Loads and Load Combinations
Loads and Load Combinations
Loads and Load Combinations
Loads specified in the codes are "nominal" (normal or service level loads) except seismic which is an
ultimate load. The code tells you what loads should be included in the design of the structure.
DL = Dead load
E = Seismic or earthquake load
F = Load do to fluids, such as an elevated water tank
Fa = Flood load
H = Load due to lateral earth pressure
LL = Live load
Lr = Roof live load
S = Snow load
R = Rain load
WL = Wind load
Load combinations tell you how to combine the loads to determine the worst case loading for a member.
No matter what material or method of design you must use load combinations. If you are design using
strength design or load and resistance factor design you use the "ultimate" load combinations. If you are
using allowable stress design you use the basic combinations for "service" loads.
Notes for both sets of load combinations. The combinations are based on probability. The probability of
having 100% of the floor live load occurring at the same time as 100% of the roof live load or snow load
or rain load is very small and therefore you do not include 100% of both floor and roof load in any
combinations. Same with floor live loads and wind or seismic loads.
The combinations are all additive; there are no combinations with negative signs in them. It is up to
YOU to use proper algebraic notation with the LOADS so that the load combinations come out correctly.
In English: WL and E may be left to right or right to left upward or downward acting. If you assign a
downward acting dead load a positive sign then the combinations starting with 0.6DL or 0.9DL should
use a negative sign for upward acting WL or E to determine the maximum net uplift force.
Strength Design Load Combinations
IBC section 1605.2.1 and ASCE 7 section 2.3 provide load combinations for use with strength
design and resistance factor design (their wording). Steel uses the term LRFD (load resistance
factored design) and concrete uses USD (ultimate strength design) for “strength design”. The
service loads are multiplied by load factors to determine ultimate loads. These are then compared
to the ultimate strength of the material being used for the member. The basic combinations are:
1.4DL
1.2DL + 1.6LL or 1.2DL + 1.6LL + 0.5(Lr or S or R)
1.2DL + 1.6(Lr or S or R) + (f1LL or 0.8WL)
1.2DL + 1.6WL + f1LL + 0.5(Lr or S or R)
1.2DL + 1.0E +f1L + f2S
0.9DL + 1.6WL
0.9DL + 1.0E
Loads and Load Combinations