Dorot Hidr.300
Dorot Hidr.300
Dorot Hidr.300
WATERWORKS
Dorot’s valves are specially designed to comply with all
the demands of Waterworks systems such as: Pressure
management, Low flow regulation, Leakage prevention,
Pump control, Level control, Surge prevention, Sewage
and Water treatment.
IRRIGATION
Dorot is a leader in Automatic Control valves for
irrigation applications: Drip Irrigation, Greenhouses,
Turf and Landscaping. The innovative state of the art
products are made of a variety of materials such as:
Cast Iron, Ductile Iron, Steel, Stainless Steel, Bronze,
Polyamide and uPVC.
FIRE PROTECTION
Dorot offers a variety of valves for fire protection
applications with UL Approvals.
CONTENTS
GENERAL INFORMATION 4
Overview 4
Features 4
ENGINEERING DATA 5
Technical Specifications 5
Materials 5
Basic Valve Operating Modes 6
Typical Pressure Reducing Performance Chart 10
Cavitation Data 11
Dimensions & Weights - Models 30/31 12
Headloss Charts - Models 30/31 13
Dimensions & Weights - Model 32 14
Headloss Chart - Model 32 15
Components 16
WATERWORKS CONTROL APPLICATION 17
Electronic and Remote control 17
Pressure Regulating 17
Rate of Flow Regulating 17
Water Level Control 18
Pumping Systems Control and Water Hammer / Surge Protection 19
FIRE FIGHTING APPLICATIONS 20
PILOTS AND ACCESSORIES 21
OTHER DOROT PRODUCTS 23
Series 300 Valves
GENERAL INFORMATION
Overview
DOROT’S 300 Series, the latest line of state-of-the-art globe type automatic control valves, is designed to withstand even
the most demanding requirements of water system control. The experts at DOROT developed this technically-advanced
line with capabilities, far beyond any other valve on the market.
This Engineering Data guide will asist the reader in the selection of the optimal DOROT Series 300 valve.
Features
Air release nut
Position indicator (optional)
Diaphragm discs
Double Chamber disc (optional)
Fully guided stem
Rubber seal
Seal discs
Seat
Stainless Steel internal parts
Centering guide
4
Series 300 Valves
ENGINEERING DATA
Technical Specifications
Parameter Standard Optional
Connections
• Flanged ISO 7005 or ANSI B16 • Flanged AS10, JIS B22, ABNT and others
• Threaded BSP or NPT
• Model 30: 0.5 – 16bar
• 0 min. press. with N.O spring assisted opening.
7 – 230 psi
• 0.2 bar / 3 psi min. pressure without a spring
Pressure range
• Models 31, 32: 0.5-25 bar
Note: both options require usage of external higher
7 – 360 psi
closing pressure
Materials
Part Standard Optional
Main Valve Internals SST, Bronze and Coated Steel SST 316, HASTELLOY, SMO, DUPLEX
EPDM
Seals NBR (Buna-N)
Viton
SST 304
Control Trim: Fittings and control devices Brass
SST 316
Copper
Control Trim: Tubes Reinforced, heavy-duty Nylon, Polypropylene
SST 316
5
Series 300 Valves
ENGINEERING DATA
Closed Mode
D chamber - Closed Mode
Open Mode: The control device releases the pressure
from the top control chamber.
D chamber - Closed Mode
The seal assembly is forced to the “open” position by
Open Mode the pipeline pressure, allowing flow through the valve.
Control
Opened Mode Device
Control
Open Mode
Device
6
C M Y CM MY CY CMY K
C M Y CM MY CY CMY K
ENGINEERING DATA
Modulating Mode
Modulating Mode
General
Modulating Mode
GeneralModulating
Positioning Mode
the seal a short distance (less than 1/4 of the Regulation at high pressures
seat diameter) from the seat, creates friction and turbulence,
Positioning the seal a short distance (less than 1/4 of the difference
General
causingGeneral
energy loss in the fluid passing through the valve.
seat diameter) from the seat, creates friction and turbulence,
The results are:
Positioning the loss
seal in a shortfluid distance (less than 1/4 of the The S-300 has exceptional resistance to damages,
causingPositioning
energy sealthe
the the aand
short passing
distance (lessthrough
than ofthe valve.caused by cavitation conditions. This feature was
1/4 turbulence,
-Reduction
seat diameter)of pressure
from seat, flow
createsrate.friction and
The results
the are:
seat diameter)
-Increase
causing
-Reduction
of
energy
of
inletloss
pressure infrom
pressure. the the seat,
andfluid
flow
creates friction
passing
rate. through andthe valve.certified by extensive tests, carried by an independent
The turbulence,
position
results causing energy loss in the fluid passing
of the seal assembly is dictated by the volume laboratories in US and Europe.
