Arc Dpwcs User Manual

This document provides an overview of the Distributed Power Wireless Control System (DPWCS) used on Indian Railways' electric locomotives. The DPWCS allows locomotives to be distributed throughout long trains and controlled wirelessly from a master locomotive. The key components of the DPWCS include the Control and Communication Unit (CCU), Brake Interface Unit (BIU), Driver Interface Unit (DIU), and Pressure Sensor Unit. These components are located in various areas of the locomotive and connected via different communication mediums. The CCU implements the DPWCS logic and connects to other units via radio, MVB, and serial connections. The DIU provides driver commands and status displays. The BIU interfaces with the locomotive bra

Uploaded by

Ramudu Appala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
325 views38 pages

Arc Dpwcs User Manual

This document provides an overview of the Distributed Power Wireless Control System (DPWCS) used on Indian Railways' electric locomotives. The DPWCS allows locomotives to be distributed throughout long trains and controlled wirelessly from a master locomotive. The key components of the DPWCS include the Control and Communication Unit (CCU), Brake Interface Unit (BIU), Driver Interface Unit (DIU), and Pressure Sensor Unit. These components are located in various areas of the locomotive and connected via different communication mediums. The CCU implements the DPWCS logic and connects to other units via radio, MVB, and serial connections. The DIU provides driver commands and status displays. The BIU interfaces with the locomotive bra

Uploaded by

Ramudu Appala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 38

DISTRIBUTED POWER WIRELESS CONTROL SYSTEM

ARC/DPWCS/V3.0
USER MANUAL

January 2018

RELEASE 1.0

Advanced Rail Controls Private Limited


Bangalore-560092
INDEX
INDEX NO. CONTENTS PAGE NO.
1.0 Introduction 1
2.0 DPWCS Equipment deposition 2
3.0 Location of DPWCS equipment’s in Loco 3
3.1 DPWCS connection diagram 3
3.2 Equipment Level interconnection 4
4.0 Equipment level Explanation 4
4.1 Control & Communication Unit (CCU) 4
4.1.1 Mechanical Design details of CCU 4
4.1.2 Interface details of CCU 5
4.2 Brake Interface Unit (BIU) 6
4.2.1 Mechanical Design details of BIU 6
4.2.2 Interface details of BIU 7
4.3 Driver Interface Unit (DIU) 7
4.3.1 Mechanical Design details of DIU 8
4.3.2 Interface details of DIU 8
4.3.3 Operator controls of DIU 9
4.3.4 Individual keypad details PXY key pad 9
4.3.5 DPWCS Functional keypad 10
4.3.6 DDU Functional keypad 10
4.3.7 DPWCS Numerical keypad 10
5.0 DIU Screens 11
5.1 DDU mode 12
5.2 Password Screen 13
5.3 Self-test Screen 14
5.4 Zone selection Screen 14
5.5 Inauguration Screen 15
5.6 Master Screen 15
5.6.1 Wagon entry Screen -1 16
5.6.2 Wagon entry Screen -2 17
5.6.3 Wagon entry confirmation Screen 17
5.7 Inauguration Screen in master 18
5.8 Master Loco Home Screen 22
5.9 Inauguration Screen in slave 24
5.9.1 Slave Loco Home Screen 25
5.10 Screens in Master 26
5.10.1 Modes 26
5.10.2 Reboot 27
5.10.3 IND, IDLE, BRAKE, ISO, BK-OUT modes 28
5.10.4 Independent mode 29
6.0 Inauguration Procedures 30
7.0 System Fault Diagnose 31
8.0 Spare Items & Accessories 32
9.0 Contact Details 35
IMPORTANT NOTICE
This is a sophisticated microprocessor based equipment and can be serviced only by trained
skilled personnel. Opening the equipment by any unauthorized person will make the warranty
null and void

1.0 INTRODUCTION
This document describes the technical details of Distributed Power Wireless Control System (DPWCS) used
in 3-Phase Electric Locomotives [of WAG9, WAG9H, WAP7 & WAP5 classes] being operated by Indian
Railways. The DPWCS System is designed to increase the throughput of the railway line tremendously
without much additional input. DPWCS operation enables heavy haul with minimum coupler forces. Under
DPWCS scheme, locomotives are distributed at different points in a long train and controlled through
wireless from the master, and slave locomotive crew can be eliminated, if desired.
DPWCS complete system consists:
1. Control & Communication Unit (CCU)
2. Brake Interface Unit (BIU)
3. Driver Interface unit (DIU)
4. Pressure Sensor Unit (PSU)

