National Physical Planning Standards and Guidelines 2011
National Physical Planning Standards and Guidelines 2011
National Physical Planning Standards and Guidelines 2011
2011
ii
TABLE OF CONTENTS.
iii
8.4. Urban Agriculture.........................................................................................................66
8.7.0. Environmental Management........................................................................................67
LIST OF TABLES
Table 1 Site Standards for Residential Development .............................................................- 8 -
Table 2 Minimum width of Access Aisles................................................................................. 20
Table 3 Recommended parking spaces for the physically handicapped drivers ...................... 21
Table 4 Recommended Bicycle Parking Guidelines................................................................. 22
Table 5.: Urban Road Standards ............................................................................................ 26
Table 6: Walkway and Footpath Widths .................................................................................. 29
Table 7: Summary of Industrial Area and Dimension Requirements ..................................... 30
Table 8.: Way leave corridors for electricity ............................................................................. 43
Table 9 Plot Area Requirements for primary schools .............................................................. 45
Table 10 Plot Area Requirements for Health Facilities ........................................................... 50
Table 11 Plot Area Requirements for District/Local Administration .................................... 51
Table 12 Plot Area Requirements for Markets ......................................................................... 52
Table 13 Selection criteria for selection of landfill sites .......................................................... 52
Table 14 Plot Area Requirements for Recreation Facilities ..................................................... 53
Table 15: Plot Area Requirements for Police Stations ............................................................. 56
Table 16: Typical compatible land uses around airports ......................................................... 62
Table 17: Zoning and Location guidelines for Fuel Filling Stations ....................................... 62
Table 18: Types and Hierarchy of Plan ..................................................................................... 71
Table 19: Colours ...................................................................................................................... 70
Table 20: Hatching Patterns and Symbols ................................................................................ 70
Table 21: Setback distances for sewage tanks and lagoons....................................................74
Table 22: Septic Tank sizes and lagoon area requirements...................................................75
LIST OF FIGURES
Figure 1.1. Residential standards............................................................................................8
Figure 1.2: Commercial Area Standards ................................................................................... 14
Figure 1.3: Bicycle Parking Types .............................................................................................. 23
Figure 1.5: Double Stream Day Primary School....................................................................45
Figure 1.6: Urban Day Secondary School..............................................................................47
Figure No. 1.7: District Hospital...........................................................................................50
Figure No. 1.8: Local Government Offices............................................................................51
Figure No. 1.9: Typical Police Station....................................................................................56
iv
LIST OF ABBREVIATIONS/ACRONYMS USED
v
FOREWORD
Uganda has undergone fast socio-economic transformation since the eighties. This, however, has
come with socioeconomic, physical and environmental challenges that require concerted efforts at
regulating land use and development in general to achieve sustainable development. Whereas the
policy and law relating to land use and physical planning respectively have been reviewed and new
ones are now operational (the National Land Use Policy and the Physical Planning Act, 2010),
there is still need for standards and guidelines on the management of the physical planning and
development process.
The Physical Planning Guidelines and Standards in this document are therefore intended to
guide the preparation and implementation of physical development plans, with the basic aim of
ensuring orderly, coordinated and efficient development.
Uganda has hitherto lacked a coherent set of Physical Planning guidelines and Standards, which
has significantly contributed to the current disorderly and uncoordinated physical development in
various parts of the country, particularly in urban areas. Such development is costly to the
national economy, unsightly, unsustainable, and therefore undesirable. It is characterized by
conflicts in the use of land arising from incompatibility of land uses or development activities that
are normally located in close proximity.
The Ministry has thus found it necessary to consolidate existing standards relating to social,
economic and physical infrastructure provision from various sectors into one document for ease
of implementation and enforcement. And although guidelines have been developed for the
implementation of the Physical Planning Act 2010, this document and handbook also includes
guidelines on specific development processes and application of the standards.
It will be noted that circumstances in the country have changed tremendously over the years. It is
therefore imperative that Planning Standards too are revised to reflect the current realities. For
example, while it was fashionable, acceptable and practical to design huge residential plots of
more than an acre in the high income residential neighborhoods of our old towns, today this
would be viewed as absolutely uneconomical, unrealistic and grossly extravagant. Such plots are
only feasible in high income suburban neighborhoods where the use of high value land ought to
be carefully rationalized.
The process of developing the Standards & Guidelines involved comparative studies of other
countries with conditions similar to Uganda, including East African countries as well as emerging
economies of Asia and South Africa. The Ministry was assisted by a consultant is this task.
I am confident that these standards and guidelines will go a long way to ease the work of all
institutions and practitioners in the country involved in physical planning and plan
implementation. I therefore appeal to all authorities, planners, architects, surveyors, engineers,
valuers, individual developers and other stake holders concerned to co-operate in the
implementation process.
vi
Finally, I would like to express our sincere gratitude as a Ministry and in particular the Directorate
of Physical Planning and Urban Development to all institutions and individuals who contributed
in one way or another to the successful formulation of these Physical Planning Standards and
Guidelines.
Savino Katsigaire
Director, Physical Planning & Urban Development,
Ministry of Lands, Housing and Urban Development
P.O. Box 7096
Kampala, Uganda.
Email: [email protected]; [email protected]
vii
DEFINITION OF TERMS USED
Term Definition
Aerodrome A defined area on land or water (including any buildings, installations and
equipments) used or intended to be used, either wholly or in part, for the arrival,
departure and surface movement of aircrafts.
Agriculture All farming activities including cultivation, agro-forestry, bee keeping, livestock
management and aquaculture
Airfield Area prepared for the accommodation (including any buildings, installations, and
equipment), of landing and takeoff of aircraft
Apron A defined area, on an airfield, intended to accommodate aircraft for the purposes
of loading or unloading passengers or cargo, refuelling, parking or maintenance
Aviation Facility Combination of land, airspace, pavements and buildings which are needed to
support an aviation movement or action. An aviation facility can be an airfield,
heliport, or helipad. The aviation facility includes “airside” and “landside”
facilities.
Beach An accumulation of sand or gravel found at the land ward margin of a lake; the
lower limits approximating to the position of the highest and lowest tidal water
levels.
Beneficial Use a use of the environment or any element or segment of the environment that is
conducive to public health, welfare or safety and which requires protection from
the effects of wastes, discharges, emissions and deposits
Building Any structure, whether temporary or permanent, having a roof and intended for
the shelter, housing, or enclosure of persons, animals or materials.
Building Coverage The land area covered by all buildings and structures on a plot, expressed as a
percentage of the plot area.
Building Height The vertical distance from the average finished ground level of the exterior walls
of the building or structure to the highest point of dome, flat or mansard roofs or
to the mean level between the ridge and the eaves for gable, hip, gambrel, salt box,
shed or A-frame roofs.
Building Line a line drawn across a plot such that no building or permanent structure, except a
boundary wall or fence of approved design enclosing the plot, may be within the
area contained between that line and the regular line of the street on which the
plot has frontage;
Building a line which identifies suitable building area locations on airports
Restriction Line
(BRL)
Central Forest an area declared to be a central forest reserve under section 6 of the National
Reserve Forestry and Tree Planting Act, August 2003
Community an assemblage of human beings living in a defined geographical area and
identified by common history, common culture or common residence in an area
Conservation Looking after and managing a resource so that the resource maintains its ability to
fulfil its functions and provide goods and services for present and future
generation
viii
Term Definition
Corner plot A plot abutting on, and at the intersection of, two or more streets
Development Any construction, placement of material, erection of any nature grading to
improved or unimproved site
Domestic Waste Waste generated from residences
Drainage of The removal or exclusion of water from a wetland by pumping, excavation of
Wetlands channels, planting in a wetland fast growing non wetland trees or plants,
abstraction of water from a river entering a wetland, channelling, reclamation and
drainage itself
Dwelling A building or portion thereof which is designed or used as living quarters for one
family and which contains equipment and related facilities for living, sleeping,
cooking, and eating and with facilities for sanitation.
Effluent waste water or other fluid of domestic agricultural trade or industrial origin,
treated or untreated and discharged directly or indirectly into the aquatic
environment
Environment the physical factors of the surroundings of human beings, including land, water,
atmosphere, climate, sound, odour, taste, the biological factors of animals and
plants and the social factor of aesthetics and includes both the natural and the
built environment
Environmental a systematic examination conducted to determine whether or not a project will
Impact Assessment have any adverse impact on the environment
Forest an area of land containing a vegetation association that is predominantly
composed of trees of any size, and includes (a) a forest classified under this Act; (b)
a natural forest, woodland or plantation; (c) the forest produce in a forest; and (d)
the forest ecosystem;
Forest Reserve an area declared to be a central or local forest reserve under the National Forestry
and Tree Planting Act, August 2003
Frontage The required length of the front plotline measured at the street right-of-way line.
