATV9L0C71T6…C90T6 1 x APM9L0CTLY6
ND 800…900 ATV6L0C80Q4…C90Q4 1 x APM6L0CTLN4 3 x APM1L0C31N4 1 x APM1L0LFMN4 3 x APM1L0LPMN4 3 x APM1L0MPMN4 – – 1 ND 800…1000 ATV6L0M12N6…M14N6 1 x APM6L0CTLY6 3 x APM1L0C45Y6 1 x APM1L0LFMY6 3 x APM1L0LPMY6 3 x APM1L0MPMY6 – – 1
HD 710…710 ATV9L0C80Q4…C90Q4 1 x APM9L0CTLN4 HD 710…800 ATV9L0M12N6…M14N6 1 x APM9L0CTLY6
ND 800…900 ATV6L0C80R4…C90R4 1 x APM6L0CTLN4 ND 1200…1400 ATV6L0M12Q6…M14Q6 1 x APM6L0CTLY6
HD 710…710 ATV9L0C80R4…C90R4 1 x APM9L0CTLN4 HD 1000…1100 ATV9L0M12Q6…M14Q6 1 x APM9L0CTLY6
ND 1100…1300 ATV6L0C80T4…C90T4 1 x APM6L0CTLN4 ND 1200…1400 ATV6L0M12T6…M14T6 1 x APM6L0CTLY6
HD 900…1000 ATV9L0C80T4…C90T4 1 x APM9L0CTLN4 HD 1000…1100 ATV9L0M12T6…M14T6 1 x APM9L0CTLY6
ND 1000…1200 ATV6L0M10Q4…M12Q4 1 x APM6L0CTLN4 4 x APM1L0C31N4 2 x APM1L0LFMN4 4 x APM1L0LPMN4 4 x APM1L0MPMN4 – 2 – ND 1200…1300 ATV6L0M16N6…M18N6 1 x APM6L0CTLY6 4 x APM1L0C45Y6 2 x APM1L0LFMY6 4 x APM1L0LPMY6 4 x APM1L0MPMY6 – 2 –
HD 800…1000 ATV9L0M10Q4…M12Q4 1 x APM9L0CTLN4 HD 900…1000 ATV9L0M16N6…M18N6 1 x APM9L0CTLY6
ND 1000…1200 ATV6L0M10R4…M12R4 1 x APM6L0CTLN4 ND 1600…1800 ATV6L0M16Q6…M18Q6 1 x APM6L0CTLY6
HD 800…1000 ATV9L0M10R4…M12R4 1 x APM9L0CTLN4 HD 1300…1400 ATV9L0M16Q6…M18Q6 1 x APM9L0CTLY6
ND 1400…1700 ATV6L0M10T4…M12T4 1 x APM6L0CTLN4 ND 1600…1800 ATV6L0M16T6…M18T6 1 x APM6L0CTLY6
HD 1100…1400 ATV9L0M10T4…M12T4 1 x APM9L0CTLN4 HD 1300…1400 ATV9L0M16T6…M18T6 1 x APM9L0CTLY6
ND 1500 ATV6L0M15Q4 1 x APM6L0CTLN4 5 x APM1L0C31N4 2 x APM1L0LFMN4 5 x APM1L0LPMN4 5 x APM1L0MPMN4 – 1 1 ND 1600 ATV6L0M22N6 1 x APM6L0CTLY6 5 x APM1L0C45Y6 2 x APM1L0LFMY6 5 x APM1L0LPMY6 5 x APM1L0MPMY6 – 1 1
HD 1200 ATV9L0M15Q4 1 x APM9L0CTLN4 HD 1200 ATV9L0M22N6 1 x APM9L0CTLY6
ND 1500 ATV6L0M15R4 1 x APM6L0CTLN4 ND 2200 ATV6L0M22Q6 1 x APM6L0CTLY6
HD 1200 ATV9L0M15R4 1 x APM9L0CTLN4 HD 1700 ATV9L0M22Q6 1 x APM9L0CTLY6
ND 2200 ATV6L0M15T4 1 x APM6L0CTLN4 ND 2200 ATV6L0M22T6 1 x APM6L0CTLY6
HD 1700 ATV9L0M15T4 1 x APM9L0CTLN4 HD 1700 ATV9L0M22T6 1 x APM9L0CTLY6
ND 1800 ATV6L0M18Q4 1 x APM6L0CTLN4 6 x APM1L0C31N4 2 x APM1L0LFMN4 6 x APM1L0LPMN4 6 x APM1L0MPMN4 – – 2 ND 1900 ATV6L0M26N6 1 x APM6L0CTLY6 6 x APM1L0C45Y6 2 x APM1L0LFMY6 6 x APM1L0LPMY6 6 x APM1L0MPMY6 – – 2
HD 1400 ATV9L0M18Q4 1 x APM9L0CTLN4 HD 1500 ATV9L0M26N6 1 x APM9L0CTLY6
ND 1800 ATV6L0M18R4 1 x APM6L0CTLN4 ND 2600 ATV6L0M26Q6 1 x APM6L0CTLY6
HD 1400 ATV9L0M18R4 1 x APM9L0CTLN4 HD 2100 ATV9L0M26Q6 1 x APM9L0CTLY6
ND 2500 ATV6L0M18T4 1 x APM6L0CTLN4 ND 2600 ATV6L0M26T6 1 x APM6L0CTLY6
HD 2000 ATV9L0M18T4 1 x APM9L0CTLN4 HD 2100 ATV9L0M26T6 1 x APM9L0CTLY6

Pages 59 22 20 27 27 27 (1) (2) Pages 65 22 20 27 27 27 (1) (2)
(1) These cabinet recommendations are for standard integration. For flexible solutions, please contact your Schneider Electric supplier.
(2) Cabinets must have a minimum depth of 600 mm/23.6 in., and a minimum height of:
b 2,150 mm/84.6 in. (including the roof-top extension) for IP20/21/23/40/41/43 standard cabinet integration
b 2,350 mm/92.5 in. (including the plinth and roof-top extension) for IP54 standard cabinet integration

90 91
Combinations (continued) Variable speed drives
Altivar Process Modular
Compatibility table

Module compatibility table

PF151298B
Safety module
Description Reference Compatibility Slot
Safety module VW3A3802 ATV900 C (2)

Encoder interface modules


Description Reference Compatibility Slot
Digital encoder interface module VW3A3420 ATV900 B

Analog encoder interface module VW3A3422 ATV900 B


A
Resolver interface module VW3A3423 ATV900 B

HTL encoder interface module VW3A3424 ATV900 B B

Additional I/O modules


Description Reference Compatibility Slot
Extended I/O module (1) VW3A3203 ATV600 and ATV900 A or B or C (2)

Extended relay module (1) VW3A3204 ATV600 and ATV900 A or B or C (2)

Fieldbus modules
Description Reference Compatibility Slot
EtherNet/IP and Modbus TCP dual port VW3A3720 ATV600 A
Altivar Process drives slots
EtherNet/IP, Modbus TCP, and MD-Link dual port VW3A3721 ATV600 A

CANopen daisy chain VW3A3608 ATV600 and ATV900 A

CANopen SUB-D VW3A3618 ATV600 and ATV900 A


For more information on compatible options and accessories, please contact your Schneider Electric supplier or consult the product selector
available on our partner portal.
CANopen screw terminal block VW3A3628 ATV600 and ATV900 A

PROFINET VW3A3627 ATV600 and ATV900 A For more details on I/O, encoder, and communication modules, please refer to the Altivar Process ATV600 and ATV900 catalogs:
Catalog Catalog

PROFIBUS DP V1 VW3A3607 ATV600 and ATV900 A

POWERLINK Network VW3A3619 ATV600 and ATV900 A

BACnet MS/TP VW3A3725 ATV600 A

EtherCAT VW3A3601 ATV900 A

DeviceNet VW3A3609 ATV600 and ATV900 A Altivar Process ATV600 Altivar Process ATV900
Variable speed drives
(1) These references can only be used once per drive, e.g. VW3A3203 in slot A and VW3A3204 in slot B. Variable speed drives

(2) The Altivar 900 drive must be equipped with an additional module support VW3A3800 to be able to insert the safety module VW3A3802.
se.com
www.se.com

Altivar Process catalogs


Click to open the documents

Presentation: Variable speed drives: Configuration and runtime tools: Dimensions: Presentation: Variable speed drives: Configuration and runtime tools: Dimensions:
page 10 page 30 page 28 page 20 page 10 page 30 page 28 page 20

86
92 86
93
Combinations for customer Variable speed drives
assembly Altivar Process Modular
Motor starters
IEC 400 V Standard drives

Applications
Circuit breaker/contactor/drive combinations help to ensure continuity of service in the installation.
The type of circuit breaker/contactor coordination selected can reduce maintenance costs in the event of a motor
short-circuit on the drive input by minimizing the time required to make the necessary repairs and the cost of
replacement equipment. The suggested combinations provide coordination according to the drive rating.
The selection according to IEC considers components loaded to a maximum of 80% up to 1600 A nominal current
to avoid the temperature rise test requirement according to IEC 61439-1.
The selection according to UL considers the requirement for disconnect switches not carrying full load currents
more than 80% of their nominal current.

