ULB-362 ULB362/PL Series Underwater Locator Beacon: User's Manual
ULB-362 ULB362/PL Series Underwater Locator Beacon: User's Manual
ULB-362 ULB362/PL Series Underwater Locator Beacon: User's Manual
ULB362/PL
Series Underwater
Locator Beacon
User’s Manual
May 2015
P/N: 362-17001-A
Tel: +1-949-727-9399
Fax: +1-949-727-0070
e-mail: [email protected]
ULB-362 Underwater Locator Beacon i
Preface
This manual describes the installation and operation of the ULB-362
Series Underwater Locator Beacons used for marking underwater
locations, equipment and subsea vehicles. This manual is divided into the
following six sections:
1 Description
2 Specifications
3 Installation and Checkout
4 Beacon Maintenance
5 Return Procedures
6 Warranty
Proprietary Information
The information, description, and illustrations in this manual are the
property of RJE International, Inc. Materials may not be reproduced or
disseminated without the prior written consent of RJE International, Inc.
Changes
RJE International, Inc. reserves the right to make changes to meet new
specifications at any time without incurring any obligation to modify
previously installed units. This manual is provided for informational and
reference purposes only and is subject to change without notice.
Table of Contents
1 Description ....................................................................................................................1
2 Specifications ..............................................................................................................4
Bracket ...............................................................................................................................6
Pre-Deployment Tests..........................................................................................9
Using ATS-260 Acoustic Test Set with the ULB-362B ................................................9
Using ATS-260 Acoustic Test Set with the ULB-362PL/B37 ..................................... 10
ATS-260 Acoustic Test Set Service ........................................................................... 11
Alternative Battery Check ........................................................................................ 11
4 Beacon Maintenance.............................................................................................. 13
6 Warranty ....................................................................................................................... 16
List of Figures
Figure 1-1 ULB-362B/37 ...........................................................................................................1
Figure 1-2 Installed in Mounting Bracket .................................................................................2
Figure 1-3 Dimensions ...............................................................................................................2
Figure 1-4 Locating the ULB-362 After Water Activation .........................................................3
Figure 3-1 Mounting Bracket Hole Pattern ...............................................................................6
Figure 3-2 Securing the Mounting Bracket ...............................................................................7
Figure 3-3 Installing the Beacon into the Mounting Bracket ....................................................7
Figure 3-4 Wiring Diagram of the ULB-362PL/B37 .................................................................8
Figure 3-5 Connecting the ATS-260 Acoustic Test Set ............................................................ 11
1 Description
The ULB-362 Series Underwater Locator Beacons are durable, water-activated,
underwater location aids. A Power Loss version is also available. The ULB-362
series beacons can also be order in several frequencies, 27kHz, 37.5kHz and
45kHz. The beacons transmit an acoustic signal once every second after
activation. The acoustic output for the 30 day battery will remain above 157.0 dB
for 30 days.
RJE International, Inc. also offers a standard mounting bracket (P/N B362-
05591). The bracket allows the beacon to be securely mounted (Please contact
RJE International, Inc. if the mounting bracket does not meet your needs). The
ULB-362 beacon is shown in Figure1-1. The beacon is also shown installed in its
standard mounting bracket in Figure 1-2, and a dimensional outline of the beacon
is shown in Figure 1-3.
This section provides a general descriptive overview of the beacon, its theory of
operation, and use.
External Construction
The beacon is contained in a water-tight aluminum case capable of
withstanding high-impact shock and deep-water immersion. As shown in
Figure 1-2, one of the end caps has a water-activated built in switch that
causes the beacon to begin transmitting when the switch comes in contact
with water.
Internal Construction
The major internal components of the beacon include a printed circuit board
assembly, a urethane-encapsulated transducer assembly, and a battery. The
battery is contained in its own, separate, user accessible compartment.
Theory of Operation
The printed circuit board assembly generates all the necessary logic functions
to produce a pulse with the desired characteristics. The pulse is then
transformed from a CMOS level square wave to a much larger sinusoidal
pulse by a transformer. The output of the transformer drives the urethane-
encapsulated transducer, which propagates through the housing in the form
of a tuned acoustic signal based on the frequency of the beacon (27kHz,
37.5kHz, or 45kHz).
2 Specifications
ULB-362B/27, ULB-362B/37, Specifications ULB-362PL/B37
ULB-362B/45
0 to 20,000 feet (6,096 meters) Operating Depth: 0 to 20,000 feet (6,096 meters)
≥ 9 ms Pulse Length: ≥ 9 ms
1.30 in. (3.30 cm) diameter Case Size: 1.30 in. (3.30 cm) diameter
3.92 in (10 cm) long 3.92 in (10 cm) long
-55ºC (-67ºF) to 71ºC (160ºF) Storage Temperature: -55ºC (-67ºF) to 71ºC (160ºF)
-2ºC (28ºF) to 38ºC (100ºF) Operating Temperature: -2ºC (28ºF) to 38ºC (100ºF)
Installation Considerations
To minimize the probability of physical damage or inadvertent activation, the
following precautions should be considered when mounting the beacon:
The beacon should normally be mounted in to a sturdy structure without
weakening the structure itself.
The shelf life of the battery will be decreased when exposure to higher
than normal temperatures. The maximum temperature where the beacon
is mounted should not exceed 71ºC (160º F).
1. Ensure the beacon is mounted in the vehicle so that it has a clear path to send
the acoustic signal. Avoid mounted it behind other equipment.
2. Mount the beacon with the water switch down to prevent accidental activation.
3. Refer to the mounting bracket hole pattern shown in Figure 3-1 and drill four
0.191 in (0.48 cm) diameter holes.
4. Secure the mounting bracket with four 10-32 stainless steel screws and
associated hardware (not supplied) as shown in Figure 3-2.