Glossary

Abbreviation Comment
CCU Control and Communication Unit
BIU Brake Interface Unit
DIU Driver Interface Unit
VCU Vehicle Control Unit
RIB Relay Interface Board
LED Light Emitting Diode
PSB Power Supply Board
CB Controller Board
VCU Vehicle Control Unit

DPWCS USER MANUAL V3.0 -1-


2.0 DPWCS EQUIPMENT DIPOSITION

SL.No. Name of the Equipment Qty per Location Function


Loco
1 Control & 1 Machine room Implements DPWCS logic.
Communication Unit Connected to Radio, VCU
(CCU) through MVB, DIU and BIU
2 Brake Interface Unit 2 CAB, below A9 Provides Loco Brake and Auto
(BIU) brake control Brake functions through E70 in
the slavelocomotives.
Connected to CCU and
Faiveley’s E70 Brake system &
Auto Brake controller in cab

3 Driver’s Interface Unit 2 CAB Implements Driver’s Commands


(DIU) & Status Indication. Connected
to MVB.
4 GPS Receiver 2 Roof Provides the GPS coordinates
of the current location of the
locomotive. Connected to DIU.
5 Antenna 2 Roof Transmission of telemetry &
tele-command data from master
to slaves and vice-versa.
Connected to Radio through coaxial
cable.
6 Pressure Sensor Unit 1 CAB Measures MR, BC1, BC2, BP,
(having 6 F P Pressure and A F.
transducers) connected to CCU.

7 MVB Star Coupler PCB 2 VCU1/VCU2 Providing MVB connectivity to


(inserted in CCU and DIU.
Slot V of VCU1 & VCU2)
8 MCB 1 SB2 ON/OFF control of 110V DC
power to the DPWCS

DPWCS USER MANUAL V3.0 -2-


3.0 LOCATION OF DPWCS EQUIPMENTS IN THE LOCOMOTIVE

3.1 DPWCS EQUIPMENT CONNECTION DIAGRAM

V V

VCU-1 VCU-2

MVB ELECTRICAL
MVB ELECTRICAL

RS-485 DIU-1 BUZZER RS-485 DIU-2 BUZZER


GPS GPS
MVB OPTICAL

TO BLKEY FOR TO BLKEY FOR


LOCO RESTART BIU-1 SERIAL OGF SERIAL OGF BIU-2 LOCO RESTART
CCU
TO MARKER
TO MARKER LIGHT
LIGHT

4-20mA x 6 channels
A9 CONTROLLER- A9 CONTROLLER-
CAB1 E70 PSU CAB2 E70

DPWCS USER MANUAL V3.0 -3-


3.2 EQUIPMENT LEVEL INTERCONNECTION
The data inter-connection between various modules of DPWCS and the locomotive system is illustrated
above. The CCU communicates with VCU-2 through MVB optical medium. The BIU (1/2) communicates
with CCU (1/2) through asynchronous serial communication using optical medium. The DIU (1/2)
communicates with VCU (1/2) through electrical MVB, as existing in the present locomotives. The GPS
receiver module is intelligent and communicates with DIU (1/2) through RS-485 medium. Buzzer is
connected to each DIU, which is enabled the connection between E70 brake system and BIU comprises
analog and digital signals. The analog signals are for brake reference, and digital signals, which are at 110V
DC, represents different brake positions like release, run, service, initial application etc. obtained through
CAM switches. To operate marker light and Loco restart logic, respective CAB BIU’s connected to their
respective loco connections.

4.0 EQUIPMENT LEVEL EXPLANATION


4.1 CONTROL AND COMMUNICATION UNIT
The architecture of Control & Communication Unit (CCU) is comprises of a microcontroller and is
responsible for carrying out various DPWCS related tasks. Attached with the microcontroller is MVB
interface board. The MVB interface board provides connectivity to VCU over optical MVB. The
microcontroller is interfaced with BIU1 and BIU2 over asynchronous optical fibre bus. The radio is
interfaced with the microcontroller through serial RS-232 bus. The dipole antenna connection is using
coaxial cable. The antenna is mounted on roof-top above the cab portion. Power supply to microcontroller
is at 5V DC and to the radio is 12V DC, which are derived from 110V DC Loco battery using DC-DC
converters.

