0% found this document useful (0 votes)
88 views15 pages

Computer Controlled Centrifugal Pump Bench, With SCADA: Edibon System

The document describes a computer controlled centrifugal pump bench with SCADA system. The bench includes a centrifugal pump, feed water tank, circulation pipes, regulation valves, pressure sensors, and flow sensor. It allows measuring pump parameters like speed, flow, pressure, torque, and calculated values. The system is supplied with control software for computer control, data acquisition, and data management. It provides experiments on obtaining characteristic curves and parameters of a centrifugal pump.

Uploaded by

GAYATHRI S
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views15 pages

Computer Controlled Centrifugal Pump Bench, With SCADA: Edibon System

The document describes a computer controlled centrifugal pump bench with SCADA system. The bench includes a centrifugal pump, feed water tank, circulation pipes, regulation valves, pressure sensors, and flow sensor. It allows measuring pump parameters like speed, flow, pressure, torque, and calculated values. The system is supplied with control software for computer control, data acquisition, and data management. It provides experiments on obtaining characteristic curves and parameters of a centrifugal pump.

Uploaded by

GAYATHRI S
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Computer Controlled Centrifugal Pump Bench,

with SCADA
Engineering and Technical
Teaching Equipment PBCC

Teaching
Technique
used

EDIBON SCADA System

Computer
(not included in
2 3 4 the supply)
Control Interface Data Software for:
Box Acquisition - Computer Control
Board - Data Acquisition
- Data Management
5 Cables and Accessories
6 Manuals

* Minimum supply always includes: 1 + 2 + 3 + 4 + 5 + 6


(Computer not included in the supply)

1 Unit: PBCC. Computer Controlled Centrifugal Pump Bench

Key features:
hh Advanced Real-Time SCADA.
hh Open Control + Multicontrol + Real-Time Control.
hh Specialized EDIBON Control Software based on LabVIEW.
hh National Instruments Data Acquisition board (250 KS/s, kilo samples per second).
hh Calibration exercises, which are included, teach the user how to calibrate a
sensor and the importance of checking the accuracy of the sensors before taking
measurements.
hh Projector and/or electronic whiteboard compatibility allows the unit to be
explained and demonstrated to an entire class at one time.
hh Capable of doing applied research, real industrial simulation, training courses,
etc.
hh Remote operation and control by the user and remote control for EDIBON technical
support, are always included.
hh Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic &
Software).
hh Designed and manufactured under several quality standards.
hh Optional ICAI software to create, edit and carry out practical exercises, tests,
exams, calculations, etc. Apart from monitoring user's knowledge and progress
reached.
hh This unit has been designed for future expansion and integration. A common
expansion is the EDIBON Scada-Net (ESN) System which enables multiple students
to simultaneously operate many units in a network.

http://www.edibon.com/products/catalogues/en/keyfeatures.pdf http://www.youtube.com/embed/CEgMr00oBPw
For more information about Key Features, click here

ISO 9001: Quality Management (for European Union Certificate Certificates ISO 14001 and ECO- “Worlddidac Quality Charter”
Design, Manufacturing, Commercialization (total safety) Management and Audit Scheme and Platinum Member of
and After-sales service) (environmental management) Worlddidac
1
INTRODUCTION

A hydraulic pump or water pump is a generating machine that transforms the energy with which it is driven (usually mechanical energy) into
the hydraulic energy to move an incompressible fluid. As the energy of the fluid increases, the pressure, speed or head of the fluid increases
too, since they are related according to Bernoulli’s principle. In general, a pump is used to increase the pressure of a liquid, adding energy
to the hydraulic system to move the fluid from a lower pressure zone to a higher pressure zone.
The shape of the impeller determines the type of pump and provides specific characteristics. The most common types of pumps, according
to the impeller, are the positive displacement or volumetric pumps and the rotodynamic pumps:
- The volumetric pumps (gear pumps, piston pumps, screw pumps, etc.) confine a finite volume of fluid between their mechanical
components and, once the fluid is tightly enclosed, they displace or impel it towards the higher pressure area. Therefore, in this type
of pumps there is a clearly defined physical border between the high pressure and low pressure areas.
- The rotodynamic pumps (axial pumps, diagonal pumps, centrifugal pumps, etc.) achieve the pressure increment by forcing the fluid
to move through the divergent ducts found between the vanes of the runner due to the effect of the centrifugal force to which the
fluid is subjected with the rotation of the runner or impeller. As a consequence, in this type of pumps there is no clearly defined
physical border between the high pressure and low pressure areas, but the pressure increases progressively as the fluid advances.
The Computer Controlled Centrifugal Pump Bench, “PBCC”, has been designed to obtain the most important characteristics curves and
parameters of a centrifugal pump. The centrifugal pump is the machine most commonly used to move liquids from one place to another.