The drive controls the motor, provides a monitoring function against short-circuits between the drive and the
motor, and helps protect the motor cable against overloads. Overload monitoring is provided by the drive’s motor
thermal monitoring function if this has been enabled. Otherwise, an external monitoring device such as a probe or
thermal overload relay must be provided.

Selecting short-circuit protection devices (fuses or circuit breakers) is key to helping to protect the overall
installation against potential damage caused by short-circuits. It is recommended that you refer to the APM
Integration Manuals.

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 400 V 50/60 Hz
ND 110 – ATV●A0C11Q4 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F225●● 280
NS1250N Micrologic 5.0 HD 90 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 132 – ATV●A0C13Q4 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
HD 110 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F225●● 280
ND 160 – ATV●A0C16Q4 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 132 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
ND 200 – ATV●A0C20Q4 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 160 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F400●● 430
ND 250 – ATV●A0C25Q4 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 200 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 315 – ATV●A0C31Q4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 250 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
LC1F1400pp ND 355 – ATV●A0C35Q4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 280 NS630N Micrologic 5.0 630 1260 (5) LC1F630●● 850
ND 400 – ATV●A0C40Q4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 315 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 450 – ATV●A0C45Q4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 355 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 500 – ATV●A0C50Q4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1250●● 1060
HD 400 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 560 – ATV●A0C56Q4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
HD 450 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 630 – ATV●A0C63Q4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
HD 500 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
ND 710 – ATV●A0C71Q4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F2100●● 1750
HD 560 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
ND 800 – ATV●A0C80Q4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (5) LC1F2100●● 1750
HD 630 NS1600N Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

ATV6A0C71Q4

94
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 440 V Standard drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 440 V 50/60 Hz
ND 110 – ATV●A0C11R4 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
NS800N Micrologic 5.0 HD 90 NSX250N Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 132 – ATV●A0C13R4 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F225●● 280
HD 110 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 160 – ATV●A0C16R4 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 132 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F225●● 280
ND 200 – ATV●A0C20R4 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F400●● 430
HD 160 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
ND 250 – ATV●A0C25R4 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 200 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F400●● 430
ND 315 – ATV●A0C31R4 NS630bN Micrologic 5.0 630 1260 (5) LC1F630●● 850
HD 250 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 355 – ATV●A0C35R4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 280 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
LC1F630pp
ND 400 – ATV●A0C40R4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 315 NS630bN Micrologic 5.0 630 1260 (5) LC1F630●● 850
ND 450 – ATV●A0C45R4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 355 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 500 – ATV●A0C50R4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 400 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 560 – ATV●A0C56R4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
HD 450 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 630 – ATV●A0C63R4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1700●● 1450
HD 500 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 710 – ATV●A0C71R4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
HD 560 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
ND 800 – ATV●A0C80R4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F2100●● 1750
HD 630 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1700●● 1450
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

ATV9A0C45R4

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

95
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
UL 480 V Standard drives

UL standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 480 V 50/60 Hz
ND – 150 ATV●A0C11T4 JLL36250U31X 250 500 (4) LC1F185●● 240
LLL36600U31X HD 125 JLL36250U31X 250 500 (4) LC1D115●● 200
ND – 200 ATV●A0C13T4 LLL36400U31X 400 800 (4) LC1F225●● 280
HD 150 JLL36250U31X 250 500 (4) LC1F185●● 240
ND – 250 ATV●A0C16T4 LLL36400U31X 400 800 (4) LC1F330●● 360
HD 200 LLL36400U31X 400 800 (4) LC1F225●● 280
ND – 300 ATV●A0C20T4 LLL36600U31X 600 1200 (4) LC1F400●● 430
HD 250 LLL36400U31X 400 800 (4) LC1F330●● 360
ND – 400 ATV●A0C25T4 LLL36600U31X 600 1200 (4) LC1F500●● 580
HD 300 LLL36600U31X 600 1200 (4) LC1F400●● 430
ND – 500 ATV●A0C31T4 PLL34080U31A 736 1600 (4) LC1F630●● 850
HD 400 LLL36600U31X 600 1200 (4) LC1F500●● 580
ND – 550 ATV●A0C35T4 PLL34080U31A 736 1600 (4) LC1F630●● 850
HD 450 PLL34080U31A 736 1600 (4) LC1F630●● 850
LC1F400●●
ND – 600 ATV●A0C40T4 PLL34100U44A 920 2000 (4) LC1F630●● 850
HD 500 PLL34080U31A 736 1600 (4) LC1F630●● 850
ND – 650 ATV●A0C45T4 PLL34100U44A 920 2000 (4) LC1F1250●● 1060
HD 550 PLL34080U31A 736 1600 (4) LC1F630●● 850
ND – 700 ATV●A0C50T4 PLL34100U44A 920 2000 (4) LC1F1250●● 1060
HD 600 PLL34100U44A 920 2000 (4) LC1F630●● 850
ND – 800 ATV●A0C56T4 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
HD 650 PLL34100U44A 920 2000 (4) LC1F1250●● 1060
ND – 900 ATV●A0C63T4 RLF36160U44A 1472 3200 (4) LC1F1400●● 1190
HD 700 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
ND – 1000 ATV●A0C71T4 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
HD 800 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
ND – 1100 ATV●A0C80T4 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
HD 900 RLF36160U44A 1472 3200 (4) LC1F1400●● 1190
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

ATV9A0C25T4

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

96
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 500 V and UL 600V Standard drives

IEC and UL standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 500 V 50/60 Hz
ND 75 – ATV●A0C11N6 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
JRL36250U31X HD 55 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D80●● 125
ND 90 – ATV●A0C13N6 NSX250L Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
HD 75 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
ND 110 – ATV●A0C16N6 NSX250L Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
HD 90 NSX250L Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 132 – ATV●A0C20N6 NSX250L Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
HD 110 NSX250L Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 160 – ATV●A0C25N6 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
HD 132 NSX250L Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 220 – ATV●A0C31N6 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F400●● 430
HD 160 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
ND 280 – ATV●A0C40N6 NSX630L Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
LC1D115●●
HD 220 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F400●● 430
ND 355 – ATV●A0C50N6 NS630bH Micrologic 5.0 630 1260 (5) LC1F630●● 850
HD 280 NSX630L Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 450 – ATV●A0C63N6 NS800H Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 355 NS630bH Micrologic 5.0 630 1260 (5) LC1F630●● 850
ND 560 – ATV●A0C80N6 NS1000H Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 450 NS800H Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 710 – ATV●A0M10N6 NS1250H Micrologic 5.0 1250 2500 (5) LC1F1700●● 1450
HD 560 NS1000H Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 800 – ATV●A0M12N6 NS1600H Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
HD 710 NS1250H Micrologic 5.0 1250 2500 (5) LC1F1700●● 1450

Three-phase supply voltage: 600 V 50/60 Hz


ND – 125 ATV●A0C11T6 HRL36150U31X 150 300 (4) LC1D115●● 200
HD 100 HRL36150U31X 150 300 (4) LC1D80●● 125
ND – 150 ATV●A0C13T6 JRL36250U31X 250 500 (4) LC1D115●● 200
HD 125 HRL36150U31X 150 300 (4) LC1D115●● 200
ND – 175 ATV●A0C16T6 JRL36250U31X 250 500 (4) LC1D115●● 200
HD 150 JRL36250U31X 250 500 (4) LC1D115●● 200
ATV6A0C13T6
ND – 200 ATV●A0C20T6 JRL36250U31X 250 500 (4) LC1F185●● 240
HD 175 JRL36250U31X 250 500 (4) LC1D115●● 200
ND – 250 ATV●A0C25T6 LRL36400U31X 400 800 (4) LC1F225●● 280
HD 200 JRL36250U31X 250 500 (4) LC1F185●● 240
ND – 350 ATV●A0C31T6 LRL36400U31X 400 800 (4) LC1F400●● 430
HD 250 LRL36400U31X 400 800 (4) LC1F225●● 280
ND – 450 ATV●A0C40T6 LRL36600U31X 600 1200 (4) LC1F500●● 580
HD 350 LRL36400U31X 400 800 (4) LC1F400●● 430
ND – 550 ATV●A0C50T6 LRL36600U31X 600 1200 (4) LC1F500●● 580
HD 450 LRL36600U31X 600 1200 (4) LC1F500●● 580
ND – 650 ATV●A0C63T6 MTZ2 08L Micrologic 3.0 X 736 1600 (4) LC1F630●● 850
HD 550 LRL36600U31X 600 1200 (4) LC1F500●● 580
ND – 800 ATV●A0C80T6 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F630●● 850
HD 650 MTZ2 08L Micrologic 3.0 X 736 1600 (4) LC1F630●● 850
ND – 1000 ATV●A0M10T6 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F1250●● 1060
HD 800 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F630●● 850
ND – 1200 ATV●A0M12T6 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F1700●● 1450
HD 1000 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F1250●● 1060
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

