WL-N/WLM-N: Select The Best Two-Circuit Switch For The Operating Environment and Application From A Wide Range of Models

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

WL-N/WLM-N
Select the Best Two-circuit Switch for the
Operating Environment and Application
from a Wide Range of Models
• A wide selection of models is available, including
General-purpose, Environment-resistant, and Spatter-
prevention Switches.
• Standard-feature gold-clad crossbar contacts provide
high reliability.
Appllicable to either standard loads or microloads.
• Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
• Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on
approved models.
Be sure to read Safety Precautions on page 44 to 48 and
Safety Precautions for All Limit Switches.

Features
Standard Switches Features Common to All Switches
Many Variations in Standard Limit Switches DPDB Operation
A Wide Range of Models The double-pole, double-break structure ensures circuit braking.
The series includes includes many different actuators that you select
11 13
to match the workpiece shape and motion, and a wide range of Switch
variations, such as models with operation indicators for easier Za 12 14
(NO)14 13(NO)
working and maintenance and models with different types of
connectors.
(NC)12 11(NC) Load Load

Environment-resistant Switches
Select from Six Types of Environment Resistance Degree of Protection; IP67
The series includes Airtight Switches, Hermetic Switches, Heat-
resistant Switches, Low-temperature Switches, Corrosion-proof Approved Standards to Aid Export Machines
switches, and Weather-proof Switches. You can select the model The Switches are certified for EN/IEC, UL, cUL, and CCC making
based on the onsite environment. them ideal for export machines.

Applicable to Either Standard Loads or Microloads


Spatter-prevention Switches
Standard-feature gold-clad contacts provide high reliability.
Excellent Performance on Arc Welding Lines or Sites with The use of a high-contact-pressure crossbar structure also increases
Spattering Cutting Powder reliability.
Ideal for Welding Sites
Easy to Work With
These Switches use stainless steel or resin to prevent the adhesion
of spatter. Downsizing of the built-in switch has increased the space to house the
They can be used to reduce problems caused by zinc power wiring.
generated during welding. The insulating paper that was often in the way when wiring has been
eliminated.
Nickle-plated steel screws are used for the terminal screws.
Long-life Switches The screws adhere to magnetized screwdrivers to prevent dropping and
Mechanical Endurance of 30 Million Operations loosing them.
Long-life Models for High-frequency Applications
Models with Connectors to Reduce Wiring
A mechanical durability of 30 million operations minimum is provided.
The head features a double-seal structure with a head cap and oil A neon lamp or LED indicates the operating status.
seal. The 3D structure of the lamp cover disperses light so you can check
the operating status from the side.

1
WL-N/WLM-N
Product Configuration

• Basic Switches WLC@-N

• High-sensitivity Switches WLG@-N


Standard
• High-precision Switches WLGCA2-N

• Protective Switches WLCA32-@-N

General-purpose • Indicator-equipped Switches:


Operation indicators Neon lamps WL@-LE-N

• Indicator-equipped Switches:
Light emitting diodes (LED) WL@-LD-N

• Direct-wired Switches WL-@LDK@-N


Sensor I/O connectors
• Pre-wired Switches WL@-@LD-M1@-N
WL@-@LD-AGJ-N
WL@-@LD-DGJ-N
WL@-@LD-DK1EJ-N

• Airtight Switches WL@-55-N

• Hermetic Switches WL@-139-N


WL@-140-N
WL@-141-N
WL@-145-N
WL@-RP40-N
WL@-RP60-N
Environment-resistant
• Heat-resistant Switches WL@-TH-N

• Low-temperature Switches WL@-TC-N

• Corrosion-proof Switches WL@-RP-N

• Weather-proof Switches WL@-P1-N

• Basic Switches WLC@-@S-N

Spatter-prevention • High-sensitivity Switches WLG@-@S-N

• High-precision Switches WLGCA2-@S-N

• Basic Switches WLMCA2-@-N

Long-life • High-sensitivity Switches WLMG2-@-N

• High-precision Switches WLMGCA2-@-N

2
WL-N/WLM-N

Environment-resistant Switches

Item Environment-resistant
Type Model Application Environment-resistant construction Applicable models
All models except the low-
temperature and heat-re-
Airtight seal WL@-55-N Uses an airtight built-in switch. sistant models
Note: Use the SC Connector for the conduit opening. Note: Models can be produced
using standard
actuators.
WL@-139-N All models except the low-
For uses in locations sub- temperature and heat-re-
WL@-140-N ject to cutting oil or water
sistant models
Hermetic seal WL@-141-N Refer to page 29 for information on the environ- Note: Models can be produced
(Molded terminals/ WL@-145-N ment-resistant construction of Switches with Her- using standard
Anti-coolant) actuators. Only the
WL@-RP40-N metic Seals.
WLCA2-N, WLGCA2-N,
or WLG2-N can be
WL@-RP60-N produced for the WL@-
141-N and WL@-145-N.
Can be used at a tempera- All models except airtight
ture of –40°C (operating • Uses a general-purpose built-in switch. seal, hermetic seal, heat-
Low-temperature WL@-TC-N temperature range: –40 to • Epichlorhydrin rubber is used for rubber parts resistant, corrosion-proof,
40°C), but cannot with- such as the O-ring, gasket, etc. and indicator-equipped
stand icing. models
All models except airtight
seal, hermetic seal, heat-
Can be used in tempera-
resistant, corrosion-proof,
tures of 120°C (operating • Fluorine rubber is used for rubber parts such as
Heat-resistant WL@-TH-N and indicator-equipped, ny-
temperature range: 5 to the O-ring, gasket, etc.
lon roller (WLCA2-26N-N),
120°C).
seal roller models, and res-
in rod (WLNJ-2-N) models
• Diecast parts, such as the switch box, are made
of corrosion-proof aluminum.
• Rubber sealing parts are made of fluorine
rubber, which aids in resisting oils and All models except fork lever
For use in locations sub- chemicals. lock (WLCA32-41 to -44-
Corrosion-proof WL@-RP-N ject to corrosive gases and • Exposed nuts and screws (except the actuator N), low-temperature, heat-
chemicals. section) are made of stainless steel. resistant, and indicator-
• Moving and rotary parts such as rollers are equipped models
made of sintered stainless steel or stainless
steel.
• The Head, box, and cover are yellow.
Only basic (WLCA2-N/
CA12-N/CL-N), and high-
• Rubber parts are made from epichlorhydrin
sensitivity overtravel
rubber, which has a high-tolerance to changes in
(WLG2-N/G12-N/GL-N)
temperature.
For use in parking lots and models (excluding heat-re-
Weather-proof WL@-P1-N • Rollers are made of stainless steel to improve
other outdoor locations. sistant models).
corrosion resistance.
This does not apply to Low-
• Exposed nuts and screws are made of stainless
temperature or Heat-resis-
steel.
tance, or Indicator-
equipped Switches.

3
WL-N/WLM-N

Selection Guide
With the WL-N Series, OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for
your application.

The WL-N Series consists of four basic types: General-purpose, Environment-resistant, Spatter-protec-
tion, and Long-life Switches. WLCA2-N Switches can be used for the most common applications.

According to Operating Environment


Environment Key specifications Models

−10°C +80°C WL@-N General-purpose


Ambient operating temperature

Normal Switches
Water-resistant to IP67. WLM@-N Long-life Switches

+5°C +120°C
WL@-TH-N Heat-resistant
High-temperature Switches *1
To increase heat resistance, the rubber material (fluorine rubber)
and the plunger material (PEEK) have been changed.
−40°C +40°C
WL@-TC-N Low-temperature
Low-temperature
To increase resistance to cold, epichlorhydrin rubber and other Switches *1
measures are used.

Rubber parts are made from epichlorhydrin rubber, which has a


high-tolerance to changes in temperature. WL@-P1-N Weather-proof
Outdoors Stainless steel is used for the screws. Switches *1
Rollers are made of stainless steel to provide superior corrosion
resistance.
Corrosion-proof specifications have been used for the housing,
fluorine rubber has been used for rubber parts, and stainless WL@-RP-N Corrosion-proof
Chemicals and oil
steel has been used for screws and nuts (except for the actuator) Switches *1
to increase resistance to oils, chemicals, and weather.
Water drops and mist Uses an airtight built-in switch. WL@-55-N Airtight Switches *1
Cables are attached. Uses a general-purpose built-in switch.
WL@-139-N
The cover screws, case cover, and conduit opening are molded
Hermetic, Molded-terminal
from epoxy resin to increase the seal.
Switches *1, *2
(The cover cannot be removed.)
Cables are attached. Uses an airtight built-in switch.
The case cover and conduit opening are molded from epoxy WL@-RP40-N
Constant water resin to increase the seal. (The cover cannot be removed.) Hermetic, Molded-terminal
Operating environment

drops and mist The SC connector can be removed, so it is possible to use Switches *1, *2
flexible conduit for the cable.
Cables are attached. Uses an airtight built-in switch.
WL@-140-N
The cover screws, case cover, and conduit opening are molded
Hermetic, Molded-terminal
from epoxy resin to increase the seal.
Switches *1, *2
(The cover cannot be removed.)
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are molded
from epoxy resin to increase the seal. WL@-141-N, -145-N
(The cover cannot be removed.) Hermetic, Molded-terminal
Constant water Double seal against oil including head cap countermeasure for
drops or splattering Switches *1, *2
cutting chips and an oil seal. (Only the WLCA2-N, WLG2-N, and
cutting powder -141: The Head section is molded from epoxy resin; WLGCA2-N, can be produced.)
Head direction cannot be changed.
-145: The Head section is molded from epoxy resin;
Head can be in any of 4 directions.
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, conduit opening, and head screws
WL@-RP60-N
are molded from epoxy resin to increase the seal.
Coolant Hermetic, Molded-terminal
(The cover and head cannot be removed.)
Switches *1, *2
Rubber parts are made from fluorine rubber to increase
resistance to coolant.

Spattering from To prevent spatter during welding, a heat-resistant resin is used


WL@-S-N Spatter-prevention
welding for the indicator cover and screws and rollers are all made from
Switches
stainless steel.

*1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page.
*2. Refer to page 29 for information on the construction of Hermetic Switches.

4
WL-N/WLM-N

According to Application Conditions


Conditions Key specifications Models

10 A at 125,250, or 500 VAC


Switching standard
0.8 A at 125 VDC
loads
0.4 A at 250 VDC
Entire WL@-@-N Series
Load

Applicable to either standard loads or microloads.


Switching 0.1 A at 125 VAC, resistive load
microloads 0.1 A at 30 VDC, resistive load

Mechanical: 15 million operation min.


Normal durability WL@-N General-purpose Switches
(10 million operation min. for high-sensitivity
WL@-S-N Spatter-prevention Switches
Durability

models or flexible rod models)

Long-life Mechanical: 30 million operation min. WLM@-N Long-life Switches

According to Ease of Installation and Maintenance


Conditions Key specifications Models
Neon lamp
WL@-LE-N
125 to 250 VAC
General-purpose, Indicator-equipped (Neon Lamp) Switches
Operation indicator

Switching light-ON between operating/not


WL@-LES-N
operating. (Switching is not possible for
Daily inspections Spatter-prevention, Indicator-equipped (Neon Lamp) Switches
Switches with Molded Terminals.)
and maintenance
checks LED
WL@-LD-N
10 to 115 VAC/DC
General-purpose, Indicator-equipped (LED) Switches
Switching light-ON between operating/not
WL@-LDS-N
operating. (Switching not possible for models
Spatter-prevention, Indicator-equipped (LED) Switches
with molded terminals.)

Screw terminals. No ground terminal. WL@-N General-purpose Switches


Screw tightening Conduit size: G1/2 WLM@-N Long-life Switches
and installation Screw terminals. Ground terminal.
Conduit size: 4 sizes WL@-N General-purpose Switches

WL@-@LDK13@-N
Direct-wired connector, 2-conductor. General-purpose, Direct-wired Connector Switches
Greatly reduces wiring work. WLM@-LDK13@-N
One-touch Long-life, Direct-wired Connector Switches
connector
Wiring specification

attachment WL@-@LDK43@-N
Direct-wired connector, 4-conductor. General-purpose, Direct-wired Connector Switches
Greatly reduces wiring work. WLM@-LDK43@-N
Long-life, Direct-wired Connector Switches

WL@-@LD-M1@J-N
Pre-wired connector, 2-conductor. General-purpose, Pre-wired Connector Switches
Greatly reduces wiring work. WL@-@S-M1@J-1-N
Smartclick connectors for even easier Spatter-prevention, Pre-wired Connector Switches
maintenance. WLM@-LD-M1@J-N
Connector
Long-life, Pre-wired Connector Switches
attachment in
control and relay
WL@-@LD-@GJ-N
boxes
Pre-wired connector, 4-conductor. General-purpose, Pre-wired Connector Switches
Greatly reduces wiring work. WL@-@S-@GJS-N
Smartclick connectors for even easier Spatter-prevention, Pre-wired Connector Switches
maintenance. WLM@-LD-@GJ-N
Long-life, Pre-wired Connector Switches

5
WL-N/WLM-N

According to Form of Operation


Detection object Key specifications Models

General TT (total travel) PT (pretravel) WLCA2-N General-purpose Switches


15° 25° 20° WLCA2-2-N General-purpose Switches
90° 90°
WLCA2-2N-N General-purpose Switches
WLCA2-@S-N Spatter-prevention Switches
Operation angles

Passing dogs WLCA2-N WLCA2-2-N WLCA2-2N-N WLMCA2-N Long-life Switches

10°
90° 90° WLG2-N General-purpose Switches
Passing dogs,
WLG2-@S-N Spatter-prevention Switches
high sensitivity
WLMG2-N Long-life Switches


90° 90° WLGCA2-N General-purpose Switches
High precision WLGCA2-@S-N Spatter-prevention Switches
WLMGCA2-N Long-life Switches

R38 ● Short lever WL@2-N Roller Lever Actuators


● One-Horizontal operation possible. WL@2-@S-N Roller Lever Actuators
● Head mounts in any of 4 directions. WLM@2-N Roller Lever Actuators
Dogs and R50 ● Medium lever
workpieces ● One-side operation possible. WL@2-7-N Roller Lever Actuators
(Mounts in any of ● Head mounts in any of 4 directions.
4 directions)
R63
● Long lever
● One-side operation possible. WL@2-8-N Roller Lever Actuators
● Head mounts in any of 4 directions.

R25 to 89
Adjustable between ● One-Horizontal operation possible.
WL@12-N Adjustable Roller Lever Actuators
dog and lever ● Head mounts in any of 4 directions.

25 to 140 ● One-Horizontal operation possible.


WLCL-N Adjustable Rod Lever Actuators
● Head mounts in any of 4 directions.

Dogs or workpieces
with large
350 to 380 ● One-side operation possible.
WLCAL4-N Adjustable Rod Lever Actuator
deflection ● Head mounts in any of 4 directions.

427.5
● One-side operation possible.
WLCAL5-N Rod Spring Lever Actuator
Actuators

● Head mounts in any of 4 directions.

● Head mounts in any of 4 directions. WLCA32-41-N Fork Lever Lock Actuator

● Head mounts in any of 4 directions. WLCA32-42-N Fork Lever Lock Actuator


Round-trip
operation of
passing dogs
● Head mounts in any of 4 directions. WLCA32-43-N Fork Lever Lock Actuator

● Head mounts in any of 4 directions. WLCA32-44-N Fork Lever Lock Actuator

● Equipped with sealing boot. WLD18-N Sealed Top Plunger Actuator

● Head mounts in any of 4 directions. WLSD-N Horizontal Plunger Actuator

Cams or ● Equipped with sealing boot. WLD38-N Sealed Top-ball Plunger Actuator
workpieces with
vertical movement ● Head mounts in any of 4 directions. WLSD3-N Horizontal-ball Plunger Actuator

● Equipped with sealing boot. WLD28-N Sealed Top-roller Plunger Actuator

● Head mounts in any of 4 directions. WLSD2-N Horizontal-roller Plunger Actuator

6
WL-N/WLM-N
Application Examples

Detection of Passing Pallets on Production Detection of Work Table Origins (X, Y, and Z)
Lines on Machine Tools

Detection of Forward and Reverse Movement Detection of Arm Movement on Welding


of Hydraulic Cylinders on Molding Machines Robots

Detection of Car Pallet Positions in Parking Detection of Vertical Limits on Conveyor


Towers Systems

7
WL-N/WLM-N
Model Number Structure
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
General-purpose Switches

WL@ - @ @ @ @ -N
(1) (2) (3) (4) (5)

(1) Actuator and Property Specifications (2) Built-in Switch Type


Code Lever Pretravel (PT) Code Specification
CA2 Roller lever: R38 mm Blank Standard built-in switch
CA2-7 Roller lever: R50 mm 55 Airtight built-in switch
CA2-8 Roller lever: R63 mm
CA12 Adjustable roller lever: R25 to 89 mm 15±5° (3) Conduit Size, Ground Terminal Specifications
CL Adjustable rod lever: 25 to 140 mm Specifications
Code
CAL4 Adjustable rod lever: 350 to 380 mm Conduit Size Ground terminal
CAL5 Rod spring lever Blank G1/2 None
CA2-2 Roller lever: R38 mm G1 G1/2
CA12-2 Adjustable roller lever: R25 to 89 mm 25±5° G Pg13.5
Provided *
CL-2 Adjustable rod lever: 25 to 140 mm Y M20
CA2-2N Roller lever: R38 mm TS 1/2-14NPT
CA12-2N Adjustable roller lever: R25 to 89 mm MAX 20° * Models with ground terminals are certified for EN/IEC (CE Marking).
CL-2N Adjustable rod lever: 25 to 140 mm
G2 Roller lever, high sensitivity: R38 mm (4) Indicator Type
Adjustable roller lever, high sensitivity: Code Specifications
G12
R25 to 89 mm 10° +2°
−1°
Blank No indicator
Adjustable rod lever, high sensitivity:
GL LE Neon lamp: 125 to 250 VAC
25 to 140 mm
GCA2 Roller lever, high precision: R38 mm 5° +2°0° LD LED (10 to 115 VAC/DC)

