The CB2420A battery charger provides single phase 115-277V AC input and 24V DC, 20A output for charging open lead acid, sealed lead acid, lead gel, Ni-Cd and Li-ion batteries. It uses switching technology and a 5-stage charging curve (recovery, bulk, absorption, boost, float) for fully automatic and optimized battery charging. It has protections for short circuit, reverse polarity, overloading and monitors battery status via Modbus RTU communication.
The CB2420A battery charger provides single phase 115-277V AC input and 24V DC, 20A output for charging open lead acid, sealed lead acid, lead gel, Ni-Cd and Li-ion batteries. It uses switching technology and a 5-stage charging curve (recovery, bulk, absorption, boost, float) for fully automatic and optimized battery charging. It has protections for short circuit, reverse polarity, overloading and monitors battery status via Modbus RTU communication.
The CB2420A battery charger provides single phase 115-277V AC input and 24V DC, 20A output for charging open lead acid, sealed lead acid, lead gel, Ni-Cd and Li-ion batteries. It uses switching technology and a 5-stage charging curve (recovery, bulk, absorption, boost, float) for fully automatic and optimized battery charging. It has protections for short circuit, reverse polarity, overloading and monitors battery status via Modbus RTU communication.
The CB2420A battery charger provides single phase 115-277V AC input and 24V DC, 20A output for charging open lead acid, sealed lead acid, lead gel, Ni-Cd and Li-ion batteries. It uses switching technology and a 5-stage charging curve (recovery, bulk, absorption, boost, float) for fully automatic and optimized battery charging. It has protections for short circuit, reverse polarity, overloading and monitors battery status via Modbus RTU communication.
CB2420A Battery Charger Output: Battery charging 24 Vdc; 20 A
Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel, Ni-Cd and Li-Ion Automatic diagnostic of battery status. Charging curve IUoU, constant voltage and current Switching technology, output voltage 28.8 Vdc Five charging levels: Recovery, Bulk, Absorption, Boost, Float Protected against short circuit, inverted polarity, over Load. Signal output (contact free) for fault battery state ModBus (RTU) connection Protection degree IP20 - DIN rail
Technical features External Fuse (recommended) 16 A (MCB curve B)
The CB series is a “Switching technology” and “Battery Care Battery Output (Battery Care) philosophy”, since years parts of the core know-how at ADEL system, Boost-Fast charge Jumper Configuration Lead Acid: 2.4 led to the development of this advanced multi-stage battery charging 25°C (V/cell) NiCd:1.51 method, completely automatic and suited to meet the most advanced requirements of battery manufacturers. The Battery Care concept is Li-ion: 3.65 base on algorithms that implement rapid and automatic charging, Max. time Boost Charge (tpy. At In) 15 h battery charge optimization during time, flat batteries recovery and real Min. time Boost Charge (tpy. At In) 1 min. time diagnostic during installation and operation. The Real Time Auto- Float Charge Jumper Configuration 25°C Lead Acid: 2.23; diagnostic system, monitoring battery faults such as, elements in short (V/cell): 2.25;2.27;2.3 circuit, accidental reverse polarity connection, disconnection of the NiCd:1,4 Li-ion: 3.45 battery, they can easily be detected and removed by help of Blink Code Recovery Charge 2 – 16 Vdc of Diagnosis Led; during the installation and after sell. Each device is Charging. Max Ibatt (In) 20 A 5% suited for all battery types, by means of jumpers it is possible setting Efficiency (50% of In) 91% predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, Ni-Cd Charging current limiting Iadj 10 ÷ 100 % / In and Li-Ion. They are programmed for two charging levels, boost and Quiescent Current 100 mA float. A rugged casing with bracket for DIN rail mounting provides IP20 Charging Curve automatic: IUoU 5 stage protection degree. Detection of element in short circuit Yes Norms and Certifications Sulfated battery check Yes by Jumper In Conformity to: EN60950 / UL60950-1 and CSA C22.2 No. Short-circuit protection) Yes 60950-1-07 (Information Technology Equipment) – Safety – Part1: Over Load protection Yes General Requirement. Electrical safety; EN54-4 Fire Detection and fire Over Voltage Output protection Yes alarm systems; 2014/30/UE (EMC Directive); 2014/35/UE (Low Power Supply Mode Yes Voltage); Safety EN IEC 62368-1: 2014/AC:2015; DIN41773 (Charging Remote Input Control (RTCONN cable) Boost / Float cycle); Emission: IEC 61000-6-4; Immunity: IEC 61000-6-2. CE. General Data Signal Output (free switch N°2 contact) Insulation voltage (In /Out) 3000 Vac Dry Contact. Current can be switched (EN60947.4.1): Max: DC1: 30 Insulation voltage (In / PE) 1605 Vac Vdc 1 A; AC1: 60 Vac 1A (Resistive load ) Min: 1mA at 5 Vdc (Min Insulation voltage (Out / PE) 500 Vac permissive load) Protection Class (EN/IEC 60529) IP20 Fault System / Low Battery C NC NO Protection class I, with PE connected Main or Back Up C NC NO Reliability: MTBF IEC 61709 > 300.000 h Pollution Degree Environment 2 Signal Input / Output (RJ45) Connection Terminal Blocks screw Type 2.5mm(24–14AWG) Temp. Comp. Battery (with external probe) RJTemp(cable) Aux1 Signal: Remote monitoring data: RJ45: Aux 2 Connection Terminal Blocks screw Type 4 mm (30-10 AWG) Protocol: ModBusRTU (RS485) Protection class (PE Connected) I, with PE Dimensions (w-h-d) 150x115x135 mm Charging Automatic multi-stage charging and real time diagnostic allow fast Weight 1.5 Kg approx recharge and recovery of deep discharged batteries, adding value and Climatic Data reliability to the system hosting. Type of charging it is Voltages and Ambient temperature (operation) -25 ÷ +70°C current stabilized IUoU. The state of charging battery and Auto- De Rating Ta > 50°C - 2.5%(In) / °C diagnosis of the systems are identified by a flashing code on a Ambient temperature Storage -40 ÷ +85°C Diagnosis LED and Fault Battery LED: Humidity at 25 °C no condensation 95% to 25°C State Diagnosis LED Battery Fault LED Altitude: 0 to 2 000m - 0 to 6 560ft No restrictions Float 1 Blink/2 sec OFF Altitude: 2 000 to 6 000m - 6 560 to 20 000ft De-rating Charging Absorption 1 Blink/sec 5°C/1000m Type Boost 2 Blink/sec OFF Cooling Auto Convection Recovery 5 Blink/sec OFF Input Data Reverse polarity 1Blink ON Nominal Input Voltage (2 x Vac) 115 – 230 – 277 Auto Battery No connect 2Blink ON Input Voltage range (Vac) 90 – 135 / 180 – 305 diagnosis Element in Short C. 3Blink ON Inrush Current (Vn and In Load) I2t 35 A 5 msec. Replace Battery 5Blink ON Frequency 47 – 63 Hz 6% Input Current (115 – 230 Vac) 9 – 4.5 A Internal Fuse 10 A
All specifications are subject to change without notice