97
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 690 V Standard drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 690 V 50/60 Hz
ND 110 – ATV●A0C11Q6 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
NSX400HB1 Micrologic 2.3 400 HD 90 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D80●● 125
ND 132 – ATV●A0C13Q6 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
HD 110 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
ND 160 – ATV●A0C16Q6 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
HD 132 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 200 – ATV●A0C20Q6 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1F225●● 280
HD 160 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 250 – ATV●A0C25Q6 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 200 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F225●● 280
ND 315 – ATV●A0C31Q6 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F400●● 430
HD 250 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
ND 400 – ATV●A0C40Q6 NSX630HB1 Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 315 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F400●● 430
LC1F330●●
ND 500 – ATV●A0C50Q6 NS630bLB Micrologic 5.0 630 1260 (5) LC1F630●● 850
HD 400 NSX630HB1 Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 630 – ATV●A0C63Q6 NS800LB Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 500 NS630bLB Micrologic 5.0 630 1260 (5) LC1F630●● 850
ND 800 – ATV●A0C80Q6 MTZ2 10H1 Micrologic 5.0 X 1000 2000 (5) LC1F1250●● 1060
HD 630 NS800LB Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 1000 – ATV●A0M10Q6 MTZ2 12H1 Micrologic 5.0 X 1250 2500 (5) LC1F1700●● 1450
HD 800 MTZ2 10H1 Micrologic 5.0 X 1000 2000 (5) LC1F1250●● 1060
ND 1200 – ATV●A0M12Q6 MTZ2 16H1 Micrologic 5.0 X 1600 3200 (5) LC1F2100●● 1750
HD 1000 MTZ2 12H1 Micrologic 5.0 X 1250 2500 (5) LC1F1700●● 1450
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

ATV9A0C25Q6

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

98
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 400 V Low Harmonic/Regen drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 400 V 50/60 Hz
ND 110 – ATV●B0C11Q4 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F225●● 280
NSX630N Micrologic 2.3 630 HD 90 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 132 – ATV●B0C13Q4 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
HD 110 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F225●● 280
ND 160 – ATV●B0C16Q4 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 132 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
ND 200 – ATV●B0C20Q4 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 160 NSX400N Micrologic 2.3 400 400 4800 (4) LC1F400●● 430
ND 250 – ATV●B0C25Q4 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 200 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 315 – ATV●B0C31Q4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 250 NSX630N Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 355 – ATV●B0C35Q4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 280 NS630bN Micrologic 5.0 630 1260 (5) LC1F630●● 850
LC1F500●●
ND 400 – ATV●B0C40Q4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 315 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 450 – ATV●B0C45Q4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 355 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 500 – ATV●B0C50Q4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1250●● 1060
HD 400 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 560 – ATV●B0C56Q4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
HD 450 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 630 – ATV●B0C63Q4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
HD 500 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
ND 710 – ATV●B0C71Q4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F2100●● 1750
HD 560 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
ND 800 – ATV●B0C80Q4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (5) LC1F2100●● 1750
HD 630 NS1600N Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

ATV9B0C25Q4

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

99
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 440 V Low Harmonic/Regen drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 440 V 50/60 Hz
ND 110 – ATV●B0C11R4 NSX250N Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
NSX250N Micrologic 2.2 250 HD 90 NSX250N Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 132 – ATV●B0C13R4 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
HD 110 NSX250N Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 160 – ATV●B0C16R4 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
HD 132 NSX250N Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 200 – ATV●B0C20R4 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 160 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
ND 250 – ATV●B0C25R4 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 200 NSX400H Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
ND 315 – ATV●B0C31R4 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 250 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 355 – ATV●B0C35R4 NS630bN Micrologic 5.0 630 1260 (5) LC1F630●● 850
HD 280 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
LC1D115●●
ND 400 – ATV●B0C40R4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 315 NSX630H Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 450 – ATV●B0C45R4 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 355 NS630bN Micrologic 5.0 630 1260 (5) LC1F630●● 850
ND 500 – ATV●B0C50R4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 400 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 560 – ATV●B0C56R4 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 450 NS800N Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 630 – ATV●B0C63R4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
HD 500 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 710 – ATV●B0C71R4 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1700●● 1450
HD 560 NS1000N Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 800 – ATV●B0C80R4 NS1600N Micrologic 5.0 1600 3200 (5) LC1F1700●● 1450
HD 630 NS1250N Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

ATV6B0C11R4

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

100
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
UL 480 V Low Harmonic/Regen drives

UL standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 480 V 50/60 Hz
ND – 150 ATV●B0C11T4 JLL36250U31X 250 500 (4) LC1D115●● 200
RLF36160U44A HD 125 JLL36250U31X 250 500 (4) LC1D115●● 200
ND – 200 ATV●B0C13T4 JLL36250U31X 250 500 (4) LC1F225●● 280
HD 150 JLL36250U31X 250 500 (4) LC1D115●● 200
ND – 250 ATV●B0C16T4 LLL36400U31X 400 800 (4) LC1F330●● 360
HD 200 JLL36250U31X 250 500 (4) LC1F225●● 280
ND – 300 ATV●B0C20T4 LLL36400U31X 400 800 (4) LC1F400●● 430
HD 250 LLL36400U31X 400 800 (4) LC1F330●● 360
ND – 400 ATV●B0C25T4 LLL36600U31X 600 1200 (4) LC1F500●● 580
HD 300 LLL36400U31X 400 800 (4) LC1F400●● 430
ND – 500 ATV●B0C31T4 PLL34080U31A 736 1600 (4) LC1F630●● 850
HD 400 LLL36600U31X 600 1200 (4) LC1F500●● 580
ND – 550 ATV●B0C35T4 PLL34080U31A 736 1600 (4) LC1F630●● 850
HD 450 LLL36600U44X 600 1200 (4) LC1F500●● 580
LC1F1700●●
ND – 600 ATV●B0C40T4 PLL34080U31A 736 1600 (4) LC1F630●● 850
HD 500 PLL34080U31A 736 1600 (4) LC1F630●● 850
ND – 650 ATV●B0C45T4 PLL34100U44A 920 2000 (4) LC1F630●● 850
HD 550 PLL34080U31A 736 1600 (4) LC1F630●● 850
ND – 700 ATV●B0C50T4 PLL34100U44A 920 2000 (4) LC1F630●● 850
HD 600 PLL34080U31A 736 1600 (4) LC1F630●● 850
ND – 800 ATV●B0C56T4 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
HD 650 PLL34100U44A 920 2000 (4) LC1F630●● 850
ND – 900 ATV●B0C63T4 PLL34120U44A 1104 2400 (4) LC1F1400●● 1190
HD 700 PLL34100U44A 920 2000 (4) LC1F630●● 850
ND – 1000 ATV●B0C71T4 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
HD 800 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
ATV9B0C80T4 ND – 1100 ATV●B0C80T4 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
HD 900 PLL34120U44A 1104 2400 (4) LC1F1400●● 1190
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

101
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 500 V and UL 600V Low Harmonic/Regen drives

IEC and UL standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 500 V 50/60 Hz
ND 75 – ATV●B0C11N6 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D80●● 125
LRL36600U31X HD 55 NSX100L Micrologic 2.2 100 100 1500 (4) LC1D80●● 125
ND 90 – ATV●B0C13N6 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
HD 75 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D80●● 125
ND 110 – ATV●B0C16N6 NSX250L Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
HD 90 NSX160L Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
ND 132 – ATV●B0C20N6 NSX250L Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
HD 110 NSX250L Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 160 – ATV●B0C25N6 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F225●● 280
HD 132 NSX250L Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 220 – ATV●B0C31N6 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 160 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F225●● 280
ND 280 – ATV●B0C40N6 NSX630L Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
LC1F500●
HD 220 NSX400L Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
ND 355 – ATV●B0C50N6 NSX630L Micrologic 2.3 630 600 6900 (4) LC1F630●● 850
HD 280 NSX630L Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 450 – ATV●B0C63N6 NS800H Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 355 NSX630L Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 560 – ATV●B0C80N6 NS1000H Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
HD 450 NS800H Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 710 – ATV●B0M10N6 NS1250H Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190
HD 560 NS1000H Micrologic 5.0 1000 2000 (5) LC1F1250●● 1060
ND 800 – ATV●B0M12N6 NS1250H Micrologic 5.0 1250 2500 (5) LC1F1700●● 1450
HD 710 NS1250H Micrologic 5.0 1250 2500 (5) LC1F1400●● 1190

Three-phase supply voltage: 600 V 50/60 Hz


ND – 125 ATV●B0C11T6 HRL36150U31X 150 300 (4) LC1D115●● 200
HD 100 HRL36150U31X 150 300 (4) LC1D80●● 125
ND – 150 ATV●B0C13T6 JRL36250U31X 250 500 (4) LC1D115●● 200
ATV6A0C50T6 HD 125 HRL36150U31X 150 300 (4) LC1D115●● 200
ND – 175 ATV●B0C16T6 JRL36250U31X 250 500 (4) LC1D115●● 200
HD 150 JRL36250U31X 250 500 (4) LC1D115●● 200
ND – 200 ATV●B0C20T6 JRL36250U31X 250 500 (4) LC1F185●● 240
HD 175 JRL36250U31X 250 500 (4) LC1D115●● 200
ND – 250 ATV●B0C25T6 JRL36250U31X 250 500 (4) LC1F225●● 280
HD 200 JRL36250U31X 250 500 (4) LC1D115●● 200
ND – 350 ATV●B0C31T6 LRL36400U31X 400 800 (4) LC1F330●● 360
HD 250 JRL36250U31X 250 500 (4) LC1F225●● 280
ND – 450 ATV●B0C40T6 LRL36600U31X 600 1200 (4) LC1F500●● 580
HD 350 LRL36400U31X 400 800 (4) LC1F330●● 360
ND – 550 ATV●B0C50T6 LRL36600U31X 600 1200 (4) LC1F500●● 580
HD 450 LRL36600U31X 600 1200 (4) LC1F500●● 580
ND – 650 ATV●B0C63T6 MTZ2 08L Micrologic 3.0 X 736 1600 (4) LC1F630●● 850
HD 550 LRL36600U31X 600 1200 (4) LC1F500●● 580
ND – 800 ATV●B0C80T6 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F630●● 850
HD 650 MTZ2 08L Micrologic 3.0 X 736 1600 (4) LC1F630●● 850
ND – 1000 ATV●B0M10T6 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F1250●● 1060
HD 800 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F630●● 850
ND – 1200 ATV●B0M12T6 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F1400●● 1190
HD 1000 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F1250●● 1060
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