-Increase ofare:
through inlet
thethepressure.
valve.
of control
-Reduction fluid
of in topThe results
control are:
chamber which is determinedThe operation limits, as found in these tests, can be
The position
- ofpressure
Reduction the of seal
pressure
and flow
assembly
and flow
rate.
is dictated by the volume
rate.
by the control
-Increase of device.
inlet pressure. calculated for any specific location- using a simple
of control fluid in of
- Increase the top
inlet control chamber which is determinedcomputer program (supplied on request).
pressure.
The control
position device
of the is
sealoperated
assembly by hand
is (manual
dictated by control),
the volumeby
by the control device.
The position of the seal assembly is dictated by the
electric
of control current
fluid (solenoid
in the valve), or by which
hydraulic pressure For operation conditions that exceed the safe limit- a
The control
volumedevice istop
of control
control
operated chamber
by hand (manual
fluid in the top
is control),
determined by
(pilot
by thevalves,
control hydraulic
device. relays). Allcontrol
can be chamber, which
used in standard special Cavitation-Free valve can be supplied. This
electriciscurrent
determined (solenoid valve),
by the control or by hydraulic pressure version, marked by the suffix “F” (example 30F-3 is a
device.
(single
The chamber) valves as well as bybyin double chamber valves.
(pilotcontrol
valves, device
hydraulic
The control
is operated
device isrelays).
operatedAll
hand
can
handbe
(manual control),
usedcontrol),
(manual in standardby
cavitation-free, 80mm / 3” valve), can operate at any
electric current
(single chamber) (solenoid
valves(solenoid
by electric current valve),
as wellvalve), or by
as in double hydraulic pressure
chamber valves. pressure differential without being ruined by it.
or by hydraulic
(pilot valves, hydraulic relays). All can be used
pressure (pilot valves, hydraulic relays). All can be used in standard
Modulating
(single chamber) mode
in standard valves
in standard
as well as
(single chamber)
(single
in double
valves
chamber)
as well aschamber valves. The internal structure includes a Stainless Steel,
in doublevalves. perforated cylinder, that is connected below the standard
chamber
Modulating valves.in standard (single chamber) valves. seal disc and moving freely inside the seat.
mode
Modulating
Modulating mode mode in standard (single chamber) valves. The valve is assembled to generate “over the seat” flow,
in standard
(single chamber) valves so the water stream enters the cylinder from its external
side and emerges through the internal side. The energy
is dissipated by the high-velocity, turbulent flow through
the exposed holes above the seat (due to varying trim
position).
The pressure recovery, that is the cause of cavitation
damage, happens now inside the cylinder and not
adjacent to the body wall. As the SST material is highly-
resistant to cavitation- it is not damaged.
Closed
Closed
Closed
Closed
Closed Valve
Fully Open
FullyOpen
Fully Open
Fully Open
Cavitation energy
dissipation area
Fully-opened
Regulating
Regulating Valve
Regulating
Regulating
7
Series 300 Valves
ENGINEERING DATA
2-Way Control Device Regulating Mode: The pilot is set to the required
downstream pressure. The pilot senses when the
The 2-way control device is assembled on a control downstream pressure reaches the required value
circuit, connecting upstream to downstream through the causing passage (b) to equal passage (a) b=a. Now,
control chamber. water that flows through the control loop passes from (a)
There are two restrictors assembled in this circuit: through (b) and into the downstream. The control media
(a) A nozzle or a needle valve, at a fixed opening. in the upper part of the control chamber is now steady,
(b) A modulating device (pilot), whose passage may vary keeping the diaphragm and seal in a fixed position. Any
from complete closure (b=o) to a fully open size change in the downstream pressure will change the
(when b>a). b=a balance. This change adds or drains water from the
The volume of the control media in the chamber is control chamber, thus opening or closing the main valve
determined by the relative passages (a) and (b), or, in until it reaches the balanced regulating position b=a
fact, by the opening of (b), as (a) is fixed. once again.
