This document calculates the heat required to raise the temperature of a swimming pool. It provides the formulas to calculate the heat required to raise the temperature (heat-up) and the heat lost through the surface. It determines that the heat-up required is 223,983.72 BTU/hr or 65.585 KW and the heat lost through the surface is 23,508.24 BTU/hr or 6.883 KW, for a total heat required of 247,492 BTU/hr or 72 KW. It also provides quick facts about safe water temperatures for hot tubs.

Uploaded by

luai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
521 views1 page

Heat Calculation For Swimming Pool

This document calculates the heat required to raise the temperature of a swimming pool. It provides the formulas to calculate the heat required to raise the temperature (heat-up) and the heat lost through the surface. It determines that the heat-up required is 223,983.72 BTU/hr or 65.585 KW and the heat lost through the surface is 23,508.24 BTU/hr or 6.883 KW, for a total heat required of 247,492 BTU/hr or 72 KW. It also provides quick facts about safe water temperatures for hot tubs.

Uploaded by

luai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Lebanon Villa @28 C

Heat Calculation for swimming pool

h total  = h surface  + h heat-up  (btu/hr) KW % KW

23,508.24 223,983.72 247,492 72 1.25 91


62,311 77,889 (kcal/hr)
o
h heat-up  = V 8.34 (lbs/gal) dT w  1.0 (Btu/lb  F) / dt 

3
V = l w d 7.5 (gal/ft )

V = volume (Gal) 8,263.56 (gal)


A (ft2) 258.33 (ft2)
l = length (ft) 6 m 19.68 (ft)
w = width (ft) 4 m 13.12 (ft)
d = depth (ft) 1.3 m 4.27 (ft)

dTdTw = difference between initial temperature and the final temperature of the water(oF)

dt = heat pick-up time (hr)


dTdTw 13 o
( F)
dt 4 hr

h heat-up   = 223,983.72  (btu/hr) 65.585 KW

Note: That this value is without the increased heat loss through the surface due to increased
temeperature difference and increased evaporation when the temperature increase.

h surface  = k s  dT aw  A  

k s  = surface heat loss factor - for sheltered positions with average wind velocity 2 to 5 (mph),
2 o
the surface heat loss factor is in the range 4 to 7 (Btu/hr ft   F)
o
dT aw  = temperature difference between the air and surface water in the pool ( F)
2
A = surface area of the pool (ft )

ks  7 (Btu/hr ft   F)
2 o

dT aw   13 o
( F)
A 258.33 2
(ft )

h surface  = 23,508.24  (btu/hr) 6.883 KW

WATER TEMPERATURE QUICK FACTS


• The majority of hot tub users prefer a water temperature in the range of 100°F-102°F.
• 104°F is the standard maximum temperature, which some users also prefer.
• Always consult a physician before getting in the hot tub while pregnant.
• Children under age 5 should not be in hot tubs over 95°F, and should only remain in hot tubs for 5-10
minutes at a time.