4.1.1 MECHANICAL DESIGN DETAILS OF CCU

DPWCS USER MANUAL V3.0 -4-


4.1.2 INTERFACE DETAILS OF CCU

Sl. No Interface Details Connector Type

1 Pressure Sensor 19 pin Circular Male connector

2 MVB M20 x 1.5 Metal Gland to pass


Optical cable

3 BIU1 M20 x 1.5 Metal Gland to pass


Optical cable

4 BIU2 M20 x 1.5 Metal Gland to pass


Optical cable

5 Ext.Fan 3 pin Circular Female connector

6 Power supply 110V DC 3 pin Circular Male connector

7 RS-485 CH1 9 pin D-SUB Male connector

8 RS-485 CH2 9 pin D-SUB Male connector

9 Service Port for Radio 9 pin D-SUB Female connector

10 Ethernet M12 circular connector

11 Service Port for Debug 15 pin D-SUB Male connector

12 Antenna-1 M32 X 1.5 metal gland to pass


UHF Radio co-axial cable

13 Antenna-2 M32 X 1.5 metal gland to pass


UHF Radio co-axial cable

DPWCS USER MANUAL V3.0 -5-


4.2 BRAKE INTERFACE UNIT
Brake Interface Unit interfaces the Faiveley E70 Brake Control system or Knorr Bremse CCB with DPWCS.
It has micro-controller unit for carrying out various tasks. The signals from A9 controller are routed
through the BIU using changeover switches. It has two modes viz. Master & Slave. When the locomotive
works as Master, the changeover switches are thrown to A9 controller side so that the signals from A9
controller (potentiometer value referring to brake pipe pressure reference & 110V digital signals
corresponding to handle position viz. release, run, initial application, full service and emergency) are
connected directly to the E70 controller. Further, during Master mode, the BIU will be able to read both
analog values and digital signals. The read values are sent to the slave over wireless for duplication in a
similar way. In the slave loco, the BP pressure reference and A9 controller positions are received from
Master over radio. The changeover switches in the BIU are switched to Slave mode, so that, A9 controller
is isolated and the values are generated and injected by BIU into E70 controller. As the reference values
are received from the master, the Slave will generate same braking effort and same braking conditions as
that of master. BIU can cut off the BP valve in slave loco (to make the slave loco work as a wagon in the
train - during radio signal loss conditions). In case of Knorr bremse brake controller, RS-485 signals will be
connected to LON to RS-485 Interface box through CCU. BIU also implements the logic for remote loco
restart. In case of any incipient problems with the slave loco, there may arise a need to restart the slave
loco remotely from master. By activating the restart command from the DIU, remote loco gets re-started.
For achieving this, the cab activating key (BL key) is interfaced with the BIU. When the loco is selected as
Slave, the red marker light will automatically become ON. For this purpose, the red marker circuit is
interfaced with BIU.

4.2.1 MECHANICAL DESIGN DETAILS OF BIU


cer box

DPWCS USER MANUAL V3.0 -6-


4.2.2 INTERFACE DETAILS OF BIU

Sl. No Interface Details Connector Type


19 pin Circular Male connector (In
1 Brake Input
case of Faiveley E70 brake system)

2 Serial Port 1 M20 x 1.5 Gland to pass Optical


cable

3 Serial Port 2 M20 x 1.5 Gland to pass Optical


cable

4 Brake Output 19 pin Circular Female connector


(In case of Faiveley E70 brake
system)

5 Digital Output 10 pin Circular Female connector

6 Power supply 110V DC 3 pin Circular Male connector

7 Service Port for program 9 pin D-SUB Male connector

8 Service Port for Debug 9 pin D-SUB Female connector

4.3 DRIVER INTERFACE UNIT


The DIU is one of the key elements of DPWCS, as most of the operations can be carried out
through DIU by the Driver. The DIU is designed in such a way that the same equipment can be
used either in DPWCS fitted locomotives or in normal locomotives, by suitably selecting the mode
of operation by the driver.