CA32-41 Fork lever lock


(5) Lever Type
CA32-42 Fork lever lock 50±5°
CA32-43 Fork lever lock Code Specifications
D18 Sealed top plunger Blank Standard lever (Allen-head bolt)
D28 Sealed top-roller plunger 1.7 mm A Double nut lever
D38 Sealed top-ball plunger
SD Horizontal plunger
SD2 Horizontal-roller plunger 2.8 mm
SD3 Horizontal-ball plunger
NJ Flexible rod: Coil spring
20±10 mm
NJ-30 Flexible rod: Coil spring, multi-wire
NJ-2 Flexible rod: Resin rod
40±20 mm
NJ-S2 Flexible rod: Steel wire

8
WL-N/WLM-N

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
General-purpose Switches

Sensor I/O Connector Switches

WL@ - @ L D @ -N
(1) (2) (3) (4)

(1) Actuator and Property Specifications (2) Built-in Switch Type


Code Lever Pretravel (PT) Code Specification
CA2 Roller lever: R38 mm 15±5° Blank Standard built-in switch
G2 Roller lever, high sensitivity: R38 mm 10° +2°
−1° 55 Airtight built-in switch
GCA2 Roller lever, high precision: R38 mm 5° +2°0°
D28 Sealed top-roller plunger 1.7 mm (3) Indicator Type
Code Specifications
LD LED (10 to 115 VAC/DC)

(4) Connector Type


Specification
Code
Shape Voltage used *1 Wiring locations Connector pin No. *2
K13A AC NO only NO: 3 4
K13 DC NO only NO: 3 4
Direct-wired connector Threaded (M12)
K43A AC NC+NO NC: 1 2 , NO: 3 4
K43 DC NC+NO NC: 1 2 , NO: 3 4
-M1J DC NO only NO: 3 4
-M1GJ DC NO only NO: 1 4
-M1JB DC NC only NC: 2 3
Threaded (M12)
-AGJ AC NC+NO NC: 1 2 , NO: 3 4
-DGJ DC NC+NO NC: 1 2 , NO: 3 4
-DK1EJ Pre-wired connector *3 DC NO only NC: 2 , NO: 3 4
-M1TJ DC NO only NO: 3 4
-M1TGJ DC NO only NO: 1 4
-M1TJB Smartclick DC NC only NC: 2 3
-DTGJ DC NC+NO NC: 1 2 , NO: 3 4
-DTK1EJ DC NO only NC: 2 , NO: 3 4

*1. DC models are certified for EN/IEC (CE Marking).


*2. Refer to Contact Forms on page 16 for details on connector pin numbers.
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.

9
WL-N/WLM-N

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
Environment-resistant Switches

WL@ - @ @ @ @ @ @ @ @ -N
(1) (2) (3) (4) (5) (6) (7) (8) (9)

(1) Actuator and Property Specifications (5) Hermetic Specification


Code Lever Pretravel (PT) Code Specifications
CA2 Roller lever: R38 mm Blank No cable molding.
CA2-7 Roller lever: R50 mm Standard built-in switch. Cable is attached.
139 Molded conduit opening and cover. (The cover cannot be re-
CA2-8 Roller lever: R63 mm
moved.)
CA12 Adjustable roller lever: R25 to 89 mm 15±5°
Airtight built-in switch. Cable is attached.
CL Adjustable rod lever: 25 to 140 mm 140 Molded conduit opening, cover, and cover screws. (The cover
CAL4 Adjustable rod lever: 350 to 380 mm cannot be removed.)

CAL5 Rod spring lever Airtight built-in switch. Cable is attached.


Molded conduit opening, cover, head, cover screws, and head
CA2-2 Roller lever: R38 mm screws. (The cover cannot be removed and the head direction
141
CA12-2 Adjustable roller lever: R25 to 89 mm 25±5° cannot be changed.)
Double seal against oil including head cap countermeasure for
CL-2 Adjustable rod lever: 25 to 140 mm cutting chips and an oil seal.
CA2-2N Roller lever: R38 mm Airtight built-in switch. Cable is attached.
CA12-2N Adjustable roller lever: R25 to 89 mm MAX 20° Molded conduit opening, cover, and cover screws. (The cover
cannot be removed. The head can be mounted in any of 4 di-
CL-2N Adjustable rod lever: 25 to 140 mm 145
rections.)
G2 Roller lever, high sensitivity: R38 mm Double seal against oil including head cap countermeasure for
Adjustable roller lever, high sensitivity: R25 cutting chips and an oil seal.
G12
to 89 mm 10° +2°
−1° Airtight built-in switch. Cable is attached.
Adjustable rod lever, high sensitivity: 25 to Molded conduit opening and cover. (The cover cannot be re-
GL RP40 moved.)
140 mm
+2°
SC Connector can be removed, so it is possible to use flexible
GCA2 Roller lever, high precision: R38 mm 5° 0° conduits for the cable.
CA32-41 Fork lever lock Airtight built-in switch. Cables are attached.
CA32-42 Fork lever lock 55° Molded conduit opening, cover, cover screws, and head
RP60 screws. (The cover cannot be removed and the head direction
CA32-43 Fork lever lock cannot be changed.)
D18 Sealed top plunger Fluorine rubber is used for all rubber parts.
D28 Sealed top-roller plunger 1.7 mm
D38 Sealed top-ball plunger (6) Conduit Size, Ground Terminal Specifications
SD Horizontal plunger Specifications
Code
SD2 Horizontal-roller plunger 2.8 mm Conduit Size Ground terminal
SD3 Horizontal-ball plunger Blank G1/2 None
NJ Flexible rod: Coil spring G1 G1/2
20±10 mm
NJ-30 Flexible rod: Coil spring, multi-wire G Pg13.5
Provided *2
NJ-2 Flexible rod: Resin rod Y M20
40±20 mm
NJ-S2 Flexible rod: Steel wire TS 1/2-14NPT
*2. Models with ground terminals are certified for EN/IEC (CE
(2) Environment-resistant Model Specifications Marking).
Code Specifications (7) Indicator Type
Blank Standard
Code Specifications
RP Corrosion-proof
Blank No indicator
P1 Weather-proof
LE Neon lamp: 125 to 250 VAC
(3) Built-in Switch Type LD LED (10 to 115 VAC/DC)
*3. Cannot be combined with Corrosion-proof (RP), Weather-proof
Code Specifications (P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
Blank Standard built-in switch
55 Airtight built-in switch (8) Indicator Wiring Specification
Code Specifications
(4) Temperature Specifications
2 NC connection: Light-ON when operating
Code Specifications 3 NO connection: Light-ON when not operating
Blank Standard: −10°C to +80°C *4. Always include the indicator wiring specification if you specify a
TH Heat-resistant: +5°C to +120°C *1 (5) hermetic structure and an (7) indicator.
TC Low-temperature: −40°C to +40°C *1
*1. Cannot be combined with Corrosion-proof (RP) or Weather-proof (9) Lever Type
(P1) Switches. Code Specifications
Blank Standard lever (Allen-head bolt)
A Double nut lever

10
WL-N/WLM-N

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
Spatter-prevention Switches

WL@ - @ @ S@ -N
(1) (2) (3) (4)

(1) Actuator and Property Specifications


Code Lever Pretravel (PT)
CA2 Roller lever: R38 mm 15±5°
G2 Roller lever, high sensitivity: R38 mm 10° +2°
−1°

GCA2 Roller lever, high precision: R38 mm 5° +2°0°


D28 Sealed top-roller plunger 1.7 mm

(2) Built-in Switch Type


Code Specifications
Blank Standard built-in switch
55 Airtight built-in switch

(3) Indicator Type


Code Specifications
LE Neon lamp: 125 to 250 VAC *1
LD LED (10 to 115 VAC/DC)
*1. Cannot be combined with a Switch with a Connector.

(4) Connector Type


Specifications
Code
Shape Voltage *2 Wiring locations Connector pin No. *3
Blank No connector ---- ---- ---- ----
-M1J-1 DC NO only NO: 3 4
-M1GJ-1 Threaded (M12) DC NO only NO: 1 4
Pre-wired Connector *4
-DGJS DC NC+NO NC: 1 2 , NO: 3 4
-DTGJS Smartclick DC NC+NO NC: 1 2 , NO: 3 4
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 16 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.

11
WL-N/WLM-N

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
Long-life Switches

WLM@ - LD @ -N
(1) (2) (3)

(1) Actuator and Property Specifications


Code Lever Pretravel (PT)
CA2 Roller lever: R38 mm 15±5°
G2 Roller lever, high sensitivity: R38 mm 10° +2°
−1°

GCA2 Roller lever, high precision: R38 mm 5° +2°0°

(2) Indicator Type


Code Specifications
LD LED (10 to 115 VAC/DC)

(3) Connector Type


Specifications
Code
Shape Voltage Wiring locations Connector pin No.
Blank Screw terminals: G1/2 conduit ---- ---- ---- ----
K13A AC NO only NO: 3 4
K13 DC NO only NO: 3 4
Direct-wired connector Threaded (M12)
K43A AC NC+NO NC: 1 2 , NO: 3 4
K43 DC NC+NO NC: 1 2 , NO: 3 4
-M1J DC NO only NO: 3 4
-AGJ Threaded (M12) AC NC+NO NC: 1 2 , NO: 3 4
-DGJ DC NC+NO NC: 1 2 , NO: 3 4
Pre-wired connector *1
-M1TJ DC NO only NO: 3 4
-ATGJ Smartclick AC NC+NO NC: 1 2 , NO: 3 4
-DTGJ DC NC+NO NC: 1 2 , NO: 3 4
*1. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.

12
WL-N/WLM-N
Ordering Information
General-purpose Switches

Standard Switches
Switches with Lever Actuators
Actuator
Roller lever R38 Roller lever: R50 Roller lever: R63

Item Pretravel (PT) Model Model Model


15±5° WLCA2-N WLCA2-7-N WLCA2-8-N
Basic 25±5° WLCA2-2-N ----- -----
MAX20° WLCA2-2N-N ----- -----
High-sensitivity 10° +2°
-1° WLG2-N ----- -----
High-precision 5° +2°0° WLGCA2-N ----- -----

Actuator
Adjustable rod lever: Adjustable rod lever:
Adjustable roller lever Rod spring lever
25 to 140mm 350 to 380mm

Item Pretravel (PT) Model Model Model Model


15±5° WLCA12-N WLCL-N WLCAL4-N WLCAL5-N
Basic 25±5° WLCA12-2-N WLCL-2-N ----- -----
MAX20° WLCA12-2N-N WLCL-2N-N ----- -----
High-sensitivity 10° +2°
-1° WLG12-N WLGL-N ----- -----

Actuator
Fork lever lock Fork lever lock Fork lever lock Fork lever lock

Movement until
Item Model Model Model Model
the lever reverses
Protective 50±5° WLCA32-41-N WLCA32-42-N WLCA32-43-N WLCA32-44-N

Switches with Plunger Actuators


Actuator
Sealed top-roller Sealed top-ball
Sealed top plunger
plunger plunger

Item Pretravel (PT) Model Model Model


Basic 1.7 mm WLD18-N WLD28-N WLD38-N

Actuator
Horizontal-roller Horizontal-ball
Horizontal plunger
plunger plunger

Item Pretravel (PT) Model Model Model


Basic 2.8 mm WLSD-N WLSD2-N WLSD3-N

Switches with Flexible Rod Actuators


Actuator
Coil spring Coil spring
(spring diameter: 6.5) (spring diameter: 4.8)

Item Pretravel (PT) Model Model


Basic 20±10 mm WLNJ-N WLNJ-30-N

Actuator
Resin rod Steel wire
(rod diameter: 8) (wire diameter: 1)

Item Pretravel (PT) Model Model


Basic 40±20 mm WLNJ-2-N WLNJ-S2-N

13
WL-N/WLM-N

General-purpose Switches

Operation Indicator Switches


Switches with Lever Actuators
Actuator
Roller lever: R38 Roller lever: R50 Roller lever: R63

Indicator Item Pretravel (PT) Model Model Model


15±5° WLCA2-LE-N WLCA2-7LE-N WLCA2-8LE-N
Basic 25±5° WLCA2-2LE-N ----- -----
Neon lamp MAX20° WLCA2-2NLE-N ----- -----
High-sensitivity 10° +2°
-1° WLG2-LE-N ----- -----
High-precision 5° +2°0° WLGCA2-LE-N ----- -----
15±5° WLCA2-LD-N WLCA2-7LD-N WLCA2-8LD-N
Basic 25±5° WLCA2-2LD-N ----- -----
LED MAX20° WLCA2-2NLD-N ----- -----
High-sensitivity 10° +2°
-1° WLG2-LD-N ----- -----
High-precision 5° +2°0° WLGCA2-LD-N ----- -----

Actuator
Adjustable rod lever: Adjustable rod lever:
Adjustable roller lever: Rod spring lever
25 to 140mm 350 to 380mm

Indicator Item Pretravel (PT) Model Model Model Model


15±5° WLCA12-LE-N WLCL-LE-N WLCAL4-LE-N WLCAL5-LE-N
Basic 25±5° WLCA12-2LE-N WLCL-2LE-N ----- -----
Neon lamp
MAX20° WLCA12-2NLE-N WLCL-2NLE-N ----- -----
High-sensitivity 10° +2°
-1° WLG12-LE-N WLGL-LE-N ----- -----
15±5° WLCA12-LD-N WLCL-LD-N WLCAL4-LD-N WLCAL5-LD-N
Basic 25±5° WLCA12-2LD-N WLCL-2LD-N ----- -----
LED
MAX20° WLCA12-2NLD-N WLCL-2NLD-N ----- -----
High-sensitivity 10° +2°
-1° WLG12-LD-N WLGL-LD-N ----- -----

Actuator
Fork lever lock Fork lever lock Fork lever lock

Movement until
Indicator Item Model Model Model
the lever reverses
Neon lamp Basic 50±5° WLCA32-41LE-N WLCA32-42LE-N WLCA32-43LE-N
LED Basic 50±5° WLCA32-41LD-N ----- WLCA32-43LD-N

Switches with Plunger Actuators


Actuator
Sealed top-roller Sealed top-ball
Sealed top plunger
plunger plunger

Indicator Item Pretravel (PT) Model Model Model


Neon lamp Basic 1.7 mm WLD18-LE-N WLD28-LE-N WLD38-LE-N
LED Basic 1.7 mm WLD18-LD-N WLD28-LD-N WLD38-LD-N

Actuator
Horizontal-roller Horizontal-ball
Horizontal plunger
plunger plunger

Indicator Item Pretravel (PT) Model Model Model


Neon lamp Basic 2.8 mm WLSD-LE-N WLSD2-LE-N WLSD3-LE-N
LED Basic 2.8 mm WLSD-LD-N WLSD2-LD-N WLSD3-LD-N

Switches with Flexible Rod Actuators


Actuator
Coil spring Coil spring
(spring diameter: 6.5) (spring diameter: 4.8)

Indicator Item Pretravel (PT) Model Model


Neon lamp Basic 20±10 mm WLNJ-LE-N WLNJ-30LE-N
LED Basic 20±10 mm WLNJ-LD-N WLNJ-30LD-N

Actuator
Resin rod Steel wire
(rod diameter: 8) (wire diameter: 1)

Indicator Item Pretravel (PT) Model Model


Neon lamp Basic 40±20 mm WLNJ-2LE-N WLNJ-S2LE-N
LED Basic 40±20 mm WLNJ-2LD-N WLNJ-S2LD-N

14
WL-N/WLM-N

General-purpose Switches

Sensor I/O Connector Switches


Switches with Direct-wired Connectors
Actuator
Roller lever: R38

Item Basic High-sensitivity High-precision


Wiring Connector
Connector shape Built-in switch type Voltage Model Model Model
locations pin No.
NO only NO 3 4 WLCA2-LDK13A-N ----- -----
AC NC 1 2
NC + NO WLCA2-LDK43A-N ----- -----
NO 3 4
General-purpose
NO only NO 3 4 WLCA2-LDK13-N WLG2-LDK13-N WLGCA2-LDK13-N
Threaded (M12) DC NC 1 2
NC + NO WLCA2-LDK43-N WLG2-LDK43-N WLGCA2-LDK43-N
NO 3 4
NO only NO 3 4 WLCA2-55LDK13-N WLG2-55LDK13-N WLGCA2-55LDK13-N
Airtight AC NC 1 2
NC + NO WLCA2-55LDK43-N WLG2-55LDK43-N WLGCA2-55LDK43-N
NO 3 4

Switches with Pre-wired Connectors


Actuator
Roller lever R38

Item Basic High-sensitivity High-precision


Wiring Connector
Connector shape Built-in switch type Voltage Model Model Model
locations pin No.
NO 3 4 WLCA2-LD-M1J-N WLG2-LD-M1J-N WLGCA2-LD-M1J-N
NO only
NO 1 4 WLCA2-LD-M1GJ-N WLG2-LD-M1GJ-N WLGCA2-LD-M1GJ-N
NC only NC 2 3 WLCA2-LD-M1JB-N WLG2-LD-M1JB-N -----
General-purpose
NC 1 2
NC + NO WLCA2-LD-DGJ-N WLG2-LD-DGJ-N WLGCA2-LD-DGJ-N
NO 3 4
NO 4 3
NO only WLCA2-LD-DK1EJ-N WLG2-LD-DK1EJ-N -----
NC 2
Threaded (M12)
NO 3 4 WLCA2-55LD-M1J-N ----- WLGCA2-55LD-M1J-N
DC NO only
NO 1 4 WLCA2-55LD-M1GJ-N WLG2-55LD-M1GJ-N WLGCA2-55LD-M1GJ-N
NC only NC 2 3 WLCA2-55LD-M1JB-N WLG2-55LD-M1JB-N WLGCA2-55LD-M1JB-N
Airtight
NC 1 2
NC + NO WLCA2-55LD-DGJ-N WLG2-55LD-DGJ-N WLGCA2-55LD-DGJ-N
NO 3 4
NO 4 3
NO only WLCA2-55LD-DK1EJ-N WLG2-55LD-DK1EJ-N -----
NC 2
NO only NO 3 4 ----- WLG2-LD-M1TJ-N -----
Smartclick General-purpose
NO only NC 2 3 ----- WLG2-LD-M1TJB-N -----
Note: The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.