Where the front plotline is an arc, required frontage may be measured along the
required front yard setback line.
Floor Area Ratio Area covered by the development.
Hazardous any chemical, waste, gas, medicine, drug, plant, animal or micro-organism which is
Substance injurious to human health or the environment
Hazardous Waste any waste which has been determined by the authority to be a hazardous waste or
to belong to any other category of waste provided for in section 53 of The
National Environmental Management Act CAP 153
Heliport A defines area on a structure intended to be used wholly or in part for the arrival,
departure and surface movement of helicopters
Hilly Area An area with a natural elevation of land of local area and well defined outline
higher than a rise and lower than a mountain
Kilometre A metric measurement of length. 1 kilometre equals 0.62 Miles and 1,000 metres
Lake A body of fresh or salt water of considerable size, completely surrounded by land,
or a natural body or pool of water
Lake Shore The land not more than 100 metres adjacent to or bordering a lake
ix
Term Definition
Landscape The surface of the earth and the land forms of a region in the aggregate as
produced or modified by geological force and man
Soft Landscaping The enhancement of the appearance of land, especially around buildings, by
altering its contours and planting trees, shrubs, and flowers
Local Community Households and persons living in a defined geographical area and identified by
common history, common culture or common residence, and may include all the
residents of a village in a particular area
Local Government a local council established under section 4(2), (3), (4) and (5) of the Local
Governments Act, Cap 243
Medium Slope Land having a slope of between 3% and 15%
Meter A metric measurement of length. 1 meter equals to 1.09 yards or 100 centimetres.
Mountainous Area an area with a steep elevation with a restricted summit area projecting 1,000 feet
or more above the surrounding land
NEMA the Authority established by the National Environment Act, CAP 153
Natural Resource Refers to land, air, water vegetation, fish, wildlife, rivers and streams, wilderness,
natural beauty, scenery and open space
Noise Any undesirable sound that is intrinsically objectionable or that can cause adverse
effects on human health or the environment
Permanent Refers to durable wall and roof materials that can maintain stability for more than
Materials 3 years. They don’t require regular replacement.
Plot A Piece or parcel of land occupied or capable of being occupied by one principal
building and any structures or uses accessory thereto, including such yards as are
required by these Regulations.
Plot access entry or approach to the plot
Plot coverage Area of the plot that is covered by a development.
Plot size the dimensions or extent, of a piece of land in terms of how large or small it is
Pollution any direct or indirect alteration of the physical, thermal, chemical, biological or
radioactive properties of any part of the environment by discharging, emitting or
depositing wastes so as to affect any beneficial use adversely, to cause a condition
which is hazardous or potentially hazardous to public health, safety or we! Fare, or
to animals, birds, wildlife, fish or aquatic life, or to plants or to cause a
contravention of any condition, limitation or restriction which is subject to a
licence under this Act
River a body of natural surface stream of water of considerable volume permanently or
seasonally flowing in a defined channel
River Bank the rising ground, not more than 100 m long, bordering or adjacent to a river in
the form of rock, mud gravel or sand and in cases of flood plains includes the
point where the water surface touches the land, that land not being the bed of the
river;
Road reserve Area on either side of the road set aside for future expansion
Runway A defined rectangular area prepared for the landing and take-off of aircrafts.
Setbacks Rear distance from a plot boundary to a proposed development
x
Term Definition
Soil earth, sand, rock, shale’s, minerals, vegetation, and the soil flora and fauna in the
soil and derivatives thereof such as dust
Soil Erosion a general process whereby soil particles are worn away or removed by natural
agencies, including weathering, solution, corrosion and transportation
Steep Slope having a slope of 15 % and above
Street Any right of way which is used and maintained for public travel and which is
either a public street or a proposed public street as shown on a plan duly approved
by the relevant planning authority in accordance with the Town and Country
Planning Act.
Structure Anything constructed, erected, or assembled that requires a location on or within
the ground, or attachment to something having a location on the ground and has
any dimensions.
Sustainable Development that meets the needs of the present generation without
Development compromising the rights of future generations
Sustainable Use present use which does not compromise the right to use the same resource by
future generations
Sustainable the practice of human utilisation which ensures the greatest benefit to present
Utilisation generations while maintaining its potential to meet the needs and aspirations of
future generations
Temporary structure Dwelling units built with non–durable wall and roof materials that cannot
maintain stability for more than 3 years. They require regular replacement. All
housing units thatched with untreated natural fibres are classified as temporary
irrespective of wall and floor materials.
Trade Any trade, business or undertaking whether originally carried on at fixed premises
or at varying places which results in the discharge of waste and includes any
activity prescribed to be a trade, business or similar undertakings
Tree belt Stretch along roads planted with trees
Visibility splay Open stretches along road junctions
Waste any matter prescribed to be waste and any matter, whether liquid, solid, gaseous or
radioactive, which is discharged, emitted or deposited in the environment in such
volume, composition or manner as to cause an alteration of the environment
Water drinking water, river, stream, watercourse, reservoir, well, dam, canal, channel,
lake, swamp, open drain or underground water
Wetland Area permanently or seasonally flooded by water where plants and animals have
become adapted; and include swamps, mambos, areas of march, peatland,
mountain bogs, banks of rivers, vegetation, areas of impeded drainage, or blackish
salt
Wise Use sustainable use of wetlands, mountainous and hilly areas in away compatible with
the maintenance of the natural properties of the ecosystem
xi
CHAPTER 1: INTRODUCTION
INTRODUCTION AND BACKGROUND
1.1 INTRODUCTION
Physical Planning refers to the active process of organizing the structure and function
of places to ensure an orderly and effective development process. It is the deliberate
determination of spatial patterns with an aim to achieving the optimum level of land
utilization while maintaining a high degree of aesthetic quality (beauty of places) in a
sustainable way.
All spatial development activities, including industrial development, social and physical
infrastructure, agriculture, conservation, and housing, are rooted on land. These
activities often have different, sometimes competing demands. It is therefore
imperative that an overall framework that manages these development activities is in
place. Physical Planning provides this much needed framework.
Attention has been given to the consensus of the various stakeholders involved in
approving, monitoring and enforcing development control.
-1-
1.3. AIMS AND OBJECTIVES OF PHYSICAL PLANNING
The overall aim of Physical Planning is to achieve orderly, coordinated, efficient and
environmentally sound social and economic development, and to secure the proper use
of land.
-2-
CHAPTER 2: RESIDENTIAL STANDARDS
STANDARDS
The standards set out below refer to all types of residential developments categorised as
below:
In order to minimize infrastructure costs per plot, all plots should be rectangular in
shape with the frontage shorter than the depth of the plot. In certain circumstances,
the depth should be about twice the frontage width.
In high density areas, one of the side building lines of the plot may be reduced to 1 m,
provided there are no main windows on that side. The plot is then 1 m + house width
+3 m and the houses will be 4 m apart. This arrangement will only be acceptable where
all the houses in the street are to be built by one developer.
-3-
2.5 PLOT ACCESS
Every plot must have direct vehicular access to a road. Section 28 of the Public Health
(Buildings) Rules SI No. 281 states that “A building shall not be erected on any plot
which has no proper and sufficient access to a road or road reserve, such road or road
reserve not being a sanitary lane or passage”. Permission for house development will
not normally be granted until the access road has been provided. In low and medium
density residential developments, a private driveway leading to the house should be 3 m
wide. There should be sufficient turning space at the end of the drive to enable cars
turn and leave the plot in forward gear. The corner radii at the junction of the driveway
and the access road should be 3 m. Where the driveway crosses a storm water drain it
is necessary to construct a culvert to the satisfaction of the road authority.
Plot accesses for corner plots should be at the extreme end of the plot away from the
corner. Where there are sharp corners, plots should be accessed through a smaller
connector road.
2.6 DESIGN/MATERIALS
(a) All residential developments must be built of permanent materials or any other
materials whose performance has been approved by the relevant authority
(b) All roofs must be permanent and preferably non – reflective. In low and medium
density areas high quality roofing materials are recommended, though this standard
may be relaxed in smaller urban centres.