GENERAL DESCRIPTION

The Computer Controlled Centrifugal Pump Bench, “PBCC”, is a bench-top unit consists of a centrifugal
pump computer controlled, a feed water tank, circulation pipes, regulation valves, as well as the
enough control elements for the pump experiments: two pressure sensors and a flow sensor.
A frequency inverter for the pump, computer controlled, provides the possibility of regulation and
measuring the pump motor speed, as well as the measurement of the torque transferred.
The pump is installed in a pipes system which avoids the permanent water spending during the operation
because it is a closed circuit.
The Computer Controlled Centrifugal Pump Bench, “PBCC”, unit has instrumentation and sensors to
allow the measurement, from the computer, of the most typical parameters of the centrifugal pump:
- Speed motor.
- Total impelled flow.
- The admission and discharge pressure.
- Torque.
- Calculated values:
Total height.
Hydraulic and mechanic power. PBCC detail
Efficiency.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a
Control Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and Data Management Software Packages, for
controlling the process and all parameters involved in the process.

PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION

2 www.edibon.com
COMPLETE TECHNICAL SPECIFICATIONS (for main items)

With this unit there are several options and possibilities:


- Main items: 1, 2, 3, 4, 5 and 6.
- Optional items: 7, 8, 9, 10 and 11.
Let us describe first the main items (1 to 6):
1 PBCC. Unit:

Bench-top unit.
Anodized aluminum frame and panels made of painted steel.
Main metallic elements made of stainless steel.
Diagram in the front panel with distribution of the elements similar to the real one.
Centrifugal pump, computer controlled:
Maximum flow: 80 l/min.
Maximum height (approx.): 20 mwc.
Pump-and-engine-set coupled to an AC motor.
Two regulation valves.
Torque measurement and speed measurement.
Discharge pressure sensor, range: 0 – 2.5 bar.
Admission pressure sensor, range: -1 – 0 bar.
Flow sensor, range: 0 – 150 l/min.
Water transparent tank, capacity: 60 l.
The complete unit includes as well:
Unit: PBCC
Advanced Real-Time SCADA.
Open Control + Multicontrol + Real-Time Control.
Specialized EDIBON Control Software based on LabVIEW.
National Instruments Data Acquisition board (250 KS/s, kilo samples per second).
Calibration exercises, which are included, teach the user how to calibrate a sensor and the
importance of checking the accuracy of the sensors before taking measurements.
Projector and/or electronic whiteboard compatibility allows the unit to be explained and
demonstrated to an entire class at one time.
Capable of doing applied research, real industrial simulation, training courses, etc.
Remote operation and control by the user and remote control for EDIBON technical support,
are always included.
Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).
Designed and manufactured under several quality standards.
Optional ICAI software to create, edit and carry out practical exercises, tests, exams,
calculations, etc. Apart from monitoring user's knowledge and progress reached.
This unit has been designed for future expansion and integration. A common expansion is
the EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously
operate many units in a network.