102
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 690 V Low Harmonic/Regen drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 690 V 50/60 Hz
ND 110 – ATV●B0C11Q6 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
MTZ2 16H1 HD 90 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D80●● 125
ND 132 – ATV●B0C13Q6 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
HD 110 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
ND 160 – ATV●B0C16Q6 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
HD 132 NSX250HB1 Micrologic 2.2 160 160 2400 (4) LC1D115●● 200
ND 200 – ATV●B0C20Q6 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
HD 160 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1D115●● 200
ND 250 – ATV●B0C25Q6 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
HD 200 NSX250HB1 Micrologic 2.2 250 250 3000 (4) LC1F185●● 240
ND 315 – ATV●B0C31Q6 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
HD 250 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F265●● 300
ND 400 – ATV●B0C40Q6 NSX630HB1 Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 315 NSX400HB1 Micrologic 2.3 400 400 4800 (4) LC1F330●● 360
LC1F1700●●
ND 500 – ATV●B0C50Q6 NSX630HB1 Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
HD 400 NSX630HB1 Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 630 – ATV●B0C63Q6 NS800LB Micrologic 5.0 800 1600 (5) LC1F630●● 850
HD 500 NSX630HB1 Micrologic 2.3 630 600 6900 (4) LC1F500●● 580
ND 800 – ATV●B0C80Q6 MTZ2 10H1 Micrologic 5.0 X 1000 2000 (5) LC1F1250●● 1060
HD 630 NS800LB Micrologic 5.0 800 1600 (5) LC1F630●● 850
ND 1000 – ATV●B0M10Q6 MTZ2 12H1 Micrologic 5.0 X 1250 2500 (5) LC1F1400●● 1190
HD 800 MTZ2 10H1 Micrologic 5.0 X 1000 2000 (5) LC1F1250●● 1060
ND 1200 – ATV●B0M12Q6 MTZ2 16H1 Micrologic 5.0 X 1600 3200 (5) LC1F1700●● 1450
HD 1000 MTZ2 12H1 Micrologic 5.0 X 1250 2500 (5) LC1F1400●● 1190
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
ATV6B0M10Q6 (4) Rated instantaneous short-circuit current setting Ii: fixed
(5) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

103
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 400 V - 6-pulse Liquid-cooled drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 400 V 50/60 Hz
ND 132 – ATV●L0C13Q4 NSX400N Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
NS1000N Micrologic 5.0 HD 110 NSX400N Micrologic 2.3 400 400 4800 (5) LC1F225●● 280
ND 160 – ATV●L0C16Q4 NSX400N Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
HD 132 NSX400N Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
ND 200 – ATV●L0C20Q4 NSX630N Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
HD 160 NSX400N Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
ND 250 – ATV●L0C25Q4 NSX630N Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
HD 200 NSX630N Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
ND 315 – ATV●L0C31Q4 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
HD 250 NSX630N Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
ND 400 – ATV●L0C40Q4 NS1000N Micrologic 5.0 1000 2000 (6) LC1F1250●● 1060
HD 315 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
ND 500 – ATV●L0C50Q4 NS1250N Micrologic 5.0 1250 2500 (6) LC1F1250●● 1060
HD 400 NS1000N Micrologic 5.0 1000 2000 (6) LC1F1250●● 1060
LC1F1250●●
ND 630 – ATV●L0C63Q4 NS1600N Micrologic 5.0 1600 3200 (6) LC1F1700●● 1450
HD 500 NS1250N Micrologic 5.0 1250 2500 (6) LC1F1250●● 1060
ND 800 – ATV●L0C80Q4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
HD 630 NS1600N Micrologic 5.0 1600 3200 (6) LC1F1700●● 1450
ND 900 – ATV●L0C90Q4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
HD 710 NS1600N Micrologic 5.0 1600 3200 (6) LC1F2100●● 1750
ND 1000 – ATV●L0M10Q4 (4) MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
HD 800 ATV●L0M10Q4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
ND 1200 – ATV●L0M12Q4 (4) MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
HD 1000 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
ND 1500 – ATV●L0M15Q4 (4) MTZ2 32H1 Micrologic 5.0 X 3200 6400 (6) LC1F2600●● 2600
HD 1200 MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
ND 1800 – ATV●L0M18Q4 (4) MTZ2 32H1 Micrologic 5.0 X 3200 6400 (6) 3 x LC1F1700●● 3262
HD 1400 MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) A temperature rise test is required to fulfill IEC 61439-1.
ATV9L0C50Q4 (5) Rated instantaneous short-circuit current setting Ii: fixed
(6) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

104
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 440 V - 6-pulse Liquid-cooled drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 440 V 50/60 Hz
ND 132 – ATV●L0C13R4 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F265●● 300
NSX400H Micrologic 2.3 400 HD 110 NSX250N Micrologic 2.2 250 250 3000 (5) LC1F225●● 280
ND 160 – ATV●L0C16R4 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
HD 132 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F265●● 300
ND 200 – ATV●L0C20R4 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F400●● 430
HD 160 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
ND 250 – ATV●L0C25R4 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
HD 200 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F400●● 430
ND 315 – ATV●L0C31R4 NS630bN Micrologic 5.0 630 1260 (6) LC1F630●● 850
HD 250 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
ND 400 – ATV●L0C40R4 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
HD 315 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
ND 500 – ATV●L0C50R4 NS1000N Micrologic 5.0 1000 2000 (6) LC1F1250●● 1060
HD 400 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
LC1F265●●
ND 630 – ATV●L0C63R4 NS1250N Micrologic 5.0 1250 2500 (6) LC1F1700●● 1450
HD 500 NS1000N Micrologic 5.0 1000 2000 (6) LC1F1250●● 1060
ND 800 – ATV●L0C80R4 NS1600N Micrologic 5.0 1600 3200 (6) LC1F2100●● 1750
HD 630 NS1250N Micrologic 5.0 1250 2500 (6) LC1F1700●● 1450
ND 900 – ATV●L0C90R4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
HD 710 NS1600N Micrologic 5.0 1600 3200 (6) LC1F1700●● 1450
ND 1000 – ATV●L0M10R4 (4) MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
HD 800 ATV●L0M10R4 NS1600N Micrologic 5.0 1600 3200 (6) LC1F2100●● 1750
ND 1200 – ATV●L0M12R4 (4) MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
HD 1000 ATV●L0M12R4 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
ND 1500 – ATV●L0M15R4 (4) MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
HD 1200 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
ND 1800 – ATV●L0M18R4 (4) MTZ2 32H1 Micrologic 5.0 X 3200 6400 (6) 3 x LC1F1700●● 3262
HD 1400 MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
ATV9L0C13R4 (4) A temperature rise test is required to fulfill IEC 61439-1.
(5) Rated instantaneous short-circuit current setting Ii: fixed
(6) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

105
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
UL 480 V - 6-pulse Liquid-cooled drives

UL standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 480 V 50/60 Hz
ND – 200 ATV●L0C13T4 LLL36400U31X 400 800 (4) LC1F265●● 300
RLF36160U44A HD 150 JLL36250U31X 250 500 (4) LC1F185●● 240
ND – 250 ATV●L0C16T4 LLL36400U31X 400 800 (4) LC1F330●● 360
HD 200 LLL36400U31X 400 800 (4) LC1F265●● 300
ND – 300 ATV●L0C20T4 LLL36600U31X 600 1200 (4) LC1F400●● 430
HD 250 LLL36400U31X 400 800 (4) LC1F330●● 360
ND – 400 ATV●L0C25T4 LLL36600U31X 600 1200 (4) LC1F500●● 580
HD 300 LLL36600U31X 600 1200 (4) LC1F400●● 430
ND – 500 ATV●L0C31T4 PLL34080U31A 736 1600 (4) LC1F630●● 850
HD 400 LLL36600U31X 600 1200 (4) LC1F500●● 580
ND – 600 ATV●L0C40T4 PLL34100U44A 920 2000 (4) LC1F630●● 850
HD 500 PLL34080U31A 736 1600 (4) LC1F630●● 850
ND – 700 ATV●L0C50T4 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
HD 600 PLL34100U44A 920 2000 (4) LC1F630●● 850
LC1F1400●●
ND – 900 ATV●L0C63T4 RLF36160U44A 1472 3200 (4) LC1F1400●● 1190
HD 700 PLL34120U44A 1104 2400 (4) LC1F1250●● 1060
ND – 1100 ATV●L0C80T4 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
HD 900 RLF36160U44A 1472 3200 (4) LC1F1400●● 1190
ND – 1300 ATV●L0C90T4 RLF36200U44A 1840 4000 (4) LC1F2100●● 1750
HD 1000 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
ND – 1400 ATV●L0M10T4 RLF36200U44A 1840 4000 (4) LC1F2600●● 2600
HD 1100 RLF36160U44A 1472 3200 (4) LC1F1700●● 1450
ND – 1700 ATV●L0M12T4 RLF36250U44A 2300 5000 (4) LC1F2600●● 2600
HD 1400 RLF36200U44A 1840 4000 (4) LC1F2600●● 2600
ND – 2200 ATV●L0M15T4 MTZ3 40H Micrologic 6.0 X 3680 8000 (4) 3 x LC1F1700●● 3262
HD 1700 RLF36250U44A 2300 5000 (4) LC1F2600●● 2600
ND – 2500 ATV●L0M18T4 MTZ3 40H Micrologic 6.0 X 3680 8000 (4) 3 x LC1F1700●● 3262
HD 2000 RLF36300U44A 2760 6000 (4) LC1F2600●● 2600
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
ATV6L0C80T4 (2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

