Nubis is propeller, dry water meter Woltman’s type, with horizontal impeller axle, parallel to pipe
axles. Nubis water meters are characterized by modern construction and technology solutions,
which make them long-lasting and perfectly proved in cooperation with pulse transmitters and
remote system for measuring data readings.
APPLICATION
Water meters are assigned to industrial measurements of water usage up to 30 degrees of cold
water and up to 130 degrees of hot water in relatively regular and strong flaw rate. Construction
of the water meter gives possibility of mounting on horizontal, vertical and inclined water
supply systems with counter set upwards, sidewards or in medium position H-V. Optionally,
there is available version of water meter for demineralised water for DN40-150 (cold and hot
water) and with the input for pressure sensor (M14x1,5) for DN50-150.
ADVANTAGES
Permanent and efficient construction, ensuring the flow of water in low loss of pressure and easiness in assembly
in random waterworks installations.
Lowered weight of water meter.
Interchangeable and unified metering layer fitting to several sizes of body and assuring optimal water meter
management.
Standard water meter is suitable for remote readings in AMR system.
The possibility of mounting the water meter in the intermediate position without the influence on the metrologi-
cal parameters, larger possibilities in designing and modernizing new used water meters connections.
Very good anticorrosive and mechanical qualities of paint coat (powder paint- epoxy).
CHARACTERISTIC FEATURES
Resistant to the external magnetic field, according to EN14154-3
Low starting slow rate
Wide measuring range
Ease read-out due to a freely adjustable rotary counter dial placed in the casing
Possibility of electronic check-up of the metrological parameters of the water meter
Modular structure
Removable measuring insert in covered casing
Magnetic clutch
NK transmitter unit
NO transmitter unit
Elements of removable
measuring insert
3
Tabela 1. TECHNICAL CHARACTERISTICS
Parameter MWN, MWN-XX
Nominal diameter DN mm 40 50 65 80 100 125 150 200 250 300
Temperature class T30 (0,1÷30°C), MWN (without transmitter)
(Working temperatures range) T50 (0,1÷50°C) or MWN (with transmitter) in NK, NO, NKO, NKOP optio
TECHNICAL CHARACTERISTICS
Constant flow rate Q3 m3/h 25 40 63 100 160 250 400 630 1000 1600
Overload flow rate Q4 m3/h 31,25 50 78,75 125 200 312,5 500 787,5 1250 2000
Transitional flow rate Q2 m3/h 0,4 0,64 0,806 1 1,28 2,5 3,2 8,064 16 20,48 25,6
Minimal flow rate Q1 m3/h 0,25 0,4 0,504 0,625 0,8 1,563 2 5,04 10 12,8 16
Starting flow rate – m3/h 0,15 0,15 0,2 0,25 0,25 0,5 1,0 1,5 3 8
R measuring rate Q3/Q1 – 100 100 125 160 200 160 200 125 100 125 100
Coefficient Q2/Q1 – 1,6
Max pressure lost ΔP kPa ΔP10 ΔP16 ΔP40 ΔP10 ΔP25 ΔP25 ΔP25 ΔP16 ΔP10 ΔP10
Temperature class T130 MWN (without transmitter)
(Working temperatures range) (0,1÷130°C) or MWN (with transmitter) in NK, NKP optio
Constant flow rate Q3 m3/h 25 25 40 63 100 160 250 400 630 1000
Overload flow rate Q4 m /h
3
31,25 31,25 50 78,75 125 200 312,5 500 787,5 1250
Transitional flow rate Q2 m3/h 1 1 1,6 2,52 4 6,4 10 16 40,32 64
Minimal flow rate Q1 m3/h 0,625 0,625 1 1,575 2,5 4 6,25 10 25,2 40
Starting flow rate – m3/h 0,25 0,25 0,3 0,35 0,6 1,1 2 4 8 15
R measuring rate Q3/Q1 – 40 40 40 40 40 40 40 40 25 25
Coefficient Q2/Q1 – 1,6
Max pressure lost ΔP kPa ΔP10 ΔP10 ΔP16 ΔP10 ΔP10 ΔP25 ΔP10 ΔP16 ΔP10 ΔP10
Clase de resistencia al perfil de caudal – – U0, D0
Indication range – m3 106 107
Accuracy of indication – m3 0,0005 0,005 0,05
Upper pressure limit Pmax – MAP16=(16bar)
Working pressure range – bar from 0,3 to 16
Working position – – H, V
±5% (Q1≤Q≤Q2)
Border range error allowed ε % ±2 (Q2≤Q≤Q4) for 0,1≤T≤30°C
±3 (Q2≤Q≤Q4) for T>30°C
10000 (standard impulsion)
dm3/ 1000 (standard impulsion) 250;
NK Reed Switch pulse transmitter – 25; 100; 250; 1000;
imp. 2,5; 10; 25; 100; 250 1000;
2500;
2500;
dm3/
Optoelectronic impulse transmitter NO** – 1 10 105,2632
imp.
L mm 200 200 200 225/200 ***
250 250 300 350 450 500
h mm 65 72 83 95 105 120 135 160 193 230
Dimension H mm 177 187 197 219 229 257 357 382 427 497
H 1
****
mm 227 287 297 239 349 377 582 607 652 722
DZ mm 150 165 185 200 220 250 285 340 400 460
without transmitter 7,9 9,9 10,6 13,3/13,8*** 15,6 18,1 40,1 51,1 75,1 103,1
Weight kg
with transmitter NK | NO 8,3 10,3 11 13,7/14,2*** 16 18,5 40,5 51,5 75,5 103,5
*) Quality: NK- Reed Switch transmitter, NKP- water meter adapted for Reed Switch,
NO- optoelectronic transmitter, NKO- optoelectronic and Reed Switch transmitter,
KNOP- water mater adapted for optoelectronic and Reed Switch transmitter.
**) Only for T30 and T50.
***) On request.
****) Space for measuring insert removal.
0
65
10
Pressure loss
W 5 N
N
M N12 W
W
M
,M
mbar kPa
W 0
0
W 0
0
W ,
M 80
W 0
20
50
30
M 25
15
M N4
N
N
W
W
M
M
1000 100
TECHNICAL CHARACTERISTICS
100 10
10 1
1 0,1
0,1 0,01
0,1 1 10 100 1000 10000
Flow m3/h
5%
3%
2%
-2%
-3%
-5%
Q1 Q2 Q4
W3
W1
W2
W1
White ***
Heat meter
Transmitter NK Brown WM-BUS
Programmable meter
M-BUS
US < 30 VDC Invonic H RS485 Modbus RTU 4-20 mA (in Q function)
RS485 BACnet MS/TP Alarm 1
IS < 100 mA
RS OPTO N30o Alarm 2
Wire YTLY 2x0,14 mm2, L = 2 m
Wy2
Wy1
RS485 Modbus
W2
W1
W2
W1
W3
IO = 250 mA RS OPTO
W1
W3
W1
External
WM-BUS Walk-by data
module AMR reading
5
The information presented in the data sheet was correct on the date of publication.
The manufacturer reserves the right to make changes and improvements to its products without prior notice.