Regulating Valve
Regulating Valve
The 2-way control device provides sensitive, accurate,
and constant modulating, control of the main valve. The
main valve does not fully open, as the control device
Closed Valve prevents total draining of the control chamber.
The 2-way control device is standard in most pressure
Closed Mode
Open Mode: Pilot (b) senses a downstream pressure regulating valves.
lower than the set-point, and fully opens passage (b),
larger than (a). All the water from the upstream flows
through (a) and (b), directly to the downstream, allowing
water from the upper part of the control chamber to
partially drain until the pressure in the chamber equals
the downstream pressure.
Pressure in the upper part of the control chamber is
decreased and the upstream water pressure forces the
seal disc to rise Closed
(opening
Mode
the valve).
Open Mode
Opened Valve
Open Mode
8
.G3-d 3/3/02 11:50 Page 1
C M Y CM MY CY CMY K
Series 300 Valves
ENGINEERING DATA
3-Way
3-Way Control
Control Device
Device Proportional
Proportional Pressure
Pressure Reducer
Reducer
The3-way
The 3-waycontrol
control device
device is
is aa small
smallselector
selectorvalve
valvewhich:
which: Theproportional
The proportionalpressure
pressurereducer
reducerisis a valve
a valve that
that has a control
1. Permits passage of the control media into the has a control chamber permanently connected to the
1.Permits passage of the control media into the main valve chamber permanently connected to the downstream.
main valve control chamber (initiating the “closing” downstream.
control chamber (initiating the "closing" procedure),
procedure), or
This valve must be a double chamber [D] type.
This valve must be a double chamber [D] type.
or2. Permits drainage of the control media from the control The
The balance of
balance of hydraulic forces created
hydraulic forces createdbetween
between the high
2. Permits
chamber drainage of the control
to the atmosphere mediathe
(initiating from the control
“opening” pressure on the small seal area, and the lower
the high pressure on the small seal area, and the downstream
chamber to the
procedure). atmosphere (initiating the "opening" procedure). pressure on the larger diaphragm area, causes
lower downstream pressure on the larger diaphragm a fixed ratio
Some of the 3-way control devices have a third mode as ofarea,
inlet/outlet
causes apressure of of
fixed ratio approximately 3:1. of
inlet/outlet pressure
Some of the 3-way control devices have a third mode as
well, which prevents inflow or outflow from the control approximately 3:1.
well,
chamber, soprevents
which inflow
that the main or outflow
valve remains from the control
fixed when the No
Noother
other control device isis needed.
control device needed.
chamber,
device is so thatmode.
in this the main valve remains fixed when the
device is in this
The 3-way modemode.
is used in on-off valves or when the
This mode is
regulating usedis in
valve on-off
fully open,valves or when
in order thespecific
to obtain regulating
Separation
valve is fully
operating open, inOnce
conditions. orderintoposition,
obtain there
specific
is nooperating
water Disc
flow through
conditions. Oncethe in
control chamber.
position, there is no water flow through
The
the 3-waychamber.
control control circuit may open the main valve
entirely, creating minimum head loss.
The 3-way control device may open the main valve entirely,
The 3-way control device must be used when external
creating minimum head loss.
media (not pipeline water) is used to control the valve,
The 3-way
or when thecontrol device
control mediamust be used
is dirty when external media
or abrasive.
(not pipeline water) is used to control the valve, or when
the control media is abrasive.
Closed Valve
Opened Valve
Open Mode
Regular Flow
Open Mode
Open Valve
9
Series 300 Valves
ENGINEERING DATA
70 8
7
60
6
Metres
50
Flow Litre/sec
Pressure Metres
Flow Litre/sec
5
40
Pressure
30
3
20
2
10 1
0 0
9.2.2001 10.2.2001 11.2.2001 12.2.2001 13.2.2001 14.2.2001 15.2.2001 16.2.2001
Inlet
Inlet Pressure
Pressure Outlet
Outlet Pressure
Pressure Flow
Flow
Comparison of different
SERIES 300 seal structures
CHARACTERISTIC CURVE
% COMPARISON WITH COMPETITIVE DESIGNS
100
90
80
70
60
Valve opening
50
40
30
20
10
Unstable
Unstable regulation zone
regulation zone
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.6 0.7 0.8 1.0
Kn
Kv
LTPDesign
LTP Design (S-300
(S-300 Valve) *
Valve)* V-Plug
V-Plug U-Plug
U-Plug LTP Design
Flat-Disk plug (S-300 Valve)
** Independent
Independentlaboratory report
laboratory data
report source
data source
10
Series 300 Valves
ENGINEERING DATA
Cavitation Data
Inlet
Inlet pressure
pressure
psi mwc
360 250
240
340
230
320 220
210
300
200 Noisy
Noisy
280 190 Destructive
Destructive Operating
Operating
Cavitation
Cavitation
260 180
170
240
160
Case II
Case- 2
220 150
140
200 Case-1I
Case
130
180
120
160 110
CaseIII
Case- 3
100
140
90
120 80
100
70 Safe
Safe
60 Operating
Operating
80
50
Conditions
conditions
60 40
30
40
20
20 10 Outlet
Outlet
0 pressure
pressure
10 20 30 40 50 60 70 80 mwc
10 20 30 40 50 60 70 80 90 100 110 psi
Cavitation Chart
Limits of operating conditions
The chart above sets the safe limits for valves that are supposed to operate at a considerable pressure differential.
