2000
Overview Introduction
3000
Piston
3000
Piston Accumulators
4000
5000
Threaded Piston Accumulators ■ ACP Crimped Piston ■ Gas Bottles
■ Metric Accumulators & Bottles
IN THIS SECTION
Series 2000 & 3000 29
ACP Piston Accumulators 37
Series 4000 & 5000 43
Features:
• Heavy Duty Service with
Operating Pressures to 5000 PSI
• 1.5" thru 12" Bores with Over
Fifty Standard Capacities
• “Fatigue Tested” Designs,
2" thru 7" Bores
• V-O-ring Piston Seals Std
• Serviceable Threaded End
Construction
• Certifications Available: ASME,
DNV, ABS, AS1210, SELO, CRN,
GOST, CE
• Five Standard Seal Options to
Handle a Variety of Fluids and
Temperatures
• Temperature Ranges
-45° to 320°F
Parker Hannifin
Global Accumulator Division
25 United States
Catalog HY10-1630/US Piston Accumulators
Overview Introduction
Parker Hannifin
Global Accumulator Division
26 United States
Catalog HY10-1630/US Piston Accumulators
2000
Design Features & Benefits Introduction
3000
1 Piston type accumulators are designed with compact, rugged steel shell
and caps. The steel shell allows heat to dissipate effectively. The bore is
micro-finished for extended seal life. The threaded caps allow for easy
Piston
3000
repair and seal replacement.
2 The piston seal consists of a unique, five-bladed
V-O-ring with back-up washers. This design eliminates
4000
seal roll-over and ensures total separation of fluid and
gas under the most severe operating conditions.
The V-O-ring also holds full pressure throughout long idle periods
5000
between cycles, providing dependable, full pressure storage of hydraulic
energy. It ensures safe, reliable absorption of pressure peaks. The piston
seal design helps to prevent sudden failure of the accumulator.
The V-O-ring seals are available in a wide variety of compounds to cover
a broad range of fluids and operating temperature ranges (see Options).
7 1 3 2 4 5
6
Parker Hannifin
Global Accumulator Division
27 United States
Catalog HY10-1630/US Piston Accumulators
Notes
Parker Hannifin
Global Accumulator Division
28 United States
Catalog HY10-1630/US Piston Accumulators
2000
Overview Series 2000 & 3000
3000
Piston
ACP
Series 3000 Piston Accumulators
4000
5000
(and 12" units at 2,000 PSI)
IN THIS SECTION
Overview 29
Specifications & Options 30
Features
• Heavy Duty Service with
3000 PSI Operating Pressure
• 3" thru 12" Bores with More
Than 50 Standard Capacities
• V-O-ring Piston Seals
• Serviceable Threaded End
Construction
• Five Standard Seal Options to
Handle a Variety of Fluids and
Temperatures
• ASME/DNV/ABS/AS1210/
SELO/CRN/GOST/CE
Certifications Available
• Temperature Ranges
-45º to 320ºF
Parker Hannifin
Global Accumulator Division
29 United States
Catalog HY10-1630/US Piston Accumulators
Specifications Series 3000
Parker Hannifin
Global Accumulator Division
30 United States
Catalog HY10-1630/US Piston Accumulators
2000
Options Series 2000 & 3000
3000
Water Service Option (W)
Piston accumulators are available for use with water as the fluid media. Modifications include electroless nickel plating all
Piston
surfaces and metal parts. Consult factory for details.