15
WL-N/WLM-N

Contact Forms
Screw Terminal Switches Screw Terminal Switches
Indicator-equipped (Light-ON when Not Operating) Switches *1
Za
14 (NO) 13 (NO) Internal
circuits
Za
12 (NC) 11 (NC) 14 (NO) 13 (NO)

12 (NC) 11 (NC)

Direct-wired Connectors/Pre-wired Connectors


Indicator-equipped (Light-ON when Not Operating) Switches *1

AC Internal DC Internal
circuits circuits
Za Za

NO NC NC NO NO NC NC NO
WL@-@K13A-N 4 3 WL@-@K13-N
WL@-@-M1J-N 4 3
WL@-@K43A-N
4 1 2 3 WL@-@-M1TJ-N
WL@-@-AGJ-N
WL@-@-M1GJ-N
1 2 3 4 indicate the connector pin number. 4 1
WL@-@-M1TGJ-N
WL@-@-M1JB-N 3 2
WL@-@-M1TJB-N
WL@-@K43-N
WL@-@DGJ-N 4 1 2 3
WL@-@DTGJ-N

1 2 3 4 indicate the connector pin number.


Connector Pin Layout Diagram
AC Positioning piece *2 DC Positioning piece *2

2 2

3 1 3 1
4 4

Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher
than the leakage current. For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the
actuator rotates or is pushed down.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.

Connecting Sensor I/O connector cable (Socket)

Cable length
Type AC/DC Type Number of cable cores Model Applicable limit switch models
L (m)
2m XS2F-A421-DB0-F
2 WL@-@K13A-N
5m XS2F-A421-GB0-F
AC
2m XS2F-A421-D90-F WL@-@K43A-N
4
5m XS2F-A421-G90-F WL@-@-AGJ-N
M12 Screw (Straight)
2m XS2F-D421-DD0 WL@-@K13-N
5m XS2F-D421-GD0 WL@-@-M1J-N
2
2m XS2F-D421-DA0-F
DC WL@-@-M1GJ@-N
5m XS2F-D421-GA0-F
2m XS2F-D421-D80-F WL@-@K43-N
4 WL@-@-M1JB-N
5m XS2F-D421-G80-F WL@-@DGJ-N
M12 Smart click type (Straight)
2m XS5F-D421-D80-F
WL@-@-M1TJ-N
DC 4
WL@-@-M1TJB-N
5m XS5F-D421-G80-F

16
WL-N/WLM-N

Dimensions (Unit: mm)


XS2F-@421-@@0-@
XS2F-D421-@D0
L (Cable length)
40.7
6 dia.

14.9 dia.

DC AC 30 5
50
Wiring Diagram
Two-core model Four-core model
AC/DC Type
Model Wiring Diagram Model Wiring Diagram
Terminal No. Cable color of
core sheath
XS2F-A421-DB0-F 1
XS2F-A421-D90-F
AC 2
3 Brown
XS2F-A421-GB0-F 4 Blue XS2F-A421-G90-F

Terminal No. Cable color of


core sheath Terminal No. Cable color of
core sheath
XS2F-D421-DD0 1
2 1 Brown
3 Blue 2 White
XS2F-D421-GD0 4 Brown 3
4
Blue
Black
XS2F-D421-D80-F
DC Terminal No. Cable color of
core sheath
XS2F-D421-G80-F
XS2F-D421-DA0-F 1
2
Brown

XS2F-D421-GA0-F 3
4 Blue

XS5F-D421-@80-F Wiring Diagram


L (Cable length) Four-core model
40.7 AC/DC Type
6 dia. Model Wiring Diagram
Terminal No. Cable color of
14.9 dia. core sheath
XS5F-D421-D80-F 1 Brown
DC 2 White
30 5 XS5F-D421-G80-F 3
4
Blue
Black
50

17
WL-N/WLM-N

Environment-resistant Switches

Standard Switches

Adjustable rod lever


Actuator Roller lever R38 Adjustable roller lever
25 to 140mm
Item Pretravel (PT) Model Model Model
15±5° WLCA2-55-N WLCA12-55-N WLCL-55-N
Basic 25±5° WLCA2-255-N ----- -----
Airtight seal MAX20° WLCA2-2N55-N ----- -----
High-sensitivity 10° +2°
-1° WLG2-55-N ----- -----
High-precision 5° +2°0° WLGCA2-55-N ----- -----
15±5° WLCA2-139-N WLCA12-139-N WLCL-139-N
Molded Basic 25±5° WLCA2-2139-N ----- -----
terminals, MAX20° WLCA2-2N139-N ----- -----
-139 models High-sensitivity 10° +2°
-1° WLG2-139-N ----- -----
High-precision 5° +2°0° WLGCA2-139-N ----- -----
15±5° WLCA2-140-N WLCA12-140-N WLCL-140-N
Molded Basic 25±5° ----- ----- -----
terminals, MAX20° WLCA2-2N140-N ----- -----
-140 models High-sensitivity 10° +2°
-1° WLG2-140-N ----- -----
Hermetic High-precision 5° +2°0° ----- ----- -----
seal 15±5° WLCA2-141-N WLCA12-141-N -----
Molded Basic 25±5° ----- ----- -----
terminals, MAX20° ----- ----- -----
-141 models High-sensitivity 10° +2°
-1° WLG2-141-N ----- -----
High-precision 5° +2°0° WLGCA2-141-N ----- -----
15±5° WLCA2-RP60-N WLCA12-RP60-N WLCL-RP60-N
Basic 25±5° WLCA2-2RP60-N ----- -----
Anti-coolant MAX20° ----- ----- -----
High-sensitivity 10° +2°
-1° WLG2-RP60-N ----- -----
High-precision 5° +2°0° WLGCA2-RP60-N ----- -----
15±5° WLCA2-TH-N WLCA12-TH-N WLCL-TH-N
Basic 25±5° WLCA2-2TH-N WLCA12-2TH-N WLCL-2TH-N
Heat-resistant MAX20° WLCA2-2NTH-N WLCA12-2NTH-N WLCL-2NTH-N
High-sensitivity 10° +2°
-1° WLG2-TH-N WLG12-TH-N WLGL-TH-N
High-precision 5° +2°0° WLGCA2-TH-N ----- -----
15±5° WLCA2-TC-N WLCA12-TC-N WLCL-TC-N
Basic 25±5° WLCA2-2TC-N WLCA12-2TC-N WLCL-2TC-N
Low-temperature MAX20° WLCA2-2NTC-N WLCA12-2NTC-N WLCL-2NTC-N
High-sensitivity 10° +2°
-1° WLG2-TC-N WLG12-TC-N WLGL-TC-N
High-precision 5° +2°0° WLGCA2-TC-N ----- -----
15±5° WLCA2-RP-N WLCA12-RP-N WLCL-RP-N
Basic 25±5° ----- ----- -----
Corrosion-proof MAX20° ----- ----- -----
High-sensitivity 10° +2°
-1° WLG2-RP-N ----- -----
High-precision 5° +2°0° WLGCA2-RP-N ----- -----
15±5° WLCA2-P1-N WLCA12-P1-N WLCL-P1-N
Basic 25±5° ----- -----
Weather-proof
MAX20° ----- -----
High-sensitivity 10° +2°
-1° WLG2-P1-N WLG12-P1-N WLGL-P1-N
Note: The maximum cable length for a Hermetic Switch is 5 m.

Sealed top-roller Horizontal-roller Coil spring Resin rod


Horizontal plunger
Actuator plunger plunger (spring diameter: 6.5) (rod diameter: 8)

Model Model Model Model Model


Airtight WLD28-55-N WLSD-55-N WLSD2-55-N WLNJ-55-N WLNJ-255-N
Molded
terminals, WLD28-139-N WLSD-139-N WLSD2-139-N WLNJ-139-N WLNJ-2139-N
-139 models
Hermetic Molded
terminals, WLD28-140-N ----- WLSD2-140-N WLNJ-140-N WLNJ-2140-N
-140 models
Anti-coolant WLD28-RP60-N WLSD-RP60-N WLSD2-RP60-N WLNJ-RP60-N WLNJ-2RP60-N
Heat-resistant WLD28-TH-N WLSD-TH-N WLSD2-TH-N WLNJ-TH-N -----
Low-temperature ----- WLSD-TC-N WLSD2-TC-N WLNJ-TC-N -----
Corrosion-proof WLD28-RP-N WLSD-RP-N WLSD2-RP-N WLNJ-RP-N WLNJ-2RP-N
Note: The maximum cable length for a Hermetic Switch is 5 m.

18
WL-N/WLM-N

Environment-resistant Switches

Operation indicator Switches


Airtight Switches
Actuator
Adjustable rod lever:
Roller lever: R38 Adjustable roller lever
25 to 140mm

Indicator Item Pretravel (PT) Model Model Model


15±5° WLCA2-55LE-N WLCA12-55LE-N -----
Basic 25±5° WLCA2-255LE-N ----- -----
Neon lamp MAX20° WLCA2-2N55LE-N ----- -----
High-sensitivity 10° +2°
-1° WLG2-55LE-N ----- -----
High-precision 5° +2°0° WLGCA2-55LE-N ----- -----
15±5° WLCA2-55LD-N WLCA12-55LD-N WLCL-55LD-N
Basic 25±5° WLCA2-255LD-N ----- -----
LED MAX20° WLCA2-2N55LD-N ----- -----
High-sensitivity 10° +2°
-1° WLG2-55LD-N ----- -----
High-precision 5° +2°0° WLGCA2-55LD-N ----- -----

Sealed top-roller Horizontal-roller Coil spring Resin rod


Actuator Horizontal plunger
plunger plunger (spring diameter: 6.5) (rod diameter: 8)

Indicator Item Model Model Model Model Model


Neon lamp Basic WLD28-55LE-N ----- ----- ----- -----
LED Basic WLD28-55LD-N WLSD-55LD-N WLSD2-55LD-N WLNJ-55LD-N WLNJ-255LD-N

Hermetic Switches
Actuator
Roller lever: R38

Wiring specification NC wiring NO wiring


Item Pretravel (PT) Model Model
15±5° WLCA2-139LD2-N WLCA2-139LD3-N

Molded Basic 25±5° WLCA2-2139LD2-N WLCA2-2139LD3-N


terminals, MAX20° ----- -----
-139 models High-sensitivity 10° +2° ----- WLG2-139LD3-N
-1°

High-precision 5° +2°0° WLGCA2-139LD2-N WLGCA2-139LD3-N


15±5° WLCA2-141LD2-N WLCA2-141LD3-N
Basic 25±5° ----- -----
Molded
terminals, MAX20° ----- -----
-141 models
High-sensitivity 10° +2°
-1° WLG2-141LD2-N WLG2-141LD3-N
High-precision 5° +2°0° ----- -----
15±5° WLCA2-RP60LD2-N WLCA2-RP60LD3-N
Basic 25±5° WLCA2-2RP60LD2-N WLCA2-2RP60LD3-N
Anti-coolant MAX20° ----- -----
High-sensitivity 10° +2°
-1° WLG2-RP60LD2-N WLG2-RP60LD3-N
High-precision 5° +2°0° WLGCA2-RP60LD2-N WLGCA2-RP60LD3-N

Note: The maximum cable length for a Hermetic Switch is 5 m.

19
WL-N/WLM-N

Spatter-prevention Switches

Actuator
Roller lever: R38
Sealed top-roller
plunger
Double Nut Lever Allen-head Lever

Indicator Item Pretravel (PT) Model Model Model


Basic 15±5° WLCA2-LEAS-N WLCA2-LES-N WLD28-LES-N
Neon lamp High-sensitivity 10° +2°
-1° WLG2-LEAS-N WLG2-LES-N -----
High-precision 5° +2°0° ----- WLGCA2-LES-N -----
Basic 15±5° WLCA2-LDAS-N WLCA2-LDS-N WLD28-LDS-N
LED High-sensitivity 10° +2°
-1° WLG2-LDAS-N WLG2-LDS-N -----
High-precision 5° +2°0° ----- WLGCA2-LDS-N -----

Long-life Switches

Item Operation indicator (LED) *1


Basic 15±5° High-sensitivity 10° +2°
-1° High-precision 5° +2°0°
Actuator Model Model Model

Roller lever: R38,


screw terminals WLMCA2-LD-N WLMG2-LD-N WLMGCA2-LD-N

Roller lever, AC WLMCA2-LDK13A-N WLMG2-LDK13A-N WLMGCA2-LDK13A-N


2 conductors
direct-wired DC WLMCA2-LDK13-N WLMG2-LDK13-N WLMGCA2-LDK13-N
connector
AC WLMCA2-LDK43A-N WLMG2-LDK43A-N -----
4 conductors
DC WLMCA2-LDK43-N WLMG2-LDK43-N WLMGCA2-LDK43-N

Roller lever,
2 conductors DC WLMCA2-LD-M1J-N WLMG2-LD-M1J-N WLMGCA2-LD-M1J-N
pre-wired connector
*2

4 conductors DC WLMCA2-LD-DGJ-N WLMG2-LD-DGJ-N -----

*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(Ask your OMRON representative for information on 2-conductor models.)
*2. With 0.3-m cable.

20
WL-N/WLM-N

Individual Parts
Switches without Levers, Heads, and Actuators
General-purpose Parts
Switch without Head *1
Actuator only *2
Actuator Item Pretravel (PT) Set levers (with Actuators)
Model Model Model
15±5° WLCA2-N WLRCA2-N WL-1H1100-N
Basic 25±5° WLCA2-2-N WLRCA2-2-N WL-3H1100-N
Roller lever WL-1A100
MAX20° WLCA2-2N-N WLRCA2-2N-N WL-1H1100-N
High-sensitivity 10° +2°
-1° WLG2-N WLRG2-N WL-2H1100-N
15±5° WLCA12-N WLRCA2-N WL-1H2100-N
Adjustable roller Basic 25±5° WLCA12-2-N WLRCA2-2-N WL-3H2100-N
WL-2A100
lever MAX20° WLCA12-2N-N WLRCA2-2N-N WL-1H2100-N
+2°
High-sensitivity 10° -1° WLG12-N WLRG2-N WL-2H2100-N
15±5° WLCL-N WLRCA2-N WL-1H4100-N
Basic 25±5° WLCL-2-N WLRCA2-2-N WL-3H4100-N
Variable rod lever WL-4A100
MAX20° WLCL-2N-N WLRCA2-2N-N WL-1H4100-N
High-sensitivity 10° +2°
-1° WLGL-N WLRG2-N WL-2H4100-N
WLCA32-41-N WL-5H5100-N WL-5A100
WLCA32-42-N WL-5H5102-N WL-5A102
Fork lever lock Basic MAX55° WLRCA32-N
WLCA32-43-N WL-5H5104-N WL-5A104
WLCA32-44-N WL-5H5104-N WL-5A104
WLD18-N WL-7H100-N -----
MAX
Top plunger Basic WLD28-N ----- WL-7H400-N -----
1.7 mm
WLD38-N WL-7H300-N -----
WLSD-N WL-8H100-N -----
MAX
Horizontal plunger Basic WLSD2-N ----- WL-8H200-N -----
2.8 mm
WLSD3-N WL-8H300-N -----
WLNJ-N WL-9H100-N -----
20±10 mm
WLNJ-30-N WL-9H200-N -----
Flexible rod Basic -----
WLNJ-2-N WL-9H300-N -----
40±20 mm
WLNJ-S2-N WL-9H400-N -----

*1. The heads are not compatible with WL-series Switches.


*2. The same Actuators can be used for both WL and WL-N Switches.

Spatter-prevention Parts
Switch without Head *1
Actuator only *2
Actuator Lever Type Item Set levers (with Actuators)
Model Model Model
WLCA2-LES-N WLRCA2-LES-N
Allen-head bolt Basic
WLCA2-LDS-N WLRCA2-LDS-N WL-1H1100S-N WL-1A103S
lever
High-sensitivity WLG2-LDS-N WLRG2-LDS-N
Roller lever
WLCA2-LEAS-N WLRCA2-LES-N
Basic
Double nut lever WLCA2-LDAS-N WLRCA2-LDS-N WL-2H1100S-N WL-1A105S
High-sensitivity WLG2-LDAS-N WLRG2-LDS-N

*1. The heads are not compatible with WL-series Switches.


*2. The same Actuators can be used for both WL and WL-N Switches.

Covers with Indicators (See Note.)


General-purpose Parts Spatter-prevention Parts
Cover Cover only * Cover Cover only *
Item Model Item Model
Neon lamp WL-LE-N Neon lamp WL-LES-N
LED WL-LD-N LED WL-LDS-N

* The Covers are not compatible with WL-series Switches.

Note: The default setting is for light-ON when not operating.


Turn the lamp holder by 180° to change the setting to light-ON
when operating.