106
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 500 V - 6-pulse Liquid-cooled drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 500 V 50/60 Hz
ND 132 – ATV●L0C20N6 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F265●● 300
MTZ2 20H1 HD 110 NSX250N Micrologic 2.2 250 250 3000 (5) LC1F225●● 280
ND 200 – ATV●L0C28N6 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
HD 160 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F265●● 300
ND 220 – ATV●L0C31N6 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F400●● 430
HD 180 NSX400H Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
ND 250 – ATV●L0C40N6 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
HD 220 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F400●● 430
ND 315 – ATV●L0C45N6 NS630bN Micrologic 5.0 630 1260 (5) LC1F630●● 850
HD 250 NSX630H Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
ND 400 – ATV●L0C56N6 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
HD 315 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
ND 500 – ATV●L0C71N6 NS1000N Micrologic 5.0 1000 2000 (6) LC1F1250●● 1060
HD 400 NS800N Micrologic 5.0 800 1600 (6) LC1F630●● 850
LC1F2600●●
ND 630 – ATV●L0C90N6 NS1250N Micrologic 5.0 1250 2500 (6) LC1F1700●● 1450
HD 500 NS1000N Micrologic 5.0 1000 2000 (6) LC1F1250●● 1060
ND 800 – ATV●L0M12N6 NS1600N Micrologic 5.0 1600 3200 (6) LC1F2100●● 1750
HD 710 NS1250N Micrologic 5.0 1250 2500 (6) LC1F1700●● 1450
ND 1000 – ATV●L0M14N6 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
HD 800 NS1600N Micrologic 5.0 1600 3200 (6) LC1F1700●● 1450
ND 1200 – ATV●L0M16N6 (4) MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
HD 900 ATV●L0M16N6 NS1600N Micrologic 5.0 1600 3200 (6) LC1F2100●● 1750
ND 1300 – ATV●L0M18N6 (4) MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
HD 1000 ATV●L0M18N6 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
ND 1600 – ATV●L0M22N6 (4) MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
HD 1200 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
ND 1900 – ATV●L0M26N6 (4) MTZ2 32H1 Micrologic 5.0 X 3200 6400 (6) 3 x LC1F1700●● 3262
HD 1500 MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
ATV6L0M18N6 (1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) A temperature rise test is required to fulfill IEC 61439-1.
(5) Rated instantaneous short-circuit current setting Ii: fixed
(6) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

107
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
UL 600 V - 6-pulse Liquid-cooled drives

UL standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 600 V 50/60 Hz
ND – 200 ATV●L0C20T6 JRL36250U31X 250 500 (4) LC1F185●● 240
MTZ2 12L HD 150 JRL36250U31X 250 500 (4) LC1D115●● 200
ND – 300 ATV●L0C28T6 LRL36400U31X 400 800 (4) LC1F330●● 360
HD 200 JRL36250U31X 250 500 (4) LC1F185●● 240
ND – 350 ATV●L0C31T6 LRL36400U31X 400 800 (4) LC1F400●● 430
HD 250 LRL36400U31X 400 800 (4) LC1F225●● 280
ND – 450 ATV●L0C40T6 LRL36600U31X 600 1200 (4) LC1F500●● 580
HD 350 LRL36400U31X 400 800 (4) LC1F400●● 430
ND – 500 ATV●L0C45T6 LRL36600U31X 600 1200 (4) LC1F500●● 580
HD 400 LRL36600U31X 600 1200 (4) LC1F400●● 430
ND – 600 ATV●L0C56T6 MTZ2 08L Micrologic 3.0 X 736 1600 (4) LC1F630●● 850
HD 500 LRL36600U31X 600 1200 (4) LC1F500●● 580
ND – 700 ATV●L0C71T6 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F630●● 850
HD 600 MTZ2 08L Micrologic 3.0 X 736 1600 (4) LC1F630●● 850
LC1F1250●●
ND – 900 ATV●L0C90T6 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F1250 1060
HD 700 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F630●● 850
ND – 1200 ATV●L0M12T6 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F1700●● 1450
HD 1000 MTZ2 12L Micrologic 6.0 X 1104 2400 (4) LC1F1250●● 1060
ND – 1400 ATV●L0M14T6 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F1700●● 1450
HD 1100 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F1400●● 1190
ND – 1600 ATV●L0M16T6 MTZ2 20L Micrologic 6.0 X 1840 4000 (4) LC1F2100●● 1750
HD 1300 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F1700●● 1450
ND – 1800 ATV●L0M18T6 MTZ2 25L Micrologic 6.0 X 2300 5000 (4) LC1F2600●● 2600
HD 1400 MTZ2 16L Micrologic 6.0 X 1472 3200 (4) LC1F2100●● 1750
ND – 2200 ATV●L0M22T6 MTZ2 25L Micrologic 6.0 X 2300 5000 (4) LC1F2600●● 2600
HD 1700 MTZ2 20L Micrologic 6.0 X 1840 4000 (4) LC1F2600●● 2600
ND – 2600 ATV●L0M26T6 MTZ2 30L Micrologic 6.0 X 2760 6000 (4) 3 x LC1F1700●● 3262
HD 2100 MTZ2 25L Micrologic 6.0 X 2300 5000 (4) LC1F2600●● 2600
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
ATV6L0M12T6 (2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

108
Combinations for customer Variable speed drives
assembly (continued) Altivar Process Modular
Motor starters
IEC 690 V - 6-pulse Liquid-cooled drives

IEC standard motor starters


Nominal power Drive Circuit breaker Line contactor
ND: Normal duty Reference (1) Type (2) Rating li Reference (3) Rating
HD: Heavy duty at 50 °C at 60 °C
kW HP A A A A
Three-phase supply voltage: 690 V 50/60 Hz
ND 200 – ATV●L0C20Q6 NSX400HB1 Micrologic 2.3 400 400 4800 (5) LC1F225●● 280
MTZ2 32H1 HD 160 NSX250HB1 Micrologic 2.2 250 250 3000 (5) LC1F185●● 240
ND 280 – ATV●L0C28Q6 NSX400HB1 Micrologic 2.3 400 400 4800 (5) LC1F400●● 430
HD 220 NSX400HB1 Micrologic 2.3 400 400 4800 (5) LC1F265●● 300
ND 315 – ATV●L0C31Q6 NSX630HB1 Micrologic 2.3 630 600 6900 (5) LC1F400●● 430
HD 250 NSX400HB1 Micrologic 2.3 400 400 4800 (5) LC1F330●● 360
ND 400 – ATV●L0C40Q6 NSX630HB1 Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
HD 315 NSX630HB1 Micrologic 2.3 630 600 6900 (5) LC1F400●● 430
ND 450 – ATV●L0C45Q6 NSX630HB1 Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
HD 355 NSX630HB1 Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
ND 560 – ATV●L0C56Q6 NS800LB Micrologic 5.0 800 1600 (6) LC1F630●● 850
HD 450 NSX630HB1 Micrologic 2.3 630 600 6900 (5) LC1F500●● 580
ND 710 – ATV●L0C71Q6 MTZ2 10H1 Micrologic 5.0 X 1000 2000 (6) LC1F1250●● 1060
HD 560 NS800LB Micrologic 5.0 800 1600 (6) LC1F630●● 850
LC1F2600●●
ND 900 – ATV●L0C90Q6 MTZ2 12H1 Micrologic 5.0 X 1250 2500 (6) LC1F1400●● 1190
HD 710 MTZ2 10H1 Micrologic 5.0 X 1000 2000 (6) LC1F1250●● 1060
ND 1200 – ATV●L0M12Q6 MTZ2 16H1 Micrologic 5.0 X 1600 3200 (6) LC1F2100●● 1750
HD 1000 MTZ2 12H1 Micrologic 5.0 X 1250 2500 (6) LC1F1700●● 1450
ND 1400 – ATV●L0M14Q6 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
HD 1100 MTZ2 16H1 Micrologic 5.0 X 1600 3200 (6) LC1F1700●● 1450
ND 1600 – ATV●L0M16Q6 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2600●● 2600
HD 1300 MTZ2 16H1 Micrologic 5.0 X 1600 3200 (6) LC1F2100●● 1750
ND 1800 – ATV●L0M18Q6 (4) MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
HD 1400 ATV●L0M18Q6 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
ND 2200 – ATV●L0M22Q6 (4) MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
HD 1700 MTZ2 20H1 Micrologic 5.0 X 2000 4000 (6) LC1F2100●● 1750
ND 2600 – ATV●L0M26Q6 (4) MTZ2 32H1 Micrologic 5.0 X 3200 6400 (6) LC1F2600●● 2600
ATV6L0M26Q6 HD 2100 MTZ2 25H1 Micrologic 5.0 X 2500 5000 (6) LC1F2600●● 2600
(1) Replace the dot ● with “6” for ATV6A0 or “9” for ATV9A0.
(2) The type of circuit breaker is selected for Icu min. 50 kA.
(3) Replace the dots ●● with the control circuit voltage code indicated in the documentation for the contactor.
(4) A temperature rise test is required to fulfill IEC 61439-1.
(5) Rated instantaneous short-circuit current setting Ii: fixed
(6) Rated instantaneous short-circuit current setting Ii: 2