ACP
Seal Material Options
4000
**Recommended Maximum
Seal General Application
Polymer Operating Temperature with
Code and Compatibility*
Temperature Range Reduced Life
5000
Buna- -20°F to 165°F 200°F Parker’s Standard Compound – Compatible
K
Nitrile -29°C to 74°C 93°C with most mineral oil-based fluids
Fluorocarbon -10°F to 250°F 400°F Compatible with most mineral oil-based fluids at
E
Elastomer -23°C to 121°C 204°C higher temperatures and some exotic fluids
Ethylene -40°F to 250°F 300°F Compatible with most phosphate ester fluids
D
Propylene -40°C to 121°C 149°C and some synthetic fluids
Compatible with most oil-based and
Hydrogenated -25°F to 320°F 350°F
H biodegradable fluids, maintains sealing
Nitrile -32°C to 160°C 177°C
effectiveness at a wide range of temperatures
Compatible with most mineral oil-based fluids
Low Temp. -45°F to 160°F 200°F
Q and maintains sealing effectiveness at
Nitrile -43°C to 71°C 93°C
low temperatures
* Consult local distributor or factory for fluid compatibility information.
** The temperatures listed indicate the operating temperature range of the seals, not the accumulator. For the Minimum Design Metal Temperature
(MDMT) of ASME certified accumulators, refer to page 31.
1/2-20 UNF-2A
L07689000K
by using the “Fuse Adapter” as shown to the right. 4" bore units and
#8 SAE
above can be equipped with a fuse port machined in the gas cap 3/4-16 UNF-2A
1.25
by specifying the “Safety Fuse Option” (F) at the time of order in the #8 SAE
Straight
model code, see “How to Order.” The safety fuse assembly and/or Port Th’d
fuse adapter must be ordered separately.
0.95
0.70
Description Part Number #5 SAE
Straight
Safety Fuse Assembly1 086471xxxx Port Th’d
Replacement Rupture 1.44
3.77
756003xxxx
Disks
Fuse Adapter 1468970002
Parker Hannifin
Global Accumulator Division
31 United States
Catalog HY10-1630/US Piston Accumulators
Models, Capacities & Dimensions Series 3000
3000 PSI (207 Bar Metric) Piston Accumulators for Oil and Water Service
Cored
3 Mounting Holes Note: 3" to 6" are spanner holes
Gas Valve
E Thread 7" to 12" see chart
(see note)
G Depth
F Dia.
D C
Bolt Circle
Threaded Port Flange Port Hydraulic
Port B
Configuration Configuration
(See page 35)
PHASED OUT
A2N0005D1K (D2K) – (0.08) 5 6 (0.11) 6.76 (172) 5 (2.1)
A2N0010D1K (D2K) – (0.16) 10 11 (0.19) 8.31 (211) 5 (2.3)
2.38 1.06
A2N0015D1K (D2K) – (0.25) 15 16 (0.24) 9.78 (250) – – – 6 (3.3)
(60) (27)
A2N0029D1K (D2K) 1 Pint (0.48) 29 30 (0.50) 14.19 (360) 7 (2.6)
A2N0058D1K (D2K) 1 Quart (0.95) 58 59 (0.98) 23.19 (589) 10 (4.7)
A3N0029D1K (D2K) 1 Pint (0.48) 29 34 (0.56) 10.25 (260) 14 (6.5)
A3N0058D1K (D2K) 1 Quart (0.95) 58 63 (1.03) 14.34 (364) 18 (8.1)
3.56 1.13 .39 2.25 0.59
A3N0090D1K (D2K) 1.5 Quart (1.42) 90 95 (1.56) 18.94 (481) 22 (9.8)