5. Slide the beacon into the bracket as shown in Figure 3-3. Rotate the beacon
until the battery date is visible and secure it in place with the end plate and the
three drilled socket head cap screws.
6. Lockwire the drilled screws and clean the water activation switch (refer to section
4 Beacon Cleaning).
1. Ensure the beacon is mounted in the vehicle so that it has a clear path to send
the acoustic signal. Avoid mounted it behind other equipment.
2. Mount the beacon with the water switch down to prevent accidental activation.
3. Male E/O Pigtail Connector, Provided with the unit, is wired to Vehicle’s
electronics module through a penetrator.
Pre-Deployment Tests
A pre-deployment test on each beacon should be performed before and after
mounting using the RJE International, Inc. Short out the water switch and use a
acoustic pinger receiver to determine if the beacon is functioning.
For the ULB-362B series beacon, the ATS-260 Acoustic Test Set can be used to
check both the beacon’s battery condition and operation. Also, an alternative
method using a digital voltmeter can be used to check the beacon’s battery
condition.
To use the ATS-260 Acoustic Test Set to verify the battery condition and test the
operations of the beacon, use the following procedure:
1. Place the clip for the test set on the housing of the beacon as shown
in Figure 3-5. If using the B362-05591 channel mount, it is not
necessary to remove the beacon to conduct the test.
2. Place the test set probe on the water activation switch as shown in
Figure 3-5.
3. Hold down the button labeled PUSH TO TEST on the test set handle.
4. Check the beacon battery condition by observing the green and red
indicators on the test set.
To use the ATS-260 Acoustic Test Set to verify the battery condition and test the
operations of the beacon, use the following procedure:
1. Place the clip for the test set on the housing of the beacon as shown
in Figure 3-4. If using the B362-05591 channel mount, it is not
necessary to remove the beacon to conduct the test.
2. Close the contacts that short the two conductors of the pig-tale
connector to indicate a ‘loss-of-power’ as shown in fig 3-5. If the pig-
tale is not wired to the vehicle, short the two conductors.
3. Place the test set probe on the water activation switch as shown in
Figure 3-5.
4. Hold down the button labeled PUSH TO TEST on the test set handle.
5. Check the beacon battery condition by observing the green and red
indicators on the test set.
NOTE: If the beacon does not operate properly, return it RJE International,
Inc. for service. (See Section 5 Return Procedures
for instructions on how to return the beacon.)
The ATS-260 Acoustic Test Set is factory calibrated at the date of manufacture,
and must be recalibrated every 36 months. When the "Push to Test" button is
pressed and no light illuminates or is dim, the ATS-260 must be serviced. (See
Section 5 Return Procedures for instructions on how to return the test set.)
In addition to using the test set to check the beacon’s battery condition, a high-
impedance (minimum input impedance of 10 Megohms) digital voltmeter can be
used to measure the battery voltage. Use the following procedure to measure
the battery voltage:
2. Place the positive meter lead on any exposed surface of the housing.
4 Beacon Maintenance
This section covers the cleaning, recommended testing interval, disposal,
storage procedures, and battery replacement for the ULB-362 Series
Underwater Locator Beacons.
Beacon Cleaning
The end cap with the water switch should remain free and clear of dirt,
grease, and dust. The beacon should be cleaned with a mild detergent and
dried thoroughly with a clean cloth. This process should be repeated
periodically depending on the local environment.
Any situation that could possibly crush or penetrate the case of the
beacon should be avoided.
Battery Maintenance
The shelf life on the ULB-362 beacon is six (6) years. The standard
operational life of the beacon is thirty (30) days of continuous use and it is
recommended that the battery be replaced after every deployment.
When replacing the battery on ULB-362 beacon, please follow the chart
below for selecting the proper Battery Kit.
Use the battery replacement procedure provided with the lithium battery
replacement kit P/N B362-B30-01 or B362-A30-01.
Beacon Disposal
If it is necessary to dispose of the beacon, perform the Alternative Battery
Check referenced in Section 3 of this User’s Manual first.
If the battery voltage is 6.0 volts or more, remove the battery and dispose of
the battery and beacon in accordance with local regulations.
If the battery voltage is less than 6.0 volts, DO NOT remove the battery
access end cap and dispose of the beacon in accordance with local
regulations.
Beacon Storage
When long-term storage is required, the beacon should be stored in a cool,
dry environment in its original shipping container.
5 Return Procedures
If you need to return an ULB-362 Underwater Locator Beacon for warranty
service, contact RJE International, Inc. for a Case Number and shipping
instructions.
You will need to provide the following information to receive a Case Number:
6 Warranty
LIMITED WARRANTY. RJE International, Inc. warrants that the products sold hereunder shall be free
from defects in materials and workmanship under normal use and service when correctly installed, used
and maintained for a period of 12 months from date of shipment from RJE International, Inc. Purchaser’s
receipt of any product delivered hereunder shall be an unqualified acceptance of and a waiver by
Purchaser of the right of Purchaser to make a claim with respect to such product unless Purchaser gives
RJE International, Inc. notice of any claim within 12 months after the receipt of such product. This
warranty is limited to repair or replacement of the said product at RJE International, Inc. plant in Irvine,
California, providing the product was not abused or operated other than in accordance with the RJE
International, Inc. instruction manuals. RJE International, Inc. does not assume responsibility for any
damage due to leakage or implosion. RJE International, Inc. reserves the right to modify its warranty at
any time, in its sole discretion. THIS LIMITED WARRANTY IS NOT TRANSFERABLE.
THE LIMITED WARRANTY OF RJE INTERNATIONAL, INC. GIVES PURCHASER SPECIFIC LEGAL
RIGHTS, AND PURCHASER MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO
STATE. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY
LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO PURCHASER.