DPWCS USER MANUAL V3.0 -7-


4.3.1 MECHANICAL DESIGN DETAILS OF DIU

4.3.2 INTERFACE DETAILS OF DIU

Sl. No Interface Details Connector Type


USB 2.0 PORT A
1 USB

2 KBD PS/2 Male

3 DDA 9 pin D-SUB Female connector

4 Buzzer 6 pin circular Male Connector

5 MVB 10 pin Circular Male connector

6 GPS 10 pin Circular Female connector

7 Ext.Fan 3 pin Circular Female connector

8 Power supply 110V DC 3pin Circular Male connector

DPWCS USER MANUAL V3.0 -8-


4.3.3 OPERATOR CONTROLS OF DIU

DDU
FUNCTIONAL PXY KEY
KEYPAD PAD

DPWCS
DPWCS
NUMERIC
FUNCTIONAL
KEYPAD
KEYPAD

The DPWCS has a rugged membrane keyboard on the right-hand side and left-hand side. These keys are
known as “PXY” keypad, “DPWCS Functional” keypad on the right-hand side, “DDU Functional “keypad
and “DPWCS Numeric” keypad on the left-hand side. The “PXY” keypad has 6 keys, each assigned to a
separate function, and the “DPWCS Functional” keypad has 9 keys, each assigned to a separate function. The
“DDU Functional” keypad has 6 keys, each assigned to a separate function and the “DPWCS NUMERIC”
keypad has 10 keys, each assigned to a separate numeric function.

4.3.4 INDIVIDUAL KEYPAD DETAILS: PXY KEY PAD


The PXY keypad has 06 membrane keys of rugged type. The keys
are protected from direct ingress of dust and moisture. The keys are suitable for operation by fingers.
The function assigned to each key is given below:

PXY CLEAR PXY UP

PXY HOME PXY DOWN

PXY BRIGHTNESS PXY ENTER

DPWCS USER MANUAL V3.0 -9-


4.3.5 INDIVIDUAL KEYPAD DETAILS: DPWCS FUNCTIONAL PAD
The DPWCS Functional keypad has 09 membrane keys of rugged type. The keys
are protected from direct ingress of dust and moisture. The keys are suitable for operation by fingers.
The function assigned to each key is given below:

MODES NEUTRAL SECTION

RE-BOOT PANTO LOWERING

MENU EMERGENCY

UP DOWN

ENTER

4.3.6 INDIVIDUAL KEYPAD DETAILS: DDU FUNCTIONAL KEYPAD


The DDU Functional keypad has 06 membrane keys of rugged type. The keys
are protected from direct ingress of dust and moisture. The keys are suitable for operation by fingers. The
function assigned to each key is given below:

DDU ESC DDU UP

DDU HOME DDU DOWN

DDU MENU DDU ENTER

4.3.7 INDIVIDUAL KEYPAD DETAILS: DPWCS NUMERICAL KEYPAD


The DPWCS Numerical keypad has 10 membrane keys of rugged type. The keys
are protected from direct ingress of dust and moisture. The keys are suitable for operation by fingers. The
function assigned to each key is given below: (0-9).

DPWCS USER MANUAL V3.0 - 10 -


5 DIU SCREENS

Above screen is the first screen in DIU (Driver Interface Unit) of DPWCS. This screen provides an
option to select two modes viz. DPWCS Mode and DDU Mode. ‘DPWCS mode’ key enables the process of
Radio remote control operations starting from password entry, inauguration process and displaying
various parameters/data of all the locos connected in the DPWCS configured train. ‘DDU mode’ key
enables normal loco operations displaying all the data of respective loco.

‘OK’ key confirms the Mode selection and the ‘Cancel’ key de-select the selected mode and gives
one more chance to select the mode.

DPWCS USER MANUAL V3.0 - 11 -


5.1 DDU MODE:

Note: All the DDU mode operations are explained in the ‘driver’s manual for DDU unit for three phase
locomotives‘

The only difference is that instead of external keys, soft keys (on touch panel) are provided on the
display for navigation to different screens and pixy operation.

DPWCS USER MANUAL V3.0 - 12 -


5.2 Password screen

A 5-digit password has to be stored in the flash of the system. And entered password should match
the stored password for further operation in RRC mode. After typing the password press “ “ key to
confirm. If the password entered exceeds 5 digit a message should pop-up “Password Cannot Exceed 5
Digit” and if the password entered is wrong another message should pop up “Wrong Password Entered,
Press ‘C’ and re-renter the Password”.