(90) (29) (9.9) (60) (15)
A3N0116D1K (D2K) 1/2 Gal. (1.90) 116 121 (1.98) 22.56 (573) 25 (11.1)
A3N0183D1K (D2K) 3 Quart (2.84) 183 188 (3.08) 32.06 (814) 32 (14.6)
A4N0058D1K (D2K) 1 Quart (0.95) 58 68 (1.11) 11.63 (295) 29 (13.0)
A4N0116D1K (D2K) 1/2 Gal. (1.90) 116 126 (2.06) 16.19 (411) 35 (15.9)
4.75 1.13 .45 3.25 0.68
A4N0231D1K (D2K) 1 Gal. (3.79) 231 241 (3.95) 25.19 (640) 48 (21.8)
(121) (29) (11.4) (82) (18)
A4N0347D1K (D2K) 1-1/2 Gal. (5.69) 347 357 (5.85) 34.31 (871) 61 (27.6)
A4N0578D1K (D2K) 2-1/2 Gal. (9.47) 578 588 (9.64) 52.38 (1330) 87 (39.3)
A6N0231D1K (D2K) 1 Gal. (3.79) 231 266 (4.36) 17.38 (441) 83 (37.8)
A6N0578D1K (D2K) 2-1/2 Gal. (9.47) 578 613 (10.0) 30.63 (778) 124 (56.3)
A6N0924D1K (D2K) 4 Gal. (15.1) 924 959 (15.7) 6.88 43.81 (1113) 1.13 .45 4.38 0.84 165 (74.7)
A6N1155D1K (D2K) 5 Gal. (18.9) 1155 1190 (19.5) (175) 52.63 (1337) (29) (11.4) (110) (22) 192 (87.0)
A6N1733D1K (D2K) 7-1/2 Gal. (28.4) 1733 1768 (29.0) 74.63 (1896) 260 (117.8)
A6N2310D1K (D2K) 10 Gal. (37.9) 2310 2345 (38.4) 96.63 (2454) 327 (148.5)
A7N0578D3KPL (D2K) 2-1/2 Gal (9.47) 578 633 (10.4) 27.25 (692) 170 (76.9)
A7N1155D3KPL (D2K) 5 Gal. (18.9) 1155 1210 (19.8) 8.13 42.25 (1073) 226 (103)
A7N1733D3KPL (D2K) 7-1/2 Gal. (28.4) 1733 1788 (29.3) (206.5) 57.25 (1454) 1.63 .625 -18 5.75 0.94 283 (129)
A7N2310D3KPL (D2K) 10 Gal. (37.9) 2310 2365 (38.8) ±0.06 72.25 (1835) (41) (M16) (150) (24) 340 (154)
A7N3465D3KPL (D2K) 15 Gal. (56.8) 3465 3520 (57.7) (±1.52) 102.25 (2597) 454 (206)
A7N5775D3KPL (D2K) 25 Gal. (94.6) 5775 5830 (95.5) 162.25 (4121) 682 (309)
A9K2310D3KPL (D2K) 10 Gal. (37.9) 2310 2400 (39.3) 48.75 (1238) 595 (270)
11.02
A9K3465D3KPL (D2K) 15 Gal. (56.8) 3465 3555 (58.3) 66.94 (1700) 758 (344)
(279.9) 1.63 .75-16 7.00 1.13
A9K4620D3KPL (D2K) 20 Gal. (75.7) 4620 4710 (77.2) 85.06 (2161) 920 (417)
±0.09 (41) (M20) (182) (29)
A9K5775D3KPL (D2K) 25 Gal. (94.6) 5775 5865 (96.2) 103.18 (2622) 1083 (491)
(±2.29)
A9K6930D3KPL (D2K) 30 Gal. (114) 6930 7020 (115.1) 121.37 (3083) 1246 (565)
A12K5775D1K (D2K) 25 Gal. (94.6) 5775 5975 (97.9) 14.41 67.50 (1715) 1336 (606)
.875 - 9
A12K6930D1K (D2K) 30 Gal. (114) 6930 7130 (117) (365.9) 76.31 (1938) 1.63 9.00 1.50 1490 (676)
(M20)
A12K9240D1K (D2K) 40 Gal. (151) 9240 9440 (155) ±0.09 98.88 (2512) (41) (230) (38) 1799 (816)
(6X)
A12K11550D1K (D2K) 50 Gal. (189) 11550 1175 (193) (±2.29) 119.62 (3038) 2108 (956)
The Minimum Design Metal Temperature (MDMT) for ASME certified 7" and 9" piston accumulators presented in this section is 20°F (-7°C).
The Minimum Design Metal Temperature (MDMT) for ASME certified 12" piston accumulators presented in this section is 32°F (0°C).
Piston accumulators are available with MDMT below -40°F (-40°C). Consult factory for options.
