Hyva 70535211 Fe A149-3-03830-K1645-Hd-Hc
Hyva 70535211 Fe A149-3-03830-K1645-Hd-Hc
Hyva 70535211 Fe A149-3-03830-K1645-Hd-Hc
Specifications
Max. working pressure 250 bar Max. pump flow (with KO) 220 L/min Resulting tipping time (with KO) 14 sec
Weight 168 kg Max. pump flow (without KO) 190 L/min Resulting tipping time (without KO) 16 sec
Working volume 51 L Allowable lowering time 11 sec
Total volume 55 L
KO: Hyva pneumatic knock off
Max. cyl. load (start tipping) 345 kN
Extension 1 2 3 4 5 6 7 Total
Effective diameter [mm] 149 129 110
Stroke* [mm] 1260 1285 1285 3830
Technical notes
This cylinder is a lifting device only. It should not be used as a structural member and should not be subjected to side loads. When the cylinder is
mounted at an angle, the maximum tipping weight could be reduced. Maximum backwards angle of rotation during operation is 29 deg. Working
pressure depends on the application, but must never exceed the maximum working pressure stated. Working temperature range is between -40°C
and +80°C. Maximum duration of extension is 0.5 hours (excluding hard chromed stages). Cylinder is painted black (RAL9005) with a thickness
conforming to the 480 hours neutral salt spray test as per ISO 9227 (ISO 10289, rating 9).
Related documentation
Bracket options: 015BRA10 & 015BRA13 Mounting instructions: CYL-0031 Oil specifications: OIL-0011
Tipping weight
BL body length BL 5000 4850 4700
OH rear overhang OH 200 400 600 200 400 600 200 400 600
Ycog vert. pos. centre At 47 49 51 48 51 53 50 53 56
of gravity
Qo pivot length Ycog
C bracket length 400 63 68 74 64 69 76 65 71 79
At tipping angle 700 69 75 84 70 78 72
stroke x 60 / Qo 1000 76
Tipping weight at maximum pressure of 250 bar for a vertically mounted cylinder and C is 158 mm
For repair instructions see: CYL-0041. Serial no. is located on type plate and below type plate support.
Subject to change without notice, no rights reserved Page 2/2 DO-E 70535211 / 2014-9-19 / RV AA