DTS Gcom500 GSM Gate Controller: Operating Instruction Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DTS Gcom500

GSM Gate controller


Operating Instruction Manual

DTS SECURITY
P.O.BOX 3399
EDENVALE
1610

TELEPHONE 086 1000 387


BaseSpartan +2711 392
plate-mounting 5540 (H/O)
instructions
Pretoria +2712 361 5528
Alberton +2711 907 8846
Natal +2731 916 4002

www.dtssecurity.co.za
E-EEEE

1
How to start using your Gcom500
Connect the Gcom500 to your required appliance (eg: gate motor or Alarm system)
Obtain your sim card cell number
Insert your cell phone sim card into the Gcom500
Purchase air time for the inserted sim card (approximately R50.00)
Power up the Gcom500 (LED will come on)
Wait for the LED to start flashing slowly.
Gcom500 is now connected to the network and ready to be used.

Gcom500 SMS Programming Codes


Default Administration Password (P/W) = 123456 (Can be changed to Alpha Numerical) (See note 2 below)
Default for Operator PIN = 999999
Max tel. number size = 16 Digits (Use international format e.g. +27831231234)
Note that the last character of the SMS must always finish with a “;” (semi-colon)
Parameter Settings Table
PGM Parameter Admin P Code Data Default
Change Admin default Password (P/W) Old P/W, A1A, New 6 character password; 123456
Change 6 digit Operator PIN Old PIN, A1P New 6 digit Operator PIN; 999999
Change device name Password, D1A, Device name; (max. 20 characters)
Change device number Password, D2A, Tel. number;
Change SMS recipient 1 (Alarm) Password, R1A, Tel. number; (or Password R1D to delete)
Change SMS recipient 2 (Alarm) Password, R2A, Tel. number; (or Password R2D to delete)
Change SMS recipient 3 (Alarm) Password, R3A, Tel. number; (or Password R3D to delete)
Change SMS recipient 4 (Alarm) Password, R4A, Tel. number; (or Password R4D to delete)
Add 1 to 8 gate access numbers Password, F2A, Tel. number; (Tel.no.1,Tel.no.2,..Tel.no.8;)
Add one temporary access number Oper. PIN, F2T, Tel. number,No. of access days from now;
(max. 99days )(See note 1 below)
Delete 1 to 8 gate access numbers Password, F2D, Tel. number; (Tel.no.1,Tel.no.2,..Tel.no.8;)
Enable security mode Password, F3E; Enabled
Disable security mode Password, F3D;
Enable daily SMS status report Password, F4E;
Disable daily SMS status report Password, F4D; Disabled
Daily SMS status report time Password, F4T, hh:mm; (24 hour format EG 13:00;) 12:00
Request status report Password, F4S;
Request Configuration report Password, F4C;
Enable power up report Password, F5E;
Disable power up report Password, F5D; Disabled
Power up report to recipient 1 Password, F5S; Enabled
Power up report to ALL recipients Password, F5A;
Gate open alarm time Password, F6T, Delay time in Sec; (max.9999sec.) (0=OFF) 240 sec.
Custom alarm message Password, F6M, Message; (max. 148 characters)
(Can be a relay command to another m2m)
Alarm on input +12V (ON) Password, F6H; ON
Alarm on input open (OFF) Password, F6L;
Relay contact impulse on missed call Password, F7P; Enabled
Relay contact ON/OFF & Pulse with
SMS Password, F7L; (To enable SMS control) Disabled
Updated system Date & Time Password, TIME; (Time automatically updated if using MTN)
Request remaining airtime report Password, AIRTIME;
Factory default & erase all numbers Password, DEFAULT; (Allow 1 minute for operation to complete)
Request over the air software update Password, SW UPDATE; APN name,user name,password,FTP IP (See note
ADDR,user name,password,file path, 4 below)
file name;
Operators Commands
Add one temporary access number Oper. PIN, TEMP, Tel. number,No. of access days from now;
(max. 99days )(See note 1 below)
Switch Relay ON Oper. PIN, RELAY ON;
Switch Relay OFF Oper. PIN, RELAY OFF;
Pulse relay ON/OFF Oper. PIN, PULSE; (Fixed 1 second on time)
Pulse relay ON/OFF Oper. PIN, Pulse, RELAY ON TIME IN SECONDS;
(Max. 99 seconds).