Notes:
– For Water Service add “W” after construction code, see “How to – ASME/DNV/ABS/AS1210/SELO/CRN/GOST/CE certified
Order” information. accumulators and gas bottles are available.
– Standard accumulators are designated D1K in model number, metric – When accumulators are to be used with gas bottles, order
are D2K. “Accumulators for Use with Gas Bottles.”
– See “Port Options” for complete listing of standard and optional ports. – 3", 4" & 6" bores standard with cored gas valves.
Poppet type (L07689000K) gas valve available as an option.
Parker Hannifin
Global Accumulator Division
32 United States
Catalog HY10-1630/US Piston Accumulators
2000
Models, Capacities & Dimensions 2000 PSI
3000
2000 PSI (139 Bar Metric) Piston Accumulators for Oil and Water Service
We offer a 2000 PSI accumulator in 12" bore size
Piston
and a variety of capacities for industries where
ACP
lower pressure ratings can be used.
4000
High-Pressure
3 Mounting Holes Poppet-Type
E Thread Gas Valve
G Depth
5000
A
F Dia. D C
Threaded Port Bolt Circle Flange Port Hydraulic
Configuration B
Configuration Port
(See page 35)
Notes:
– For Water Service add “W” after construction code, see “How to – See “Port Options” for complete listing of standard and
Order” information. optional ports.
– Most SAE #32 fittings are rated for 2000 PSI. If 2000 to 3000 PSI – ASME/DNV/ABS/AS1210/SELO/CRN/GOST/CE certified
service is required, two options are available; order accumulator accumulators and gas bottles are available.
with optional standard 2" SAE Code 61 4-bolt flange port by – When accumulators are to be used with gas bottles, order
specifying “PL” code when ordering or order the accumulator with “Accumulators for Use with Gas Bottles.”
a SAE #24 port or smaller. See “Port Options” for dimensions and
– Poppet type (L07689000K) gas valve standard.
“How to Order”.
Parker Hannifin
Global Accumulator Division
33 United States
Catalog HY10-1630/US Piston Accumulators
Port Options Series 2000 & 3000
Optional Ports
The following ports are available as options on all Series 3000 piston accumulators
SAE Straight Thd. Code 61 Flange NPT BSPP ISO 6149-1
Port Port Min. Port Port Code Min. Port Port Min. Port Port Min. Port Port Min.
Size Code Bore Size Inch Metric Bore Size Code Bore Size Code Bore Size Code Bore
#5 TA 3" 1/2" PT MT 3" 3/8" UT 3" 3/8" RA 3" M14 YA 3"
#6 TB 3" 3/4" PU MU 3" 1/2" UU 3" 1/2" RB 3" M18 YB 3"
#8 TC 3" 1" PV MV 3" 3/4" UV 3" 3/4" RC 3" M22 YC 3"
#10 TI 3" 11/4" PW MW 3" 1" UW 3" 1" RD 3" M27 YD 3"
#12 TD 3" 11/2" PJ MJ 4" 11/4" UX 3" 11/4" RE 3" M33 YE 3"
#16 TE 3" 2" PL ML 6" 11/2" UY 4" 11/2" RF 4" M42 YF 3"
#20 TF 3" 21/2" PM MM 6" 2" UZ 4" 2" RG 4" - - -
#24 TG 4" 3" PN MN 7" - - - - - - - - -
Note:
– 3000 PSI SAE Code 61 (ISO 6162) Flange dimensions are shown below.
– BSPT and Metric ports available, consult factory.
F
3" 5/8 -11 2.438 4.188 3 1.188
Note: Some flanges using this bolt pattern are not rated for 3000 PSI.
A (4 places) x
Flange Size Metric ISO6162 Flange Dimensions (mm) G Min. Depth
mm A B C F G
38 M12 35.7 69.9 38 26.9 B
51 M12 42.9 77.8 51 26.9
64 M12 50.8 88.9 64 30.1
76 M16 61.9 106.4 76 30.1
Note: Some flanges using this bolt pattern are not rated for 3000 PSI.