Such conditions generate noise and possible cavitation damages to the valve body.
How to use the chart:
i. Determine the maximal dynamic pressure that may be applied in the inlet of the valve.
ii. Draw an horizontal line from the pressure scale at the left side of the chart
iii. Find the requested outlet pressure in the pressure scale at the bottom of the chart.
iv. Draw an upward line at this point.
v. The intersection of the two lines defines the cavitation characteristics of the valve operation.
- In the case that it falls in the RED zone (case I)- the valve may be damaged in a fairly short time.
- In the case that it falls in the YELLOW zone (case II)- the valve may generate a noise that exceeds 80db.
- In the case that the intersection is within the GREEN zone (case III)- the valve will perform safely and quietly
General remark: The cavitation and noise data are based on tests done by the Utah State University, US, and Delft Hydraulic Laboratories, Holland.
11
Series 300 Valves
ENGINEERING DATA
Head Loss Factor K (dimensionless) 1.3 2.8 3.3 4.3 4.3 4.2 3.6 Kv Cv 2g
12
Series 300 Valves
ENGINEERING DATA
Headloss Charts
Models 30/31
MODE(Globe
LS 30 \ 31 (Pattern)
GLOBE PATTEPressure
RN) PRESSURLoss
E LOSSChart
CHART
psi mwc
10
8
10
9
6
0mm
m
8
mm
0m
7 5
0mm
, 50
, 80
, 65
m, 5 , 2 ½"
, 45 ", 20"
300 2", 14"
mm
mm
mm
mm
0mm
0mm
6
m
, 35
, 70 2"
0mm
10"
80m
40m ½", 2"
3"
4"
6"
8"
3
8
100
150
200
250
mm
400 16" ,1
1
1
mm
mm
3
24
4
3
2
1
10 100 1,000 10,000 m3/hr
3w 2w
Models 30A/31A
MODELS 30(Angle
A \ 31A (ANPattern)
GLE PATTERPressure
N) PRESSURE Loss Chart
LOSS CHART
psi mwc
10
8
10
9
6
8
7 5
0 mm
40m ", 2"
mm
mm
m
6
mm
m
4
m, 5
10"
m
3"
80m
4"
6"
8"
200
250
100
150
1½
5
3
4
3
2
1
10 100 1,000 10,000 m3/hr
3w 2w
13
Series 300 Valves
ENGINEERING DATA
h
H
Dimensions & Weights AH
Model 32 (25 bar rated valves)
R
Globe Flanged Type
Valve Size 80 (3”) 100 (4”) 150 (6”) 200 (8”) 250 (10”)
mm inch mm inch mm inch mm inch mm inch L
L 310 123/16 350 133/4 480 187/8 600 235/8 730 283/4
H 185 7 1/4 232 93/16 250 10 334 131/8 395 151/2
h** 107 4 1/4 156 6 1/8 170 6 3 /4 220 811/16 275 1013/16
W 200 7 7/8 235 9 1/4 300 113/4 360 143/16 425 163/4 W AW
R 100 315/16 120 411/16 150 5 7 /8 182 63/16 215 87/16
Weight Kg/Ibs* 15 / 33 27 / 60 51 / 112 92 / 202 171 / 377
Vol.control 0.1 / 0.02 0.3 / 0.08 0.7 / 0.2 1.5 / 0.37 4.3 / 1.1
chamber lit/gal
Valve Size 300 (12”) 350 (14”) 400 (16”) 450 (18”) 500 (20”) 600 (24”)
mm inch mm inch mm inch mm inch mm inch mm inch h
L 850 337/16 980 389/16 1100 435/16 1200 471/4 1250 493/16 1259 499/16
H 545 211/2 635 25 635 25 855 335/8 855 335/8 1311 515/8
h** 400 153/4 480 187/8 480 187/8 600 235/8 600 235/8 245 9 5 /8 H
W 489 191/4 610 24 628 243/4 850 337/16 850 337/16 881 3411/16
R 245 9 3/8 260 103/16 314 123/8 310 123/16 357.5 141/16 459 181/16 AH
Weight Kg/Ibs* 330 / 726 510 / 1124 544 / 1197 945 / 2083 980 / 2160 1030 / 2266
Vol.control 9.7 / 2.6 18.6 / 4.9 18.6 / 4.9 50 / 13.2 50 / 13.2 50 / 13.2 R
chamber lit/gal
W AW