Variable speed drives: Configuration and runtime tools: Combinations: Dimensions:


page 30 page 28 page 80 page 20

109
Drives Field Services Variable speed drives
Altivar Process
A whole world of services for your drives by
Schneider Electric

Drives support and services offer by Schneider Electric


Variable speed drives are an important part of your operation, with downtime having
a significant impact on your business. Protecting that investment through
comprehensive drive services means that you can continue to deliver optimally
throughout the lifecycle of your drive. Our range of services is designed to help you
get more out of your drives, your operation, and to improve your environmental
impact.

What are my options?

Establish your services including maintenance policy, support, and training


Plan

How do I install and commission?

• Commissioning • Start up • Extended warranty


Install

2
1
How do I operate and maintain?
3 • Remote technical support • Preventive maintenance
Operate
Plant • Onsite expert assistance • Spare part management
Service Management
contract Lifecycle
4 How do I optimize?

• Training services • EcoStruxure Asset Advisor


Optimize
6 5

How do I extend and renew my solution?

• Drive revitalization • Drive replacement


Renew

How do we contribute to circular economy


Circular • Repair • Fast exchange by refurbished drive (1)
economy
• Spare parts • Take back and Recycling (1)

Install
b Extended Warranty service helps you control your maintenance costs.
Schneider Electric will provide a replacement drive or repair the drive on site
during a period of 1 or 3 years more than the standard warranty, in all conditions
covered by the extended warranty.

b S
 tart-up service is the first essential step in maintenance and optimal
operational performance of the drive. Our comprehensive review checks up to
100 parameters and is especially designed for drives in simple applications.

b C
 ommissioning service helps to ensure a reliable start for operations with more
complex applications and drive systems. The unique requirements of your
process need to be carefully considered to ensure efficient operations.

Operate
b Preventive Maintenance service performs predetermined maintenance actions
according to a drive product-specific schedule. The work is carried out by
certified technical experts following Schneider Electric instructions. This service
minimizes unplanned downtime and extends your equipment lifetime.

b R
 emote Technical Support brings you expert product assistance over phone,
email, chat, or Web for any technical questions relating to your drives, including
configuration, diagnostics, and maintenance. Our global support team is
multi-lingual with support available up to R&D level experts if needed.

b O
 n-Site Expert Assistance service offers you highly skilled field service experts
to troubleshoot and resolve drive equipment-related matters at your site, as a
back-up source of expertise for your personnel.

b S
 pare Part Management service identifies and manages your critical spare
parts either on your site or offsite. This service ensures that you have access to
the spares you need without you having to invest in capital to maintain the stock.

(1) Services available in countries that have the right structure and capabilities.

110
Drives Field Services Variable speed drives
(continued) Altivar Process
A whole world of services for your drives by
Schneider Electric

Drives support and services offer by Schneider Electric (continued)


Optimize
b Training service offers eLearning, classroom, and onsite training provision to
enhance the technical installation, commissioning, and maintenance
competencies of your personnel. Added competence translates into further
process efficiency and reliability, as well as employee satisfaction.

b E
 coStruxure Asset Advisor service enables you to move from reactive to
predictive maintenance and access actionable insight provided by the advisor.
The service predicts drive- and motor-related actions through connected devices
and advanced algorithms monitored by Schneider Electric’s experts.

Renew
b Drive Revitalization is an excellent choice if you prefer to use your aging drives
longer and want to extend their service life with affordable and comprehensive
inspection and replacement of all critical parts.

b D
 rive Replacement involves modernizing equipment by replacing the previous
aged or obsolete drive with a new one matched to the purpose. The service can
be extended with engineering in case the device and process requires more
advanced engineering.

Circular economy with drives


b Spare Parts are available from our local, regional, and global stocks. Original
equipment parts from Schneider Electric are reliable and easily available. They
will help to keep your drive in operation for longer.

b R
 epair allows you to extend the life of your drive. The affected drive can be
replaced, or repaired on site or at our repair centers, depending on the type of
drive in question.

b F
 ast exchange by refurbished drive (1) gives a second life to inoperative
drives. In this case, we offer an immediate exchange with a replacement
refurbished drive and take back the product, repair it, and keep it ready for the
next exchange..

b T
 ake-back and recycling (1) is the last step to improve your environmental
impact. Unrepairable products are dismantled, and raw materials are collected
and given a second life. Up to 85% of the product components can be recycled.

Service contracts secure recovery, availability and outcome


Service contracts manage the safety and performance of your assets through
well-defined maintenance plans tailored to your operational needs. The predefined
service contract – Advantage Service Plan – and fully customizable “à la carte”
service contract are built from services in the “Operate” and “Optimize” phases and
service levels defining availability, response, and lead times matching your
particular needs. You will enjoy priority access to Schneider Electric support when
you need it, as well as having an expert partner to plan the long-term evolution of
your drives.

mySchneider app
With the mySchneider app you have easy 24/7 access to product information and
expert support. All registered users have access to additional features, such as
real-time notifications, order tracking, product pricing, and availability. The
mySchneider app is available for download from the IOS and Android app store.

Schneider Electric – helping you succeed


Schneider Electric, the leader in digital transformation of energy management and
automation, has operations in more than 100 countries. With this global footprint we
have certified drives field service representatives, regional expert and advanced
level support up to product R&D to provide you the right support across the lifecycle
of your drives. Furthermore, we offer an extensive network of local and global repair
centers and a logistics chain that underpins our ability to respond to your needs.

To order services or find out more, please contact your local Schneider Electric
service center.

(1) Services available in countries that have the right structure and capabilities.