Parker Hannifin
Global Accumulator Division
34 United States
Catalog HY10-1630/US Piston Accumulators
2000
Parts & Accessories Series 2000 & 3000
3000
Seal Kits Parts List
Seal Kits are available for all piston accumulator models. When ordering 1 Body
Piston
seal kits, please supply the complete model and serial numbers from the 2 Hydraulic Cap
ACP
name plate and specify fluid type and operating temperature. 3 Gas Cap
4 Piston
4000
5 V-O-ring Piston Seal
5A V-O-ring Backups
6 PTFE Glide Rings
5000
7 O-ring
7A O-ring Backup
8 Gas Valve
8A Gas Valve O-ring
9 Gas Valve Guard
9A Screw
3000 PSI Seal Kit Numbers (Includes items 5, 5A, 6, 7, 7A, 8A)
Bore Size
Material
2" 3" 4" 6" 7" 9" 12"
Buna-Nitrile (Std.) RK0200K000 RK0300K000 RK0400K000 RK0600K000 RK0700K000 RK0900K000 RK1200K000
Low Temp Nitrile RK0200Q000 RK0300Q000 RK0400Q000 RK0600Q000 RK0700Q000 RK0900Q000 RK1200Q000
*CF = Consult Factory
Special Options
If your application requires a piston accumulator, gas bottle, • Large Bore
or special option that falls outside of Parker's broad offering, • High Pressure
consult your local distributor, Parker representative, or the • Special and Stainless Steel Materials
factory with your specific requirements. Parker has the • Piston Position and Velocity Sensors and Switches
manufacturing and engineering expertise to design and build • Special Seals
piston accumulators to your exacting requirements, from simple
• Non-Standard Capacities
modifications of standard units to complete designs. Some
example of Parker's past special designs include: • Tie Rod Construction
• Special Certifications
• Spring & Weight Loaded
• Extreme Temperatures
Consult the experts at Parker with your next piston accumulator requirement!
Parker Hannifin
Global Accumulator Division
35 United States
Catalog HY10-1630/US Piston Accumulators
Ordering Information Series 2000 & 3000
Nominal
Bore Type of Design Design Seal Hyd. Port Gas Port
Series Size Construction Options Capacity Pressure Number Compound Modification Modification
A 7 K – 2310 D 1 K – – – –
Series Bore Size/Capacity Hydraulic and Gas Port Modifications Designated by 2 Digits
A Accumulator 0029 29 cu. in. (0.48 liters) 1st 2nd Min.
B Gas Bottle 0058 58 cu. in. (0.95 liters) Digit Style Digit Description Bore Size
0090 3" 90 cu. in. (1.47 liters)
0116 116 cu. in. (1.90 liters) Blank Std. Blank Std.
Nominal Bore Size 0183 183 cu. in. (3.00 liters)
3 3 inches 0058 58 cu. in. (0.95 liters) T SAE A SAE #5 .5 - 20 3"
4 4 inches 0116 116 cu. in. (1.90 liters) Straight B SAE #6 .562 - 18 3"
6 6 inches 0231 4" 1 gal. (3.79 liters) Thread C SAE #8 .75 - 16 3"
7 7 inches 0347 1.5 gal. (5.69 liters) Ports D SAE #12 1.0625 - 12 3"
9 9 inches 0578 2.5 gal. (9.47 liters) E SAE #16 1.3125 - 12 3"
12 12 inches 0231 1 gal. (3.79 liters) F SAE #20 1.625 - 12 3"
0347 1.5 gal. (5.69 liters) G SAE #24 1.875 - 12 4"
0578 2.5 gal. (9.47 liters) H SAE #32 2.5 - 12 7"
0924 6" 4 gal. (15.1 liters) I SAE #10 .875 - 14 3"
1155 5 gal. (18.9 liters) Min. Bore
Type of Construction 1733 7.5 gal. (28.4 liters) P Flange J 1 1/2" 4"
2310 10 gal. (37.9 liters) (Code 61) L 2" 6"
N Threaded both ends
non-A.S.M.E. mat’l standard 0578 2.5 gal. (9.47 liters) M 2 1/2" 6"
on 2", 3", 4", 6", & 7" 1155 5 gal. (18.9 liters) M Metric N 3" 7"
(3000 PSI fatigue design 1733 7" 7.5 gal. (28.4 liters) Flange T 1/2" 3"
tested) 2310 10 gal. (37.9 liters) per U 3/4" 3"
3465 15 gal. (56.8 liters) ISO 6162 V 1" 3"
K Threaded both ends A.S.M.E. W 1 1/4" 3"
5775 25 gal. (94.6 liters)
mat’l standard, NOT A.S.M.E.
