Heat Recovery Ventilator: Enhanced Efficiency Multiple Modes

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

VRF

HEAT RECOVERY VENTILATOR

Flexible control

ENHANCED EFFICIENCY MULTIPLE MODES


The Midea heat recovery ventilator (HRV) can Heat Exchange Mode: The flows of incoming and
greatly reduce energy losses and room temperature outgoing air pass close to each other, allowing heat
fluctuations caused by the ventilation process. transfer between the two channels. During summer,
Temperature exchange efficiency is over 74% and incoming air is cooled by the indoor air being
enthalpy exchange efficiency is over 76%. exhausted and in winter, incoming air is warmed.
Bypass Mode: Supply and exhaust fans run at the
LOW NOISE same speed. In mild climates, where temperature
Soundproofing is used to guarantee quiet operation. and humidity differences between indoor and
outdoor are small, the HRV can work as a
FLEXIBLE CONTROL conventional ventilation fan.
HRV can be controlled together with other indoor Air Supply Mode: Supply fan runs faster than
units. Heights starting from as little as 264mm and exhaust fan. A mode suitable in mild climate
weights from as little as 23kg mean that the HRV can installations with fresh air ventilation requirements.
be easily installed where space is limited.
Exhaust Mode: Exhaust fan runs faster than supply
fan. A mode suitable in mild climate installations
with large amounts of exhaust air to be expelled.
Auto Mode: The controller chooses Heat Exchange
mode or Bypass mode according to temperature
difference between outdoors and indoors. Both fans
run at low speed.
VRF HEAT RECOVERY VENTILATOR

Indoor unit: HRV-D200/300/400/500/800/1000 Indoor unit: HRV-D1500/2000

MODEL HRV-D200 HRV-D300 HRV-D400 HRV-D500 HRV-D800 HRV-D1000 HRV-D1500 HRV-D2000


Power supply 1-phase,220-240V,50/60Hz
Recommended Fuse Size A 5 5 5 5 5 10 10 10
Temp. exchange efficiency % 76.1 74.8 76.2 76.1 76.9 75.8 77.8 77.2
Cooling
Enthalpy exchange efficiency % 77.3 76.1 78.7 78.2 78.1 76.9 79.2 78.7
Temp. exchange efficiency % 76.1 74.8 76.2 76.1 76.9 75.8 77.8 77.2
Heating
Enthalpy exchange efficiency % 82.6 79.8 83.6 80.4 80.1 78.6 80.5 80.3
Current A 0.72 0.99 1.07 1.56 2.28 3.1 5.29 9.11
Model WZDK100-38G-1 WZDK100-38G-1 WZDK100-38G-1 WZDK100-38G-1 WZDK170-38G-2 WZDK170-38G-2 WZDK750-38G-W-1 WZDK750-38G-W-1
Insulation class E
Indoor fan motor Output W 26*2 42*2 46*2 72*2 104*2 153*2 308*2 570*2
Pole number 8P 8P 8P 8P 8P 8P 8P 8P
Speed r/min 1390 1390 1390 1380 1150 1230 1220 1390
Material ABS metal
Type Centrifugal fan
Indoor fan
Diameter mm Φ154 Φ194 Φ194 Φ203 Φ245 Φ245 Φ234 Φ234
Height mm 102 100 100 151 203 203 261 261
Indoor external static pressure (Hi) Pa 75 75 80 80 100 100 160 170
Nominal air flow m3/h 200 300 400 500 800 1000 1500 2000
Sound pressure level dB(A) 27 30 32 32 35 36 46 48
Net dimension (LxWxH) mm 852×665×264 928×734×270 928×940×270 1020×1036×270 1276×1020×388 1276×1269×388 1600×1270×540 1650×1470×540
Packing size (LxWxH) mm 930×730×445 1010×800×450 1010×1010×450 1120×1120×452 1380×1100×573 1390×1350×580 1680×1350×720 1760×1580×720
Net/Gross weight kg 25/40 27/44 32/52 35/60 58/88 69/100 151/224 165/247
Wire’s qty 3 3 3 3 3 3 3 3
Power supply wire
Code wire cross section mm2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Fresh Air diameter mm Φ144 Φ144 Φ144 Φ194 Φ242 Φ242 346×326 346×326
Operating temperature range °C -7~43DB, 80%RH or less
For the units model of HRV-D200~HRV-D2000, there are 3-speed adjustable air-volume (Hi, Med, Low). Efficiency is measured under the following conditions:
All the parameters is measured at the high speed air-volume. * Cooling: air exhaust temp 27°C DB, 19.5°C WB; fresh air temp. 35°C DB, 28°C WB.
Sound Pressure is measured 1.5m below the air-outlet at Nominal Conditions. * Heating: air exhaust temp 21°C DB, 13°C WB; fresh air temp. 5°C DB, 2°C WB.

FG EUROPE UK LTD
17 Old Park Lane, London W1K 1QT, United Kingdom
T: +44 (0)207 409 2009 | E: info@fgeuropeuk.co.uk | W: www.mideauk.co.uk