Kv 43 115 165 345 663 1160 1600 1600 3000 3000 3000
Flow rate factor
Cv 50 133 192 400 770 1360 1900 1900 3500 3500 3500
14
Series 300 Valves
ENGINEERING DATA
Model 32 (Globe
MODEPattern) Pressure
L 32 (GLOBE PATTERN) PRELoss
SSURE Chart
LOSS CHART
psi mwc
10
8
10
0m m
9
6
8
, 60
"
", 24
7 5
0 mm
0 mm
,16"
, 20
6
, 40
, 50
4
14"
18"
mm
mm
5
m
m
m
mm
m
10"
350
450
m
m
m
12"
4"
80m
8"
3"
6"
3
100
150
200
250
300
4
3
2
1
10 100 1,000 10,000 m3/hr
3w 2w
15
Series 300 Valves
ENGINEERING DATA
Components
Bonnet Assembly
Spring
Double-Chamber Diaphragm
Conversion Kit Assembly
Body Assembly
‘F’ Version
Conversion Kit
16
Series 300 Valves
EL
of the main valve. The electric control can be added to most other control
applications.
EC
Pressure Regulating functions
PR
PR Pressure Reducing valve
Reduces high upstream pressure to a steady, lower downstream pressure,
regardless of fluctuations in the values of upstream-pressure or rate of flow.
Should downstream pressure exceed the required set point (due to
stoppage of the flow in the pipeline), the valve closes drip tight.
Dorot PR valve is also UL listed, for use in fire fighting systems.
Optional Pressure Reducing applications:
PRM
• PRM(T2) Dual Set-Point, Timer-modulated pressure reducing valve
• PRM(FM) Electronically-Controlled, Flow-Modulated PRV
• PRM(HyMod) Hydraulically-Controlled, Flow-Modulated PRV
• PR(D) Differential Pressure Reducing valve
PR(D)
Assembled in the pipeline and modulates to maintain a steady pressure in
the network upstream of its location.
Dorot PS valve is UL listed for use in fire-fighting systems.
Optional Pressure Sustaining applications:
• PS(R) Pressure Sustaining\Relief valve
• DI Differential- sustaining valve
PS
17
Series 300 Valves
FL
and opens when the water level drops.
FLDI
The valve is activated by the hydrostatic pressure of the water level. It
closes when the water rise to the requested maximal level, and opens fully
when the water level drops to the preset minimal point. The differential
between the water levels is adjustable.
FLEL
the water levels is adjustable.
18
Series 300 Valves
NS
The valve is in “open” position when inlet pressure is higher than outlet
pressure.
The valve closes, preventing returning flow, on inverted flow direction.
BC
by rapid change of the pipe velocity. Opens slowly on the pump startup,
and closes at adjustable pace before shut-off. The pump motor is then
switched-off by an electric interlink with the valve.
Optional Pump Control valve applications:
• BC/PS Pump control and Back-pressure sustaining valve
• BC/CD Pump control valve with extended closure, for long pipelines
• BC/DI Booster pump control, maintains constant flow at varying suction
conditions
DW
the Check valve. Eliminating pressure surges caused by sudden change of
the pipe velocity through start-up and shut-off.
SP Surge-preventing closure
A unique DOROT control module, that can be added to any automatic
valve. It prevents water hammer, that is generated by the valve closure,
when it is located at the end of a long pipeline.
