Radiator and coolers
Cooling Cores
without
Fan speed
sensor
D375A-6 D475A-5E0
Control
System diagram
Cooling Fan control map ( D375A-6 )
To
PPC
To
EPC
From
LPV90
+30
To Fan
motor
Fan pumps, LPV90+30 in tandem
Fan pump(LPV90+30)
EPC valves
LPV30 Fan pump
EPC current-output pressure
-Pump delivery
The larger EPC current, the higher EPC output pressure is provided, and the
higher pressure increases Servo pressure to reduce the Pump delivery rate.
When EPC solenoid line is failed like disconnection, EPC current becomes zero
and it makes Fan pump delivery rate in maximum avoiding sudden stop of the
cooling fan. This is a Fail-Safe design.