21
WL-N/WLM-N
Specifications
General-purpose/ Environment-resistant Switches
Ratings
Screw Terminals
Non-inductive load (A) Inductive load (A)
Rated voltage
Item Resistive load Lamp load Inductive load Motor load
(V)
NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 10 5 2.5
250 10 2 1 10 3 1.5
500 10 1.5 0.8 3 1.5 0.8
Basic or high-precision DC 8 10 6 3 10 6
14 10 6 3 10 6
30 6 4 3 6 4
125 0.8 0.2 0.2 0.8 0.2
250 0.4 0.1 0.1 0.4 0.1
AC 125 5
---- ---- ----
250 5
High-sensitivity Switches
DC 125 0.4
---- ---- ----
250 0.2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
5. For PC loads, use the microload models.

NC 30 A max.(15 A max. *)
Inrush current
NO 20 A max.(10 A max. *)
* For high-sensitivity switches.

Minimum applicable load 5 VDC 1 mA, resistive load, P level

Operation indicator Switches


Model Item Max. rated voltage Leakage current (mA)
125 AC Approx. 0.6
WL-LE-N Neon lamp
250 AC Approx. 1.9
10 to 24 VAC/DC Approx. 0.4
WL-LD-N LED
115 VAC/DC Approx. 0.5

Characteristics
Degree of protection IP67
Mechanical 15,000,000 operations min. *2
Durability *1
Electrical 750,000 operations min. *3
Operating speed 1 mm/s to 1 m/s (in case of WLCA2-N)
Mechanical 120 operations/minute min.
Operating frequency
Electrical 30 operations/minute min.
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone)
Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min
Dielectric strength Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *5
Shock Destruction 1,000 m/s2 max.
resistance Malfunction 300 m/s2 *5
Ambient operating temperature -10 to +80°C (with no icing) *6
Ambient operating humidity 35% to 95% RH
Weight Approx. 255 g (in case of WLCA2-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the highsensitivity switches models.
*1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*2. High-sensitivity Switches and Switches with Flexible Rod Actuators: 10 million operations min.
500,000 operations min. for weather-proof models.
*3. Durability is 500,000 operations min. for high-sensitivity models.
500,000 operations min. for weather-proof models.
Contact your OMRON representative for information on Environment-resistant Switches.
*4. Switches with Connectors: 1,500 V.
*5. Except Switches with Flexible Rod Actuators.
*6. For low-temperature models this is -40°C to +40°C (with no icing). For heatresistant models the range is +5°C to +120°C.

22
WL-N/WLM-N

Spatter-prevention Switches
Ratings
Screw Terminals
Non-inductive load (A) Inductive load (A)
Rated voltage
Item Resistive load Lamp load Inductive load Motor load
(V)
NC NO NC NO NC NO NC NO
WL@-LES-N AC 125 10 3 1.5 10 5 2.5
(Without high-sensitivity overtravel models) 250 10 2 1 10 3 1.5
AC 115 10 3 1.5 10 5 2.5
WL@-LDS-N DC 12 10 6 3 10 6
(Without high-sensitivity overtravel models) 24 6 4 3 6 4
115 0.8 0.2 0.2 0.8 0.2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
* Refer to the rating of a General-purpose / Weather-proof Switches type for the rating of a high-sensitivity overtravel type.

NC 30 A max.(15 A max. *)
Inrush current
NO 20 A max.(10 A max. *)
* For high-sensitivity switches.

Minimum applicable load 5 VDC 1 mA, resistive load, P level

Characteristics
Degree of protection IP67
Mechanical 15,000,000 operations min. *2
Durability *1
Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) *3
Operating speed 1 mm/s to 1 m/s (in case of WLCA2-LDS-N)
Mechanical 120 operations/minute min.
Operating frequency
Electrical 30 operations/minute min.
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone)
Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min
Dielectric strength Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
resistance Malfunction 300 m/s2
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35% to 95% RH
Weight Approx. 255 g (in case of WLCA2-LDS-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.
*1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*2. Durability is 10,000,000 operations min. for high-sensitivity models.
*3. Durability is 500,000 operations min. for high-sensitivity models.
500,000 operations min. for weather-proof models.
Contact your OMRON representative for information on Airtight Switches.
*4. Switches with Connectors: 1,500 V.

23
WL-N/WLM-N

Long-life Switches
Ratings
Screw Terminal Switches Direct-wired Connector and Pre-wired Connector Switches
Non-inductive load (A) Inductive load (A) Non-inductive load (A) Inductive load (A)
Rated Rated
Resistive Lamp Inductive Motor Resistive Lamp Inductive Motor
Item voltage Model voltage
load load load load load load load load
(V) (V)
NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
115 AC 10 3 1.5 10 5 2.5 115 AC 3 3 1.5 3 3 2.5
Basic or 12 DC 10 6 3 10 6 Basic or 12 DC 3 3 3 3
high-precision 24 DC 6 4 3 6 4 high-precision 24 DC 3 3 3 3
115 DC 0.8 0.2 0.2 0.8 0.2 115 DC 0.8 0.2 0.8 0.2
115 AC 5 — — — 115 AC 3 — — —
High-sensitivity High-sensitivity
115 DC 0.4 — — — 115 DC 0.4 — — —
Note: 1. The above figures are for steady-state currents.
NC 30 A max. (15 A max. *)
Inrush current 2. Inductive loads have a power factor of 0.4 min. (AC) and a
NO 20 A max. (10 A max. *) time constant of 7 ms max. (DC).
* For high-sensitivity overtravel models. 3. A lamp load has an inrush current of 10 times the steady-
state current.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 4. A motor load has an inrush current of 6 times the steady-
state current.

Characteristics
Degree of protection IP67
Mechanical 30,000,000 operations min.
30,000,000 operations min. (10 mA at 24
VDC, resistive load)
Durability *1 750,000 operations min. (3 A at 115 VAC,
Electrical
resistive load)
High-sensitivity Switches: 500,000 opera-
tions min. (3 A at 115 VAC, resistive load)
Operating speed 1 mm/s to 1 m/s (for WLMCA2-LD-N)
Operating Mechanical 120 operations/minute
frequency Electrical 30 operations/minute
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value for the built-in
Contact resistance
switch when tested alone)
Between ter-
minals of the 1,000 VAC (600 VAC), 50/60 Hz for 1 min
same polarity
Between cur-
Dielectric rent-carrying 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min
strength (50/ metal part *2
60 Hz for 1 and ground
min) Between
each terminal
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min
and non-cur-
*2
rent-carrying
metal part
Vibration re-
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
sistance
Shock resis- Destruction 1,000 m/s2 max.
tance Malfunction 300 m/s2 max.
Ambient operating tempera-
–10°C to +80°C (with no icing)
ture
Ambient operating humidity 35% to 95%RH
Weight Approx. 255 g (for WLMCA2-LD-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are for the
High-sensitivity Switches.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH. Contact
your OMRON sales representative for more detailed information
on other operating environments.
*2. Switches with Connectors: 1,500 V.

24
WL-N/WLM-N

General-purpose/ Environment-resistant/ Spatter-prevention Switches

Approved Standards
Agency Standard File No. Approved models
UL508
UL
CSA C22.2 No.14
Contact your OMRON representative for information Contact your OMRON representative for information
TÜV Rheinland EN60947-5-1
CCC (CQC) GB14048.5

Approved Standard Ratings


UL/cUL (UL508, CSA C22.2 No.14)
Specifications
Approved Standards
Indicator Sensor I/O connectors Item
A600
Basic Switches
1 A, 125 VDC
No Connector
B600
High-sensitivity or high-precision
0.5 A, 125 VDC
No indicator
C300
Pre-wired Connector (AC) Basic, high-sensitivity, or high-precision
3 A, 250 VAC
Pre-wired Connector (DC) Basic Switches 1 A, 125 VDC
Direct-wired Connector (DC) High-sensitivity or high-precision 0.5 A, 125 VDC
A300
Basic Switches
10 A, 250 VAC
No Connector
B300
Neon lamp High-sensitivity or high-precision
5 A, 250 VAC
C300
Pre-wired Connector (AC) Basic, high-sensitivity, or high-precision
3 A, 250 VAC
A150
Basic Switches 10 A, 115 VAC
1 A, 115 VDC
No Connector
B150
High-sensitivity or high-precision 5 A, 115 VAC
LED 0.5 A, 115 VDC
C150
Pre-wired Connector (AC) Basic, high-sensitivity, or high-precision
3 A, 115 VAC
Pre-wired Connector (DC) Basic Switches 1 A, 115 VDC
Direct-wired Connector (DC) High-sensitivity or high-precision 0.5 A, 115 VDC

A600 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 60 6
240 VAC 30 3
10 A 7,200 720
480 VAC 15 1.5
600 VAC 12 1.2

B600 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 30 3
240 VAC 15 1.5
5A 3,600 360
480 VAC 7.5 0.75
600 VAC 6 0.6

C300 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 15 1.5
2.5 A 1,800 180
240 VAC 7.5 0.75

A300 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 60 6
10 A 7,200 720
240 VAC 30 3

25
WL-N/WLM-N

B300 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 30 3
5A 3,600 360
240 VAC 15 1.5

A150 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 10 A 60 6 7,200 720

B150 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 5A 30 3 3,600 360

C150 Authentication conditions


Current (A) Volt-ampere (VA)
Rated voltage Energizing current
Make Break Make Break
120 VAC 2.5 A 15 1.5 1,800 180

TÜV (EN 60947-5-1)


(Certification Only for Switches with Ground Terminals and DC Switches with Connectors)
Specification
Authentication conditions With ground terminals
With DC Connector
No indicator Neon lamp LED
Working load category AC-15 DC-12 AC-15 AC-15 DC-12 DC-12
Rated working voltage (Ue) 250 V 48 V 250 V 115 V 48 V 48 V
Rated working current (Ie) 2A
Conditional short-circuit current 100 A
Short-circuit protective device (SCPD) 10 A, fuse type gG
Rated insulation voltage (Ui) 250 V 48 V
Rated impulse dielectric strength (Uimp) 4 kV 800 V
Pollution degree 3
Electric shock protection class Class I Class III

CCC (GB14048.5)
Specification
Authentication conditions
No indicator Neon lamp LED With DC Connector With AC Connector
Working load category AC-15 DC-13 AC-15 AC-15 DC-13 DC-13 AC-15
Rated working voltage (Ue) 250 V 48 V 250 V 250 V 48 V 48 V 250 V
Rated working current (Ie) 2A
Conditional short-circuit current 1000 A
Short-circuit protective device (SCPD) 10 A, fuse type gG
Rated insulation voltage (Ui) 250 V

26
WL-N/WLM-N
Structure and Nomenclature
Structure
General-purpose Switches: WLCA2-N

Actuator Head-mounting Screws


Roller
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.

Lever
Head
You can remove the two screws to
The lever is forged from corrosion-resistant
mount the switch in any of the four
aluminum alloy. It provides superior
possible orientations.
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be Shaft Section Seal
mounted in the opposite direction.) An oil seal is fitted on the inlet of the
shaft section to maintain a tight seal.

Roller Lever Bolt


Operational Plunger
Set Position Marker Plate You can change the direction of the
Set the indicator needle so operational plunger to electrically switch
that it is between protrusions the direction of operation between both
on the bearing section on the sides, left only, or right only.
marker plate after operation.
Head Built-in Switch
Set position marker plate Built-in switch with SPST-NO+NC
contact form.
Requires maintenance (excessive overtravel)
Proper range

Requires maintenance (insufficient overtravel)


Terminal Screws
Four, M3.5 screws
Proper range
Requires maintenance (excessive overtravel)

Cover Setscrew Conduit Opening *1


A combination Philips-slotted screw is used.
The conduit screw is a parallel screw
A retainer prevents the screw from falling
for G1/2 piping, and is used together
from the cover even when the screw is loose.
with an SC connector to maintain a
tight seal.
Cover
Cover Seal
High sealing performance is achieved. The
seal also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the Switch.
*1. The available conduit screws are Pg 13.5, M20 and 1/2-14 NPT.

27
WL-N/WLM-N

Indicators

Indicator Covers Indicator


The indicator covered if outsert molded The indicator is either a neon lamp or an
from diecast aluminum and has outstanding LED. Switches with LED indicators have a
sealing properties. built-in rectifier stack, so there is no
connection polarity.
Indicator Windows
Operating status (i.e., light-ON when
operating or light-ON when not operating)
depends on whether a neon lamp or an
LED is used. Contact Spring
Use the terminal screws on the built-in
switch to connect to the lamp terminals.
Light-ON when Operating/Not Operating
Lamp Holder A coil spring is used to make contact, so
Indicators can be switched from light-ON connecting to the lamp terminals is not
when operating and light-ON when not necessary.
operating, by simply rotating the indicator
holder by 180°.

Light-ON when Operating Light-ON when Not Operating

LED at top

Light-ON when Not Operating


LED at bottom

Operation Internal Circuits


Power

Built-in switch Neon lamp

Za
14 13
Contact spring
Light-ON when
WL-LE-N
operating *1 Resistor
12 11
Load

Internal
circuits
WL-LE-N
WL-LD-N
Power Rectifier stack
Contact spring
Internal
circuits Rated
Resistor current
Light-ON when Za diode
Load WL-LD-N
not operating *2 14 13
Zener
diode Resistor
12 11

Built-in switch LED

Note: 1. Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating
current is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.

28
WL-N/WLM-N

Environment-resistant Switches

Molding Specifications for Hermetic Switches : Molded parts

WL@-139-N WL@-140-N WL@-141-N


Oil seal
Head cap

Airtight Airtight
Standard
built-in switch built-in switch
built-in switch

WL@-145-N WL@-RP40-N WL@-RP60-N


Oil seal
Head cap

Airtight Airtight Airtight


built-in switch built-in switch built-in switch
* Fluorine rubber
is used for all
rubber parts.

Model Cable specifications Connector type


WL@-139-N Resin cap
WL@-140-N
WL@-141-N Standard 5-m VCT cable, with high flexibility and good Metal connector
WL@-145-N anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
WL@-RP40-N Resin connector *
WL@-RP60-N Resin cap

* The connector can be removed, so it is possible to use flexible conduit for the cable.

29
WL-N/WLM-N

Spatter-prevention Switches: WLCA2-LES-N

Actuator
Roller, Roller Axis
Using stainless steel prevents
spatter from adhering.
Screws
Operating Lever Externally visible screws on the head and
A baking finish is applied to the surface
cover are made of stainless steel to prevent
so that any adhering spatter is easily
spatter adherence.
removed.

Roller Lever Bolt Head Cap


Stainless steel construction to prevent Using fluororesin prevents spatter from
spatter adherence. adhering.
Double nut models are also available. * Spatter means the zinc powder produced
when welding.
Adhering spatter to the Limit Switch may
cause malfunction of lever or lamp cover.

The lack of gap prevents spatter


powder from clogging.

30
WL-N/WLM-N

Long-life Switches

Head Head Cap


The head cap helps prevent the entry of cutting
You can remove the two screws to mount the head in
chips.You can use the protrusion on the cap to
any of the four possible directions.
confirm the set position.

Actuator
Shield Structure
Roller
A head cap and oil seal form a double-seal structure. The roller is made of self-lubricating sintered
Excellent durability and reliability are ensured. stainless steel.
It provides superior resistance to wear.
Lever
Oil seal The lever is forged from anti-corrosive aluminum
alloy. It provides superior corrosion resistance and
outstanding strength. With a roller lever actuator,
the actuator position can be set anywhere within
360°. (The lever cannot be mounted in the opposite
direction.)

Head cap

Operating Plunger
PEEK resin is used. It provides superior resistance to
wear. You can change the mounting direction to use
any one of the three operating directions (both sides,
Built-in Switch left side, or right side).
Built-in switch with an
SPST-NO+NC contact form.
Cover Seal
High sealing performance is achieved. The seal also
serves as a spacer.
Terminal Screws
Four, M3.5 screws. There is no troublesome insulating paper, making it
easy to work with the Switch.

Cover Setscrew
Conduit Opening Cover A combination Philips-slotted screw is used.
In addition to parallel threads for G1/2 tubing, A retainer prevents the screw from falling
direct-wired and pre-wired connectors have been from the cover even when the screw is loose.
added to the series.

31
WL-N/WLM-N
Dimensions and Operating Characteristics (Unit: mm)

General-purpose Switches

Standard Switches
Switches with Roller Lever Actuators
Basic, High-sensitivity, and High-precision Switches
Roller lever R38 Roller lever R50
Basic High-sensitivity High-precision Basic
WLCA2-N WLG2-N WLGCA2-N WLCA2-7-N
WLCA2-2-N 60 max. 67.2 max.
53±1.5 58.1±1.5
WLCA2-2N-N 17.5×7 dia. * 41.5±1.5 17.5×15 dia. * 41.5±1.5
40±1.5 36±1.5
25.4
13.1 25.4
Two, M3.5 13.1
12.7 R50 Two, M3.5
R38 12.7
Four, 5.2 dia.
M5 25.4 holes 25.4
14.7 Allen-head bolt
(125) (137) 14.7
M5
Four, 5.2 dia. holes Allen-head bolt
58.7±0.2 68.7 68.7
Three, M4 58.7±0.2
Three, M4

5 5
21.6 Four, M6
(4.9) 21.6
Depth: 15 min. (4.9) Four, M6
(15.1) 29.2±1.2 (15.1) JIS B 0202 G½
JIS B 0202 G½ 42 max. 29.2±1.2 Depth: 15 min
30.2±0.2 30.2±0.2 42 max.
40±0.7 53.2±0.8
40±0.7 53.2±0.8
* Stainless sintered roller * Stainless sintered roller
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.

