170mm DEEP PRESTRESSED CONCRETE BLOCK & BEAM S/S SLAB (With Uniformly Distributed loads ONLY)

Design Conditions: Ultimate Moment of Ultimate Shear


Ribs: 150mm WIDE x 60mm DEEP @ 560mm Centres
Resistance Mu (106) Resistance Vu
Prestressing Wires: 4.0mm Diameter. Nominal Tensile Strength = 1750MPa
Blocks: 410mm LONG x 200mm WIDE x 120mm DEEP (15kg) kNm/1000mm kN/1000mm
Topping: 50mm Minimum. (fcu = 25MPa)
28.47 23.73
Screed: 30mm Max.
In-situ Concrete = 0.0711m3/m2 (Incl. 200mm wide stiffening ribs @ 1.6m c/c Max.)
S.D.L = 4.078kN/m run /m width (Includes self weight of slab, screed, tiles etc) DATE: 10.07.2014

Maximum Service Live loads ( Qk )in kN/m2 for given Spans


Spans (m)
2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400
8.35 7.54 6.83 6.21 5.67 5.18 4.75 4.36 4.00 3.68 3.39 3.12 2.64 2.21 1.82 1.48 1.17 0.90 0.64 0.42

Qk Service Live Loads in kN/m2 - based on Ultimate moment

18.00 15.10 12.76 10.84 9.26 7.93 6.80 5.84 5.01 4.29 3.67 3.12 2.64 2.21 1.82 1.48 1.17 0.90 0.64 0.42

Qk Sevice Live Loads in kN/m2 - based on Ultimate Shear Resistance

8.35 7.54 6.83 6.21 5.67 5.18 4.75 4.36 4.00 3.68 3.39 3.12 2.87 2.65 2.43 2.24 2.06 1.88 1.73 1.58

Qk Service Live loadsin kN/m2- based on maximum Allowable Deflection ( Ec=26000N/mm2)

59.75 47.23 37.83 30.63 25.03 20.60 17.06 14.19 11.84 9.90 8.28 6.92 5.77 4.79 3.95 3.23 2.60 2.05 1.57 1.15

Allowable Short Term Deflection = Span/250 mm


10.4 11.2 12 12.8 13.6 14.4 15.2 16 16.8 17.6 18.4 19.2 20 20.8 21.6 22.4 23.2 24 24.8 25.6
NOTE:
1. Any unusual imposed line loads on the slab would need to be designed for by the Engineer as a 'non-standard' load case
2. Any unusual imposed point loads on the slab would need to be designed for by the Engineer as a 'non-standard' load case