D375A-6 Fan cooling

Hydrostatic Driven Engine Cooling Fan

Fan Control System

Radiator

Engine
Motor
Motor
WaterTemp.
Water temp.
T/C outlet oil temp.
Pump
Pump

Controller
Controller. OilOilTemp.
temp.
Hyd tank temp.
Radiator and coolers
Cooling Cores

Power Train oil cooler


Cooled by Engine coolant

- Left top : A/C condenser right After-cooler


- Left bottom : hydraulic oil cooler ( From Fan motor )
Cooling fan and Fan motor
Cooling fan and Fan motor

without
Fan speed
sensor

D375A-6 D475A-5E0
Control
System diagram
Cooling Fan control map ( D375A-6 )

※coolant and hyd. Oil are on the same line


E mode
< 10℃ 10-32.5℃ 32.5-42℃ 42-45℃

D375A-6 Gross Power

Max power loss :


80 HP

D375A-6 Net Power 1185 rpm


825 1070
535
11
Hydraulic circuit
Self Pressure Reducing valve

To
PPC
To
EPC

From
LPV90
+30

To Fan
motor
Fan pumps, LPV90+30 in tandem
Fan pump(LPV90+30)
EPC valves
LPV30 Fan pump
EPC current-output pressure
-Pump delivery

The larger EPC current, the higher EPC output pressure is provided, and the
higher pressure increases Servo pressure to reduce the Pump delivery rate.

When EPC solenoid line is failed like disconnection, EPC current becomes zero
and it makes Fan pump delivery rate in maximum avoiding sudden stop of the
cooling fan. This is a Fail-Safe design.

17
LPV90 EPC current (i) = small
When EPC current (i) decreases,
EPC output pressure becomes
lower to return the Servo piston.
Flow rate of the Fan pump
increases.

When EPC output pressure


decreases, the spool(7) is pushed
back to right by the spring(6) and
The Servo pressure drains from
the large end of the servo
piston(1). The servo piston moves
down and the lever(2) returns the
spool(7) until the servo piston
stops balancing with the pressures
in the large and small ends.

18
LPV90 EPC current (i) = large
When EPC current (i) increases,
EPC output pressure becomes
higher to push back the Servo
piston. Flow rate of the Fan pump
decreases.

When EPC output pressure


increases, the spool(7) is pushed
to left and Fan pump pressure
flows into the large end of the
servo piston(1). The servo piston
moves and the lever(2) pushes
back the spool(7) until the servo
piston stops balancing with the
pressures in the large and small
ends.

19
Fan motor hydraulic circuit
Safety valve operation

When Fan pump pressure becomes high


like starting to rotate, the Suction safety
valve operates as Safety valve.

The poppet(2) is pushed up against the


spring(1) to release the high pressure to
protect the hydraulic line.
Start and stop

When stops to rotate, Pump pressure is no longer


When starts to rotate, Pump pressure rises until provided, but Fan is still rotating by the inertia and
the set pressure of the Safety valve in the negative pressure is generated. Oil supplies from
beginning. Suction valve.
Reverse rotation
The normal direction is
clockwise and oil flows
from MA to MB ( left ).

When Reverse switch is


operated on the monitor
panel, the command
current encourages the
solenoid and moves the
spool(2). Fan pump oil
flows into the
chamber(D) and the
spool(3) is pushed to left.
Oil flow direction is
changed, from MB to MA.
Fan reverse mode <When returning to fan forward rotation>
Stop the engine 1. After cleaning is completed,
<User menu screen> Key ON
2. Turn off the key and stop the engine.
3. Turn off the key and wait for ten seconds or
more.
4. Turn on the key again and start the engine to
return to the fan forward rotation.

After cleaning
Press the Decide switch F6.
Parking and lock lever must be ON

Start the engine


Fan reverse rotation
Fan speed 100% mode ( Adjust ID : 1005 )
D375A-6

Hybrid fan

Fan speed sensor


FIN