Once the password entered matches with the password stored next DPWCS screen will appear on
the display.

DPWCS USER MANUAL V3.0 - 13 -


5.3 Self-test screen
Below screen shows the healthiness of the system.

5.4 Zone Selection Screen

Different zone is having different range of frequency so press the zone to set desired frequency. The
default frequency is 406.6MHz.

DPWCS USER MANUAL V3.0 - 14 -


5.5 Inauguration Screen:

This is the first screen in the DPWCS mode which gives the option to select the loco as either
master or slave. Select Master/Slave and then press ‘OK’ to confirm. Else press ‘CANCEL’ to re-select.

5.6 Master screen -1:

DPWCS USER MANUAL V3.0 - 15 -


Once a loco is selected as master it starts searching for the slave locos. This screen displays all
near slaves. Driver should select slave locos which are connected to same train. Once the slave is
selected, selected slave loco no’s are displayed for confirmation. Press ‘OK’ if the selected slave
loco no’s are correct else ‘CANCEL’ to re-select.

5.6.1 Wagon Entry screen -1:


In this screen Total train length is calculated. For that type of wagon and no. of wagons has to be entered.
At first the data entered will be for Master to first slave (Slave-1).

1. Select any one type of wagon (BOXN, BOB-N, N-BOY, TBT etc) and enter the no. of wagons. And
press “ ” key. Press or key to see the remaining type of wagons.
2. If more than one type of wagon needs to be entered, select another type and follow step ‘1’.
3. After entering all the data of wagons between master and first slave press ‘Enter’.
This screen will also shows the information of No. of wagons entered and the total train length.

DPWCS USER MANUAL V3.0 - 16 -


5.6.2 Wagon Entry screen -2:

After entering wagons press Enter then above screen will appear, asking “Train Has One more
Slave..?” with options ‘YES’ and ‘NO’ keys. If no more slaves press No and press OK for next screen or
press YES to re-enter wagons of one more slave.

5.6.3 Wagon Entry Confirmation Screen:

DPWCS USER MANUAL V3.0 - 17 -


This screen displays total no. of wagons and total length between master and slave and between each
slave. If the entered data is wrong press “BACK” key to go to Wagon Entry Screen -1 to re-enter the wagon
information data. Else press “ENTER” key to go to Inauguration screen.

5.7 Inauguration Screens in master


Inauguration starts by checking the communication. Once the communication with all system is
established ‘BP drop check’ process starts. Once inauguration process is completed status of all the locos
are displayed on the screen.

Inauguration Screen -1

Inauguration screen -1 shows the status of communication check between master and slave locos. Once
the communication is established between all the system ‘BP drop check’ is initialized. This is displayed in
Inauguration screen -2. BP drop is done in the last slave of the train and the drop in BP has to be seen in
all the other slaves and the master. Inauguration screen -3 shows the BP continuity status and the actual
BP value of all the locos. If BP continuity is obtained in all the locos than status message, “BP Continuity
OK” will be displayed in front of respective slaves and the master.

DPWCS USER MANUAL V3.0 - 18 -


Inauguration Screen -2

Inauguration Screen -3

DPWCS USER MANUAL V3.0 - 19 -


Inauguration Screen -4
If a wrong slave is selected during the inauguration process then BP continuity check will be
failed. When there is no BP continuity a status message “BP Continuity FAILED” is displayed in-front of
the wrongly selected slave.

RADIO REMOTE CONTROL


MASTER LOCO
BP CONTINUITY CHECKING…..

Master 3. BP Continuity OK
BP
Slave -1 3. BP Continuity OK
BP
Slave -2 5. BP Continuity FAILED
BP
Slave -3 3. BP Continuity OK
BP 5
Slave -4 3. Dropping BP from Last
BP Slave
Monitor BP Status for Verification

Inauguration Screen -5

DPWCS USER MANUAL V3.0 - 20 -


Inauguration screen -5 displays the status message “Inauguration Fail” when BP continuity check fails
telling driver to re-inaugurate. And the Inauguration screen -6 shows successful inauguration message
(“Inauguration Successful”) indicating inauguration process is completed.