The design for residential developments also takes into account the following:
(a) Orientation of the house should be carefully considered in relation to the sun and
prevailing winds. Living rooms and canopies should preferably face the main garden.
Windows of living rooms must not over look neighbouring houses or gardens.
(b) The plot layouts should respect the physical configuration of the site, and placement of
houses should generally follow natural contours.
(c) Two or more storey developments are acceptable but care must be taken with siting,
orientation and design to protect the privacy of people in adjoining plots.
(d) Service areas of houses, e.g. dustbins, wood and other storage areas, drying areas, etc.,
should be screened from public view. This can be achieved by planting hedges or walls.
-4-
(e) Any detached developments such as servant quarters and guesthouses must be
positioned and designed to ensure privacy to the occupants of the main house and the
quarters. Windows of servant’s quarters must not face onto adjoining plots.
(f) All future extensions to the existing developments must match in terms of design,
materials and external finish.
All residential plots must be served by piped water supply, or any other suitable supply,
to the approval of the appropriate water authority.
Surface water run-off from buildings and hard surfaces must drain into the nearby
drainage channel or soak – away pit to the approval of the local authority.
2.8.3. Sanitation
In urban areas all permanent developments must have water–borne toilet facilities
drained to a septic tank and soak pit within the plot, connected to a sewage lagoon or
connected to a central sewer line system, to the approval of the local authority. Septic
tanks must be positioned so that they are accessible for emptying by a cesspool emptier.
Details of sewerage lagoons are provided in Appendix 1.
2.8.4. Solid Waste Disposal
-5-
2.8.5. Power Supply
Permitted sources of power in urban areas include electricity from the national grid,
solar, generators and wind. Electricity will be supplied to all permanent developments
in urban areas by the approved entity. Generators, solar and wind systems will be
permitted in residences subject to conditions set by the local planning authority and in
consultation with the responsible electricity regulatory body or its authorised agent.
(a) Where a metal grill is to be used, fences or solid walls must not exceed 1.2 meters in
height and a metal grill shouldn’t exceed 2 meters.
(b) Where no metal grill is to be used, wall fences should be 2.7 m or equal to the wall
plate height of the development or whichever is appropriate.
(c) In high density residential areas, solid walls must not exceed 1.5 m supplemented by a
metal grill of not more than 2 m high.
(d) Wire fences must be of chain link or barbed wire supplemented by planting where
possible.
(e) Along the road boundaries, fences or walls must be set back 1 m inside the plot to leave
space for infrastructure such as water supply.
(f) Other materials such as papyrus reeds, grass shall be permitted subject to local
authority approval.
2.10 LANDSCAPING
The appearance of a residence can be greatly improved by exemplary landscaping. It
also helps make the housing area look more attractive. The site plan should indicate an
outline of landscaping as of the planning application. Existing mature trees should be
retained wherever possible and where none exists, planting should be encouraged.
-6-
2.11 ANCILLARY USES
2.11.1. Swimming Pools
Private swimming pools are permitted. They should be positioned within the building
lines, and be fenced for safety reasons. The drainage system must be to the approval of
the local authority.
Guest wings should not be located more than 10 m from the main house connected
through a walkway. They should comprise of not more than two bedrooms plus
bathrooms.
Small structures such as poultry runs, poultry house, charcoal store, dog kennel are
permitted; provided they are well screened from the road and located at the rear of the
plot.
It is not permitted to use a residential building or plot for any business purpose.
-7-
Table 1: Site Standards for Residential Development
Low Density Medium Density High Density Detached High Density Semi-Detached
Plot Area (Sq. M) 1,000 - 2,000 600 – 1,000 300 – 600 200 – 300
Minimum Plot Width (m) 25 m 20 m 12 m 12 m
Minimum Plot Length (m) 40 m 30 m 25 m 25 m
Maximum Plot coverage 20% 40% 40% 50%
Minimum Building Lines (m)
(a). Front 8m 6m 3m 3m
(b). Side 3m 2m 2m 2m
(c). Rear 12 m 8m 2m 2m
(d). Servants Quarters 3m 3m - -
Note: Developers who would express interest in purchasing bigger plots than those provided for by the standards are encouraged to consider plot
amalgamation to meet their interests.
-8-
Figure1.1: Residential Standards
6m
Front building line Front building
line
3m 2m 2m
Minimum 30 m
Main House
floor area Main House
Side building line
3m
Minimum 25 m
Main House
Side building line
3m
PLOT AREA 300 – 600 sq. m PLOT AREA 200 – 300 sq. m
9
CHAPTER 3: STANDARDS FOR COMMERCIAL
COMMERCIAL AREAS
Uses other than those listed above will not normally be permitted in commercial areas.
Detailed information on planning and design of public services, including markets and
post offices, is contained in chapter 7. .
In all planned commercial areas there are blocks of standard-sized plots reserved for
shops, services, offices and wholesalers. Service industry can be noisy and dirty; so
these uses are confined to separate blocks of standard plots designated for this purpose.
All other facilities require special plots, and care must be taken in siting them to avoid
conflicts, e.g. bars and night-clubs should not be next to churches.
3.3.1. Front
The main front wall of a commercial building on a standard commercial plot should
have a frontage of 2m. This frontage space is for a covered walkway or Canopy of 2m
depth which then come right to the plot boundary. In the absence of a Canopy this
frontage space must be paved.
3.3.2. Side
Retail and service industry frontage should be continuous. The buildings will be
provided with walkways at certain points for accessibility. These walkways can also be
used by the emergency vehicles in case of need. It is not essential for buildings on
adjoining plots to have party walls but they must be close enough together to give the
appearance of a continuous building frontage. Narrow gaps between buildings should
preferably be closed by a front wall to prevent accumulation of rubbish, etc at the front.
Canopies should be physically linked so that customers can proceed along the canopies
from one shop to the next without having to go out or to the highway. Any forms of
physical separations between canopies creating an impression of “fencing off” shall not
be permissible.
3.3.3. Rear
A rear building line of 5m must be observed on standard commercial plots to leave
sufficient space for septic tanks, soak pit, storage, car parking and any rear servicing.
Elsewhere on non-standard commercial plots, the minimum rear building line is 3 m
providing that all other conditions on development are met.
11
3.6. PLOT ACCESS
All commercial plots must have direct access by road for vehicles and public walkways
for pedestrians. These can be to the front or rear, depending on the location and
layout of the commercial area.
3.7 DESIGN/MATERIALS
Retail, office and service industry developments should normally have a canopy along
the front for the convenience of customers. Along the main shopping streets of the
major centres development must be at least two storeys.
Shop fronts should normally incorporate a fascia for the display of the name and type
of premises in accordance with the advertisement standards and guidelines contained
in Chapter 6.
It is also necessary to provide on – site space for parking and manoeuvring of service
and delivery vehicles, preferably located at the rear of the premises. In certain
circumstances, such as small shops and service industry on standard commercial plots
with no rear access, it may be acceptable for the premises to be serviced from the public
streets or car park, across the footway. The requirements in Chapter 4 should be met.
3.9.3. Sanitation
In urban areas all commercial developments must have water–borne toilet facilities
drained to a septic tank and soak pit within the plot, connected to a sewage lagoon or
connected to a central sewer line system, to the approval of the local authority. Septic
12
tanks must be positioned so that they are accessible for emptying by a cesspool emptier.
Details of sewerage lagoons are provided in Appendix 1.
3.10 LANDSCAPING
Landscaping is not necessary on standard commercial plots. Landscaping is required
for development on the larger plots and a landscape plan must form part of the
physical planning application.
3.11.1. Markets
Most commercial areas have a site zoned for a market, and markets will only be
permitted on such designated plots. Market sites must contain provisions for customer
parking (if there is no public car park), servicing and deliveries. Markets must be
provided with adequate piped water supply, sanitation facilities, drainage, and waste
disposal, as well as covered and hygienic stalls, all to the approval of the local authority.
Site and layout standards are set out in Chapter 7.
3.11.2. Offices
Offices will not normally be permitted at ground floor level on main shopping streets
in the major commercial centres.
3.11.3. Wholesale
Wholesale premises will not be permitted on main shopping streets in the centres.
They may occupy shop plots on secondary shopping streets provided that the premises
have the appearance of a shop and comply with all other commercial standards.
13
3.11.4. Service Industry
Small workshops and services will be permitted only on plots designated for such
purposes. Warehouses should be located in industrial areas.