19
Series 300 Valves
Deluge Valves
The Dorot UL Deluge Valves are suitable for systems that include Electric,
DE/EL
Hydraulic or Pneumatic detections. The Dorot 300 series Deluge Valves
are activated by each signal or by combinations thereof. All applications are
equipped with a manual emergency actuation valve and approved for use in
Fire Protection Systems as Automatic Reset or Manual Reset Valves.
Monitor Valves
The Dorot 300 Series Monitor Valves are designed to open immediately
as a response to Electric, Hydraulic, Pneumatic or manual activation. The
U-DE/EL
valves use the line pressure to develop maximum power and do not need
any external source of power.
The Dorot 300 Series Monitor Valves are designed to be activated locally or
remotely.
PR/UL
downstream pressure regardless of the upstream pressure fluctuation or
unstable flow demand.
The Dorot 300 Series UL Pressure Reducing Valves are designed to
maintain constant downstream pressure at all flow conditions.
20
Series 100 Pilots and Accessories
Plastic Mini Pilots Series 300 Valves
For valve sizes 20mm to 100mm - 3/4" to 4"
Pressure rating: 10 bar / 145 psi
Series 100
29-100 - 3-way pressure reducing pilot valve Pilots and Accessories
PILOTS AND ACCESSORIES
100 Plastic Mini
29-200
For valve
- 3-way
29-300 - 3 way sizes
Pilots
Pilots
Series 100and Accessories
multi purpose (pressure reducing and sustaining) pilot valve
20mm to 100mm
differential
3/4" to 4"
multi- purpose
Pilots and A
Pressure rating: 10 bar / 145 psi
(flow control, differential pressure sustaining)
32I S
Dorot
U N D E ER V C
E R
O YN TT HR ION L G
CONTROL VALVES I S U N D E R C O
tS E V E R Y T H I N G I S U N D E R C O N T R O L
21
‘Galit’
‘Galit’ 3-way
3-way // 22 positions
positions NC
NC or
or NO,
NO, small
small hydraulic
hydraulic relay
relay ‘GALIT’
‘GALIT’ 25-300
25-300
Series Metal
300 Valves
Relays
Metal Relays
Plastic
For Relays40mm to 600mm - 111/2" to 24"
For valve
valve sizes
sizes 40mm to 600mm - 31 /2" to 24"
PILOTS AND ACCESSORIES
For valve
Pressure
sizes 20mm
Pressure rating:
rating:
Pressure rating:
barto// 360
25 bar
25
10/ 2bar
360 psi - /4" to 6"
150mm
psi
/ 145 psiNO (66-213: NC) hydraulic relay
66-210 3-way positions
66-210 3-way / 2 positions NO (66-213: NC) hydraulic relay
25-300 3-way adjustable
66-300 / 2 positions NO w. 3/8" ports hydraulic relay
66-300 3-way
3-way adjustable hydraulic
hydraulic relay
relay
‘Galit’ 2-way
28-200 3-way // 22 positions
positions hydraulic
NC or NO,relay
small hydraulic relay 66-210 ‘GALIT’
66-310 25-300
28-200
28-200 2-way / 2 positions hydraulic relay 66-210 66-310 28-200
Relay-Valves
Mini
Mini Solenoids
Solenoids
For irrigation valve sizes 20mm to 150mm - 33/4" to 6"
For irrigation
Metal Relaysvalve sizes 20mm to 150mm - /4" to 6"
For valve sizes
Pressure
Pressure40mm
rating:
rating: to bar
10
10 600mm
bar // 145
145 psi- 1- 1/12/2” "to
psi 1
24”
For valve
Pressure rating: 25sizes
bar40mm
/ 360to 600mm
psi to 24"
Operating
Operating Voltage:
Voltage:
Pressure
66-210 3-way rating: 25 barNO
/ 2 positions / 360 psi
(66-213: NC) hydraulic relay
AC:
AC: 24V
24V
66-210
66-310 3-way 3-way
adjustable / 2 positions
hydraulic NOrelay
(66-213: NC) hydraulic relay
DC: 12V or 24V
DC: 12V or3-way
24V adjustable hydraulic relay
66-300
28-200 2-way /6-40V
2 positions hydraulic relay
Latch
Latch 6-40V
28-200 2-way / 2 positions hydraulic relay 28-300 66-210
66-210 66-310
66-310 28-200
28-200
28-300 3-way