Inauguration Screen -6

DPWCS USER MANUAL V3.0 - 21 -


5.8 Master Loco Home screen:

This is the Home screen for Master Loco which displays the status of all the slave locos connected and
also the status of master. Other than this it also displays the fault message of slave locos. Home screen
has other options viz. MODES, REBOOT, NEUTRAL SECTION, PANTO LOW, MENU. And an enter key to
confirm the selected option.

This indicates the full radio signal strength

This indicates the medium radio signal strength

This indicates the Low radio signal strength

Status/Fault This box shows the status of the key pressed/fault messages/ or the
error message of the RRC system and also the sanding valve status.

DPWCS USER MANUAL V3.0 - 22 -


Slave Loco:

Once the loco is selected as slave loco we need to select the position of that loco in the train from SLAVE
– 1 to SLAVE – 4. After selecting the position of the loco in the train press ‘OK’ to confirm and press
‘CANCEL’ to re-select the position of the loco in the train.

DPWCS USER MANUAL V3.0 - 23 -


5.9 Inauguration Screens in SLAVE:

DPWCS USER MANUAL V3.0 - 24 -


5.9.1 Slave Loco Home Screen:
After successful inauguration this will be the home screen for slave loco.

DPWCS USER MANUAL V3.0 - 25 -


5.10 Screens in Master:
5.10.1 Modes

SYN Master Slave-1 Slave-2 Slave-3 Slave – 4 MODES

Loco No 31282 31284 31022 SYNC


Node 596 596 596
IND
Panto Up Up Up

VCB On On On BRAKE

TE/BE 25 20 23
IDLE
Speed 5 5 5
ISO
MR/FP 8.2/6 8.7/6 8.9/6

BP 5.1 5.0 5.0 Bk-OUT


BC1/BC2 0.0/0.0 0.0/0.0 0.0/0.0
Ente
Parking B 6.2 6.1 6.1

Airflow 6.0 6.0 6.0 HOME

Status message / Fault message of slaves/ sanding valve status Status/Fault

Main Menu: Loco No 31284


>1. Vehicle Diagnostics
Hom CLR Ente
2. Information Train Bus
e r
3. Process Information

DPWCS USER MANUAL V3.0 - 26 -


5.10.2 Reboot:

SYN Master Slave-1 Slave-2 Slave-3 Slave - 4 Reboot

Loco No 31282 31284 31022


System
Node 596 596 596

Panto Up Up Up Loco

VCB On On On

TE/BE 25 20 23

Speed 5 5 5

MR/FP 8.2/6 8.7/6 8.9/6 ESC


BP 5.1 5.0 5.0
Enter
BC1/BC2 0.0/0.0 0.0/0.0 0.0/0.0

Parking B 6.2 6.1 6.1


HOME
Airflow 6.0 6.0 6.0

Status message / Fault message of slaves/ sanding valve status Status/Fault

Main Menu: Loco No 31284


>1. Vehicle Diagnostics
Hom CLR Ente
2. Information Train Bus
e r
3. Process Information

DPWCS USER MANUAL V3.0 - 27 -


5.10.3 IND, IDLE, BRAKE, ISO, BK-OUT Modes

SYN Master Slave-1 Slave-2 Slave-3 Slave – 4 IND -MODE

Loco No 31282 31284 31022 Slave-1


Node 596 596 596
Slave-2
Panto Up Up Up
VCB On On On Slave-3

TE/BE 25 20 23 Slave - 4
Speed 5 5 5
ALL
MR/FP 8.2/6 8.7/6 8.9/6
ESC
BP 5.1 5.0 5.0
BC1/BC2 0.0/0.0 0.0/0.0 0.0/0.0 Enter
Parking B 6.2 6.1 6.1
HOME
Airflow 6.0 6.0 6.0

Status message / Fault message of slaves/ sanding valve status Status/Fault

Independent
Slave Loco Mode
Fault:
Main Menu: Loco No 31284
>1. Vehicle Diagnostics
In the independent modeTrain
selected Hom in redEnte
CLR
2. Information Bus independent loco parameters are displayed box
e r
indicating that the selected
3. Process slave loco will work independently. And the Panto and VCB of the
Information
loco can be independently controlled by the keys given the below screen.

DPWCS USER MANUAL V3.0 - 28 -


5.10.4 Independent Mode
In the independent mode selected independent loco parameters are displayed in red box indicating that
the selected slave loco will work independently. And the Panto and VCB of the loco can be independently
controlled by the keys given the below screen.