3.11.5. Hotels/Restaurants/Bars
Restaurants are permitted on plots designated for shops. Hotels, motels, rest houses
and bars must be located only on plots designated for such purposes and they must
have on-site car parking, servicing areas, etc, to the approval of the local authority.
3.11.7. Residential
Residential uses will only be permitted above ground floor level.
Canopy or Walkway 2m
10 m
23 m
Main Front Building Line
ONE STANDARD PLOT
30 m
13 m
14
EXAMPLE OF PLOT DEVELOPMENT
2 m screen wall
Staff Delivery Delivery
Car Yard Yard
Park
18 m
5m
30 m
REAR SERVICE ROAD
15
CHAPTER
CHAPTER 4: STANDARDS FOR VEHICLE
VEHICLE PARKING, ROADS, FOOTWAYS AND
CYCLE – WAYS
Where on-street parking can be permitted, it will usually take the form of parking
parallel to the kerb. The space needed for parking a car parallel to the kerb is 6.1m by
2m. Parking at an angle to the kerb is often more convenient but there is a greater
likelihood of accidents so it should only be used where the pedestrian and vehicular
traffic is very light. In order to encourage the best use of the space, it is advisable that
on-street parking spaces should be marked by the responsible local authority as per
their master plans on the carriage-way in colour specified by the local authority or
district engineer.
16
The principle objective is to ensure that adequate off-street parking is provided to
discourage parking on-street and hence maintain existing levels of service and safety.
The recommended levels of parking provision for each land use are generally based on
surveys and research by the Authority and represent the levels of parking required to
meet the peak parking accumulations observed. Where a proposed development is
expected to have strong seasonal characteristics, an assessment of the impact of these is
desirable. Consideration of such factors as modal split and car occupancy might also be
desirable.
Generally, all new developments must have adequate on-site parking space for the
traffic that is likely to be generated by the development including space for cars for the
workers, customers, business callers, etc. This requirement can sometimes be waived if
there is sufficient parking space available on-street or in nearby public off-street car
parks. The standards set out below are a guide to the amount of parking space needed
for different types of development. Where new developments incorporate more than
one activity, e.g. a large office attached to a warehouse, the parking requirements of
both uses must be assessed separately and then added together.
(a) Residential
A minimum of two parking spaces on a low density plot and one space on a medium
density plot. It is desirable to provide parking spaces on high density plots, but it is not
mandatory.
17
intention to provide them, it may be possible to waive the requirements for on-site
parking space.
(e) Warehouses
One parking space per 30sq.m of gross floor space plus 1 space for every 2 employees
on the largest work shift.
(g) Bars
One parking space per 15sq.m of gross public floor space is required.
(h) Restaurants, Cafes, Cinemas, Theatres, Religious Facilities and Assembly Halls
18
Minimum parking of 1 car parking space for every 10 worshippers should be allocated
and maximum shall depend on size of the facility to be provided.
For drive-in take-away food outlets of developments with no on-site seating: 12 spaces
per 100sq.m GFA will be sufficient while for developments with on-site seating: 12
spaces per 100sq.m GFA or 1 space per 5 seats (internal and external), or 1 space per 2
seats (internal only) will suffice.
Developments with on-site seating and drive through facilities: 1 space per 2 seats
(internal), or 1 space per 3 seats (internal and external) plus queuing area for 5 to 12
cars will be sufficient.
Restaurants will require 15 spaces per 100sq.m GFA, or 1 space per 3 seats, whichever
is greater.
Other facilities such as stadiums, assembly halls, theatres and places of public worship,
no specific standards of providing spaces but will be determined on merit considering:
hours of operation, availability of car parking, employee numbers and ancillary
activities.
Hospitals require 1 car parking space for every 3 to 12 beds. 2-5 parking spaces should
be allocated for people with disabilities in the visitors parking yard.
Hospitals with Accident and Emergency departments require 8 additional parking
spaces (9m x 3m) for ambulances while hospitals without Accident and Emergency
Departments, 3 additional parking spaces (9m x 3m) for ambulances will be adequate.
For Child care centers, 1 space for every 4 children in attendance will be adequate.
e) Landscaping
All off street parking facilities and parking lots should be landscaped in accordance
with the local authority byelaws or be screened within or behind buildings or be sited
at the side. This leaves the front of the building open to view from the street, and gives
pedestrians direct and safe access to the main entrance. Large unbroken expanse of
tarmac is unattractive. It is recommended instead that, all car parks be subdivided into
sections which are small in relation to the total size of the parking area. The
landscaping should include lawn, shrubs, hedges, trees, or other acceptable materials
that may be used as visual amenities. However, care must be taken on the choice of
species, construction of planting box, etc; to avoid cracking the car park surface
through root action. Trees that tend to easily succumb to winds, drop heavy leaves (like
certain types of palm trees), or branches should also be avoided. In cases where
meaningful plant material exists on a site prior to its development, such landscape
material may be used if approved by the planning authority of the local authority.
f) Vertical clearances
All provided off street parking facilities should have a minimum vertical clearance of
2.1m. Where such facility is to be used by buses and or trucks, the minimum vertical
clearance should be 4.5m. Vertical clearance should be clearly marked on overhead
structures having less than 4.8m.
h) Drainage should be provided to all off street parking facilities so as not to cause any
nuisance or damage to adjacent property as per the Building Rules and Regulations
under the Public Health Act.
i) Adequate lighting should be provided if the required or provided off street parking
facilities are to be used at night. All lighting should be designed and arranged so as to
prevent glare and excessive light on adjacent property.
j) Each parking should be painted or marked with white or cream double lines between
spaces. Signs or arrows marked by a permanent, durable, contrasting material should be
used to indicate the directions of traffic movement.
21
g) Such parking shall display the international symbols/ signs of access with words
"Handicapped Parking" and "No Trespassing." Accessible spaces for vans shall also
bear the words "Van-Accessible."
h) The following minimum parking spaces in table 3 are recommended for the physically
handicapped drivers to be applied to all public parking areas.
22
User Activity Parking Space
Shopping centre 1 per 80 sq. M sales area
Local restaurants 1 per 7 seats
Sports Arena, Halls, Swimming Pools 0.5 per clothes locker
Other gathering places 1 per 7 visitor places
Source: Ernst and Peter Neufert – Architects Data 3rd Edition
0.4
0.57
0.7
0.7
0.7
23
nature of the business operation so it is not possible to indicate standards of provision.
Advice is to be sought from Local Planning Offices and/or the Directorate of Physical
Planning & Urban Development.
e) Access Roads
These roads link to minor centers (market/local center) and all other motorable roads
i.e. distribute the traffic within districts. Major function is to provide access to land
adjacent to the secondary road system. They are further classified into major and minor
local distributors depending on the volume of traffic generated within the area they
serve. A large traditional housing area within excess of 900 houses (or 600 houses in
24
the case of low density, high car-owning areas) may need a major distributor, together
with one or more minor distributors.
Minor Access Roads – link individual plots (houses, offices, shops, industrial premises
etc.) with the distributor roads. Access roads in housing areas and shopping centres are
termed as streets and are further classified into primary and secondary streets. All
streets in housing areas must be designed for consistent slow speeds in the interest of
road safety. As high a proportion of the houses as possible should be on secondary
streets. A secondary street in a traditional housing area may serve up to 60 houses (30
in low density areas) and will normally take the form of a cul-de-sac (max. length 150m)
or loop road (max. length 500m) carrying only access traffic. Primary streets in
traditional housing areas may serve up to 120 houses (60 in low density areas). Minor
access roads in shopping centres are sometimes known as service roads.
Roads of the highest classes, (a) and (b), have as their major function to provide
mobility and have longer trip lengths. They are required to provide a high level of
service with a high design speed. The roads of Classes (c) and (d) serve a dual function
in accommodating shorter trips and feeding the higher classes or road. For these roads
an intermediate design speed and level of service is required. Roads in Class (e) have
short trip length and their primary function is to provide access to different user
activities and individual plots. Design speeds and level of service for these roads may be
low.
a) Terrace refers to a street set on hill: a street constructed along a piece of raised or
sloping ground.
b) Avenue refers to a wide street or road in a town or urban centre.
c) Street refers to a public road in town: a public road, especially in a town or city, usually
lined with buildings.
d) Rise refers to the road that goes in an upward slope or gradient.
e) Close refers to street closed at one end: a road with no exit at one end, often in a
residential area (similar to a cul-de-sac).