Roller lever R63 Adjustable roller lever


Basic Basic High-sensitivity
60 max.
WLCA2-8-N 53±1.5 WLCA12-N WLG12-N
41.5±1.5
17.5×7 dia. *
40±1.5
WLCA12-2-N 67 max.
17.5×7 dia. *
WLCA12-2N-N 60±1.5
25.4 41.5±1.5
R63 13.1 25.4
Two, M3.5 13.1
Two, M3.5
M5 12.7
Adjustable range: 12.7
Allen-head bolt 25 to 89
(150)
Four, 5.2 dia. Four, 5.2 dia. holes
25.4 25.4
holes M5
14.7
14.7 Allen-head
bolt

58.7±0.2 Three, M4 68.7 68.7


58.7±0.2 Three, M4

5
5
(4.9) 21.6
Four, M6 (4.9) 21.6 Four, M6
(15.1) (15.1)
JIS B 0202 G½ 29.2±1.2 Depth: 15 min Depth: 15 min
30.2±0.2 29.2±1.2
42 max. 30.2±0.2
JIS B 0202 G½ 42 max.
40±0.7 53.2±0.8 40±0.7
65.2±0.8
* Stainless sintered roller
* Stainless sintered roller

Only the external appearance of the set position


indicator plate varies on high-sensitivity models.

Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.

Model
WLCA2-N WLCA2-2-N WLCA2-2N-N WLG2-N WLCA2-7-N WLCA2-8-N WLGCA2-N
Operating characteristics
Operating force OF max. 13.34 N 13.34 N 13.34 N 13.34 N 10.2 N 8.04 N 13.34 N
Release force RF min. 1.18 N 1.18 N 1.18 N 1.18 N 0.9 N 0.71 N 1.18 N
+2° +2°
Pretravel PT 15±5° 25±5° 20° max. 10° −1° 15±5° 15±5° 5° 0°
Overtravel OT min. 70° 60° 70° 80° 70° 70° 80°
Movement Differential MD max. 12° 16° 10° 7° 12° 12° 3°

Model WLCA12-2-N
WLCA12-N *1 WLG12-2N-N *1 WLG12-N *1
Operating characteristics *1
Operating force OF max. 13.34 N 13.34 N 13.34 N 13.34 N
Release force RF min. 1.18 N 1.18 N 1.18 N 1.18 N
+2°
Pretravel PT 15±5° 25±5° 20° max. 10° −1°
Overtravel OT min. 70° 60° 70° 80°
Movement Differential MD max. 12° 16° 10° 7°
*1. The operating characteristics for WLCA12-N, WLCA12-2-N, WLCA12-2N-N, and WLG12-N are measured at the lever length of 38 mm.

32
WL-N/WLM-N

Switches with Roller Lever Actuators


Basic, High-sensitivity, and Protective Switches
Adjustable rod lever 25 to 140 mm Adjustable rod lever
Basic High-sensitivity Basic
WLCL-N WLGL-N WLCAL4-N 67 max.
8
WLCL-2-N 9
3.2 dia. *
WLCL-2N-N 55 max.
46±1.5
3±0.2dia. 12.8 54.5±1.5
(length:160) * 41.5±1.5
Adjustable range: 41.5±1.5
Adjustable range: 25.4 350 to 380 25.4
25 to 140 M8 13.1 13.1
Two, M3.5 Allen-head
set screw 12.7 12.7

Four, 5.2 dia. 65


holes 25.4 25.4
14.7 M5
14.7
M5 Allen-head
Allen-head set screw
set screw Four, 5.2 dia.
Three, M4 68.7 holes 68.7
58.7±0.2 58.7±0.2
Three, M4

5 5
(4.9) 21.6 Four, M6 (4.9) 21.6 Four, M6
(15.1) (15.1) JIS B 0202 G½ Depth: 15 min.
Depth: 15 min. 29.2±1.2
30.2±0.2 JIS B 0202 G½ 29.2±1.2 30.2±0.2
42 max. 42 max.
40±0.7 40±0.7
* Stainless steel rod
* Stainless steel rod

Only the external appearance of the set position


indicator plate varies on high-sensitivity models.

Rod spring lever 67max. Fork lever lock


Basic Protective Switches The WLCA32-41-N is shown in the following
diagram.
WLCAL5-N WLCA32-41-N
WLCA32-42-N
7.5
WLCA32-43-N
2.3 dia. * WLCA32-44-N 62.5 max.
428.5±2
56.4±3.5
54.5±1.5 Two, 17.5×7 dia. * 42.8±3.5
25.4 13.1
12.7
41.5±1.5 90°±3°
R38
65 25.4
13.1 Two, M3.5
34.1
12.7
14.7
11 Four, 5.2 25.4 (125) M5 Allen-head
dia. holes set screw
14.7
Four, 5.2 dia.
M5 58.7±0.2 holes 68.7
Allen-head
Three, M4
bolt
68.7
58.7±0.2
Three, M4
5 (15.1) 21.6
JIS B 0202 G½ 4-M6
5 (4.9) Four, M6
(4.9) 21.6 Four, M6 30.2±0.2 29.2±1.2 Depth: 15 min.
(15.1)
JIS B 0202 G½ 29.2±1.2 Depth: 15 min. 40±0.7 42 max.
30.2±0.2 42 max.
40±0.7 * Plastic Roller
* Piano wire (The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.)

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.

Model
WLCL-N *1 WLCL-2-N *1 WLCL-2N-N *1 WLGL-N *1 WLCAL4-N *2 WLCAL5-N
Operating characteristics
Operating force OF max. 1.39 N 1.39 N 1.39 N 2.84 N 0.98 N 0.9 N
Release force RF min. 0.27 N 0.27 N 0.27 N 0.25 N 0.15 N 0.09 N
+2°
Pretravel PT 15±5° 25±5° 20° max. 10° −1° 15±5° 15±5°
Overtravel OT min. 70° 60° 70° 80° 70° 70°
Movement Differential MD max. 12° 16° 10° 7° 12° 12°
Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is
mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring.
*1. The operating characteristics for WLCL-N, WLCL-2-N, WLCL-2N-N, and WLGL-N are measured at the lever length of 140 mm.
*2. The operating characteristics of WLCAL4-N are measured at a rod length of 380 mm.

Model
WLCA32-41 to 44-N
Operating characteristics
Force necessary to reverse the direction of the lever max. 11.77 N
Movement until the lever reverses 50±5°
Movement until switch operation max. 55°
Movement after switch operation min. 35°

33
WL-N/WLM-N

Switches with Plunger Actuators


Basic Switches
Sealed Top Plunger Horizontal Plunger PT OP
WLD18-N 10 dia. 13.1 WLSD-N 46.6±0.8 13.1
25.4 Two, M3.5
PT 12.9 12.7
R1 *
25 dia. *2 R1

OP Two, M3.5
27.5
17.8 9.3 dia. *1

Four, 5.2 dia. holes (96.2) Four, 5.2 dia. holes


58.7±0.2 68.7 58.7±0.2 68.7
Three, M4 Three, M4

5 5
(15.1) 21.6 Four, M6 *1. Stainless steel plunger (15.1) 21.6 Four, M6
(4.9) JIS B 0202 G½ *2. Cosmetic nuts (4.9) JIS B 0202 G½
* Stainless steel plunger 30.2±0.2 29.2±1.2 Depth: 15 min 30.2±0.2 29.2±1.2 Depth: 15 min
40±0.7 42 max. 40±0.7 42 max.

Sealed Top-roller Plunger Horizontal-roller Plunger


13.1
WLD28-N PT 14.3 dia.×5 *
WLSD2-N PT OP
12.9 55.7±0.8
25.4 Two, M3.5 13.1
12.7
25 dia. *2
OP Two, M3.5
27.5
17.8
17 dia.×4.6 *1

Four, 5.2 dia. holes (96.2) Four, 5.2 dia. holes


58.7±0.2 68.7 58.7±0.2 68.7
Three, M4 Three, M4

5 5
(15.1) JIS B 0202 G½ 21.6 Four, M6 *1. Stainless sintered roller (15.1) 21.6 Four, M6
*Stainless sintered roller (4.9) Depth: 15 min (4.9) JIS B 0202 G½
30.2±0.2 29.2±1.2 *2. Cosmetic nuts 30.2±0.2 29.2±1.2 Depth: 15 min
40±0.7 42 max. 40±0.7 42 max.

Sealed Top-ball Plunger Horizontal-ball Plunger


13.1
WLD38-N PT
15.5 dia.
1/2" dia. * 12.9
WLSD3-N PT OP
46.6±0.8 13.1
25.4 Two, M3.5
12.7
25 dia. *2
OP Two, M3.5
15.5 dia. 27.5
17.8
1/2" dia. *1

Four, 5.2 dia. holes (96.2) Four, 5.2 dia. holes


58.7±0.2 68.7 58.7±0.2 68.7
Three, M4 Three, M4

5 5
* Stainless steel ball (15.1) 21.6 Four, M6 * 1. Stainless steel ball (15.1) 21.6 Four, M6
(4.9) JIS B0202 G½ (4.9) JIS B0202 G½
30.2±0.2 29.2±1.2 Depth: 15 min * 2. Cosmetic nuts 30.2±0.2 29.2±1.2 Depth: 15 min
40±0.7 42 max. 42 max.
40±0.7

Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.

Model
WLD18-N WLD28-N WLD38-N WLSD-N WLSD2-N WLSD3-N
Operating characteristics
Operating force OF max. 26.67 N 16.67 N 16.67 N 40.03 N 40.03 N 40.03 N
Release force RF min. 8.92 N 4.41 N 4.41 N 8.89 N 8.89 N 8.89 N
Pretravel PT max. 1.7 mm 1.7 mm 1.7 mm 2.8 mm 2.8 mm 2.8 mm
Overtravel OT min. 6.4 mm 5.6 mm 5.6 mm 6.4 mm 5.6 mm 4 mm
Movement Differential MD max. 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm
Operating position OP 34±0.8 mm 44±0.8 mm 44.5±0.8 mm 40.6±0.8 mm 54.2±0.8 mm 54.1±0.8 mm
Total travel position TTP max. 29.5 mm 39.5 mm 41 mm — — —

34
WL-N/WLM-N

Switches with Flexible Rod Actuators


Basic Switches
Coil Spring Coil Spring (Multi-wire)
WLNJ-N WLNJ-30-N
*1
PT 6.5 dia. *1
PT 4.8 dia.

*3
*3

*2
*2
(107)
(107)
140±2.5
140±2.5
13.1
13.1 12.9
12.9
Two, M3.5
Two, M3.5
33.7±0.8
33.7±0.8

Four, 5.2 dia. holes


Four, 5.2 dia. holes
58.7±0.2 68.7 58.7±0.2 68.7
Three, M4
Three, M4

5
(15.1) 21.6 Four, M6 5
(4.9) JIS B 0202 G½ (15.1) 21.6 Four, M6
30.2±0.2 29.2±1.2 Depth: 15 min (4.9) JIS B 0202 G½
30.2±0.2 29.2±1.2 Depth: 15 min
40±0.7 42 max.
40±0.7 42 max.
*1. Do not operate the Switch in the direction of the axial center. *1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring. *2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring.

Resin Rod Steel Wire


WLNJ-2-N *1 WLNJ-S2-N *1
1 dia
PT 8 dia. PT

*3
*3

*2

(95.4)
(159) *2
140±2.5
13.1 193±2.5
26 dia.
12.9 13.1
12.9

Two, M3.5
44.6±0.8 Two, M3.5

33.7±0.8

Four, 5.2 dia. holes


Four, 5.2 dia. holes
58.7±0.2 68.7
58.7±0.2 68.7
Three, M4
Three, M4

5
(15.1) 21.6 Four, M6 5
(4.9) JIS B0202 G½ (15.1) 21.6 Four, M6
30.2±0.2 29.2±1.2 Depth: 15 min (4.9) JIS B 0202 G½
30.2±0.2 29.2±1.2 Depth: 15 min
40±0.7 42 max.
40±0.7 42 max.

*1. Do not operate the Switch in the direction of the axial center. *1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod *2. Stainless steel wire.
*3. The range for operation is 1/3rd of the overall rod length from the end of the rod. *3. The range for operation is 1/3rd of the overall wire length from the end of the wire.

Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.

Model
WLNJ-N WLNJ-30-N WLNJ-2-N WLNJ-S2-N
Operating characteristics
Operating force OF Max. 1.47 N 1.47 N 1.47 N 0.28 N
Pretravel PT 20±10 mm 20±10 mm 40±20 mm 40±20 mm

* These values are for the top end of the spring, rod, or wire.

35
WL-N/WLM-N

Sensor I/O connector Switches


(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 16.)

Switches with Roller Lever Actuators


Switches with Direct-wired Connectors Switches with Pre-wired Connectors
Basic Switches Basic Switches
WLCA2-LDK13-N WLCA2-LD-M1J-N
High-sensitivity Switches High-sensitivity Switches
WLG2-LDK13-N WLG2-LD-M1J-N
High-precision Switches High-precision Switches 60 max.
WLGCA2-LDK13-N WLGCA2-LD-M1J-N 53±1.5
41.5±1.5
17.5×7 dia. *
60 max. 40±1.5
25.4
53±1.5
17.5×7 dia. * 41.5±1.5 13.1
40±1.5 Two, M3.5
12.7
25.4 R38
13.1 Four, 5.2 dia. holes
Two, M3.5 12.7 25.4
R38 14.7 M5
(125) Allen-head bolt
Four, 5.2 dia. holes 25.4
14.7 M5
Allen-head 68.7
58.7±0.2 Three, M4
(125) bolt

58.7±0.2 68.7
Three, M4 5
(4.9)
5 Four, M6
(15.1)
SC-1M Depth: 15 min
12.5
(4.9) Four, M6
(15.1) 29.2±1.2 Depth: 15 min. 300 +100
−50
30.2±0.2 42 max.
M12×1
40±0.7 53.2±0.8
XS2H-D421 29.2±1.2
* Stainless sintered roller
30.2±0.2
42 max.
40±0.7
53.2±0.8
* Stainless sintered roller

The only difference in the shape for High-sensitivity and The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate. High-precision Switches is the set position marker plate.

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.


2. The following diagrams are for a indicator-equipped models.

Model High-sensitivity High-precision


Basic Switches
Operating characteristics Switches Switches
Operating force OF max. 13.34 N 13.34 N 13.34 N
Release force RF min. 1.18 N 1.18 N 1.18 N
+2° +2°
Pretravel PT 15±5° 10° −1° 5° 0°
Overtravel OT min. 70° 80° 80°
Movement Differential MD max. 12° 7° 3°

Operation indicator Switches

Roller lever
WLCA2-LD-N 60 max.
53±1.5
WLCA2-LE-N 17.5×7 dia. * 41.5±1.5
40±1.5
25.4
13.1
Two, M3.5 12.7
R38 Four, 5.2 dia. holes

25.4
14.7
(125) M5
Allen-head bolt

58.7±0.2 68.7
Three, M4

Model WLCA2-LD-N
5
21.6
Operating characteristics WLCA2-LE-N
(4.9) Operating force OF max. 13.34 N
(15.1) JIS B 0202 G½ 29.2±1.5 Four, M6
42 max. Depth: 15 min Release force RF min. 1.18 N
30.2±0.2 53.2±0.8
40±0.7
Pretravel PT 15±5°
Overtravel OT min. 70°
* Stainless sintered roller
Movement Differential MD max. 12°

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.

36
WL-N/WLM-N

Spatter-prevention Switches
Switches with Roller Lever Actuators
Switches with Screw Terminals Switches with Pre-wired Connectors
Basic Switches WLCA2-@S-M1J-N
WLCA2-@S-N 60 max.
53±1.5
High-sensitivity Switches 17.5×7 dia. * 41.5±1.5
WLG2-@S-N 40±1.5
25.4
High-precision Switches 60 max.
Two, M3.5
13.1
53±1.5
WLGCA2-@S-N 17.5×7 dia. * 41.5±1.5 R38 12.7
40±1.5 Four, 5.2 dia. holes
25.4 25.4
13.1 M5
Two, M3.5 14.7
12.7 (125) Allen-head bolt
R38
Four, 5.2 dia. holes
Fluorine
25.4 58.7±0.2 resin cap 68.7
14.7 Three, M4
(125) M5
Allen-head bolt
Fluorine 5
resin cap
58.7±0.2 68.7 (4.9) Four, M6
Three, M4
(15.1) Depth: 15 min

5 SC-1M

(4.9) 300 +100


−50
21.6
(15.1) JIS B 0202 G½ Four, M6
29.2±1.2
30.2±0.2 Depth: 15 min
42 max.
40±0.7 53.2±0.8 XS2H-D421 29.2±1.2
* Stainless sintered roller 30.2±0.2
42 max.
40±0.7
53.2±0.8
The only difference in the shape for High-sensitivity and * Stainless sintered roller
High-precision Switches is the set position marker plate.

Switches with Sealed Top-roller Plungers


Switches with Screw Terminals Switches with Pre-wired Connectors
WLD28-@S-N WLD28-@S-M1J-N
13.1
PT Rubber cap 12.9
14.3 dia.×5 *
(fluorine rubber)
13.1 Two, M3.5
PT 14.3 dia.×5 * OP
Rubber cap 12.9
(fluorine rubber)
Two, M3.5
OP
Four, 5.2 dia. holes
58.7±0.2 68.7
Three, M4
Four, 5.2 dia. holes
58.7±0.2 68.7 5
Three, M4
Four, M6
SC-1M Depth: 15 min

5 (15.1) 21.6
JIS B 0202 G½ Four, M6
(4.9) Depth: 15 min +100
30.2±0.2 29.2±1.2 300 −50

40±0.7 42 max. XS2H-D421

*Stainless sintered roller


(15.1)
(4.9) 29.2±1.2
30.2±0.2 42 max.
40±0.7

*Stainless sintered roller

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.