111
Index Variable speed drives
Altivar Process Modular
Product reference index

A ATV6A0C25Q6 45 ATV6B0C16T6 55 ATV6L0C20Q6 69 ATV6L0M18T6 67


APM1A0C16N4RH 20 ATV6A0C25R4 37 ATV6B0C20N6 53 ATV6L0C20R4 61 ATV6L0M22N6 65
APM1A0C16N401 20 ATV6A0C25T4 39 ATV6B0C20Q4 47 ATV6L0C20T4 63 ATV6L0M22Q6 69
APM1A0C20Y6 20 ATV6A0C25T6 43 ATV6B0C20Q6 57 ATV6L0C20T6 67 ATV6L0M22T6 67
APM1A0C20Y6RH 20 ATV6A0C31N6 41 ATV6B0C20R4 49 ATV6L0C25Q4 59 ATV6L0M26N6 65
APM1B0C16N4 20 ATV6A0C31Q4 35 ATV6B0C20T4 51 ATV6L0C25R4 61 ATV6L0M26Q6 69
APM1B0C20Y6 20 ATV6A0C31Q6 45 ATV6B0C20T6 55 ATV6L0C25T4 63 ATV6L0M26T6 67
APM1L0C20N4 20 ATV6A0C31R4 37 ATV6B0C25N6 53 ATV6L0C28N6 65 ATV9A0C11N6 42
APM1L0C28Y6 20 ATV6A0C31T4 39 ATV6B0C25Q4 47 ATV6L0C28Q6 69 ATV9A0C11Q4 36
APM1L0C31N4 20 ATV6A0C31T6 43 ATV6B0C25Q6 57 ATV6L0C28T6 67 ATV9A0C11Q6 46
APM1L0C45Y6 20 ATV6A0C35Q4 35 ATV6B0C25R4 49 ATV6L0C31N6 65 ATV9A0C11R4 38
APM1L0CCM115 27 ATV6A0C35R4 37 ATV6B0C25T4 51 ATV6L0C31Q4 59 ATV9A0C11T4 40
APM1L0CCM230 27 ATV6A0C35T4 39 ATV6B0C25T6 55 ATV6L0C31Q6 69 ATV9A0C11T6 44
APM1L0LCMN4 27 ATV6A0C40N6 41 ATV6B0C31N6 53 ATV6L0C31R4 61 ATV9A0C13N6 42
APM1L0LCMY6 27 ATV6A0C40Q4 35 ATV6B0C31Q4 47 ATV6L0C31T4 63 ATV9A0C13Q4 36
APM1L0LFMN4 26 ATV6A0C40Q6 45 ATV6B0C31Q6 57 ATV6L0C31T6 67 ATV9A0C13Q6 46
APM1L0LFMY6 26 ATV6A0C40R4 37 ATV6B0C31R4 49 ATV6L0C40N6 65 ATV9A0C13R4 38
APM1L0LPMN4 26 ATV6A0C40T4 39 ATV6B0C31T4 51 ATV6L0C40Q4 59 ATV9A0C13T4 40
APM1L0LPMY6 26 ATV6A0C40T6 43 ATV6B0C31T6 55 ATV6L0C40Q6 69 ATV9A0C13T6 44
APM1L0MPMN4 27 ATV6A0C45Q4 35 ATV6B0C35Q4 47 ATV6L0C40R4 61 ATV9A0C16N6 42
APM1L0MPMY6 27 ATV6A0C45R4 37 ATV6B0C35R4 49 ATV6L0C40T4 63 ATV9A0C16Q4 36
APM6A0CTLN401 22 ATV6A0C45T4 39 ATV6B0C35T4 51 ATV6L0C40T6 67 ATV9A0C16Q6 46
APM6A0CTLY6 22 ATV6A0C50N6 41 ATV6B0C40N6 53 ATV6L0C45N6 65 ATV9A0C16R4 38
APM6B0CTLN4 22 ATV6A0C50Q4 35 ATV6B0C40Q4 47 ATV6L0C45Q6 69 ATV9A0C16T4 40
APM6B0CTLY6 22 ATV6A0C50Q6 45 ATV6B0C40Q6 57 ATV6L0C45T6 67 ATV9A0C16T6 44
APM6L0CTLN4 22 ATV6A0C50R4 37 ATV6B0C40R4 49 ATV6L0C50Q4 59 ATV9A0C20N6 42
APM6L0CTLY6 22 ATV6A0C50T4 39 ATV6B0C40T4 51 ATV6L0C50R4 61 ATV9A0C20Q4 36
APM9A0CTLN401 22 ATV6A0C50T6 43 ATV6B0C40T6 55 ATV6L0C50T4 63 ATV9A0C20Q6 46
APM9A0CTLY6 22 ATV6A0C56Q4 35 ATV6B0C45Q4 47 ATV6L0C56N6 65 ATV9A0C20R4 38
APM9B0CTLN4 22 ATV6A0C56R4 37 ATV6B0C45R4 49 ATV6L0C56Q6 69 ATV9A0C20T4 40
APM9B0CTLY6 22 ATV6A0C56T4 39 ATV6B0C45T4 51 ATV6L0C56T6 67 ATV9A0C20T6 44
APM9L0CTLN4 22 ATV6A0C63N6 41 ATV6B0C50N6 53 ATV6L0C63Q4 59 ATV9A0C25N6 42
APM9L0CTLY6 22 ATV6A0C63Q4 35 ATV6B0C50Q4 47 ATV6L0C63R4 61 ATV9A0C25Q4 36
APMBC0C50N4 27 ATV6A0C63Q6 45 ATV6B0C50Q6 57 ATV6L0C63T4 63 ATV9A0C25Q6 46
APMBC0C63Y6 27 ATV6A0C63R4 37 ATV6B0C50R4 49 ATV6L0C71N6 65 ATV9A0C25R4 38
APMBC0CTLN4 27 ATV6A0C63T4 39 ATV6B0C50T4 51 ATV6L0C71Q6 69 ATV9A0C25T4 40
APMBC0CTLY6 27 ATV6A0C63T6 43 ATV6B0C50T6 55 ATV6L0C71T6 67 ATV9A0C25T6 44
APMCA01LCN4RH 21 ATV6A0C71Q4 35 ATV6B0C56Q4 47 ATV6L0C80Q4 59 ATV9A0C31N6 42
APMCA01LCY6RH 21 ATV6A0C71R4 37 ATV6B0C56R4 49 ATV6L0C80R4 61 ATV9A0C31Q4 36
APMCA02LCN4RH 21 ATV6A0C71T4 39 ATV6B0C56T4 51 ATV6L0C80T4 63 ATV9A0C31Q6 46
APMCA02LCY6RH 21 ATV6A0C80N6 41 ATV6B0C63N6 53 ATV6L0C90N6 65 ATV9A0C31R4 38
APMCA03LCN4RH 21 ATV6A0C80Q4 35 ATV6B0C63Q4 47 ATV6L0C90Q4 59 ATV9A0C31T4 40
APMCA03LCY6RH 21 ATV6A0C80Q6 45 ATV6B0C63Q6 57 ATV6L0C90Q6 69 ATV9A0C31T6 44
ATV6A0C11N6 41 ATV6A0C80R4 37 ATV6B0C63R4 49 ATV6L0C90R4 61 ATV9A0C35Q4 36
ATV6A0C11Q4 35 ATV6A0C80T4 39 ATV6B0C63T4 51 ATV6L0C90T4 63 ATV9A0C35R4 38
ATV6A0C11Q6 45 ATV6A0C80T6 43 ATV6B0C63T6 55 ATV6L0C90T6 67 ATV9A0C35T4 40
ATV6A0C11R4 37 ATV6A0M10N6 41 ATV6B0C71Q4 47 ATV6L0M10Q4 59 ATV9A0C40N6 42
ATV6A0C11T4 39 ATV6A0M10Q6 45 ATV6B0C71R4 49 ATV6L0M10R4 61 ATV9A0C40Q4 36
ATV6A0C11T6 43 ATV6A0M10T6 43 ATV6B0C71T4 51 ATV6L0M10T4 63 ATV9A0C40Q6 46
ATV6A0C13N6 41 ATV6A0M12N6 41 ATV6B0C80N6 53 ATV6L0M12N6 65 ATV9A0C40R4 38
ATV6A0C13Q4 35 ATV6A0M12Q6 45 ATV6B0C80Q4 47 ATV6L0M12Q4 59 ATV9A0C40T4 40
ATV6A0C13Q6 45 ATV6A0M12T6 43 ATV6B0C80Q6 57 ATV6L0M12Q6 69 ATV9A0C40T6 44
ATV6A0C13R4 37 ATV6B0C11N6 53 ATV6B0C80R4 49 ATV6L0M12R4 61 ATV9A0C45Q4 36
ATV6A0C13T4 39 ATV6B0C11Q4 47 ATV6B0C80T4 51 ATV6L0M12T4 63 ATV9A0C45R4 38
ATV6A0C13T6 43 ATV6B0C11Q6 57 ATV6B0C80T6 55 ATV6L0M12T6 67 ATV9A0C45T4 40
ATV6A0C16N6 41 ATV6B0C11R4 49 ATV6B0M10N6 53 ATV6L0M14N6 65 ATV9A0C50N6 42
ATV6A0C16Q4 35 ATV6B0C11T4 51 ATV6B0M10Q6 57 ATV6L0M14Q6 69 ATV9A0C50Q4 36
ATV6A0C16Q6 45 ATV6B0C11T6 55 ATV6B0M10T6 55 ATV6L0M14T6 67 ATV9A0C50Q6 46
ATV6A0C16R4 37 ATV6B0C13N6 53 ATV6B0M12N6 53 ATV6L0M15Q4 59 ATV9A0C50R4 38
ATV6A0C16T4 39 ATV6B0C13Q4 47 ATV6B0M12Q6 57 ATV6L0M15R4 61 ATV9A0C50T4 40
ATV6A0C16T6 43 ATV6B0C13Q6 57 ATV6B0M12T6 55 ATV6L0M15T4 63 ATV9A0C50T6 44
ATV6A0C20N6 41 ATV6B0C13R4 49 ATV6L0C13Q4 59 ATV6L0M16N6 65 ATV9A0C56Q4 36
ATV6A0C20Q4 35 ATV6B0C13T4 51 ATV6L0C13R4 61 ATV6L0M16Q6 69 ATV9A0C56R4 38
ATV6A0C20Q6 45 ATV6B0C13T6 55 ATV6L0C13T4 63 ATV6L0M16T6 67 ATV9A0C56T4 40
ATV6A0C20R4 37 ATV6B0C16N6 53 ATV6L0C16Q4 59 ATV6L0M18N6 65 ATV9A0C63N6 42
ATV6A0C20T4 39 ATV6B0C16Q4 47 ATV6L0C16R4 61 ATV6L0M18Q4 59 ATV9A0C63Q4 36
ATV6A0C20T6 43 ATV6B0C16Q6 57 ATV6L0C16T4 63 ATV6L0M18Q6 69 ATV9A0C63Q6 46
ATV6A0C25N6 41 ATV6B0C16R4 49 ATV6L0C20N6 65 ATV6L0M18R4 61 ATV9A0C63R4 38
ATV6A0C25Q4 35 ATV6B0C16T4 51 ATV6L0C20Q4 59 ATV6L0M18T4 63 ATV9A0C63T4 40