26
Class of Road Minimum Reserve Minimum Individual Plot Tree belt
Width (metres) Junction Spacing Access
(b). Primary Residential Street 15 - Permitted Desirable
(c). Secondary Residential Street 08 - Permitted Desirable
(d). Primary shopping street 20 - Permitted -
(Heavy commercial)
(e). Secondary Shopping Street 15 - Permitted -
(Average commercial)
(f). Service Lanes 5 - Permitted -
27
4.3.7 Walkways and Footpaths
Walkways are adjacent to roads and are included in the road reserve; footpaths follow
routes that are separate from roads.
Walking is by far the most common means of travel in Uganda’s towns. Consideration
must be given to the needs of pedestrians in the planning of all developments. In
busier areas such as shopping centres the needs of pedestrians will usually take priority
over those of other road users. There is also an important safety aspect: where adequate
footways exist the pedestrian is less likely to walk on the carriageway and the risk of
accidents is consequently much reduced.
In planning for pedestrian access, it is necessary to judge which route(s) pedestrians will
take to reach the development. Pedestrians will in general take the shortest route
possible. The location of bus stops and convenient road crossing points will also have
strong influence on the routes taken. Pedestrian links can be designed to follow the
access road into a development but it is often preferable from a point of view of safety
and convenience if a separate footpath is provided. Where the proposed development
affects a well-established pedestrian route, it will be necessary to provide a convenient
alternative route.
28
CHAPTER 5: STANDARDS FOR INDUSTRIAL
INDUSTRIAL AREAS
5.0 DEFINITION
Industry is defined as general manufacturing, processing, assembling, handling, storing
of products and materials. Industrial activity can be classified into light, general, heavy
and special uses depending on scale, noise, effluents, odours, appearance, nature of
materials, etc. Separate areas may be zoned for these different types of industry. Small
scale enterprises such as crafts, maize mills, tailoring workshops, carpentry, bicycle and
shoe repairs, tinsmiths, etc., are generally regarded as service industries which can be
located in commercial areas (Chapter 3). Industrial development will only be
permitted in areas zoned for such purposes.
Front Setbacks
Rear Setbacks
Building Line
Side Setbacks
Setbacks (M)
Average Floor
Impervious
Skyline (M)
Plot Area
(M)
(M)
(M)
(M)
Category Plot Size Coverage
Coverage Ratio
(Paving)
(%) (FAR)
5.4.1. Front
The front elevation of any building should generally be a minimum of 10 m back from
the front boundary of the plot in all categories of industrial developments. This is to
allow sufficient space for landscaping.
5.7 DESIGN/MATERIALS
There are no general restrictions on the design of industrial buildings but local
authorities should be consulted on the required materials as per the available Building
Bye-laws and Regulations in consultation with the Public Health Act CAP 281.
31
Parking space should generally be located to the rear or side of the premises but, if
some has to be in front of the building, it should be screened off the road by a
landscaped strip.
In addition to car parking it is necessary to provide on-site space for parking and
manoeuvring of service and delivery vehicles. Service areas should be located at the side
or rear of the premises. They should be hard – surfaced and clearly laid out. Vehicles
must be able to enter and leave the site in forward gear.
Generally a maximum of two vehicular access points will be permitted for each site.
The design of the access, corner radii and culverts must be to the satisfaction of the
Uganda National Roads Authority (UNRA).
Any entrance gate must be set back sufficiently inside the site to allow the largest
vehicle visiting the premises to park completely off the road while waiting for the gate
to be opened.
No such loading space shall be located closer than 15 metres to any other lot in any
residential zone, unless wholly within a completely enclosed building or unless enclosed
on all sides by a wall or opaque fence not less than 1.8 meters high.
Such loading space, manoeuvring space and all vehicles using the loading space shall be
contained within the plot.
32
5.10.3. Sanitation
Every premise must have water-borne toilet facilities drained to a septic tank and soak
pit within the plot, or to a sewer; to the approval of the local authority. Septic tanks
must be positioned so that they are accessible for emptying by tanker.
33
EXAMPLE OF POSSIBLE INDUSTRIAL STANDARD PLOT LAYOUT
5.11 LANDSCAPING
The front of any industrial plot must be landscaped for amenity reasons. Landscaping
shall apply whenever any proposed building/structure or development activity requires
34
the submission of a Site Plan application or a Special Permit application. All portions
of the property that are not required for buildings, structures, parking, driveways, or
sidewalks shall be suitably landscaped with monuments, ground cover, trees and
evergreen shrubs. Planted areas adjacent to the building shall be at a minimum of 1.8
m from the building. Loading bays shall also be screened with any combination of
walls, berms, and or landscaping.
5.12.2. Offices
Offices will only be permitted on industrial plots where they are ancillary to the main
industrial use. Where permitted, offices should occupy less than 30 percent of the
Gloss Floor Area.
5.12.3. Guard-house
A guard’s shelter or gatehouse may be permitted at the entrance to the plot and any
such structure must be of permanent materials to match the boundary wall or main
building.
5.12.5. Retailing
Retail outlets will not be permitted on industrial plots except where they are ancillary
to the main industrial uses.
35
CHAPTER 6: STANDARDS FOR ADVERTISEMENTS
ADVERTISEMENTS
6.0 DEFINITION
“Advertisement” means any word, letter, model, sign, placard, board, notice, poster,
device or representation, whether illuminated or not, employed wholly or in part for
the purposes of advertisement, announcement or direction (excluding any such thing
employed wholly as a traffic sign or a railway signal). It includes any hoarding or similar
structure used for the display of advertisements.
6.3. LOCATION
Any sign/billboard shall:
36
h) Signs/billboards aimed at directing and locating social services and facilities such as
schools, health facilities, markets, administrative centres, etc; shall have a high priority
over signs/billboards for promotion of products and services.
i) All signs/billboards shall be maintained in good repair and safe condition according to
the highest standards by the owner at no cost to the Ministry or District Local
Government or Local Authority.
6.5 AMENITY
Advertisement signs will not be allowed where they will detract the
pleasantness/attractiveness of an area. The advertisement should conform to the scale
and character of a particular area where it is located.
6.6 MATERIALS
a) Advertisement signs should be made of durable and easily cleaned materials. Plastic,
wood, metal and concrete are acceptable. All materials used for advertising should be
approved by the District or Urban Local Government, taking into account the visual,
environmental, technical and legal implications.
b) All signposts and bill boards design and erection should be supervised by a registered
professional engineer.
6.7 COLOUR
Colours should be chosen to ensure ease of reading by day-light and artificial light.
White lettering on a dark background or vice-versa is recommended.
6.8 DESIGN
Lettering should generally be not less than 50 mm high to ensure ease of reading from
a reasonable distance, but should not be more than 300 mm high to prevent the sign
being visually intrusive or a distraction.
Composite signs advertising several premises/products are much preferred as this helps
to avoid sign clutter. Such composite signs should not exceed 4 m in height and the
lettering should comply with these guidelines.
37
Illuminated signs will not normally be permitted unless it can be clearly shown that
road users will not be distracted and that the sign will be well maintained. Where
illumination is required it may be preferable to direct light on to a non – illuminated
sign for ease of maintenance.
Signs which project from a building or structure will not normally be permitted for
amenity and safety reasons.
The illumination of a structure or building for visual effect and prominence is only
acceptable in limited circumstances where the building is of particular importance and
merit. In such a case, permission should be granted by the Local Government.
6.10 CONTENT
a) No signs/billboards shall:
• Be in conflict with any law.
• Be a danger to any person or property.
• Be detrimental to the amenity of the environment on the account of size, shape, colour,
texture and intensity of illumination materials or any other reason,
• Unreasonably obscure, partially or wholly any sign/billboard owned by another
advertiser previously erected and legally displayed and
• Be objectionable, indecent or suggestive of indecency or prejudicial to public morals in
its content.
