Tanque: Equipment Data Sheet

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

DATA SHEET NO. REV.

EQUIPMENT DATA SHEET 001 A


SHEET OF DATE
INSERT SPU LOGO HERE
NO. BY DATE REVISION 1 1 06/01/22
1 ADA 1/31/22 BY CHK'D PROC. APPR.
ADA ADA
P.O.
Project: TANQUE REQ.
Spec Section:: - Location/Building: Cocina Norte
TAG/EQUIP NO: TD-001 Loop Wiring Diagram: - Manufacturer: TBD
Asset No: - P&ID Sheet: MIG-701 Rep/Phone: -
Name/Type: Tanque de Diésel de Subestación Norte Model: TBD
Service: Diésel Manufacturer: -
Spec Sht 1: - Spec Sht 3: - Rep/Phone: -
Spec Sht 2: - Spec Sht 4: - Model: -

Capacity: 12000 Units: GPM Pressure: Atm Max Atm Min Units: BAR
Connection Size: TBD Units: NA Amb Temperature: 25 Max 31 Min Units: Deg C

ENVIRONMENTAL
MECHANICAL

Connection Type: Flanged Location Occupancy Code: Site Specific Accel:


Size (DIAM X LONG: 365 X 547.5 Units: cm Elevation: 224 Units: cm Seismic Zone: C
Operating Weight: 59629.5 Units: Kg Inside Building: Confined Space Humidity: >80%
Speed (Min/Max RPM): N/A Subject to Flooding: ✘ Direct Sunlight:
Mat'ls of Construction: Acero al Carbono ASTM A283 Gr. C Dusty Area: Corrosive Area:
Accessories Damp W/D Area: ✘ Freezing:
Acero al Carbono ASTM A105
and Spare Parts: Classified Area: Class: I Div: 2 Group: IIA

Electrical Pwr: Standby Pwr: UPS: Type: NA


Voltage: NA Phase: NA Wire: NA Speed(s) (RPM): - HP: -
NEMA Enclosure Type: NA IP Enclosure Type: NA Enclosure: kW:
Continuous Amps: - AIC (kAmps): - NEMA Torque Design Code: Hertz: NA
UL Service Entrance: Main Breaker (AT/AF): - Estimated Starts/Hour: - Efficiency: - Pwr. Fct. -
ELECTRICAL

MOTOR

Rear Access Required: Powered From: - Svc Fctr (Full Speed): - Svc Fctr (VFD): -
Two Exits Required: Est. Heat Release (kW): - ACCESSORIES AND FEATURES
Design Operating Temp: Units: Deg F HVAC Req'd Space Heater: Chem Duty: Cntrl T Box:
Variable Speed Drive: Pulses: AFE: T'Stat: Severe Duty: LR Code:
Harmonic Mitigation: RTD: Inverter Duty: Insl Code:
Special Controls/Relays: - Thermistors: Tropical Duty: Mounting: NA
Accessories Mtr Vib Sw: Bearing Vib Sw:
-
and Spare Parts: Mtr Vib Xmtr: Bearing Vib Xmtr:

Seal Water: Air Supply: Drain: ✘ Process Var: PRESION Sensor Type: MANOMETRO
Painting/Coating: Sistema Tricapa Accuracy: - Ops Range: - Units: PERCENT
SPECIAL REQUIREMENTS

Special O&M, Environmental, or Equipment Specific Information, etc. Repeatability: - Calib Range: - Units: PERCENT
INSTRUMENTATION

Owner Furnished: GC Furnished: Setting: - Units: PSI


Output (mA): NA Voltage: NA
Pneumatic Hydraulic: Input to DCS:
Fieldbus Type: Monitored From:
Wetted Parts Materials: -
Int Safe: Packgd by Mfgr: Dia. Seal:
NEMA Enclosure Type: 4X IP Enclosure Type: 54
ALARMS SETPOINTS
Hi-Hi: - Hi: - Lo: - Lo-Lo: -

Ver Dibujos Anexos


Las bridas son de 150# RF
NOTES
w
N

w
S

&

iS
e
n
o

d
o
o
te
n
e
o
h
e
d

h
e
c
s
s

s
t

t
l

il

(ATTACH CATALOG CUTS AS NECESSARY)


E

A
e

u
a

o
c

c
r

r
t

t
l

PM DNDF I&C SPEC


DIST

PE ELEC MECH ✘ STRUCT


ARQ ESTIMAC PLUMBING ✘ CLIENT 1
CIVIL ✘ HVAC PROCESO ✘ CLIENT 2
'file:///conversion/tmp/activity_task_scratch/574961404.xlsx'#$CDM Template ###

You might also like