3 www.edibon.com
Complete Technical Specifications (for main items)

PBCC/CIB. Control Interface Box:


The Control Interface Box is part of the SCADA system.
Control interface box with process diagram in the front panel and with the same distribution that
the different elements located in the unit, for an easy understanding by the student.
All sensors, with their respective signals, are properly manipulated from -10V. to +10V. computer
output.
Sensors connectors in the interface have different pines numbers (from 2 to 16), to avoid
connection errors.
Single cable between the control interface box and computer.
The unit control elements are permanently computer controlled, without necessity of
changes or connections during the whole process test procedure.
Simultaneous visualization in the computer of all parameters involved in the process.
Calibration of all sensors involved in the process.
Real time curves representation about system responses.
Storage of all the process data and results in a file.
Graphic representation, in real time, of all the process/system responses.
All the actuators’ values can be changed at any time from the keyboard allowing the
analysis about curves and responses of the whole process.
All the actuators and sensors values and their responses are displayed on only one screen in the
computer. PBCC/CIB
Shield and filtered signals to avoid external interferences.
Real time computer control with flexibility of modifications from the computer keyboard of the
parameters, at any moment during the process.
Real time computer control for pumps, compressors, heating elements, control valves, etc.
Real time computer control for parameters involved in the process simultaneously.
Open control allowing modifications, at any moment and in real time, of parameters involved in the
process simultaneously.
Three safety levels, one mechanical in the unit, another electronic in the control interface and
the third one in the control software.
3 DAB. Data Acquisition Board:
The Data Acquisition board is part of the SCADA system.
PCI Express Data acquisition board (National Instruments) to be placed in a computer slot. Bus
PCI Express.
Analog input:
Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536.
Sampling rate up to: 250 KS/s (kilo samples per second).
Input range (V)=±10 V. Data transfers=DMA, interrupts, programmed I/0. DMA channels=6.
Analog output:
Number of channels=2. Resolution=16 bits, 1 in 65536.
Maximum output rate up to: 900 KS/s. DAB
Output range (V)=±10 V. Data transfers=DMA, interrupts, programmed I/0.
Digital Input/Output:
Number of channels=24 inputs/outputs. D0 or DI Sample Clock frequency: 0 to 100 MHz.
Timing: Number of Counter/timers=4. Resolution: Counter/timers: 32 bits.

4 PBCC/CCSOF. Computer Control + Data Acquisition + Data Management Software:


The three softwares are part of the SCADA system.
Compatible with actual Windows operating systems. Graphic and intuitive simulation of the
process in screen. Compatible with the industry standards.
Registration and visualization of all process variables in an automatic and simultaneous way.
Flexible, open and multicontrol software, developed with actual windows graphic systems,
acting simultaneously on all process parameters.
Management, processing, comparison and storage of data.
Sampling velocity up to 250 KS/s (kilo samples per second).
Calibration system for the sensors involved in the process.
It allows the registration of the alarms state and the graphic representation in real time.
Comparative analysis of the obtained data, after the process and modification of the conditions
during the process.
Open software, allowing the teacher to modify texts, instructions. Teacher’s and
student’s passwords to facilitate the teacher’s control on the student, and allowing the access to PBCC/CCSOF
different work levels.
This unit allows the 30 students of the classroom to visualize simultaneously all the results
and the manipulation of the unit, during the process, by using a projector or an electronic
whiteboard.
5 Cables and Accessories, for normal operation.

6 Manuals:
This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface and
Control Software, Starting-up, Safety, Maintenance, Calibration & Practices Manuals.

*References 1 to 6 are the main items: PBCC + PBCC/CIB + DAB + PBCC/CCSOF + Cables and Accessories + Manuals are included
in the minimum supply for enabling normal and full operation.
4 www.edibon.com
EXERCISES AND PRACTICAL POSSIBILITIES TO BE DONE WITH THE MAIN ITEMS

