0% found this document useful (0 votes)
120 views4 pages

Slim Transformer

The document discusses SLIMa transformers produced by The Saudi Transformers Co. Ltd. SLIMa transformers use Nomex insulation and high temperature fluids, allowing them to operate at higher temperatures while maintaining a compact design. This improves efficiency and reliability compared to conventional transformers. For the same rating, SLIMa transformers can be up to 25% smaller and lighter. They also have a 50% higher kVA rating potential and offer lower losses, higher efficiency, and improved fire resistance.

Uploaded by

Jamal Habbas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views4 pages

Slim Transformer

The document discusses SLIMa transformers produced by The Saudi Transformers Co. Ltd. SLIMa transformers use Nomex insulation and high temperature fluids, allowing them to operate at higher temperatures while maintaining a compact design. This improves efficiency and reliability compared to conventional transformers. For the same rating, SLIMa transformers can be up to 25% smaller and lighter. They also have a 50% higher kVA rating potential and offer lower losses, higher efficiency, and improved fire resistance.

Uploaded by

Jamal Habbas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

THE SAUDI TRANSFORMERS CO.LTD.

An F1 Company
THE SAUDI TRANSFORMERS CO.LTD.

Introduction Also the increases in average oil tempera-


tures will be minimal.
STC's SLIMa Transformers use DuPont
Nomexe high temperature insulation and Conversely, for a given size and weight, the
high temperature fluids (Silicone, Biotemp kVA rating can be increased up to 50
or ester fluids) They have higher percent. It is important to note that use of
mechanical and dielectric strength due to high temperature like silicone Biotemp or
the presence of Nomexa insulation and can ester fluids permits even greater savings in
also be operated at higher temperatures. size and weight.

These transformers have a very compact


design. They are specially made to answer Increased Capacity at peak loads
the requirements of transformers where SLIM" transformers insulated with NomexB
installation space and safety factor are of can be designed for extra power capacity in
prime concern without compromising emergency peak load situations.
efficiency, reliability and safety.

Nomexethermal Insulation Improved reliability


Nomexe thermal insulation technology has Insulation systems based on Nomex"
been developed by DuPont, a well technologies maintain excellent electrical
renowned company in the field of chemical and mechanical characteristics over a
products. NomexB paper and pressboards transformer's service life. Negligible aging,
are made entirely of synthetic aromatic resistance to shrinkage and compression,
polyamide polymer that offer high levels of and the superior resilience of Nomexa help
electrical, chemical and mechanical coil structures remain firm and withstand
integrity. short-circuit forces, even after years of
service.

Advantages of It is possible to offer lower losses


SLIM@transformer compared with conventional insulation by
using NomexB. Consequently, the lower
Reduced size and weight - losses result in higher efficiency.

For a given kVA output, the weight of a Use of Silicone, Biotemp or ester fluids as
transformer can be reduced up to 25 dielectric mediums provides excellent fire
percent whereas top oil temperature can be resistance thereby decreasing costs
maintained at constant levels. pertaining to fire fighting. Moreover, it is
environment friendly compared to
conventional oil.

registered
SLIM"Transformers up to 5000 kVA

I
Comparison between typical rating of Slim"
& Conventional Transformers
SLIMBTransformer :onventional Transformer ~IUI
hni-.-

Power Rating 1500 kVA


HV Rating 13800 V
-
-
- -
- -
- - .
-
- ..
- -
-

LV Rating 23T V
'
. .- -

L
1
No load Losses 1400 Watts 1700 Watts

I Width 4 I

Standard Ratings
I Rating HV
I
-
LV
- - -
I Frequency
-- - --
BIL
-
I

*Detailed design can be provided on request depending on the requirements.

About Us:
Saudi Transformers Co. Ltd. is one of the leading manufacturer of three-phase transformers
in the Middle East, offering a full-range of products such as Pole Mounted Transformers, Pad
Mounted Distribution 1 Power Transformers, Package and Unit Substations, LV Panels and
SLIM@Transformers. STC wasestablished under license from CG Belgium (Formerly known
as Pauwels Belgium).

The Saudi Transformers Co. has the capacity to manufacture transformers up to 5000 kVA
with HV rating up to 36 kV and BIL up to 200 kV. It is located in the First Industrial Crty in
Dammam, Saudi Arabia, a strategic location for neighboring countries like Kuwait, Iraq,
Bahrain, Qatar, and UAE.

For further information, please contact:


Mr. Hosam Abdel Haleem Al Sheikh Mr. Ahmad Nadeem Khawaja
Vice President Transformers Sales Manager
The Saudi Transformers Co. Ltd., KSA The Saudi Transformers Co. Ltd., KSA
Tel.: +966 3 8100 280 ext. 1500 Tel.: +966 3 8473 020 ext. 222
Email: [email protected] Email: [email protected]
THE SAUDI TRANSFORMERS CO.LTD.
An
-I
F Company
a@umClrlkd
EkaricalIndustries

Head Office & Factory I Riyadh Office


1st Industrial City P.O.Box 968, Riyadh 11421
P.O.Box 5785, Darnrnam 31432 Tel.: +966 1 403 9624, Fax: +966 1 402 3130
Tel.: +966 3 847 3020. Fax: +966 3 847 1718 !
Ernail: [email protected] i Jeddah Office
P.O. Box 34673, Jeddah 21478
Website: www.sauditransforrners.com ! Tel.: +966 2 651 2394, Fax: +966 2 651 2664