2. The above diagrams are for Indicator-equipped Switches.

Actuator Switches with Roller Lever Actuators


Switches with Sealed Top-
High-sensitivity High-precision roller Plungers
Operating characteristics Basic Switches
Switches Switches
Operating force OF max. 13.34 N 13.34 N 13.34 N 16.67 N
Release force RF min. 1.18 N 1.18 N 1.18 N 4.41 N
+2° +2°
Pretravel PT 15±5° 10° −1° 5° 0° Max.1.7 mm
Overtravel OT min. 70° 80° 80° 5.6 mm
Movement Differential MD max. 12° 7° 3° 1 mm
Operating position OT — — — 44±0.8 mm
Total travel position TTP max. — — — 39.5 mm

37
WL-N/WLM-N

Long-life Switches
Switches with Roller Lever Actuators
Switches with Screw Terminals Switches with Direct-wired Connectors
Basic Switches Basic Switches
WLMCA2-LD-N WLMCA2-LDK13-N
High-sensitivity Switches High-sensitivity Switches
WLMG2-LD-N WLMG2-LDK13-N
60 max. 60 max.
High-precision Switches 53±1.5 High-precision Switches 53±1.5
41.5±1.5
WLMGCA2-LD-N 40±1.5
WLMGCA2-LDK13-N 41.5±1.5
17.5 dia.×7 * 17.5 dia.×7 * 40±1.5
25.4 25.4
13.1 13.1
12.7 12.7
R38 Two, M3.5 Two, M3.5
R38
Four, 5.2 dia. holes 25.4 Four, 5.2 dia. holes 25.4
14.7 14.7
M5 Allen-head bolt M5 Allen-head bolt
Fluorine resin cap Fluorine resin cap
58.7±0.2 68.7 58.7±0.2 68.7
Three, M4 Three, M4

5
5 (15.1) 21.6 12.5
Four, M6 Four, M6
(4.9) Depth: 15 min (15.1) M12×1 Depth: 15 min
30.2±0.2 JIS B 0202 G½ 29.2±1.2 29.2±1.2
(4.9)
40±0.7 42 max. 30.2±0.2 42 max.
53.2±0.8 40±0.7 53.2±0.8
*Stainless sintered roller
*Stainless sintered roller
The only difference in the shape for High-sensitivity and The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate. High-precision Switches is the set position marker plate.

Switches with Pre-wired Connectors


Basic Switches
WLMCA2-LD-M1J-N
High-sensitivity Switches
WLMG2-LD-M1J-N 60 max.
High-precision Switches 53±1.5
41.5±1.5
WLMGCA2-LD-M1J-N 17.5 dia.×7 * 40±1.5
25.4
13.1
12.7
R38 Two, M3.5

Four, 5.2 dia. holes


25.4
14.7
M5 Allen-head bolt
Fluorine resin cap

58.7±0.2 68.7
Three, M4

5
Four, M6
SC-1M Depth: 15 min

+100
300 −50

XS2H-D421
(15.1)
(4.9) 29.2±1.2
30.2±0.2 42 max.
40±0.7 53.2±0.8
*Stainless sintered roller
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.


2. The above diagrams are for Indicator-equipped Switches.

Actuator Switches with Roller Lever Actuators


High-sensitivity High-precision
Operating characteristics Basic Switches
Switches Switches
Operating force OF max. 13.34 N 13.34 N 13.34 N
Release force RF min. 1.18 N 1.18 N 1.18 N
+2° +2°
Pretravel PT 15±5° 10° −1° 5° 0°
Overtravel OT min. 70° 80° 80°
Movement Differential MD max. 12° 7° 3°

38
WL-N/WLM-N

Actuators (Levers Only)


Lever: Only rotating lever models are illustrated.

WL-1A100 WL-1A115 WL-1A400 WL-1A118


Standard Lever Resin Roller Bearing Roller Nylon Roller:
Roller Width: 30 mm
17.5 dia. × 7, 17.9 17.5 dia. (length: 7) 17.9 17 dia. (length: 6) 16.9 17.5 dia. (length: 30) 40.2±0.8
sintered stainless steel roller 12.6 resin roller 12.6 bearing roller 12.1 Nylon roller
23.6

7.3-dia. 7.3-dia. 7.3-dia.


mounting mounting mounting 38 54.8
holes 38 54.8 holes 38 54.8 holes 38 54.8

7.3-dia. M5
M5 M5 M5
16 16 16 mounting 16 Allen-head bolt 11.4
Allen-head bolt 11.4 Allen-head bolt 11.4 Allen-head bolt 11.4
holes

WL-1A105 WL-1A103S WL-1A200 WL-1A300


Double Nuts Spatter Lever Length: 50 Lever Length: 63
Roller Width: 15
17.5 dia. × 7, 17.9 17.5 dia. (length: 7) 17.9 17.5 dia. × 15, 17.5 dia. × 7, 17.9
25.7
sintered stainless steel roller stainless steel roller 12.6 sintered stainless steel roller 16.6 sintered stainless steel roller 12.6
12.6

7.3-dia. 7.3-dia.
mounting mounting
38 54.8 38 54.8 7.3-dia.
holes holes
mounting 50 66.8
holes 7.3-dia. 63 79.8
mounting
holes
Two, M5 M5
16 Allenhead nut 16 Allen-head bolt 11.4
11.4 M5
and arm set screw 16 Allen-head bolt 11.4
M5
16 Allen-head bolt 11.4

WL-2A100 WL-2A111 WL-2A107 WL-2A108


Resin Roller Double Nuts Resin Roller
24.9±0.8
17.5 dia. × 7, 24.9±0.8 24.9±0.8 17.5 dia. × 7, 17.5 dia. (length: 7) M5
17.5 dia. (length: 7) 24.9±0.8
sintered stainless steel roller 19.7±0.8 resin roller 19.7±0.8 sintered stainless M5 resin roller Allen-head 19.7±0.8
steel roller Allen-head 19.7±0.8 bolt
Adjustable lever: Adjustable lever: bolt Adjustable lever:
Adjustable lever:
stainless steel stainless steel stainless steel
stainless steel
23
23 23
23 Adjustable
Adjustable Adjustable
range:
Adjustable range:
range:
range: 25 to 140
25 to 89 25 to 89
28 to 88
105.75 105.75
105.75
7.3-dia.
7.3-dia. mounting 155.75
7.3-dia.
mounting 7.3-dia. holes
mounting
holes mounting
M5 M5 holes
holes
Allen-head Allen-head
bolt bolt

12 12 Two, M5 Allen-head nut


12
16 16 and arm set screw
16

6.2
(15.8)

WL-2A122 WL-2A106 WL-2A130 WL-2A104


17.5 dia. × 7, 24.9±0.8 24.9±0.8 24.7±0.8 24.9±0.8
sintered stainless M5 17.5 dia. × 7, 17.5 dia. × 7,
Allen-head 19.7±0.8 19.7±0.8 19.5±0.8 50 dia. (length: 6) 19.7±0.8
steel roller sintered stainless sintered stainless
bolt Nylon roller
steel roller 9.1 steel roller
Adjustable lever: 3
stainless steel Adjustable lever:
23 stainless steel
(21.8)
Adjustable
range: 23
Adjustable (10)
25 to 140 R89.5
range: (10) Adjustable
25 to 89 from 42 to 89
7.3-dia.
mounting 105.75 (112) Three, 5.3 +0.2
155.75 0
holes dia. holes
7.3-dia. 7.3 dia.
mounting mounting holes 7.3-dia. M5
holes M5 mounting Allen-head
Allen-head holes bolt
bolt M5
15.9 Allen-head bolt
16
* Can be installed 23 12 23
20 on the rear side. 20
6.2 16
(15.8)

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.


Lever: Only rotating lever models are illustrated.

39
WL-N/WLM-N

WL-2A110 WL-2A105 WL-1A106 WL-1A110


34.2
50 dia. (length: 15) 34.5 49 dia. rubber roller 24.2 50 dia. (length: 6) 20.1±0.8 35 dia. (length: 6) 20.1±0.8
Nylon roller 24.4 Material: NBR 6 Nylon roller Nylon roller

R38
R38
23 Adjustable 23
Adjustable 122
from 41 to from 41 to M5
89 M5 Allen-head 7.3 dia.
78.5 16
Allen-head 7.3-dia. bolt mounting 11.5
bolt 16 mounting holes
11.5
holes
M5
7.3-dia. Allen-head 7.3-dia. M5
mounting bolt mounting Allen-head
holes holes bolt
16 16

WL-4A100 WL-4A201 WL-3A100 WL-3A106


Double Nut
9 9 3.2-dia.
2-dia. stainless 3.2-dia.
stainless stainless steel rod
3-dia. stainless steel for spring
steel rod
steel rod
7.3-dia. mounting
holes Adjustable Adjustable M5
Adjustable 7.3-dia.
M5 13 from 350 from 350 Allen-head
from mounting holes
Allen-head Adjustable to 380 8 to 380 bolt
25 to 140 from 270 to 8
bolt
160 290 400±2 400±2
M5
19 Allen-head
bolt
Actuator's
M8
Allen-head M8 center of 11 65±2 11 65±2
Allen-head rotation 7.5
set screw 7.5
set screw 6 6
11
11 7.3-dia. M5 7.3-dia. Two, M5
mounting 12.8 Allen-head 13.4 mounting Allenhead 13.4
12.8
holes bolt holes nut and arm
25.5 max. set screw 25.5 max.

WL-3A108 WL-3A200 WL-3A203 WL-4A112


3.2-dia. 2.3-dia. 8 dia. 9
stainless steel rod operation rod
Cap 4-dia. stainless
steel rod
50
7.3-dia.
Adjustable mounting holes
from 650 Adjustable M5
to 660 417.5±2
8 up to 141 Allen-head
437.5±2 Adhesive bolt
680±0.4 450±4 160±1.5
12.5 dia. max. 470±4 19
2.3 dia. 12.5
(95) rod dia.
max.
11 65±2
11 (95) M8
7.5 Allen-head
6 7.5
6 11 set screw
7.5
7.3-dia. 7.3-dia. 6 11
M5 M5
mounting 12.8 13.4 mounting 7.5 13
Allen-head Allen-head 7.3-dia.
holes holes M5
bolt bolt 24.6 max. mounting 7.5 Allen-head 13
25.5 max.
holes bolt
24.6 max.

WL-2A129 WL-5A101 WL-5A103 WL-5A105


15.8
Two, 17.5 dia. × 7, Two, 17.5 dia. × 7, Two, 17.5 dia. × 7,
Marking 3 17.7 17.7 6.7 sintered stainless steel rollers
17.7
R8 sintered stainless steel rollers 6.7 sintered stainless steel rollers
12.4 12.4 12.4
1.3 1.3
(18.5)
90° 90° 90°
Three, 5.2
dia. holes 7.3 dia. 7.3 dia. 7.3 dia. R38
R38 R38
84 54.8
95.3 54.8 54.8
7.3 dia.
(108) mounting
10 hole

10 M5 Allen-head M5 Allen-head M5 Allen-head


bolt 11 11 bolt 11
11.3 bolt

M5
15.9 Allen-head WL-5A100 has a plastic roller WL-5A102 has a plastic roller WL-5A104 has a plastic roller
bolt 22.1
20

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.


2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards.
Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur.

40
WL-N/WLM-N
Model Replacement Table
WL WL-N WL WL-N WL WL-N
WLCA2 WLCA2-N WLSD WLSD-N WLHAL5-LE WLCAL5-LE-N
WL01CA2 WLCA2-N WL01SD WLSD-N WLHAL5-LD WLCAL5-LD-N
WLH2 WLCA2-N WLSD2 WLSD2-N WLCA32-41LE WLCA32-41LE-N
WL01H2 WLCA2-N WL01SD2 WLSD2-N WLCA32-41LD WLCA32-41LD-N
WLG2 WLG2-N WLSD3 WLSD3-N WLCA32-42LE WLCA32-42LE-N
WL01G2 WLG2-N WL01SD3 WLSD3-N WLCA32-43LE WLCA32-43LE-N
WLCA2-2 WLCA2-2-N WLNJ WLNJ-N WLCA32-43LD WLCA32-43LD-N
WL01CA2-2 WLCA2-2-N WL01NJ WLNJ-N WLD-LE WLD18-LE-N
WLCA2-2N WLCA2-2N-N WLNJ-30 WLNJ-30-N WLD-LD WLD18-LD-N
WL01CA2-2N WLCA2-2N-N WL01NJ-30 WLNJ-30-N WLD2-LE WLD28-LE-N
WLGCA2 WLGCA2-N WLNJ-2 WLNJ-2-N WLD2-LD WLD28-LD-N
WL01GCA2 WLGCA2-N WL01NJ-2 WLNJ-2-N WLD3-LE WLD38-LE-N
WLCA2-7 WLCA2-7-N WLNJ-S2 WLNJ-S2-N WLD3-LD WLD38-LD-N
WL01CA2-7 WLCA2-7-N WL01NJ-S2 WLNJ-S2-N WLD28-LE WLD28-LE-N
WLCA2-8 WLCA2-8-N WLCA2-LE WLCA2-LE-N WLD28-LD WLD28-LD-N
WL01CA2-8 WLCA2-8-N WLCA2-LD WLCA2-LD-N WLSD-LE WLSD-LE-N
WLCA12 WLCA12-N WLH2-LE WLCA2-LE-N WLSD-LD WLSD-LD-N
WL01CA12 WLCA12-N WLH2-LD WLCA2-LD-N WLSD2-LE WLSD2-LE-N
WLH12 WLCA12-N WLG2-LE WLG2-LE-N WLSD2-LD WLSD2-LD-N
WL01H12 WLCA12-N WLG2-LD WLG2-LD-N WLSD3-LE WLSD3-LE-N
WLG12 WLG12-N WLCA2-2LE WLCA2-2LE-N WLSD3-LD WLSD3-LD-N
WL01G12 WLG12-N WLCA2-2LD WLCA2-2LD-N WLNJ-LE WLNJ-LE-N
WLCA12-2 WLCA12-2-N WLCA2-2NLE WLCA2-2NLE-N WLNJ-LD WLNJ-LD-N
WL01CA12-2 WLCA12-2-N WLCA2-2NLD WLCA2-2NLD-N WLNJ-30LE WLNJ-30LE-N
WLCA12-2N WLCA12-2N-N WLGCA2-LE WLGCA2-LE-N WLNJ-30LD WLNJ-30LD-N
WL01CA12-2N WLCA12-2N-N WLGCA2-LD WLGCA2-LD-N WLNJ-2LE WLNJ-2LE-N
WLCL WLCL-N WLCA2-7LE WLCA2-7LE-N WLNJ-2LD WLNJ-2LD-N
WL01CL WLCL-N WLCA2-7LD WLCA2-7LD-N WLNJ-S2LE WLNJ-S2LE-N
WLHL WLCL-N WLCA2-8LE WLCA2-8LE-N WLNJ-S2LD WLNJ-S2LD-N
WL01HL WLCL-N WLCA2-8LD WLCA2-8LD-N WLCA2-LDK13 WLCA2-LDK13-N
WLGL WLGL-N WLCA12-LE WLCA12-LE-N WLCA2-55LDK13 WLCA2-55LDK13-N
WL01GL WLGL-N WLCA12-LD WLCA12-LD-N WLCA2-LDK43 WLCA2-LDK43-N
WLCL-2 WLCL-2-N WLH12-LE WLCA12-LE-N WLCA2-55LDK43 WLCA2-55LDK43-N
WLCL-2N WLCL-2N-N WLH12-LD WLCA12-LD-N WLD2-LDK13 WLD28-LDK13-N
WL01CL-2N WLCL-2N-N WLG12-LE WLG12-LE-N WLD2-55LDK13 WLD28-55LDK13-N
WLHAL4 WLCAL4-N WLG12-LD WLG12-LD-N WLD2-LDK43 WLD28-LDK43-N
WLHAL5 WLCAL5-N WLCA12-2LE WLCA12-2LE-N WLD2-55LDK43 WLD28-55LDK43-N
WLCA32-41 WLCA32-41-N WLCA12-2LD WLCA12-2LD-N WLH2-LDK13 WLCA2-LDK13-N
WL01CA32-41 WLCA32-41-N WLCA12-2NLE WLCA12-2NLE-N WLH2-55LDK13 WLCA2-55LDK13-N
WLCA32-42 WLCA32-42-N WLCA12-2NLD WLCA12-2NLD-N WLH2-LDK43 WLCA2-LDK43-N
WLCA32-43 WLCA32-43-N WLCL-LE WLCL-LE-N WLH2-55LDK43 WLCA2-55LDK43-N
WL01CA32-43 WLCA32-43-N WLCL-LD WLCL-LD-N WLG2-LDK13 WLG2-LDK13-N
WLCA32-44 WLCA32-44-N WLHL-LE WLCL-LE-N WLG2-55LDK13 WLG2-55LDK13-N
WL01CA32-44 WLCA32-44-N WLHL-LD WLCL-LD-N WLG2-LDK43 WLG2-LDK43-N
WLD WLD18-N WLGL-LE WLGL-LE-N WLG2-55LDK43 WLG2-55LDK43-N
WL01D WLD18-N WLGL-LD WLGL-LD-N WLGCA2-LDK13 WLGCA2-LDK13-N
WLD2 WLD28-N WLCL-2LE WLCL-2LE-N WLGCA2-55LDK13 WLGCA2-55LDK13-N
WL01D2 WLD28-N WLCL-2LD WLCL-2LD-N WLGCA2-LDK43 WLGCA2-LDK43-N
WLD3 WLD38-N WLCL-2NLE WLCL-2NLE-N WLGCA2-55LDK43 WLGCA2-55LDK43-N
WL01D3 WLD38-N WLCL-2NLD WLCL-2NLD-N WLCA2-LD-M1J WLCA2-LD-M1J-N
WLD28 WLD28-N WLHAL4-LE WLCAL4-LE-N WLCA2-55LD-M1J WLCA2-55LD-M1J-N
WL01D28 WLD28-N WLHAL4-LD WLCAL4-LD-N WLCA2-LD-M1GJ WLCA2-LD-M1GJ-N