SYN Master Slave-1 Slave-2 Slave-3 Slave – 4 IND -MODE

Loco No 31282 31284 31022 Panto UP


Node 596 596 596

Panto Up Up Up Panto Dn

VCB On On On
VCB On
TE/BE 25 20 23
Speed 5 5 5 VCB Of
MR/FP 8.2/6 8.7/6 8.9/6
ESC
BP 5.1 5.0 5.0
BC1/BC2 0.0/0.0 0.0/0.0 0.0/0.0 Enter
Parking B 6.2 6.1 6.1
Status message6.0
Airflow / Fault message6.0
of slaves/ 6.0 HOME

Status
Statusmessage
message //Fault
Faultmessage
message of
ofslaves/
slaves/ sanding valve status Status/Fault
Status/Fault

Slave Loco Fault:


Main Menu: Loco No 31284
>1. Vehicle Diagnostics
Hom CLR Ente
2. Information Train Bus
e r
3. Process Information

DPWCS USER MANUAL V3.0 - 29 -


6.0 Inauguration Procedures

Slave Procedure
1. Go to the trail locomotive and make the brake configuration of locomotive as lead
loco.
2. Release the loco brake from both the cab (1&2).
3. Switch ON the DPWCS system MCB.
4. Put the BL Key to D position.
5. Wait for the NODE to become 504.
6. After NODE reaches 504 Press DPWCS MODE in DIU.
7. Enter Password and press OK.
8. Select zone if applicable or press default zone.
9. Self test screen shows the healthiness of the system.
10. Initial stage failure of system is shown in DIU.
11. Successful Self test brings the Master or Slave selection screen.
12. Press Slave and Press OK to continue.
13. Select the slave position from slave one to slave four.
14. Put the BL Key in OFF position and remove.
15. Procedure 1 to 14 is common for all slave locomotives.

Master Procedure
16. Switch ON the DPWCS system MCB.
17. Put the BL Key to D position.
18. Wait for the NODE to become 504.
19. After NODE reaches 504 Press DPWCS MODE in DIU.
20. Enter Password and press OK.
21. Select zone if applicable or press default zone.
22. Self- test screen shows the healthiness of the system.
23. Initial stage failure of system is shown in DIU.
24. Successful Self- test brings the Master or Slave selection screen.
25. Press Master and Press OK to continue.
26. Select the Slave loco by pressing slave loco number displayed on DIU.
27. Enter the wagons between the Master and respective slave locos.
28. Verify the calculated train length and number of wagons.
29. After verifying the Train length and number of wagons communication established
screen will appear.
30. Raise the Panto and Close the VCB by giving driver command.

DPWCS USER MANUAL V3.0 - 30 -


31. BP starts increasing up to 4.8kg in all locos that is master and slaves.
32. If BP fails to increase up to 4.8kg then check the drop of pressure between the
locomotives.
33. Once BP increases to 4.8kg in all locos then BP drop test is carried out automatically.
34. Successful BP drop test results DPWCS home screen in all locos.
35. Wrong slave selection or failure of continuity results BP test failure screen.

7.0 System Fault Diagnose


DPWCS system having self-diagnose feature based on that we can find the exact reason
behind the problem. After power ON MCB, DPWCS system checks its healthiness and result of self-test is
displayed on driver interface unit. Self-test screen will dis appear if all system working fine or it struck on
self-test screen itself.

Self-test screen

DPWCS USER MANUAL V3.0 - 31 -


SELF TEST INCLUDED
1. Radio test.
2. Control Communication Unit test.
3. Driver interface unit MVB test
4. Brake Interface Unit 1 test.
5. Brake Interface Unit 2 test.
6. Pressure sensor test.

8.0 SPARE ITEMS & ACCESSORIES

DRIVER INTERFACE UNIT (DIU)