2
Notes
1) Operator commands can use the Admin or Operator PIN. The Operator PIN cannot be used for Configuration Commands.
2) The 6 character password is case sensitive. All other text is not case sensitive.
3) When the customised alarm message is a command to another Gcom500 – terminate the line with a comma and a
Semi-colon e.g. 123456,F6M,123456,PULSE,;
4) FTP site IP address is standard IPv4 format = xxx.xxx.xxx.xxx
All connection APN and FTP parameters will be case sensitive.
APN = Access Point Name.
FTP = File Transfer Protocol.

How to use the above parameter table.


Change Admin Password
Using an your cell phone, send an SMS message to the Gcom500 cell number with the following message.
Old Password,A1A,New 6 digit Password; (always finish your message with a semi-colon)
Eg: 123456,A1A,472567 or Abcd99;
Note- should you forget or have a problem with your Admin Password, please contact
DTS Security Products Head Office.

Notes:
1) Operator commands can use the Admin Pin or Operator Pin. The Operator Pin cannot be used for Configuration
Commands.
2) The 6 character Admin Password is case sensitive. All other text is not case sensitive.

Add/Change device name (The name that will appear on your status message)
Using your cell phone, send an SMS message to the Gcom500 cell number with the following message.
Password,D1A,Device name; (max. 20 characters)
Eg: 123456,D1A,Home Front Gate;

Add/Change device number (The Gcom500 telephone number)


As above but using telephone number (remember to use international format) instead of a name.
Eg: 123456,D2A, +27831231234;

Add/Change SMS recipients


The above procedure remains the same. You must just select the right P Code
(R1A, R2A, R3A or R4A) for the recipient number. (Recipients must be consecutive)

Add gate access numbers


You can add 1, 2, 3, up to 8 numbers with one SMS.
Eg: the message for 1 number.
123456,F2A, +27831231234;

The message for more than 1 number.


123456,F2A, +27831231234, +27831231235, +27831231236,up to 8 numbers;

Delete gate access numbers


Same as above but use correct P Code (F2D)
Note: All the other parameters are changed the same way as explained above using your PIN number followed by a comma followed by
the P Code followed by a comma followed by the Data were applicable, always finishing off the message with a semi-colon.

Wiring of the Gcom500 to a gate motor

3
Please note that if the Gcom500 is located or mounted in a metal housing, the existing antenna must be
removed and replaced with an external antenna with a SMA-RF connection.

Note: The Gate switch can also be an Alarm contact.

_________________________________________________________________________________

Gcom500 GSM Controller.


The Gcom500 is a universal single relay control unit designed for access control of automated gate systems or for general
“SMS” or “Missed Call” Control/Switching applications.
Features.
Stores up to 500 telephone numbers for access control.
Permanent or time limited user access. (ideal for Hotels and Guest houses)
Real time calendar clock.
Configuration parameters remotely set by SMS.
Supply voltage monitoring. (will SMS a warning message if low voltage)
Single monitored input for ON/OFF condition SMS alarming.
Programmable time delay for input monitoring.
Output relay operated from SMS commands or free missed calls.
User programmable alarm message. (message can be a SMS command to another Gcom500)
Status and remaining airtime reporting.
Compatible with all local GSM networks.
Very low power consumption. (less than 20mA in standby)
Operates from 12VDC power supply. (battery backup recommended)
Low voltage output relay rated at 1Amp.
IP50 housing.
ICASA approved.

Typical Application.
Access control system.
Industrial or domestic alarm control and monitoring.
Electric fence control and monitoring.
Refrigeration monitoring.
Remote pump control / water level monitoring.

____________________________________________________________________________________________________________

Manufacturers warranty.
 All goods manufactured by DTS Security Products carry a 24 month factory warranty from date of
invoice.
 All goods are warranted to be free from faulty components and manufacture.
 Faulty goods will be repaired or replaced at the sole discretion of DTS Security Products, free of charge.
 This warranty is subject to the goods being returned to the premises of DTS Security Products.
 This warranty excludes lightning damage, insect damage and damage caused
by faulty installation.
 In the event of the goods being supplied by dealer, merchant, agent or duly appointed installer of DTS
Security Products, the claim must be directed to
that supplier.
 The carriage of goods is for the customer’s account.
 This warranty is only valid if the correct installation and application of goods,

as laid out in the applicable documentation accompanying said goods, is


adhered to.
 All warranty claims must be accompanied by the original invoice.
 The liability of DTS Security Products and / or their distributors is limited as herein set out DTS Security
Products and / or their distributors will not be
liable for consequential or incident damages howsoever arising.

You might also like