38
g) Have all exposed metal work or otherwise treated to prevent corrosion and decay in
case of timber structures;
h) Be constructed to prevent the entry of water into and the accumulation of water or
moisture on any part of its supporting frame work, brackets or other members;
i) Be constructed or in the case of removing it, cause no damage to any property, tree,
public services/installations or road. No parts of any damaged or removed sign shall
remain in the road reserve;
j) Be constructed to allow adequate clearance from ground level to permit free movement
of pedestrians;
k) Be designed (in case of structural elements and foundations) and constructed under the
supervision of certified registered Engineer. Proof of the design having been done by a
certified/registered Engineer shall be required;
l) Be maintained in good repair and safe condition according to the highest standards as
regards to quality of structures, boards and signs/billboards by the owner; and
m) Be removed by the owner at no cost to the public if the space on which the sigh is
erected is required for other purposes. A notice of 90 days shall be given to the owner.
n) Approval of erection and display of sign/billboards shall be granted for a definite
period of time. Depending on the size of the sign/billboard, its location and materials
used the Ministry or District Local Government or Urban Authority will grant approval
for a limited period of time ranging from 1 – 5 years. Upon the expiry of the lease, the
owner of the sign/billboard may reapply or remove the sign/billboard at his/her cost.
39
CHAPTER 7: STANDARDS FOR SOCIAL SERVICES, UTILITIES AND GOVERNMENT
FACILITIES
7.1 GENERAL
The utilities and social services considered in this document refer to those facilities
normally provided by the Government or local authorities for the benefit of the general
public. These include: primary and secondary schools, health care facilities,
administrative offices, courts, post offices and telephone exchanges, produce markets,
sports fields, and police stations.
Most social services are best located in commercial centres. With the exception of post
offices and produce markets, they should be sited away from the main shopping streets.
It is also advisable to keep them away from industrial areas and entertainment facilities.
Schools should not be sited in commercial centres but in convenient locations within
the residential areas they are to serve.
7.1.4 Design/Materials
All social service buildings must be constructed of permanent materials. Roofing
materials must also be permanent and non-reflective. In certain areas a high-quality
roof finish such as tiles or cooler blocks may be required.
7.1.7 Utilities
Water
There should be a separate piped water supply for each user activity, or other suitable
supply - to the approval of the local authority.
Sanitation
Every premise must have water-borne toilet facilities drained to a septic tank and soak
pit within the plot, connected to a sewer lagoon or to a central sewerage system, to the
approval of the local authority. Septic tanks must be positioned so that they are
accessible for emptying by tankers. Details of sewerage lagoons and septic tanks are
provided in Appendix 1.
Waste Disposal
Any refuse must be sorted and stored in proper containers for collection and
appropriate disposal by the respective Local Authority, to the approval of the local
authority. Hazardous wastes will require special treatment.
Power Supply
Electricity will be supplied to all permanent premises by the relevant electricity
distribution companies, by private generator, solar system or any other approved
system, to the approval of the local authority.
41
Table 8: Way leave corridors for electricity
Item Recommendation in Metres
Way-leaves corridor (Meters) 66 KV - 20 m
132 KV - 30 m
220 KV - 40 m
440 KV - 80 m
Minimum vertical distance below the 66 KV - 8.0 m
transmission lines 132 KV - 8.5 m
220 KV - 9.5 m
440 KV - 10 m
7.1.9 Landscaping
Landscaping shall be done to enhance amenity of the site and provide shade, privacy,
and screening.
42
neighbourhoods or within existing primary schools or can be incorporated in existing
religious institutions.
In urban areas, walking distance will depend on the spatial distribution while in rural
areas a minimum distance of 1.5km is recommended. Existing and proposed primary
schools should be encouraged to incorporate day care centres/kindergarten and
nursery schools where possible.
Guidelines
In urban areas standards will be affected by the scarcity of land and the high values.
Therefore, developers should take advantage of vertical developments. The minimum
plot area requirement for nursery schools is 2,000 sq m.
Locational requirements
• Site must have access roads.
• Avoid busy roads.
• They should not be located near incompatible land uses such as bars, cinemas.
• In high and medium income areas, parking facilities should be provided to manage
vehicular traffic and eliminate obstruction to vehicular traffic flows.
b) Primary schools.
Recommended plot areas for primary schools are given in table 9. These are sufficient
to accommodate school facilities, playing fields and demonstration gardens for single
stream day and boarding primary schools only.
For playing fields, schools may utilise nearby facilities where these are available and can
be safely accessed. In such cases authorities have to avail documented evidence of access
from the owner.
Vertical developments should be encouraged in urban areas to save on space provided
that classrooms shall not be beyond the 3rd level from the ground. Sanitation: 1 toilet
stance for every 40 students is sufficient.
Location Guidelines
i) They should be located within residential neighbourhoods and easily accessed by road
ii) In case pupils are dropped and picked by cars or public transport, facilities for safe
collection and parking should be available.
iii) It is also important that applications for educational institutions include details of all
relevant information to facilitate the responsible Urban Authorities determine the
required acreage. It is also required that after land for educational facilities has been
allocated, site layout plans and other drawings be submitted to relevant authorities for
guidance, approval, monitoring and evaluation to avoid haphazard developments.
43
iv) All educational institutions should be integrated with major open spaces whenever
possible to encourage the sharing of open spaces and play grounds with members of the
public.
v) Must not be in industrial area, wetland or forest reserve.
Urban primary schools should normally be designed for double or triple streams to
make efficient use of resources. A typical layout for a double-stream day primary school
is shown in Figure 1.5.
On the above minimum areas provided for primary schools, an addition of 0.4 - 0.8 ha
is required for agricultural demonstration plots (school gardens) where applicable. It
should be noted that, all schools expand even if a school will start as a single stream
initially; it should be allocated a minimum of 4.7 ha to cater for future expansion.
In case members of teaching staff are to be accommodated on site, an additional land
of 0.8 ha should be allocated for staff housing. The houses should be flats whenever
appropriate to economise on space.
If it is a boarding school, then 0.4 ha should be added on to cater for every 200
students in terms of dining halls together with dormitories in a storied building.
Walking distances for rural schools should be 0.5 - 3 km while for urban areas, it
should be between 0.5 - 2 km. However in urban areas, the location of education
services depends on the catchment population, availability of land for development and
the preference of consumers than distance travelled.
44
Figure 1.5: Double Stream Day Primary School
c) Secondary schools
Recommended plot areas for day and boarding secondary schools are for a single
stream mixed secondary school with Senior 1 - 6, 3.5 ha for double stream mixed
secondary school while 4.5 ha is sufficient for triple stream mixed secondary school.
This includes space for a senior football field encircled by running track, plus
basketball, volleyball, netball pitches and demonstration gardens.
45
If it is a boarding school, then 0.4 ha should be added for every 200 students to cater
for dining halls together with the dormitories preferably in storied buildings. Since all
schools expand, even if a school starts as a single school, it should be accorded the
minimum area of 6.0 ha so as to forestall the problem of land shortage in case there is
need for expansion. Each school should therefore be developed on a three stream
capacity.
A typical layout for an urban day secondary school is shown in Figure 1.6. It is
recommended that new secondary schools in large urban areas be for day pupils only.
In general there needs to be a secondary school for every 50,000 people.
School buildings in urban centres should preferably adopt the vertical concept of
buildings most especially the boarding schools to reserve land for future expansion and
save space. If there is a playground nearby and there is proof of access from the owner
to the school authorities, then another one is not necessary.
Location Guidelines
i) (As for primary schools).
46
Figure 1.6: Urban Day Secondary School
SCALE 1:1250
d) Tertiary Institutions
These include colleges and Universities. Their establishments, standardisation,
accreditation and supervision rules are contained in the relevant laws and regulations.
Minimum land area required for colleges is 4 - 6 ha.
47
Guidelines for University Institutions
The land size for a University should be at least 50 ha comprising of the following:
a) 20 ha to support up to 500 students.
b) 10 ha for the main campus.
c) 2 ha for auxiliary services e.g. nursery school, staff quarters (teaching and non-
teaching staff).
d) 2 ha for open spaces and car parking exclusively.
e) 2 ha for land set aside for sewerage plant (if there is no central sewerage system).
f) 5 ha for outdoor sports for 500 students.
g) 10 ha for farm land for a university offering agriculture as a course.
h) Every university should provide the following minimum physical facilities to
accommodate its activities:-
i) Lecture rooms.
ii) Departmental areas, staff offices, and seminar rooms.
iii) Central administration areas.
iv) Library.
v) Auditorium/Lecture Theatre.
vi) Staff common rooms.
vii) Students’ common rooms with indoor recreational facilities.
viii) Outdoor recreational facilities in from of games or sports facilities.
ix) Drainage systems, proper sanitation and water supply.
x) Dispensary or preferably a hospital.
i) Every residential university, shall in addition to the above, provide:
i) Kitchen and dining facilities.
ii) Students’ accommodation including adequate laundry and storage facilities.
j) A university offering Urban and Regional Planning shall have adequate studio
space for every year of study and the university shall have a model making
workshop.
k) A master plan should be prepared in accordance with these standards and all
applicable laws and regulations to ensure that all facilities and proposed
developments are functionally related and compatible and all administrative
buildings, lecture rooms and other facilities are in close proximity to one another.