41
WL-N/WLM-N

WL WL-N WL WL-N WL WL-N


WLCA2-55LD-M1GJ WLCA2-55LD-M1GJ-N WLH2-55LE WLCA2-55LE-N WLGCA2-139LD3 WLGCA2-139LD3-N
WLCA2-55LD-M1JB WLCA2-55LD-M1JB-N WLH2-139 WLCA2-139-N WLGCA2-140 Ask your OMRON representative.
WLCA2-LD-DGJ03 WLCA2-LD-DGJ-N WLH2-140 WLCA2-140-N WLGCA2-140LD2 Ask your OMRON representative.
WLCA2-55LD-DGJ03 WLCA2-55LD-DGJ-N WLH2-141 WLCA2-141-N WLGCA2-140LD3 Ask your OMRON representative.
WLCA2-LD-DK1EJ03 WLCA2-LD-DK1EJ-N WLH2-141LD3 WLCA2-141LD3-N WLGCA2-141 WLGCA2-141-N
WLCA2-55LD-DK1EJ03 WLCA2-55LD-DK1EJ-N WLH2-RP60 WLCA2-RP60-N WLGCA2-141LD3 WLGCA2-141LD3-N
WLD2-LD-M1J WLD28-LD-M1J-N WLH2-RP60LD3 WLCA2-RP60LD3-N WLGCA2-RP60 WLGCA2-RP60-N
WLD2-55LD-M1J WLD28-55LD-M1J-N WLH2-TH WLCA2-TH-N WLGCA2-RP60LD2 WLGCA2-RP60LD2-N
WLD2-LD-M1GJ WLD28-LD-M1GJ-N WLH2-TC WLCA2-TC-N WLGCA2-RP60LD3 WLGCA2-RP60LD3-N
WLD2-55LD-M1GJ WLD28-55LD-M1GJ-N WLH2-RP WLCA2-RP-N WLGCA2-TH WLGCA2-TH-N
WLD2-55LD-M1JB WLD28-55LD-M1JB-N WLH2-P1 WLCA2-P1-N WLGCA2-TC WLGCA2-TC-N
WLD2-LD-DGJ03 WLD28-LD-DGJ-N WLG2-55 WLG2-55-N WLGCA2-RP WLGCA2-RP-N
WLD2-LD-DK1EJ03 WLD28-LD-DK1EJ-N WLG2-55LD WLG2-55LD-N WLCA12-55 WLCA12-55-N
WLD2-55LD-DK1EJ03 WLD28-55LD-DK1EJ-N WLG2-55LE WLG2-55LE-N WLCA12-55LD WLCA12-55LD-N
WLH2-LD-M1J WLCA2-LD-M1J-N WLG2-139 WLG2-139-N WLCA12-55LE WLCA12-55LE-N
WLH2-LD-M1GJ WLCA2-LD-M1GJ-N WLG2-139LD3 WLG2-139LD3-N WLCA12-139 WLCA12-139-N
WLH2-LD-DGJ03 WLCA2-LD-DGJ-N WLG2-140 WLG2-140-N WLCA12-140 WLCA12-140-N
WLG2-LD-M1J WLG2-LD-M1J-N WLG2-140LD2 Ask your OMRON representative. WLCA12-141 WLCA12-141-N
WLG2-LD-M1GJ WLG2-LD-M1GJ-N WLG2-140LD3 Ask your OMRON representative. WLCA12-RP60 WLCA12-RP60-N
WLG2-55LD-M1GJ WLG2-55LD-M1GJ-N WLG2-141 WLG2-141-N WLCA12-TH WLCA12-TH-N
WLG2-LD-M1JB WLG2-LD-M1JB-N WLG2-141LD2 WLG2-141LD2-N WLCA12-TC WLCA12-TC-N
WLG2-55LD-M1JB WLG2-55LD-M1JB-N WLG2-141LD3 WLG2-141LD3-N WLCA12-RP WLCA12-RP-N
WLG2-LD-DGJ03 WLG2-LD-DGJ-N WLG2-RP60 WLG2-RP60-N WLCA12-P1 WLCA12-P1-N
WLG2-55LD-DGJ03 WLG2-55LD-DGJ-N WLG2-RP60LD2 WLG2-RP60LD2-N WLH12-TH WLCA12-TH-N
WLG2-LD-DK1EJ03 WLG2-LD-DK1EJ-N WLG2-RP60LD3 WLG2-RP60LD3-N WLH12-TC WLCA12-TC-N
WLG2-55LD-DK1EJ03 WLG2-55LD-DK1EJ-N WLG2-TH WLG2-TH-N WLH12-RP WLCA12-RP-N
WLGCA2-LD-M1J WLGCA2-LD-M1J-N WLG2-TC WLG2-TC-N WLH12-P1 WLCA12-P1-N
WLGCA2-55LD-M1J WLGCA2-55LD-M1J-N WLG2-RP WLG2-RP-N WLG12-TH WLG12-TH-N
WLGCA2-LD-M1GJ WLGCA2-LD-M1GJ-N WLG2-P1 WLG2-P1-N WLG12-TC WLG12-TC-N
WLGCA2-55LD-M1JB WLGCA2-55LD-M1JB-N WLCA2-255 WLCA2-255-N WLG12-RP WLG12-RP-N
WLGCA2-55LD-DGJ03 WLGCA2-55LD-DGJ-N WLCA2-255LD WLCA2-255LD-N WLG12-P1 WLG12-P1-N
WLCA2-55 WLCA2-55-N WLCA2-255LE WLCA2-255LE-N WLCA12-2TH WLCA12-2TH-N
WLCA2-55LD WLCA2-55LD-N WLCA2-2139 WLCA2-2139-N WLCA12-2TC WLCA12-2TC-N
WLCA2-55LE WLCA2-55LE-N WLCA2-2139LD2 WLCA2-2139LD2-N WLCA12-2NTH WLCA12-2NTH-N
WLCA2-139 WLCA2-139-N WLCA2-2139LD3 WLCA2-2139LD3-N WLCA12-2NTC WLCA12-2NTC-N
WLCA2-139LD2 WLCA2-139LD2-N WLCA2-2RP60 WLCA2-2RP60-N WLCL-55 WLCL-55-N
WLCA2-139LD3 WLCA2-139LD3-N WLCA2-2RP60LD2 WLCA2-2RP60LD2-N WLCL-55LD WLCL-55LD-N
WLCA2-140 WLCA2-140-N WLCA2-2RP60LD3 WLCA2-2RP60LD3-N WLCL-139 WLCL-139-N
WLCA2-140LD2 Ask your OMRON representative. WLCA2-2TH WLCA2-2TH-N WLCL-140 WLCL-140-N
WLCA2-140LD3 Ask your OMRON representative. WLCA2-2TC WLCA2-2TC-N WLCL-RP60 WLCL-RP60-N
WLCA2-141 WLCA2-141-N WLCA2-2N55 WLCA2-2N55-N WLCL-TH WLCL-TH-N
WLCA2-141LD2 WLCA2-141LD2-N WLCA2-2N55LD WLCA2-2N55LD-N WLCL-TC WLCL-TC-N
WLCA2-141LD3 WLCA2-141LD3-N WLCA2-2N55LE WLCA2-2N55LE-N WLCL-RP WLCL-RP-N
WLCA2-RP60 WLCA2-RP60-N WLCA2-2N139 WLCA2-2N139-N WLCL-P1 WLCL-P1-N
WLCA2-RP60LD2 WLCA2-RP60LD2-N WLCA2-2N140 WLCA2-2N140-N WLHL-TH WLCL-TH-N
WLCA2-RP60LD3 WLCA2-RP60LD3-N WLCA2-2NTH WLCA2-2NTH-N WLHL-TC WLCL-TC-N
WLCA2-TH WLCA2-TH-N WLCA2-2NTC WLCA2-2NTC-N WLHL-RP WLCL-RP-N
WLCA2-TC WLCA2-TC-N WLGCA2-55 WLGCA2-55-N WLHL-P1 WLCL-P1-N
WLCA2-RP WLCA2-RP-N WLGCA2-55LD WLGCA2-55LD-N WLGL-TH WLGL-TH-N
WLCA2-P1 WLCA2-P1-N WLGCA2-55LE WLGCA2-55LE-N WLGL-TC WLGL-TC-N
WLH2-55 WLCA2-55-N WLGCA2-139 WLGCA2-139-N WLGL-RP WLGL-RP-N
WLH2-55LD WLCA2-55LD-N WLGCA2-139LD2 WLGCA2-139LD2-N WLGL-P1 WLGL-P1-N

42
WL-N/WLM-N

WL WL-N WL WL-N WL WL-N


WLCL-2TH WLCL-2TH-N WLG2-LEAS WLG2-LEAS-N WLRCL WLRCA2-N
WLCL-2TC WLCL-2TC-N WLCA2-LDAS WLCA2-LDAS-N WLRG2 WLRG2-N
WLCL-2RP WLCL-2RP-N WLH2-LDAS WLCA2-LDAS-N WLRCA2-2 WLRCA2-2-N
WLCL-2NTH WLCL-2NTH-N WLG2-LDAS WLG2-LDAS-N WLRCA2-2N WLRCA2-2N-N
WLCL-2NTC WLCL-2NTC-N WLCA2-LES WLCA2-LES-N WLRCA32 WLRCA32-N
WLD2-55 WLD28-55-N WLH2-LES WLCA2-LES-N WLRCA2-LDS WLRCA2-LDS-N
WLD2-55LD WLD28-55LD-N WLG2-LES WLG2-LES-N WLRH2-LES WLRCA2-LES-N
WLD2-55LE WLD28-55LE-N WLGCA2-LES WLGCA2-LES-N WLRH2-LDS WLRCA2-LDS-N
WLD2-139 WLD28-139-N WLCA2-LDS WLCA2-LDS-N WLRG2-LDS WLRG2-LDS-N
WLD2-RP60 WLD28-RP60-N WLH2-LDS WLCA2-LDS-N WLRGCA2-LES WLRGCA2-LES-N
WLD2-TH WLD28-TH-N WLG2-LDS WLG2-LDS-N
WLD2-TC WLD28-TC-N WLGCA2-LDS WLGCA2-LDS-N
WLD2-RP WLD28-RP-N WLD28-LES WLD28-LES-N
WLD28-55 WLD28-55-N WLD28-LDS WLD28-LDS-N
WLD28-55LD WLD28-55LD-N WLMCA2-LD WLMCA2-LD-N
WLD28-55LE WLD28-55LE-N WLMCA2-LDK13A WLMCA2-LDK13A-N
WLD28-139 WLD28-139-N WLMCA2-LDK13 WLMCA2-LDK13-N
WLD28-140 WLD28-140-N WLMCA2-LDK43A WLMCA2-LDK43A-N
WLD28-RP60 WLD28-RP60-N WLMCA2-LDK43 WLMCA2-LDK43-N
WLD28-TH WLD28-TH-N WLMCA2-LD-M1J WLMCA2-LD-M1J-N
WLD28-RP WLD28-RP-N WLMCA2-LD-DGJ03 WLMCA2-LD-DGJ-N
WLSD-55 WLSD-55-N WLMGCA2-LD WLMGCA2-LD-N
WLSD-55LD WLSD-55LD-N WLMGCA2-LDK13A WLMGCA2-LDK13A-N
WLSD-139 WLSD-139-N WLMGCA2-LDK13 WLMGCA2-LDK13-N
WLSD-RP60 WLSD-RP60-N WLMGCA2-LDK43A WLMGCA2-LDK43A-N
WLSD-TH WLSD-TH-N WLMGCA2-LDK43 WLMGCA2-LDK43-N
WLSD-TC WLSD-TC-N WLMGCA2-LD-M1J WLMGCA2-LD-M1J-N
WLSD-RP WLSD-RP-N WLMH2-LD WLMCA2-LD-N
WLSD2-55 WLSD2-55-N WLMH2-LDK13A WLMCA2-LDK13A-N
WLSD2-55LD WLSD2-55LD-N WLMH2-LDK13 WLMCA2-LDK13-N
WLSD2-139 WLSD2-139-N WLMH2-LDK43A WLMCA2-LDK43A-N
WLSD2-140 WLSD2-140-N WLMH2-LDK43 WLMCA2-LDK43-N
WLSD2-RP60 WLSD2-RP60-N WLMH2-LD-M1J WLMCA2-LD-M1J-N
WLSD2-TH WLSD2-TH-N WLMH2-LD-DGJ03 WLMCA2-LD-DGJ-N
WLSD2-TC WLSD2-TC-N WLMG2-LD WLMG2-LD-N
WLSD2-RP WLSD2-RP-N WLMG2-LDK13A WLMG2-LDK13A-N
WLNJ-55 WLNJ-55-N WLMG2-LDK13 WLMG2-LDK13-N
WLNJ-55LD WLNJ-55LD-N WLMG2-LDK43A Ask your OMRON representative.
WLNJ-139 WLNJ-139-N WLMG2-LDK43 WLMG2-LDK43-N
WLNJ-140 WLNJ-140-N WLMG2-LD-M1J WLMG2-LD-M1J-N
WLNJ-RP60 WLNJ-RP60-N WLMG2-LD-DGJ03 WLMG2-LD-DGJ-N
WLNJ-TH WLNJ-TH-N WLRCA2 WLRCA2-N
WLNJ-TC WLNJ-TC-N WLRGCA2 WLRGCA2-N
WLNJ-RP WLNJ-RP-N WLRG2 WLRG2-N
WLNJ-255 WLNJ-255-N WLRH2 WLRCA2-N
WLNJ-255LD WLNJ-255LD-N WLRCA2-2 WLRCA2-2-N
WLNJ-2140 WLNJ-2140-N WLRCA2-2N WLRCA2-2N-N
WLNJ-2RP60 WLNJ-2RP60-N WLRCA2 WLRCA2-N
WLNJ-2TC Ask your OMRON representative. WLRG2 WLRG2-N
WLNJ-2RP WLNJ-2RP-N WLRH2 WLRCA2-N
WLCA2-LEAS WLCA2-LEAS-N WLRCA2-2 WLRCA2-2-N
WLH2-LEAS WLCA2-LEAS-N WLRCA2-2N WLRCA2-2N-N

43
WL-N/WLM-N
Safety Precautions
Precautions for Safe Use Precautions for Correct Use
• Be sure to ground. If not, there is the possibility that electrical shock Environment
occurs. • Take special care to use where there is fine powder, mud and/or
• Do not touch charged switch terminals while the switch has carry foreign materials stacking. And check the condition with actual
current, otherwise there is the possibility that electrical shock using condition before using. Then use without a performance
occurs. problem.
• Do not disassemble the limit switch or touch inside of it under • This switch is only for indoor use. If it is used in outdoor, it may be
supplying power, otherwise there is the possibility that electrical cause of switch failure.
shock occurs. • Do not keep the Switch in locations with corrosive gas, such as
• Do not touch the wire or rod type actuator in order to prevent injury. sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
• Connect a fuse which has 1.5 to 2 times higher breaking current or chlorine gas (Cl2), or high temperature and humidity. Otherwise,
than the switch rated current to the switch in series in order to contact failure or corrosion damage may result.
prevent the switch from short-circuit damage. • Seal material may deteriorate if a Switch is used outdoor or where
On the occasion when using the switch with GB ratings, use a 10A subject to special cutting oils, solvents, or chemicals. Always
fuse that complies IEC60269, either type gG. appraise performance under actual application conditions and set
• The durability of switch is depends on the operating condition. suitable maintenance and replacement periods.
Be sure to check the condition with actual using condition before • Install Switches where they will not be directly subject to cutting
using, and use with the number of times of operating without a chips, dust, or dirt. The Actuator and Switch must also be protected
performance problem. from the accumulation of cutting chips or sludge.
• Do not drop the switch. Otherwise, there is the possibility that the
switch functions may be spoiled. Not Suitable Suitable
• Do not connect a Single Limit Switch to two power supplies that are
different in polarity or type.
• Be sure to keep the load current less than the rated value.
Otherwise, there is the possibility that the switch may be damage
and/or burnout.
• Minimum operating load: 5 VDC 1 mA, resistive load, P level
Note: The P level indicates the standard malfunction level at a • Constantly subjecting a Switch to vibration or shock can result in
reliability level of 60% (λ60). wear, which can lead to contact interference with contacts,
(JISC5003) λ60 = 0.1 × 10-6 per operation, which indicates an operation failure, reduced durability, and other problems.
estimated malfunction of 1 out of every 10,000,000 operations Excessive vibration or shock can lead to false contact operation or
at a reliability level of 60%. damage. Install Switches in locations not subject to shock and
• Do not use the Switch by itself in atmospheres containing vibration and in orientations that will not produce resonance.
flammable or explosive gases. Arcs and heating resulting from • The Switches have physical contacts. Using them in environments
switching may cause fire or explosion. containing silicon gas will result in the formation of silicon oxide
• Be sure to prevent the foreign materials such like a scrapped cable (SiO2) due to arc energy. If silicon oxide accumulates on the
intrusion in to the switch when wiring. Otherwise, there is the contacts, contact interference can occur. If silicon oil, silicon filling
possibility of spoiling the normal operation. agents, silicon cables, or other silicon products are present near
• Never wire to the wrong terminals. the Switch, suppress arcing with contact protective circuits (surge
• Do not store or use the switch with following place. killers) or remove the source of silicon gas.
Where the temperature fluctuates greatly
Where the humidity is very high and condensation may occur. Installing the Switch
Where the vibration is too much • To install the Switch, make a mounting panel, as shown in the
Where receiving direct sunshine. following diagram, and tighten screws using the correct torque.
Where receiving salty wind.
• Do not disassemble and/or modify the switch at anytime. Front Mountig : Four, 5.2 +0.2
0 dia. holes
Otherwise, there is the possibility of spoiling the normal operation. or M5 tapped holes
58.7±0.15
• Do not apply the force such like deformation and/or degeneration Rear Mountig : Four, 6.2 +0.2
0 dia. holes

to the switch. Otherwise, there is the possibility that the switch


functions may be spoiled.
30.2 ±0.15

44
WL-N/WLM-N

Tightening Torque Overtravel Markers


• All Switches with Roller Lever Actuators except for Switches with
• If screws are too loose they can lead
Fork Lever Locks and Low-temperature Switches have a set
to an early malfunction of the Switch, (1)
position marker plate.
so ensure that all screws are
• To allow the roller lever type actuator to travel properly, set the
tightened using the correct torque.
roller lever according to the dog or cam stroke so that the
• In particular, when changing the (3)
arrowhead of the lever is positioned within overtravel markers as
direction of the Head, make sure that (6) shown.
all screws are tightened again to the
correct torque. Do not allow foreign Head Screw down
objects to fall into the Switch. (4)
Arrowhead