D2 / 2 positions
D2 2-way NC
2-way NO/NC
NC solenoid
solenoid valve
valvehydraulic relay
D2
D2 D3
D3
D3
D3 3-way
3-way NC
NC or
or NO
NO solenoid
solenoid valve
valve
Heavy-duty
Mini Solenoids
Solenoid Valves
For irrigation valve sizes 20mm to 150mm - 3/4" to 6"
Heavy-duty
Heavy-duty Solenoids
Solenoids
For valve sizes
Pressure20mm
rating: to bar
10 600mm/ 145 psi- 3/34” to 24”
For
For
Pressure rating:
valve
valve
Operating
sizes
sizes
According
20mm
20mm to
Voltage: to 600mm -- 3/4
to600mm /4"" to
the selected to 24"
24"orifice and
Pressure
Pressure rating:
rating: According
According to
to the
the selected
selected orifice
orifice and
and solenoid
solenoid type
type
solenoid type AC: 24V
Operating
Operating Voltage
Voltage (others
(others available
available upon
upon request):
request):
Operating Voltage
DC: 12V or(others
24V available upon request):
AC:
AC: 24V,
24V, 110V
110V or
or 220V
220V
AC: 24V, 110V Latch or 220V
6-40V
DC:
DC: 12V
12V or 24V
or2-way
24V NC solenoid valve
DC: 12V orD2 24V
Latch
Latch 9V,
9V, 12V,
12V, 24V
24VNC or NO solenoid valve D2 D3
Latch 9V, 12V,D3 24V3-way
B2
B2 or NO 2-way
2-way NC
NC oror NO solenoid
solenoid valve
NOvalve valve
B2 2-way NC solenoid
B3 3-way NC or NO solenoid B2 B3
B3 3-way NC B3 or NO 3-way NC or NOvalve
solenoid solenoid valve
valve B2
B2 B3
B3
Heavy-duty Solenoids
For valve sizes 20mm to 600mm - 3/4" to 24"
Control Filters
Pressure
Control rating: According to the selected orifice and solenoid type
Control Filters
Filters
Operating
Self-Flushing,Voltage
Inline (others available
Stainless upon request):
steel screen
screen filter,filter,
locatedlocated
within the
the
Self-Flushing, InlineInline
Self-Flushing, �� Stainless
Stainless steel
steel screen filter, located within
AC:
main24V, 110V
valve, andorrinsed
220Vcontinuously by the stream
within the main valve,
main valve, andandrinsedrinsed continuously
continuously by the streamby the stream
DC: 12V 1 or", 24V
1 "
Sizes: 1/4”, 1Sizes:
/2”, 11/4
Sizes: /4", 1/2
/2"
Latch 9V,
External, 12V,type
"Y" 24V- Stainless steel screen installed in a "Y"
External, “Y” type
External, "Y"- type
Stainless
- Stainlesssteel screen
steel screen installed
installed in a "Y"in a “Y”
B2
shaped 2-way
body on theNCpressure
the or NO solenoid
source. valve
shaped body on body
shaped the pressure
on pressuresource.
source. B2 B3
B3 33/8",3-way NC or NO solenoid valve
/2” /8", 11/2
Sizes: 3/8”, 1Sizes:
Sizes: /2""
External,- Alarge -- A “Y
“Y Filter” FlushingFilter
Self Flushing Filter
External, large
External, large
large A large
volume
large volume external
external filter
volumeexternal filter
filter Filter” Self Flushing Filter
Control Filters
Self-Flushing, Inline � Stainless steel screen filter, located within the
main valve, and rinsed continuously by the stream
Sizes: 1/4", 1/2"
Dorot
External, "Y" type - Stainless steel screen installed in a "Y"
shaped body E source.
on the pressure
CONTROL VALVES
CONTROL VALVES E V E
V E R R Y Y T T H H II N N G
G II S
S U
U N
N D
D E
E R
R C
C O
O N
N T
T R
R O
O L
L
Sizes: 3/8", 1/2"
External, large - A large volume external filter “Y Filter” Self Flushing Filter
22
Series 300 Valves
Water Meters
Gate Valves -
Valves with Water Meters -
resilient or Multi-Jet, Single-Jet,
rigid sealing. Irrigation Meters, Woltman
Meters, Volumetric Meters.
23
DOROT AUTOMATIC CONTROL VALVES
It is all of these factors that make DOROT a leader in fluid control technology and