A N N U N C I A T O R S

AN-3100D-LC Annunciator
FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM,
PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES

ANNUNCIATOR
The AN-3100D-LC is an
economical LED Display
for remote annunciator
applications. The display
can be connected to
other annunciator logic
systems or can be di-
rectly connected to a PLC
or DCS System.
Compact Size
The annunciator and all
electronics are self con-
tained within a compact frame less than 7"
deep.
AN3100D-LC Ordering Information
Reliability TYPICAL MODEL NUMBER (coded by color)
Every AN-3100D-LC Annunciator is equipped AN3100D-LC -PM -3H -6W -NPB -2 -36 -W -TP
with low power, long life LED’s. The brightness Code Description
exceeds standard incandescent bulbs and they AN3100D-LC AN3100D-LC Alarm Annunciator
last years longer. Mounting Options
PM Semi-Flush Panel Mounting
Flexible Design PC Semi-Flush Panel Mounting with Rear Cover
The window legends are printed on standard RK 19" Rack Mounting (5 Wide Systems Only)
S Surface (Wall) Mounting ( 1H to 5H x 2W to 5W)
transparency film, making it easy to change leg- Number of Cells High – (1-13 H)
ends at any time
Number of Cells Wide – (1-13 W)
Pushbutton Controls
INTB Integral Test Pushbutton
NPB No Integral Pushbutton
FEATURES AND BENEFITS Window Size
4 Quad Size, 4 Inputs Per Cell, Each 1.5"H x 1.5"W
• LED Illumination 3 Third Size, 3 Inputs Per Cell, Each 1.0"H x 3.0"W
2 Half Size, 2 Inputs Per Cell, Each 1.5"H x 3.0"W
• Laser Printed Legends 1 Full Size, 1 Input Per Cell, Each 3.0"H x 3.0"W
IMW Intermixed Window Size (Must Include Matrix)
• Compact Size Number of Active Alarm Points
• Screw Terminal Barrier Block Window Colors
W White Window Filter
R Red Window Filter
A Amber Window Filter
G Green Window Filter
B Blue Window Filter
IMC Intermix Color
Window Legends
TP Legends Printed on Transparency Film (Field Changeable)
ENG Legends Are Engraved on the Window Frames

POWER INSTRUMENTS
A N N U N C I A T O R S

SPECIFICATIONS
INPUT Legends
• Laser printed on transparency film or Panel Mounting Details
Field Contacts, Switched Inputs
Voltage: 24 VDC engraved windows inches (mm)
Current Requirements per Input: Cells Overall Panel Cut-Out
CONNECTIONS H or W H or W H or W
Window # of Switched Input/Output Terminals 1 5.0 (127) 4.06 (103)
Size LED’s Current • Fixed barrier terminal block, 12 GA
(inputs/cell) (per Input) @24VDC (2.5mm) maximum, ring, spade or 2 8.47 (215) 7.53 (191)
bare wire termination
1 8 0.163 A 3 11.94 (303) 11.00 (279)
2 4 0.082 A MECHANICAL 4 15.40 (391) 14.47 (368)
Mounting 5 18.88 (479) 17.94 (456)
3 2 0.041 A • Semi-flush panel mounting
4 2 0.041 A • 19" rack mounting 6 22.34 (568) 21.41 (544)
• Wall (surface) mounting
7 25.81 (656) 24.88 (632)
CONTROLS Weight
• 1.5 lbs per cell (0.34 kg per cell) 8 29.28 (744) 28.34 (720)
Lamp Test
Voltage: 24 VDC 9 32.75 (832) 31.81 (808)
ENVIRONMENT 10 36.22 (920) 35.28 (896)
DISPLAY Operating Temperature Range:
LED • -4 to122OF (-20 to 50OC) 11 39.69 (1008) 38.75 (984)
• White LED, minimum two per Win- Humidity: 12 43.16 (1096) 42.22 (1072)
dow • 20-95% RH
Window Sizes Isolation: 13 46.63 (1184) 45.69 (1161)
• Quad: 1.5"h x 1.5"w (38 x 38mm) • 1950 VDC or 1400 VAC Depth behind panel: 6.75", 10" with rear cover
• Third: 1.0"h x 3.0"w (25 x 76mm) input to case
Example: 2 H x 3 W has a cut-out height of 7.53 (191) and a
• Half: 1.5"h x 3.0"w (38 x 76mm) cut-out width of 11.0 (279)
• Full: 3.0"h x 3.0"w (76 x 76mm)
Window Color
• White, red, amber, yellow, green,
and blue

WIRING DIAGRAM
Input Terminal Ass'y Input Wiring
(Rear View) Customer
Switched Input
TB2 TB1 TB2 TB1
1 1 Input 3 1 - Input 1 1 -
2 2 Input 4 2 - Input 2 2 -
24 VDC 24 VDC
3 3 24 VDC 3 + 24 VDC 3 +
4 4 Lamp Test 4 - Lamp Test 4 -
5 5 5 5

6 6 6 6 Lamp Test
Pushbutton
7 7 7 7

8 8 8 8

POWER INSTRUMENTS

For customer support call:


POWER INSTRUMENTS HEADQUARTERS EUROPEAN HEADQUARTERS ASIA PACIFIC HEADQUARTERS
255 North Union Street AMETEK Power Instruments Unit 15, Lisburn Enterprise Centre 10 Ang Mo Kio Street 65
Rochester, NY 14605 50 Fordham Road Ballinderry Road #05-12 Techpoint
Tel: 585.263.7700 Wilmington, MA 01887 Lisburn, Co Antrim, UK BT282BP Singapore 569059
Fax: 585.454.7805 Tel: 978.988.4903 Tel: 44.28.9260.4100 Tel: 65.484.2388
[email protected] Fax: 978.988.4990 Fax: 44.28.9260.4141 Fax: 65.481.6588
[email protected] [email protected]

ISO 9001 Certified


©2008, by AMETEK, Inc. All rights reserved. 508PDF (210082)