(2)
Excessive OT
Setting range
(5) Shortage OT
Setting range
No. Type Torque Screw type Excessive OT

0.78 to 0.88
(1) Head mounting screw M3.5 screw
N•m Connectors
1.18 to 1.37 • Tighten the connector with the appropriate torque to prevent
(2) Cover mounting screw M4 screw
N•m deformation.
(3)
Allen-head bolt 4.90 to 5.88 M5 hexagon socket • Use the OMRON type SC connector series, which is prepared
(for securing the roller lever) N•m head cap screw separately, suitable for outer diameter of cable and inner diameter
Allen-head bolt of seal rubber.
0.88 to 1.08 M8 hexagon socket set
(3) (for securing the adjustable • Make sure to wrap the connector with the seal tape, except the
N•m screw
rod lever)
connector which has O-ring, to keep the sealability.
0.59 to 0.78
(4) Terminal screw M3.5 screw • To conform to CSA, use a CSA certified water tight treated conduit
N•m
hub.
1.77 to 2.16 G1/2orPg13.5orM20or
(5) Connector • Even when the connector is assembled and set correctly, the end
N•m 1/2-14NPT
of the cable and the inside of the Switch may come in contact. This
4.90 to 5.88 M5 hexagon socket
(6) Unit mounting screw
N•m head cap screw
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
Wring
In the case of mounting screw Microload Applications
• Use M3.5-nylon insulation covered crimp terminals (round type) for • The switch contacts can be used both for standard loads and
wiring. microloads, but once a contact has been used to open and close a
Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.) load it can no longer be used for lower loads. Doing so will damage
• Appropriate wire size is AWG16 (1.25mm2). the contact surface and reduce contact reliability.
• Do not supply electric power when wiring. • If an inrush current or other sudden load occurs during a switch
Otherwise electric shock may result. operation, the switch will begin to degrade severely which can
• Do not pull out the wires with excessive force. result in reduced durability.
It may cause of coming off the wire. Use a contact protection circuit if required.
• Use crimp terminals for wiring.
Indicator
• In the case of lump unit, to avoid interference
Indicator-equipped switch has contacts and indicator in parallel.
between lump unit and crimp terminals, wire
When contacts are open, leakage current flows through the indicator
according to right wiring figure.
circuit and may cause load's malfunction.
Attach the lump unit spring to terminal screw
Please check the load's OFF current before use the indicatorequipped
certainly otherwise itÅfs possible to be destroyed
switch. Leakage current may cause load malfunction (i.e., the load
or shorted.
may remain ON). Make sure that the load operating current is higher
• The ground terminal is only installed on models
than the leakage current.
with ground terminals.
For countermeasures, refer to technical support on your OMRON
website.
In the case of prewired connecter and direct connecter
• Holding the connecter certainly when pulling connecter. Terminal Plate
• Don’t pull the cable holding it. • By using the Terminal Plate (sold separately), as shown in the
following diagram, the Switch can be used as a single-polarity
double-break switch.
How to handle
Changing direction of the head Attach the Terminal Plate
so that the “COM” mark is
• By removing the screws in the two corners of the head, the head oriented as shown on the left.
can be set any of four directions. Be sure to change the plunger for
internal operations at the same time.

Built-in Switch
• Do not remove or replace the built-in switch.
Terminal Plate
Terminal Plate Mounting Diagram
Model WL-N TERMINAL PLATE (with Two Terminal Screws Removed)

45
WL-N/WLM-N

Using a WL@-2N Switch Mounted from the Side • With a roller actuator, the dog must touch the actuator at a right
If you replace a previous Switch with a WL@-2N-N Switch, a Mounting angle. The actuator or shaft may deform or break if the dog touches
Plate (sold separately) is available to maintain mounting compatibility. the actuator (roller) at an oblique angle.
If you use the Mounting Plate, the Switch mounting holes and actuator Incorrect Correct
position will be compatible. (The position of the dog will not need to
be changed.) Dog
Dog
Mounting Plate

• Make sure that the actuator does not exceed the OT (overtravel)
range, otherwise the Limit Switch may malfunction. When mounting
Plate mounting the Limit Switch, be sure to adjust the Limit Switch carefully while
Set bolts (2) considering the whole movement of the actuator.
58.7
64

contents
Operating
body PT (Pretravel)
23 30.2 Switch mounting
Install a stopper.
WL@-2N Replacing a Switch Plate (1) bolts (2)
Mounting Plate with the WL@-2N-N Model WLN-P001 FP (Free position)
OP (Operating position)
70% of
100% of
rated OT OT (Overtravel)
rated OT
Operation
TTP (Total travel position)
• Carefully determine the position and shape of the dog or cam so that Optimum setting range
the actuator will not abruptly snap back, thus causing shock. In order Distance to the
to operate the Limit Switch at a comparatively high speed, use a dog optimum setting range.
or cam that keeps the Limit Switch turned ON for a sufficient time so
that the relay or valve will be sufficiently energized. Reference line
• The method of operation, the shape of the cam or dog, the
operating frequency, and the travel after operation have a large
influence on the durability and operating accuracy of the Limit • The Limit Switch may soon malfunction if the OT is excessive.
Switch. The cam or dog must be smooth in shape. Therefore, adjustments and careful consideration of the position of
the Limit Switch and the expected OT of the operating body are
Incorrect Correct necessary when mounting the Limit Switch.
Correct

Snapped
back
Abruptly Stopper
actuated

• When using a pin-plunger actuator, make sure that the stroke of the
Incorrect Correct actuator and the movement of the dog are located along a single
straight line.

Snapped Incorrect Correct


back Abruptly
actuated

Operating Operating
body body
• Appropriate force must be imposed on the actuator by the cam or
dog in both rotary operation and linear operation.
If the dog touches the lever as shown below, the operating position
will not be stable.
Incorrect Correct

Dog Dog

Others
• For long term (over a year) storage, check according to Operating
characteristics, Contact resistance and Dielectric strength at least.
And check with using condition.
• Unbalanced force must not be imposed on the actuator. Otherwise, • The durability of the Switch is greatly affected by operating
wear and tear on the actuator may result. conditions.
Evaluate the Switch under actual working conditions before
Incorrect Correct
permanent installation and use the Switch within a number of
switching operations that will not adversely affect the SwitchÅfs
performance.

Dog Dog

Roller Roller

46
WL-N/WLM-N

Using the Switches


Item Applicable models and Actuators Details
Changing the Installation Position
of the Actuator
Roller Levers:
By loosening the Allen-head bolt on
(WLCA2-N, WLCA2-2-N,
the actuator lever, the position of the
WLCA2-2N-N, WLG2-N,
actuator can be set anywhere within
WLCA2-7-N, WLCA2-8-N,
the 360°.
WLGCA2-N, WLMCA2-N,
With Indicator-equipped Switches, the
WLMG2-N, WLMGCA2-N) Loosen the Allen-head bolt, set
actuator lever comes in contact with the actuator's position and then
Adjustable Roller Levers:
the top of the indicator cover, so use tighten the bolt again.
(WLCA12-N, WLCA12-2-N,
caution when rotating and setting the
WLCA12-2N-N, WLG12-N)
lever.
Adjustable rod lever:
When the lever only moves forwards
(WLCL-N, WLCL-2-N,
and backwards, it will not contact the
WLCL-2N-N, WLGL-N,
lamp cover.
WLCAL4-N, WLCAL5-N)
(This does not apply to Long-life
Switches.)
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N, WLMCA2-N,
Head Loosen the screws.
Changing the Orientation of the WLMG2-N, WLMGCA2-N)
Head Adjustable Roller Levers:
By removing the two screws of the (WLCA12-N, WLCA12-2-N,
Head, the Head can be set in any of WLCA12-2N-N, WLG12-N)
the four directions. Adjustable rod lever:
Be sure to change the plunger for (WLCL-N, WLCL-2-N,
internal operations at the same time. WLCL-2N-N, WLGL-N,
The roller plunger can be set in either WLCAL4-N, WLCAL5-N)
of two positions at 90° Horizontal plunger
(WLSD@-N)
Sealed top-roller plunger
(WLD28-N)
Note: Does not include the -RP60
Series or -141 Series.
p
The output of the Switch will be The output of the Switch will
Roller Levers: changed, regardless of which only be changed when the lever
(WLCA2-N, WLCA2-2-N, direction the lever is pushed. is pushed in one direction.
WLCA2-2N-N, WLG2-N, Operating Operating Not operating Operating Operating Not operating
WLCA2-7-N, WLCA2-8-N,
Changing the Operating Direction
WLGCA2-N, WLMCA2-N,
By removing the Head on models
WLMG2-N, WLMGCA2-N)
which can operate on one-side only,
Adjustable Roller Levers:
and then changing the direction of the
(WLCA12-N, WLCA12-2-N,
operational plunger, one of three
WLCA12-2N-N, WLG12-N)
operating directions can be selected.
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N,
WLCAL4-N, WLCAL5-N)
Operation in both Clockwise operation Counterclockwise
directions operation

Roller Levers:
(WLCA2-N, WLCA2-2-N,
Installing the Roller on the Inside WLCA2-2N-N, WLG2-N,
By installing the roller lever in the WLCA2-7-N, WLCA2-8-N,
opposite direction, the roller can be WLGCA2-N, WLMCA2-N,
installed on the inside. WLMG2-N, WLMGCA2-N)
(Set so that operation can be Fork lever lock: Loosen the
completed within a 180° level range.) (WLCA32-4@-N) Allen-head bolt.
Note: Except for Switches with
variable roller levers.

47
WL-N/WLM-N

Item Applicable models and Actuators Details

Loosen this
Adjustment Allen-head bolt
range radius:
24 to 140 mm and adjust the
Loosen this length of the rod.
Adjustment
Allen-head bolt range radius:
Adjustable Roller Levers: and adjust the 25 to 89 mm
Adjusting the Length of the Rod or
(WLCA12-N, WLCA12-2-N, length of the
Lever lever.
WLCA12-2N-N, WLG12-N)
The length of the rod or lever can be
Adjustable rod lever:
adjusted by loosening the Allen-head
(WLCL-N, WLCL-2-N,
bolt.
WLCL-2N-N, WLGL-N, WLCAL4-N)

Adjustable Roller Levers: Adjustable Rod Levers:

WLCA32-41-N WLCA32-43-N

Selecting the Roller Position


There are four types of Switches with Fork lever lock:
WLCA32-42-N WLCA32-44-N
Fork Lever Locks for use depending on (WLCA32-4@-N)
the roller position.

An explanation of the operation of fork lever locks is provided after this


table.

Operation of Fork Lever Locks


A Switch with a Fork Lever Lock is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after
the dog moves on.
If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Example

NC terminal: ON NO terminal: ON NO terminal: ON

48
WL-N/WLM-N
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
Inner diameter (D) External diameter of cable
Conduit Applicable cable Model Applicable model
of seal rubber Min. Max.
7 mm 5.5 mm 7.5 mm SC-1M
9 mm 7.5 mm 9.5 mm SC-2M
Cabtire cable (general-
12.5 mm 11 mm 13 mm SC-3M
purpose)
14 mm 12 mm 14 mm SC-4M
11 mm 9 mm 11 mm SC-5M WL-N, D4A-@N, D4B-@N, ZE,
JIS B 0202 G½
7 mm 5.5 mm 7.5 mm SC-21 ZV, ZV2, XE, XV, XV2
9 mm 7.5 mm 9.5 mm SC-22
Cabtire cable (anti-
12.5 mm 11 mm 13 mm SC-23
corrosive)
14 mm 12 mm 14 mm SC-24
11 mm 9 mm 11 mm SC-25
7 mm 5.5 mm 7.5 mm SC-1PT
9 mm 7.5 mm 9.5 mm SC-2PT
½-14NPT Cabtire cable 12.5 mm 11 mm 13 mm SC-3PT D4A-@N
14 mm 12 mm 14 mm SC-4PT
11 mm 9 mm 11 mm SC-5PT
Note: Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not necessary to
ensure a proper seal.

Simple Connectors (Not Suitable for Locations Subject to Oil or Water)


Inner diameter (D) External diameter of cable
Conduit Applicable cable Model Applicable model
of seal rubber Min. Max.
WL-N, D4A-@N, D4B-@N, ZE,
JIS B 0202 G½ 10.6 mm 8.5 mm 10.5 mm SC-P2
ZV, ZV2, XE, XV, XV2
Pg13.5 9.6 mm 7.5 mm 9.5 mm SC-P3 WL@-G-N
Cabtire cable
WL-N, D4A-@N, D4N *,
JIS B 0202 G½ 9 mm 7.5 mm 9 mm SC-6 D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2
Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.

49
WL-N/WLM-N

Dimensions and Structure (Unit: mm)


Connectors for Cabtire Cable
As for models without an O-ring, please use sealing tape with SC Connectors.

Metal Models without O-ring JIS B 0202 G½


Ball head lock nut
14.6 dia. 24 (brass and nickel plating) Sealing rubber
G½ *E 15
4.8
9 14 dia. (nitrile rubber)
Washer (stainless steel)
SC-21 to 25 Connector
(brass and nickel plating)

29.3 27.7 *D

(34)

Ball head lock nut


Metal Models with O-ring (zinc die-cast and zinc plating) Sealing rubber
14.6 dia. JIS B 0202 G½ 27 (nitrile rubber)
G½ *E 15 5 9 14 dia.
Washer (stainless steel)
Connector
SC-1M to 5M (zinc die-cast and
zinc plating)
*D
29.3 30

Sealing rubber (nitrile rubber)


(34)

Metal Models without O-ring Ball head lock nut


(zinc die-cast and zinc plating)
½-14NPT 14.6 dia. 5
½-14NPT
24
Sealing rubber (nitrile rubber)
14 dia. 15 14 14 dia. Washer (stainless steel)
(U.S.-standard screws) Connector
(zinc die-cast and
SC-1PT to 5PT zinc plating)
29.3 27.7 *D

(39)

Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.

Simple Connectors (Not Suitable for Locations Subject to Oil or Water)


Resin Models JIS B 0202 Hexagonal nut
Conduit washer
(ferrous metal and
15 1 4.5
G½ 22 5
G½ (polyacetal resin) zinc plating)
Ring (chloroprene rubber)
SC-P2
25.4 18 dia. 18 dia.
12.6 dia. 10.6 dia.

Resin Models Conduit washer


(ferrous metal and
Hexagonal nut
Pg13.5 15.5 Pg13.5 1 4.5 (polyacetal resin) zinc plating)
21 5 Ring (chloroprene rubber)
SC-P3

23.5 18 dia. 18 dia.


12 dia. 9.6 dia.

Resin Models (30.6) 22.5


Ball head lock nut
(polyacetal resin) Sealing rubber (nitrile rubber)
10 12 12
G½ 9 5 9 9
Washer Connector
(ferrous metal and (polyacetal resin)
SC-6 zinc plating)

26 *D

G½ M20 × 1.5

Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
* Diameter of Part Marked with Asterisk
Inner diameter (D) Internal diameter
Model Applicable cable
of sealed rubber (E) of washer
SC-21, -1M, -1PT 7 mm 10.4 mm 5.5 to 7.5-mm dia.
SC-22, -2M, -2PT 9 mm 13.2 mm 7.5 to 9.5-mm dia.
SC-23, -3M, -3PT 12.5 mm 14.6 mm 11 to 13-mm dia.
SC-24, -4M, 4PT 14 mm 14.6 mm 12 to 14-mm dia.
SC-25, -5M, -5PT 11 mm 13.2 mm 9 to 11-mm dia.
SC-6 9 mm 10 mm 7.5 to 9-mm dia.

50
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation Industrial Automation Company Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V. OMRON ELECTRONICS LLC
Wegalaan 67-69, 2132 JD Hoofddorp 2895 Greenspoint Parkway, Suite 200
The Netherlands Hoffman Estates, IL 60169 U.S.A
Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. © OMRON Corporation 2013-2014 All Rights Reserved.
No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, In the interest of product improvement,
Alexandra Technopark, 200 Yin Cheng Zhong Road, specifications are subject to change without notice.
Singapore 119967 PuDong New Area, Shanghai, 200120, China CSM_2_1_0714 Printed in Japan
Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Cat. No. C147-E1-02 0714 (1013)