1.- Demonstration of a centrifugal water pump in operation. 11.-The Computer Control System with SCADA allows a real industrial
2.- Introduction to pump speed laws. simulation.
3.- Obtaining of curves H(Q), N(Q) and Eff%(Q). 12.-This unit is totally safe as uses mechanical, electrical/electronic,
and software safety devices.
4.- Simultaneous representation of H(Q), N(Q) and Eff%(Q).
13.-This unit can be used for doing applied research.
5.- Obtaining the map of a centrifugal pump.
14.-This unit can be used for giving training courses to Industries even
6.- Adimensional study of magnitudes H *, N * and Q *. to other Technical Education Institutions.
7.- Cavitation test and obtaining of curves NPSHr. 15.-Control of the PBCC unit process through the control interface
Additional practical possibilities: box without the computer.
8.- Sensors calibration. 16.-Visualization of all the sensors values used in the PBCC unit
Other possibilities to be done with this Unit: process.
9.- Many students view results simultaneously. - By using PLC-PI additional 19 more exercises can be done.
To view all results in real time in the classroom by means of a - Several other exercises can be done and designed by the user.
projector or an electronic whiteboard.
10.-Open Control, Multicontrol and Real Time Control.
This unit allows intrinsically and/or extrinsically to change the
span, gains; proportional, integral, derivative parameters; etc,
in real time.

REQUIRED SERVICES DIMENSIONS AND WEIGHTS

- Electrical supply: single-phase 200 VAC – 240 VAC/50 Hz or PBCC:


110 VAC – 127 VAC/60 Hz. Unit:
-Water supply and drainage. -Dimensions: 1500 x 700 x 800 mm approx.
-Computer. (59.05 x 27.56 x 31.49 inches approx.)
-Weight: 40 Kg approx.
(198 pounds approx.)
Control-Interface Box:
-Dimensions: 490 x 330 x 310 mm approx.
(19.29 x12.99 x12.20 inches approx.)
-Weight: 10 Kg approx.
(22 pounds approx.)

AVAILABLE VERSIONS

Offered in this catalogue:


-PBCC. Computer Controlled Centrifugal Pump Bench.
Offered in other catalogue:
-PBCB. Centrifugal Pump Bench.

5 www.edibon.com
SOFTWARE MAIN SCREENS

SCADA
Main screen
I II

V
III

IV

I Main software operation possibilities.

II Sensors displays, real time values, and extra output parameters. Sensors: SP=Pressure sensor. SC=Flow Sensor. TORQUE=torque.

III Actuators controls. Actuator: AB=Pump.


IV Channel selection and other plot parameters.
V Real time graphics displays.

Software for Sensors Calibration


Example of screen

The teacher and the students can calibrate the unit with
a password provided by EDIBON. The teacher can
restore the factory calibration any time.

6 www.edibon.com
SOME REAL RESULTS OBTAINED FROM THIS UNIT

Example of graphical representation of the sensors values of the unit.

7 www.edibon.com
COMPLETE TECHNICAL SPECIFICATIONS (for optional items)

Additionally to the main items (1 to 6) described, we can offer, as optional, other items from 7 to 11.
All these items try to give more possibilities for:
a) Industrial configuration. (PLC)
b) Technical and Vocational Education configuration. (ICAI and FSS)
c) Multipost Expansions options. (MINI ESN and ESN)

a) Industrial configuration
7 PLC. Industrial Control using PLC (it includes PLC-PI Module plus PLC-SOF Control Software):
-PLC-PI. PLC Module:
Metallic box.
Circuit diagram in the module front panel.
Front panel:
Digital inputs (X) and Digital outputs (Y) block:
16 Digital inputs, activated by switches and 16 LEDs for confirmation (red).
14 Digital outputs (through SCSI connector) with 14 LEDs for message (green).
Analog inputs block:
16 Analog inputs (-10 V. to + 10 V.) (through SCSI connector).
Analog outputs block:
4 Analog outputs (-10 V. to + 10 V.) (through SCSI connector).
Touch screen:
High visibility and multiple functions. Display of a highly visible status. Recipe function. Bar graph function. Flow display function. Alarm list.
Multi language function. True type fonts.
Back panel:
Power supply connector. Fuse 2A. RS-232 connector to PC. USB 2.0 connector to PC.
Inside:
Power supply outputs: 24 Vdc, 12 Vdc, -12 Vdc, 12 Vdc variable.
Panasonic PLC:
High-speed scan of 0.32 µsec. for a basic instruction.
Program capacity of 32 Ksteps, with a sufficient comment area.
Power supply input (100 to 240 V AC).
DC input: 16 (24 V DC).
Relay output: 14.
High-speed counter.
Multi-point PID control.
Digital inputs/outputs and analog inputs/outputs Panasonic modules.
Communication RS232 wire to computer (PC).
Dimensions: 490 x 330 x 310 mm. approx. (19.29 x 12.99 x 12.20 inches approx.). Weight: 30 Kg. approx. (66 pounds approx.).
-PBCC/PLC-SOF. PLC Control Software:
For this particular unit, always included with PLC supply.
The software has been designed using Labview and it follows the unit operation procedure and linked with the Control Interface Box used in the Computer
Controlled Centrifugal Pump Bench (PBCC).