Guidelines
a) Planning for health facilities in urban areas should take into consideration the high
land values and scarcity. It is therefore recommended that, developments in urban areas
take advantage of vertical extension to save on land.
b) Accessibility of 5 km walking distance should be applied to areas that are hard to reach
(especially the rural areas).
48
c) Area selected must be able to accommodate the various minimum functions of the
health facility as per the Ministry of Health provisions (standards and guidelines) except
where local circumstances require otherwise.
d) Developments in the rural areas should take advantage of the large expanses on land
available where possible.
e) Under 5 year’s clinics and HC I shall be accommodated in commercial, institutional
and residential developments/structures. They should be located at the edge of the
commercial centre. However, they should have no direct access from the main road.
f) Hospitals should be located along main road but should not have direct access from the
main road. While Rural Health Centres be located on the edge of commercial centre
for convenience and ease of accessibility - due to the access roads that converge within
the commercial areas.
Typical layouts for district hospitals and urban health centres are shown in figure 7.4.
49
Figure 1.7: District Hospital
These facilities shall be well landscaped with adequate greenery around them.
7.2.5 Markets
Markets are usually the main focus in commercial centres and should be located
accordingly. They should be close to public transport services. The market must have
its own car park and service/delivery yard. The selling area should be enclosed by a wall
or fence. There should also be lock-up shops for butchers, fishmongers, etc., and stalls
for the sale of fresh fruit and vegetables.
The market should also provide facilities for craftsmen. A wood-fuel yard is also needed
either within the market fence or adjacent to it. Public toilets must be provided.
Recommended plot areas are given in table 12.
Table 12: Plot Area Requirements for Markets
Type Market area Car park/ service Total plot area
yard area
Town centre 1.0 ha 0.3 ha 1.3 ha
Neighbourhood centre 0.8 ha 0.2 ha 1.0 ha
Local centre/ trading centre 0.4 ha 0.1 ha 0.5 ha
51
7.2.6 Sanitary Landfills
Guidelines for locating a landfill site
i) Located away from; Airports (at least 2 - 5 km & outside of the approach and take off
zones), populated areas (200 m away), Wetlands, national parks and areas with precious
flora and fauna, Seismic Impact Zones, Flood Prone Zones, ground and surface water
sources and historical, religious and other important cultural sites or heritages.
ii) Sufficient consultations must be carried out to avoid conflicts with the neighbouring
community members.
iii) Sufficient cover material should be available nearby.
iv) Existing site utilities such as underground pipes or conduits (for sewage, storm water,
etc.) must be avoided unless their relocation is feasible.
v) Areas must be easily accessible by delivery vehicles.
vi) EIA must be carried out.
52
7.2.7 Recreation Facilities
Recreation areas can be public or private. Areas of recreation may include areas of
scenic beauty; areas of cultural or historical importance; unique physiographic features;
parks, forests or water masses, play fields, stadia, green spaces, zoos, snake parks,
museum and amusement parks, discotheques, cinemas and conservation areas.
There is need for recreation facilities both in urban and rural areas due to:
a) Need for relaxation/economic activities
b) Income generation/ economic activities
c) Social interactions
d) Tourist attractions
e) Set as carbon sinks/breathers
f) Preservation of socio-cultural and or religious values
g) Environmental conservation areas - forests, trees, flower planting, etc.
h) Competing users due to population pressure hence overcrowding in informal
settlements
Recommended plot areas for the most commonly provided sports and play facilities are
given in Table 14. Such facilities are normally located adjacent to commercial centres
and near other community facilities. The recommended plot area will accommodate
the playing area and enough space for spectators. With some facilities such as a senior
football pitch, there may be a need for additional land for a car park.
53
For a 9 hole course, an area of 5 - 10 ha is required with a population of 100,000
people within less than 30 minutes drive while for an 18 hole course, an area of 55 ha -
60 ha is sufficient.
The optimum size is 1.2 to 2.8 ha, but these parks may be larger if significant natural
resource land is incorporated. The site should have at least 60 m of street frontage with
on street parking. Larger sites shall reserve area for off street parking. Active and noise
producing facilities, such as basketball courts, should be located at least 30 m from
nearby homes or property zoned for residential use. They are often located next to
elementary schools.
c) Community Parks
These provide primarily active and structured recreation opportunities on sites
designed to serve several neighbourhoods. Typical developments may include sports
fields, trail systems, group picnic areas, and are designed primarily as a “drive-to” park
rather than a “walk-to” park.
Typical users come from within a distance of 1.5 km to 3 km, travel by vehicle, bus,
foot or cycle and visit the park for at least 1-3 hours. Site range from 8 to 30 ha in size,
depending on the spatial requirements of the facilities provided and the amount of
land dedicated to natural resource protection.
The site should be visible from adjoining streets and have a minimum of 120 m of street
frontage. Parking requirements should be based upon the facilities provided at the site.
Generally, 50 off-street spaces per ball field are required, plus 5 spaces per acre of active use
areas. Citywide Parks
They offer the most diverse and/or unique recreation opportunities in the park system.
They are designed to serve the entire jurisdiction with features that are also intended to
attract visitors to the city, generating substantial economic benefit. Citywide parks also
54
are typically supported by nearby food services, lodging and other services necessary to
accommodate extended use of the park by out -of-town guests.
Because of the diverse and unique offerings, citywide parks typically contain more open
space and support facilities. Users come from throughout the city, arriving by vehicles,
bus, bicycles or foot and visit the park for 2 - 4 hours or more. The site size will
generally exceed 20 ha and should be sufficient to accommodate the park’s unique
features and or amenities. Parking requirements should be based upon the facilities
provided at the site. Generally, 50 off-street spaces per ball field are required, plus 5
spaces per acre of active use areas.
55
For police barracks, accommodation is dependent on the available land ranging from
0.2 ha - 1.7 ha as an addition to the institutional facilities
56
d) Adequate on–site parking should be provided to the approval of the local authority.
a) Standard District Fire Stations require an area of 0.3 – 0.5 ha with a minimum frontage
of 47 m and should be easily accessed from the main roads.
b) Municipal and other smaller Fire Stations require a minimum land area of 0.2 ha with
a minimum frontage of 35 m and accessed through the main road.
c) Additional minimum area of 0.4 ha is required for staff accommodation and drilling
area.
d) A small fire station would require a minimum of 30 staff members to cover a
population of 50,000 - 100,000 depending on the degree of fire risk.
It is important to note that, exclusive churches need to be provided at the fringes of the
central business district while a mosque and a temple may be located within the central
business district to cater for the business community. The selected sites must be large
enough to accommodate the institution, parking requirements of the worshippers,
public convenience and housing for the clergy where possible.
Airport planning must be recognised as an integral part of the area wide comprehensive
planning programmes. The location, size and configuration of the airport need to be
coordinated with patterns of residential, industrial, commercial, agricultural and other
land uses of the area, taking into account the effects of the airport on the people, flora,
fauna, the atmosphere, water courses and other facets of the environment.
There is need to control land use in the vicinity of airports in order to ensure that
possible height hazards or obstructions to flights into or out of the airports are
58
minimised. Experiences on non-conforming purposes or land uses have indicated the
need for control. Such uses include:
a) Uses which may cause electrical interference with radio communications and
navigational aids.
b) Lights which might confuse pilots in the clear interpretation of aeronautical lights.
c) Smoke which reduces visibility.