stamped on 7" & up 2310 10 gal. (37.9 liters) T 3/8" 3"
3465 15 gal. (56.8 liters) U NPTF U 1/2" 3"
L Same as K with A.S.M.E. 4620 9" 20 gal. (75.7 liters) (Not V 3/4" 3"
approval stamp 7" & up. 5775 25 gal. (94.6 liters) Recommended) W 1" 3"
Available as special on 6930 30 gal. (113.6 liters) X 1 1/4" 3"
smaller sizes Y 1 1/2" 4"
5775 25 gal. (94.6 liters)
E Threaded both ends, 6930 12" 30 gal. (114 liters) Z 2" 4"
CE marked (1 liter and 9240 40 gal. (151 liters) BSPP/BSPT Metric/ISO 6149-1
above) or SEP marked 11550 50 gal. (189 liters) R BSPP A 3/8 - 19 A M14 x 1.5
(under 1 liter) Parallel B 1/2 - 14 B M18 x 1.5
Consult factory for other available sizes.
B BSPT C 3/4 - 14 C M22 x 1.5
Taper Port D 1 - 11 D M27 x 2
G Metric E 1 1/4 - 11 E M33 x 2
Options Design Pressure
Y ISO F 1 1/2 - 11 F M42 x 2
Blank Standard Gas Cap D 3000 PSI (All Bore Sizes) 6149-1 G 2 - 11 G M48 x 2
W Water Service K 2000 PSI (12" Bore only)
X Other
F SAE Fuse Port *
For CE Marked Only Example of Optional Port Accumulator
G SAE Fuse Port *, L 250 Bar (All Bore Sizes) A 4 N 0231 D 3 K T C U V
Water Service H 350 Bar (See page 50)
M L07689000K Gas Valve Non-std. SAE #8 NPT 3/4"
K L07689000K Gas Valve, Port Hyd. Port Gas Port
Water Service To order safety fuse and rupture
disk installed on the accumulator
P SAE Fuse Port*
add the rupture pressure to the
and L07689000K
end of the model number.
R SAE Fuse Port* and Standard Ports Available
L07689000K, Water Service Example: A7LF2310D3KPL-3000. (See Port Modifications Table if Using Seal Compound
* Safety fuse assembly not included. Rupture disks are available in 100 Other Than Standard Ports Shown Below) (See Catalog for
Note: ASME and CRN units available psi increments starting at 3000 psi. Bore Standard Metric Temperature Settings)
upon request. Size Port Sizes Port Sizes K Buna-Nitrile (Std)
3" SAE #12 3/4 E Fluoroelastomer
Design Number D EPR
4" SAE #20 1
1 Standard 6" SAE #24 1 H Hydrogenated
2 Metric Mounting Holes & Hyd. Port 7" SAE #32 ISO 6162 Nitrile
(BSPP Standard) Specify Optional Ports 9" SAE #32 ISO 6162 Q Low Temp.
12" 3" SAE Flange ISO 6162 S Special
3 Optional Port (Hyd. or Gas, See Port Table)
Code 61 (to be specified)
*** Special Design
Parker Hannifin
Global Accumulator Division
36 United States