SL.No. Item name UID NUMBER Quantity /unit

1 Processor board, 800 MHz 1122131001 One

2 10.4” TFT Display with in-built touch 1113141103 One


screen (P-CAP) 800 X 600

3 Power supply Board (70V DC to 331013160Q One


137.5 V DC nominal 110V DC,
protection against surge and short
circuit)

4 MVB Controller Board with ESD+ 331013100A One


physical medium

5 12V DC Fan small 1115121101 One

6 12V DC Fan big 1115121501

7 14 keys membrane key board 2220111206 One

8 3 pin Circular Connector Male 111215230C One

7 3 pin Circular Connector Female 111215230E One

8 10 pin Circular Connector Male 1112152335 One

9 10 pin Circular Connector Female 111215230D One

10 6 pin Circular Connector Male 11121523DS One

DPWCS USER MANUAL V3.0 - 32 -


11 9 pin Sub-D Connector Female with 2212151699 One
coding plate

11 Fully assembled Buzzer unit 331013100T One

12 Fully assembled GPS box 331013100S One

13 Hybrid MVB bus coupler card 3310131018 One

CONTROL & COMMUNICATION UNIT (CCU)

SL.No. Item name UID NUMBER Quantity /unit

1 ARM Controller Board 331013101B One

2 UHF Radio 1127141102 One

3 Antenna 1110111203 Two

4 Co-axial cable- 10m 1112103027 Two

5 Power supply Board (70V DC to One


331013101P
137.5 V DC nominal 110V DC, /
protection against surge and short 331013101S
circuit)

6 MVB Controller Board 331013101E One

7 12V DC Fan Small 1115121101 One

8 12V DC Fan Big 1115121501 One

9 3 pin Circular Connector Male 111215230C One

10 3 pin Circular Connector Female 111215230E One

11 19 pin Circular Connector Male 11121523CG Two

12 9 pin Sub-D Connector Male with 2212151671 Two


coding plate

13 9 pin Sub-D Connector Female 111215235R One

14 15 pin Sub-D Connector Male 1112151582 One

15 M12 Connector 111215237N One

16 M20 X 1.5 Metal Gland 2216112521 Three

DPWCS USER MANUAL V3.0 - 33 -


17 M32 x 1.5 Metal Gland 2216112603 Two

18 Pressure sensor Unit (6 sensors) 2228111811 One

BRAKE INTERFACE UNIT (BIU)

SL.No. Item name UID NUMBER Quantity /Unit

1 ARM Controller Board 331013101D One

2 Relay Interface Board 331013100Y One

3 Power supply Board (70V DC to 331013101P One


137.5 V DC nominal 110V DC, /
protection against surge and short 331013101S
circuit)

4 12V DC Fan Small 1115121101 One

5 3 pin Circular Connector Male 111215230C One

6 19 pin Circular Connector Male 22121523CP One

7 19 pin Circular Connector Female 22121523CQ One

8 M20 X 1.5 Metal Gland 2216112521 Two

9 9 pin Sub-D Connector Male 111215235R One

10 9 pin Sub-D Connector Female 11121523CW One

11 10 pin Circular Connector Female 111215230D One

DPWCS USER MANUAL V3.0 - 34 -


9.0 CONTACT DETAILS:

For any warranty/service related queries, please contact:

Bangalore HQ : Royapuram / Erode / Kalyan / Vadodara sheds

Mr.M.Mariappa,
Head, Service Department,
Advanced Rail Controls Private Limited,
# 59/1&2, Above Bank of India,
G-Block, Sahakaranagar,
Bangalore-560 092
Phone : +91 80 42401212, +91 80 42401226
Fax: +91 80 42401213
Cell : + 91 9743715600
E-Mail: <[email protected]>, <[email protected]>
URL : <www.arc.net.in>

Lallaguda / Vishakhapatnam / Kazipet / Vijayawada

Bharadwaj K.S [Base Station : Lallaguda]


Cell : + 91 9553776172

CLW / Dankuni

Rahul Deo Sharma [Base Station : Chittaranjan]


Cell : + 91 9334804107

Piyush Prasad [Base Station : Chittaranjan]


Cell : + 91 9386203249

Ajni / Itarsi / Bhusawal / Bhopal / New Katni

Pankaj Rameshrao Hedau [Base Station : Nagpur]


Cell : + 91 9021090829

Ghaziabad / Tuglakabad / RDSO

DPWCS USER MANUAL V3.0 - 35 -


Subhash [Base Station : New Delhi]
Cell : + 91 9212846380

Tatanagar / Bandamunda

Vivek Kumar Mukhi [Base Station : Tatanagar]


Cell : + 91 7762905971

Gomoh / Howrah / Kancharapara

Ravikumar Vishwakarma [Base Station : Gomoh]


Cell : + 91 7050029319

DPWCS USER MANUAL V3.0 - 36 -