59
carried into streams. Pest control which involves the use of sprays introduces long life
toxic chemicals into the water system. Fuel spillage from equipments and chemicals
employed in building and pavement construction works can also contribute to upset of
the hydrological balance of waterways in the sea. Changes to the natural drainage
patterns of an area may occur due to construction of an airport. This may in turn
overtax certain streams and give rise to flooding and certain streams may dry up due to
the diversion of the flow.
e) Noise: The intensity and nature of aircraft engine noise is quite variable depending on
the engine type and the nature of operation being undertaken. Noise nuisance
associated with airports is also closely related to frequency of aircraft operations and
their diurnal distribution: for example noise at night is more of a nuisance than the
noise during the day time. High levels of noise are most undesirable. Noise is a
particular health hazard to employees who because of their work are subjected to long
durations of intense aircraft noise. Strict precautionary measures are necessary for these
people such as mandatory usage of acoustic protective devices. The repercussions of the
excessive airport noise in residential areas are primarily of a social and behavioural
nature. Table 8.9 indicates the types of uses which may be allowed in the vicinity of
airports. Trees may be planted to screen certain areas from airport noise. Good
protection against ground run up noise might be expected from judiciously planted
trees. When proposing trees to be planted for the development of a sound insulating
forest, consideration should be given to species that:
i) Are suitable for the climatic conditions of the airport site.
ii) Have effective sound insulation properties for instance do not shed off their leaves
or grow rapidly and densely.
iii) Do not generate bird hazards.
iv) Are easy to cater for after their growth for example healthy and not readily affected
by blight or noxious insects.
f) Environmental Impact Assessment (EIA): Detailed study of the impacts of the airport
development on the environment is an essential part of the assessment of any major
project. Social - ecological impacts should be investigated fully before work is
undertaken or in the case of the new airport, when the site is being selected.
Environmental impact studies depending on the nature of the project, take into
account the following:
i) Compatibility with the community including health, transport and social
implications
ii) Influence on ecology including effects of pollution preservation of flora and
fauna.
iii) Means of overcoming any problems.
60
Table 16: Typical compatible land uses around airports
Examples of compatible land uses Zones
A B C
Agriculture, Crop Farming
Industrial, Machinery Workshop
Commercial
Warehousing and Shipping
Office and Banking
Residential: Low Density Housing
Public facilities (Schools)
Note:
i) The length of the bar indicates where land uses might be permitted without restriction
in relation to aircraft noise exposure only; and excluding other planning considerations
with respect to certain uses. For example housing, commercial or other developments
might be allowed in a zone of higher restrictions when other planning considerations
indicate a need and where suitable building techniques, sound insulations can reduce
the aircraft noise exposure to acceptable levels.
ii) In special cases of activities dependent on speech communication, such as schools or
require more stringent standards for example certain hospitals activities, additional
restrictions may be required to take account of absolute noise levels as well as building
constructions. The zones will require to be defined against noise exposure scale and in
their application will need to take account of local and national needs.
61
7.4.3 Guidelines for Bus/Taxi Parking Bays along roads
a) There is need to ensure that bus and taxi parks are accessible to the elderly and the
physically challenged.
b) There is need for the responsible authority to designate areas for parking bays along
roads.
c) There is need to provide shelters on the designated bus/taxi parking bays along the
roads.
d) Each bus stop location shall be marked with a rectangular blue sign atop a tall curb side
pole accompanied by a display of schedules for each bus route serving the stop as well as
restricted parking signs where applicable.
e) Most buses are 2.5 m to 3.5 m high. The minimum vertical clearance for buses should
be no less than 3.6 m, with 4.4 m as the desirable clearance.
63
Security & Safety
f. Readily identifiable signage, informing the public as to who are the operators of
the site & their emergency numbers shall be posted at a conspicuous position at
the site.
g. All towers over 30 metres shall be painted & treated as stipulated by Civil
Aviation Authority (CAA).
h. All applications proposed to be located within a 3 km radius of airports,
aerodromes, similar facilities & flight paths shall be referred to CAA for
consultation before determination.
Mast Sharing
i. Where practicable, the planning authority shall require that the operator/applicant
demonstrate that all reasonable steps have been taken;
i. To investigate mast sharing before seeking to erect new ones
ii. To pursue the possibility of cooperating with another operator to erect new
mast for joint usage.
j. Planning authorities shall be required to maintain a register of all applications for
telecommunication masts/tower site. This shall be made available to operators to
allow them to consider the possibilities of mast sharing when planning the
development of telecommunication networks.
The planning authority shall ensure that apparatus no longer required for
telecommunication purposes are removed as soon as reasonably practicable from the land
or building on which it is located and the land restored to its previous condition.
64
CHAPTER 8: MISCELLENEOUS STANDARDS
Location Guidelines
• should be located away from residential areas or sensitive uses
• in urban area and new towns, they should be accommodated on the periphery of
industrial areas, either in purpose-designed buildings or on the lower floors of
industrial buildings
• additional safety and fire prevention equipments are necessity; in rural areas, they
should be provided for in low rise buildings of 1 - 2 storeys; maximum plot ratio of 0.5;
provided with water supply and proper sewage disposal system and adequate paving
and drainage to minimise land contamination and drainage problems as well as fenced
to reduce visual impacts of unsightly developments.
8.3 ABATTOIRS
The following guidelines should be observed in the development of an abattoir.
a) Location and site.
i) Minimum site area of 1800 sq. m
65
ii) Distance from urban development i.e. should not be located close to residential
developments, education institutions, religious institutions, public and commercial
buildings
iii) Accessibility i.e. the site must be accessed by road
iv) The site must have adequate water supply
v) Effluent disposal i.e. the site should be free draining and not subject to water logging
and flooding
vi) Solid waste disposal: there should be sufficient space available for waste management by
either incineration or disposal in a pit. Pit is recommended for small abattoirs and
should not extend below the normal water table.
b) Design Requirements
i) Slaughter hall/floor
ii) Large area: should be large enough to hold the expected daily number of animals for
slaughter
iii) Soak-away pit for drainage
iv) Fencing should be provided
v) Amenities and office areas
Buffer zones for wetlands should consider soil type (colour, Composition); vegetation
type; depth of water table; topographical features/contour levels; existing and agreed or
recognised customary boundaries that favour the wetland.
8.5.3. Projects that require the preparation of Environment Impact Assessment (EIA) to
be conducted before implementation
i) Urban developments such as townships, industrial estates, shopping centres, and
complexes.
ii) Transportation including the major roads, railway lines, airports, airfields, pipelines,
and water transport.
iii) Dams, rivers, and water resource - storage dams, barrages, weirs, river diversions,
water transfers, flood control schemes, drilling purposes of utilising ground water
resources including geothermal.
iv) Aerial spraying.
v) Mining - including quarrying and open cast.
67
vi) Forestry related activities.
vii) Agriculture.
viii) Processing and manufacturing industries.
ix) Electrical infrastructure.
x) Waste disposal activities.
xi) Natural conservation areas.
xii) Any other activity which will result in a material change in the character of an area,
with the surroundings, a structure of a scale not in conformity with its surroundings
and major changes in land use.
68
CHAPTER 9: STANDARDS FOR PLAN SCALES,
SCALES, NOTATION AND GRAPHICS
9.0 Definition
A physical development plan drawing is a plan showing geographical (spatial)
distribution and pattern of the various proposed land use activities. For a physical
development plan drawing to be meaningful, the presentation involves illustrations of
bearing, scale, hatching, colouring and/or use of symbols. The main aim is to facilitate
ease of plan interpretation and understanding and enhance the quality of technical
drawing.
69
9.3 Colours of Plans
The colours indicated below are recommended to be used for all types of physical
development plans and particularly local plans. Sub classes of the same land use type
use different shades of the same colour. For example; high density residential uses the
darkest shade of the same colour. In addition, abbreviations and / or symbols are used
together with the colours to differentiate land uses having the same colour on the plan,
but are different in nature.
Some uses would take any colour depending on which land use they are located e.g.
offices in commercial areas would be indicated as commercial use.
Medium Density
5 sq. mm pt 0,25 Unplanned Area
70
Commercial Area Secondary Road
2 mm apart vertical lines pt Black bar 1.0 mm thick in
0,25 the centre or road
Landscape/Tree Belt
Flower signs shed all over
with dots. pt 0,35
Agriculture
5,0 mm lines 5,0 mm
Zebra Crossing/Pedestrian
parallel and 4,0 mm gap pt
Crossing
0,35
Afforestation Railway Line
Flower signs shed all over One line and 2.0 mm
without dots hyphens 5.0 mm apart pt
Open Space 0.5
5 mm lines shed evenly 5
mm apart pt 0.25 Bridge, Culvert
71
School
Quarry
Primary School
Training College
Fire Station, Police Station
Mountain/Hill or valley
depending on contour
values ascending or
descending order.
Post Office
River/Stream (solid line
with distributor) Filling Station
Golf Course
Camp Ground
Permanent Building
Hotel
Motel/Inn
Rest House
Restaurant/Refreshments
Church
Mosque
Hospital
Health Centre
72