112
Index (continued) Variable speed drives
Altivar Process Modular
Product reference index

ATV9A0C63T6 44 ATV9B0C50T6 56 ATV9L0C71T6 68 MODBUOC63T4APM 75 VW3A99ACFAA 25


ATV9A0C71Q4 36 ATV9B0C56Q4 48 ATV9L0C80Q4 60 76 VW3A99ACFAA01 25
ATV9A0C71R4 38 ATV9B0C56R4 50 ATV9L0C80R4 62 MODBUOC63T6APM 78 VW3A99ACFABM 25
ATV9A0C71T4 40 ATV9B0C56T4 52 ATV9L0C80T4 64 MODBUOC80N6APM 77 VW3A99ACFCB 25
ATV9A0C80N6 42 ATV9B0C63N6 54 ATV9L0C90N6 66 MODBUOC80Q4APM 71 VW3A99ACFCB01 25
72
ATV9A0C80Q4 36 ATV9B0C63Q4 48 ATV9L0C90Q4 60 VW3A99ACFCBM01 25
MODBUOC80Q6APM 79
ATV9A0C80Q6 46 ATV9B0C63Q6 58 ATV9L0C90Q6 70 VW3A99ACFCBM02 25
MODBUOC80R4APM 73
ATV9A0C80R4 38 ATV9B0C63R4 50 ATV9L0C90R4 62 74 VW3A99ACFCBN01 25
ATV9A0C80T4 40 ATV9B0C63T4 52 ATV9L0C90T4 64 MODBUOC80T4APM 75 VW3A99ACFEBN01 25
ATV9A0C80T6 44 ATV9B0C63T6 56 ATV9L0C90T6 68 76 VW3A99ACFEBN02 25
ATV9A0M10N6 42 ATV9B0C71Q4 48 ATV9L0M10Q4 60 MODBUOC80T6APM 78 VW3A99ACFEC 25
ATV9A0M10Q6 46 ATV9B0C71R4 50 ATV9L0M10R4 62 MODBUOM10N6APM 77 VW3A99ACFEC01 25
ATV9A0M10T6 44 ATV9B0C71T4 52 ATV9L0M10T4 64 MODBUOM10Q6APM 79 VW3A99AR01 25
ATV9A0M12N6 42 ATV9B0C80N6 54 ATV9L0M12N6 66 MODBUOM10T6APM 78 VW3A99BCA02 26
ATV9A0M12Q6 46 ATV9B0C80Q4 48 ATV9L0M12Q4 60 MODBUOM12N6APM 77 VW3A99BCA03 25
ATV9A0M12T6 44 ATV9B0C80Q6 58 ATV9L0M12Q6 70 MODBUOM12Q6APM 79 VW3A99BCFAB 25
ATV9B0C11N6 54 ATV9B0C80R4 50 ATV9L0M12R4 62 MODBUOM12T6APM 78 VW3A99BCFAB01 25
ATV9B0C11Q4 48 ATV9B0C80T4 52 ATV9L0M12T4 64 VW3A99BCFCD 25
T
ATV9B0C11Q6 58 ATV9B0C80T6 56 ATV9L0M12T6 68 VW3A99BCFCD01 25
TCSEGWB131W 29
ATV9B0C11R4 50 ATV9B0M10N6 54 ATV9L0M14N6 66 VW3A99BR01 25
ATV9B0C11T4 52 ATV9B0M10Q6 58 ATV9L0M14Q6 70 V VW3A99LR01 26
ATV9B0C11T6 56 ATV9B0M10T6 56 ATV9L0M14T6 68 VW3A83BMR015 23 VW3A1104R10 29
ATV9B0C13N6 54 ATV9B0M12N6 54 ATV9L0M15Q4 60 VW3A83BMR050 23 VW3A1104R30 29
ATV9B0C13Q4 48 ATV9B0M12Q6 58 ATV9L0M15R4 62 VW3A83BMR100 26 VW3A1104R50 29
ATV9B0C13Q6 58 ATV9B0M12T6 56 ATV9L0M15T4 64 VW3A83CDG020 23 VW3A1104R100 29
ATV9B0C13R4 50 ATV9L0C13Q4 60 ATV9L0M16N6 66 VW3A83CDG030 23 VW3A1111 29
ATV9B0C13T4 52 ATV9L0C13R4 62 ATV9L0M16Q6 70 VW3A83CDG050 23 VW3A1112 29
ATV9B0C13T6 56 ATV9L0C13T4 64 ATV9L0M16T6 68 VW3A83CDG100 23 VW3A1115 29
ATV9B0C16N6 54 ATV9L0C16Q4 60 ATV9L0M18N6 66 VW3A97A01 23 VX5VAM001 28
ATV9B0C16Q4 48 ATV9L0C16R4 62 ATV9L0M18Q4 60 VW3A97B01 23 VX5VAML001 28
ATV9B0C16Q6 58 ATV9L0C16T4 64 ATV9L0M18Q6 70 VW3A98ABMAAA 24 VX5VAML002 28
ATV9B0C16R4 50 ATV9L0C20N6 66 ATV9L0M18R4 62 VW3A98ABMCAB 24 VX5VAML003 28
ATV9B0C16T4 52 ATV9L0C20Q4 60 ATV9L0M18T4 64 VW3A98ABMCAC 24
Z
ATV9B0C16T6 56 ATV9L0C20Q6 70 ATV9L0M18T6 68 VW3A98ABMDCE 24
ZB5AZ905 29
ATV9B0C20N6 54 ATV9L0C20R4 62 ATV9L0M22N6 66 VW3A98ABMDCF 24
ATV9B0C20Q4 48 ATV9L0C20T4 64 ATV9L0M22Q6 70 VW3A98ABPC1 24
ATV9B0C20Q6 58 ATV9L0C20T6 68 ATV9L0M22T6 68 VW3A98ABPDCE1 24
ATV9B0C20R4 50 ATV9L0C25Q4 60 ATV9L0M26N6 66 VW3A98ABPDCF 24
ATV9B0C20T4 52 ATV9L0C25R4 62 ATV9L0M26Q6 70 VW3A98BBMAAB 24
ATV9B0C20T6 56 ATV9L0C25T4 64 ATV9L0M26T6 68 VW3A98BBMCAD 24
ATV9B0C25N6 54 ATV9L0C28N6 66 VW3A98BBMDCG 24
M
ATV9B0C25Q4 48 ATV9L0C28Q6 70 VW3A98BBPC 24
MODBUOC16Q4APM 71
ATV9B0C25Q6 58 ATV9L0C28T6 68 72 VW3A98BBPDCG 24
ATV9B0C25R4 50 ATV9L0C31N6 66 MODBUOC16R4APM 73 VW3A98BBPDCK 24
ATV9B0C25T4 52 ATV9L0C31Q4 60 74 VW3A98CF3169 24
ATV9B0C25T6 56 ATV9L0C31Q6 70 MODBUOC16T4APM 75 VW3A98CF4040 24
ATV9B0C31N6 54 ATV9L0C31R4 62 76 VW3A98CTM01 24
ATV9B0C31Q4 ATV9L0C31T4 MODBUOC20N6APM 77
48 64 VW3A98CTM02 24
79
ATV9B0C31Q6 58 ATV9L0C31T6 68 VW3A98CTM03 25
MODBUOC20Q6APM 79
ATV9B0C31R4 50 ATV9L0C40N6 66 VW3A98CTM04 25
MODBUOC20T6APM 78
ATV9B0C31T4 52 ATV9L0C40Q4 60 VW3A98LBPC1 26
MODBUOC31Q4APM 71
ATV9B0C31T6 56 ATV9L0C40Q6 70 72 VW3A98LBPC2 26
ATV9B0C35Q4 48 ATV9L0C40R4 62 MODBUOC31R4APM 73 VW3A98LBPC3 26
ATV9B0C35R4 50 ATV9L0C40T4 64 74 VW3A98LGHC1 26
ATV9B0C35T4 52 ATV9L0C40T6 68 MODBUOC31T4APM 75 VW3A98LGHC2 26
76
ATV9B0C40N6 54 ATV9L0C45N6 66 VW3A98LTMC1 26
MODBUOC40N6APM 77
ATV9B0C40Q4 48 ATV9L0C45Q6 70 VW3A99ACA01 26
MODBUOC40Q6APM 79
ATV9B0C40Q6 58 ATV9L0C45T6 68 VW3A99ACA02 26
MODBUOC40T6APM 78
ATV9B0C40R4 50 ATV9L0C50Q4 60 VW3A99ACA03 25
MODBUOC50Q4APM 71
ATV9B0C40T4 52 ATV9L0C50R4 62 72 VW3A99ACA04 25
ATV9B0C40T6 56 ATV9L0C50T4 64 MODBUOC50R4APM 73 VW3A99ACA05 26
ATV9B0C45Q4 48 ATV9L0C56N6 66 74 VW3A99ACA06 26
ATV9B0C45R4 50 ATV9L0C56Q6 70 MODBUOC50T4APM 75 VW3A99ACA07 26
ATV9B0C45T4 52 ATV9L0C56T6 68 76 VW3A99ACA08 26
ATV9B0C50N6 54 ATV9L0C63Q4 60 MODBUOC63N6APM 77 VW3A99ACA09 26
ATV9B0C50Q4 48 ATV9L0C63R4 62 MODBUOC63Q4APM 71 VW3A99ACA10 26
72
ATV9B0C50Q6 58 ATV9L0C63T4 64 VW3A99ACA11 25
MODBUOC63Q6APM 79
ATV9B0C50R4 50 ATV9L0C71N6 66 VW3A99ACA12 25
MODBUOC63R4APM 73
ATV9B0C50T4 52 ATV9L0C71Q6 70 74 VW3A99ACA13 25

113
Learn more about our products at
www.se.com/drives

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the
products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability
of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk
analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric
nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Design: Schneider Electric


Photos: Schneider Electric

Schneider Electric Industries SAS


Head Office
35, rue Joseph Monier - CS 30323
F-92500 Rueil-Malmaison Cedex
France

DIA2ED2180301EN
June 2021 - V7.0