AR-721KP
V110810
ACCESS CONTROL SYSTEM
Contents
1 Product 2 User Guide 3 Tools 4 Specification
Specification
Users 500 Power consumption < 2W Memory EEPROM Weight(g) 100±10
Digits 3-6 Operating Temperature -20℃ to +60℃ Color Gray/Silver Housing Material ABS
Power Supply 9-16VDC / 100mA Indicator 1 Bi-Color LED&1Beeper Dimensions(mm) 111(L) x 77(W) x 26(H)
Installstion
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
4 Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Terminator
CN1 CN2
Wire Appllcation Wire Description Wire Appllcation Wire Description
CN1
N.C. 1 N.C. COM 1 COM
N.C. 1 Relay_A N.O. 2 N.O. Relay_B N.O. 2 N.O.
N.O. 2
COM
ERG
3
4
COM 3 COM N.C. 3 N.C.
CN2
DLY
GND
5
6 EGR 4 Negative Trigger Input for Relay_A T a m p e r SW 4 N/O or N/C select via jumper
12V 7 Exit Switch
DLY 5 Negative Trigger Input for Relay_B Switch SW 5 COM
COM
N.O.
N.C.
SW 2
SW 1
SGND
Wiring Diagram
GND 12V
POWER POWER
12V Diode GND
12VDC 12VDC
Electric Strike
CN1
1
N.O. 2
Electric Bolt Keypad COM 3
N.O.
EGR 4
DLY 5 EXIT Installation Notice
N.O. 6 Don’t equip controller and lock with the same power supply.
SGND
COM
N.C.
7
Request To Exit The power for controller may be unstable when the lock is
1 2 3 4 5 6 CN2
EXIT
GND
POWER activating, that may make the controller malfunction.
12V
12VDC The standard installation: Door relay and lock use the same
Request To Exit power supply, and controller use independent power supply.
Programming
A. Entering and Exiting Programming Mode
Entering Exiting
Input 123456 or PPPPPP Input
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → Access programming mode
Changing the Master Code
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input 123456 → 09 876112876112
Factory Reset by its commands
If the master code is forgotten it can be restored to the factory default. Remove the AR-721KP from the mounting plate. Press and hold the reset switch
5 seconds. LED light green during 2.5 seconds and five beep sounds mean that master code have restored to the factory default 123456.
B. Set up user number corresponding to door relay
Access programming mode → 01 UUUU UUUU=User address (Default value = 0250)
[User number 0000~0249 operates Relay_A; User number 0250~0499 operates Relay_B.]
C. Add a User Code to the system
Access programming mode → 12 UUU PPPPPP
UUU(User address):001~254;PPPPPP(User Code):The user code must be 3 to 6 digits in length and the key # cannot be used in a code.
[e.g.] Set user code 123 to user 001: [e.g.] Set user code 123456 to user 002:
Access programming mode → 12 001 123 → Done Access programming mode → 12 002 123456 → Done
D. Set the door relay-1 release time
Access programming mode → 02 TTT TTT = 000 Latch(Toggle) / TTT = 001~600 (001~600) seconds.
Set door relay_B, enter 03. TTT =601~609 (0.1~0.9) seconds.
E. Set time out value
Access programming mode → 04 TT TT = 00~09 (0~0.9) seconds; TT = 10~49 (1~4.9) seconds
F. Set keypad lock of continuous error operation
Access programming mode → 05 T T = 3~9 (times); T = 0 (Close this Function)
[e.g.] Set three incorrect user code are entered:Access programming mode → 05 3 → Done
G. Set Door bell ( + Door Ring)
Access programming mode → 06 PPP PPP = 000 (Disable) / PPP = 001 (Enable) [If use two access groups, places set disable.]
Command List
Function Command Exposition
Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
UUUU=User address, (Default value: 0250); User before the
User number corresponding to door relay 01 UUUU
250th is the first group, the other is the second group.
TTT=Door relay time;000 (Output constantly)
Relay_A time setting 02 TTT
001~600=1-600 Sec.;601~609=0.1~0.9 Sec.
TTT=Door relay time;000 (Output constantly)
Relay_B time setting 03 TTT
001~600=1-600 Sec.;601~609=0.1~0.9 Sec.
TT=Keypad operate during time
Set time out value 04 TT
Range:00 ~ 09 (0 - 0.9) Sec.;10 ~ 49 (1 - 4.9) Sec.
Set keypad lock of continuous error operation 05 T T=Continuous error times:3 ~ 9 (Times);T=0 (Disable)
Door bell 06 PPP PPP=000 ( Disable ) / PPP=001 ( Enable )
PPPPPP= New master code
Master code settings 09 PPPPPPRRRRRR
RRRRRR= Repeat the new master code
Suspend or delete user code 10 SSS EEE SSS= starting user address ; EEE= ending user address
Recover user code 11 SSS EEE SSS= starting user address ; EEE= ending user address
UUU=User address
Add a User Code to the system 12 UUU PPPPPP
PPPPPP=3 to 6 digits
Delete (Remove) a User Code 14 UUU UUU=User address
Delete (Remove) all Users Codes 29 29