1.0 Earthquake Load Combination: Strength Design

1. This document provides an example of calculating strength design moments and forces for a moment resisting frame under earthquake loading according to NSCP 2015 standards. 2. It calculates the strength design moment at beam end A as 458.15 kN-m or 110.55 kN-m by combining dead, live, and seismic loads according to the specified load combinations. 3. It also calculates the strength design axial load at column top C as 1220.5 kN or -288.0 kN and the moment as 343.5 kN-m or -208.4 kN-m by applying the same load combinations to the column forces and moments.

Uploaded by

Atienza Arjay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views4 pages

1.0 Earthquake Load Combination: Strength Design

1. This document provides an example of calculating strength design moments and forces for a moment resisting frame under earthquake loading according to NSCP 2015 standards. 2. It calculates the strength design moment at beam end A as 458.15 kN-m or 110.55 kN-m by combining dead, live, and seismic loads according to the specified load combinations. 3. It also calculates the strength design axial load at column top C as 1220.5 kN or -288.0 kN and the moment as 343.5 kN-m or -208.4 kN-m by applying the same load combinations to the column forces and moments.

Uploaded by

Atienza Arjay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

1.

0 Earthquake Load Combination: Strength Design

Ex. 1. The example demonstrates the application of the strength design and combinations that
involve the seismic load E given in NSCP 2015, Section 208.5.1.1. This will be done for the
moment resisting frame shown below.

A B C

D
Given:
Zone 4
Cv = 0.40 Ca =0.40
I = 1.5
𝜌 = 1.1
f1 = 0.5

Beam A-B and Column C-D are elements of the special moment-resisting frame. Structure
analysis has provided the following individual beam moments at A, and the column axial loads
and moments at C due to dead load, classroom building live load and lateral and seismic forces.

Dead Load D Live Load L Lateral Seismic Load E


Beam Moment at A 135 kN-m 65 kN-m 165 kN-m
Column C-D Axial Load 400 kN 185kN 480 kN
Column Moment at C 56 kN-m 35kN-m 220 kN-m

Find the following:


1. Strength design moment at beam end A.
2. Strength design axial and moment at column top C.
Calculations:

1. Strength design moment at beam end A.


To determine the strength design moments for design, the earthquake component E must be
combined with the dead and live load components D and L. This process is illustrated below:

a. Determine earthquake load E;

E = 𝜌Eh + Ev
Ev = 0.5 Cv I D
Ev = 0.5(0.40)(1.5)(135)
Ev = 40.5 kN-m

Eh = 165 kN-m

E = 1.1(165) + 40.5
E = 222.0 kN-m

b. Apply earthquake load Combinations

1.2 D + 1.0 E + f1L NSCP 2015 Equation 203-5


0.9 D ± 1.0 E + 1.6H NSCP 2015 Equation 203-7

Using 2015 Equation 203-5 and 203-7, the strength design moments at A for
combination Dead, Live, and seismic forces are determined:

MA = 1.2 MD +1.0 ME + f1L


= 1.2 (135) + 1.0 (222.0) + 0.5 (65)
= 416.5 kN-m

MA = 0.9 MD ± 1.0 ME + 1.6H


= 0.9 (135) + 1.0 (222.0)
=343.5 kN-m
= 0.9 (135) -1.0 (222.0)
= -100.5kN-m
Therefore, MA = 416.5 kN-m or -100.5 kN-m

c. Specific material requirements:


1.32 D ± 1.1 E + 1.1f1L NSCP 2015 Equation 409-4*
0.9 D ± 1.0 E + 1.6H NSCP 2015 Equation 203-7

MA = 1.1 MA
= 1.1(416.5)
= 458.15 kN-m
MA = 1.1(100.5)
=110.55 kN-m
Therefore, MA = 458.15 kN-m for concrete frame.

2. Strength design axial load and moment at column top C:

a. Determine Earthquake load E:

E = 𝜌Eh + Ev
Ev = 0.5 Ca I D
Ev = 0.5(0.4)(1.5)(400)
Ev = 120.0 kN-m

For axial Load:


Eh = 480 kN-m

E = 1.1(480) + 120
E = 648.0 kN-m

For moment:
Ev = 0.5 Ca I D
Ev = 0.5(0.4)(1.5)(56)
Ev = 16.8 kN-m

E = 1.1(220) + 16.8
= 258.8 kN-m

d. Apply earthquake load Combinations

1.2 D + 1.0 E + f1L NSCP 2015 Equation 203-5


0.9 D ± 1.0 E + 1.6H NSCP 2015 Equation 203-7

Using 2015 Equation 203-5 and 203-7, the strength design axial force at C for
combination Dead, Live, and seismic forces are determined:

PC = 1.2 D +1.0 E + f1L


= 1.2 (400) + 1.0 (648) + 0.5 (185)
= 1220.5 kN

Pc = 0.9 D ± 1.0 E + 1.6H


= 0.9 (400) + 1.0 (648)
= 1008 kN
= 0.9 (400) -1.0 (648)
= -288 kN
Therefore, PC = 1220.5 kN or -288.0 kN

For moment:

Mc = 1.2 MD +1.0 ME + f1L


= 1.2 (56) + 1.0 (258.8) + 0.5 (35)
= 343.5 kN-m

MC = 0.9 MD ± 1.0 ME + 1.6H


= 0.9 (56) + 1.0 (258.8)
= 309.3 kN-m
= 0.9 (56) -1.0 (258.8)
= -208.4 kN-m
Therefore, MC = 343.5 kN-m or -208.4 kN-m

e. Specific material requirements:

Reinforced concrete: The axial force Pc and the Mc must be multiplied by 1.1 as per
NSCP 2015 203.3.1.