0% found this document useful (0 votes)
438 views2 pages

CAMEL Call With Initial IDP Successful (Short Number Call 2)

1) A call is made from Number A (CC618953685) to Number B (69266). 2) A Connect to CAMEL ROUTING Number is used to send an Initial Address Message (IAM) with the routing number 69962. 3) The result of the trace is successful, indicating a connection was made to the CAMEL network.

Uploaded by

surya5458
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
438 views2 pages

CAMEL Call With Initial IDP Successful (Short Number Call 2)

1) A call is made from Number A (CC618953685) to Number B (69266). 2) A Connect to CAMEL ROUTING Number is used to send an Initial Address Message (IAM) with the routing number 69962. 3) The result of the trace is successful, indicating a connection was made to the CAMEL network.

Uploaded by

surya5458
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

CAMEL

NumberA: CC618953685 calls NumberB: 69266

Result of this traces is successful: there is a Connect to CAMEL


ROUTING Number used to send an IAM.

Initial IDP
Message #1

TCAP/CAP Phase 3
------------------------------------------------------
Begin = begin (Begin)
begin
otid = 1209467251
dialoguePortion
type-id = { 0 0 17 773 1 1 1 }
0 = itu-t
0 = recommendation
17 = q
773 = 773
1 = as
1 = dialogue-as
1 = version1
value
DialoguePDUs.DialoguePDU = dialogueRequest
dialogueRequest
protocol-version = {version1}
application-context-name = { 0 4 0 0 1 0 50 0 } (cap-gsmssf-to-gsmscf version 1) CAMEL phase used
0 = itu-t
4 = identified-organization
0 = etsi
0 = mobileDomain
1 = umts-network
0 = ac-Id
50
0
components
components nr 0 = basicROS
basicROS = invoke
invoke
invokeId = present
present = 0
opcode = local
OP Code = 0 (initialDP)
argument
SEQUENCE
serviceKey = 67
callingPartyNumber
-0000100 Nature of address indicator = 4 (international number)
1------- Odd/even indicator = 1 (odd number of address signals)
------11 Screening indicator = 3 (network provided)
----00-- Address presentation restricted indicator = 0 (presentation allowed)
-001---- Numbering plan indicator = 1 (ISDN (Telephony) numbering plan (Recommendation E.164))
0------- Number Incomplete indicator (NI) = 0 (complete)
Address signals = CC618953685 Number A
0000---- Filler = 0
callingPartysCategory
00001010 Calling party's category = 10 (ordinary calling subscriber)
locationNumber
-0000011 Nature of address indicator = 3 (national (significant) number (national use))
0------- Odd/even indicator = 0 (even number of address signals)
------11 Screening indicator = 3 (network provided)
----01-- Address presentation restricted indicator = 1 (presentation restricted)
-001---- Numbering plan indicator = 1 (ISDN (telephony) numbering plan (Recommendation E.164))
1------- Internal Network Number indicator (INN) = 1 (routing to internal number not allowed)
Address signals = 05113237480832
highLayerCompatibility = 37249
bearerCapability = bearerCap
bearerCap
---00000 Information transfer capability = 0 (Speech)
-00----- Coding standard = 0 (ITU-T standardized coding as described below)
1------- 0/1 ext = 1 (StopBit)
---10000 Information transfer rate = 16 (64 kbit/s)
-00----- Transfer mode = 0 (Circuit mode)
1------- 0/1 ext = 1 (StopBit)
---00011 User information layer 1 protoco = 3 (Recommendation G.711 A-law)
-01----- Layer 1 identity = 1
1------- 0/1 ext = 1 (StopBit)
eventTypeBCSM = 2 (collectedInfo)
IMSI = IMSI(MCC+MNC) 2130001802
locationInformation
ageOfLocationInformation = 0
vlr-number
----0001 numbering plan indicator = 1 (ISDN/Telephony Numbering Plan (Rec ITU-T E.164))
-001---- nature of address indicator = 1 (international number)
1------- Extension Bit = 1 (no extension)
Address signals = 491760000086
cellIdOrLAI = cellIdFixedLength
cellIdFixedLength
Mobile Country Code (MCC) = 262
Mobile Network Code (MNC) = 03
Location Area Code (LAC) = 51051
CellIdentity = 51961
ext-basicServiceCode = ext-Teleservice
ext-Teleservice = 17 (Telephony)
callReferenceNumber = 18047865081186551
mscAddress
----0001 numbering plan indicator = 1 (ISDN/Telephony Numbering Plan (Rec ITU-T E.164))
-001---- nature of address indicator = 1 (international number)
1------- Extension Bit = 1 (no extension)
Address signals = 491760000086
calledPartyBCDNumber
----0001 numbering plan indicator = 1 (ISDN/Telephony Numbering Plan (Rec ITU-T E.164))
-000---- nature of address indicator = 0 (unknown)
1------- Extension Bit = 1 (no extension)
Address signals = 69266f Number B dialed

Message #2
------------------------------------------------------

TCAP/CAP Phase 3
------------------------------------------------------
Continue = continue (Continue)
continue
otid = 801120596
dtid = 1209467251
dialoguePortion
type-id = { 0 0 17 773 1 1 1 }
0 = itu-t
0 = recommendation
17 = q
773 = 773
1 = as
1 = dialogue-as
1 = version1
value
DialoguePDUs.DialoguePDU = dialogueResponse
dialogueResponse
protocol-version = {version1}
application-context-name = { 0 4 0 0 1 0 50 0 } (cap-gsmssf-to-gsmscf version 1) CAMEL phase used
0 = itu-t
4 = identified-organization
0 = etsi
0 = mobileDomain
1 = umts-network
0 = ac-Id
50
0
result = 0 (accepted)
result-source-diagnostic = dialogue-service-user
dialogue-service-user = 1 (no-reason-given)
components
components nr 0 = basicROS
basicROS = invoke
invoke
invokeId = present
present = 1
opcode = local
OP Code = 20 (connect)
argument
SEQUENCE
destinationRoutingAddress
destinationRoutingAddress nr 0
-0000100 Nature of address indicator = 4 (international number)
1------- Odd/even indicator = 1 (odd number of address signals)
----0000 Spare = 0 (Spare field (4 bits))
-001---- Numbering plan indicator = 1 (ISDN (Telephony) numbering plan (Recommendation E.164))
0------- Internal Network Number indicator (INN ind.) = 0 (routing to internal network number allowed)
Address signals = CAMELROUTINGNUMBER 69962 This is the CAMEL ROUTING NUMBER asigned to send an IAM
0000---- Filler = 0