Control Interface Data Software for:


Unit Box Acquisition - Computer Control
Board - Data Acquisition
- Data Management

PLC CONTROL
PLC-SOF.
Control Software

PLC-PI. PLC Module


Practices to be done with PLC-PI:
1.- Control of the particular unit process through the control interface box 13.-PLC different programming standard languages (ladder diagram (LD),
without the computer. structured text (ST), instructions list (IL), sequential function chart (SFC),
2.- Visualization of all the sensors values used in the particular unit process. function block diagram (FBD)).
3.- Calibration of all sensors included in the particular unit process. 14.-New configuration and development of new process.
4.- Hand on of all the actuators involved in the particular unit process. 15.-Hand on an established process.
5.- Realization of different experiments, in automatic way, without having in 16.-To visualize and see the results and to make comparisons with the
front the particular unit. (These experiments can be decided previously). particular unit process.
6.- Simulation of outside actions, in the cases do not exist hardware 17.-Possibility of creating new process in relation with the particular unit.
elements. (Example: test of complementary tanks, complementary 18.-PLC Programming Exercises.
industrialenvironment to the process to be studied, etc). 19.-Own PLC applications in accordance with teacher and student
7.- PLC hardware general use. requirements.
8.- PLC process application for the particular unit.
9.- PLC structure.
10.-PLC inputs and outputs configuration.
11.-PLC configuration possibilities.
12.-PLC program languages.
8 www.edibon.com
Complete Technical Specifications (for optional items)

b) Technical and Vocational Education configuration

8 PBCC/ICAI. Interactive Computer Aided Instruction Software System.


This complete software package consists of an Instructor Software (EDIBON Classroom Manager - ECM-SOF) totally integrated with the
Student Software (EDIBON Student Labsoft - ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and
practical knowledge of the students.
This software is optional and can be used additionally to items (1 to 6).
Instructor Software
- ECM-SOF. EDIBON Classroom Manager (Instructor Software).
ECM-SOF is the application that allows the Instructor to register students,
manage and assign tasks for workgroups, create own content to carry out
Practical Exercises, choose one of the evaluation methods to check the
Student knowledge and monitor the progression related to the planned
tasks for individual students, workgroups, units, etc... so the teacher
can know in real time the level of understanding of any student in the
classroom.

Innovative features: ECM-SOF. EDIBON Classroom


Manager (Instructor Software)
• User Data Base Management. Application Main Screen ECAL. EDIBON Calculations Program Package -
Formula Editor Screen
• Administration and assignment of Workgroup, Task and Training
sessions.
• Creation and Integration of Practical Exercises and Multimedia
Resources.
• Custom Design of Evaluation Methods.
• Creation and assignment of Formulas & Equations.
• Equation System Solver Engine.
• Updatable Contents.
ERS. EDIBON Results & Statistics
• Report generation, User Progression Monitoring and Statistics. Program Package - Student
Scores Histogram ETTE. EDIBON Training Test & Exam Program
Package - Main Screen with Numeric Result
Question
- ESL-SOF. EDIBON Student Labsoft (Student Software).
ESL-SOF is the application addressed to the Students that helps them Student Software
to understand theoretical concepts by means of practical exercises
and to prove their knowledge and progression by performing tests and
calculations in addition to Multimedia Resources. Default planned tasks
and an Open workgroup are provided by EDIBON to allow the students
start working from the first session. Reports and statistics are available
to know their progression at any time, as well as explanations for every
exercise to reinforce the theoretically acquired technical knowledge.

Innovative features:
• Student Log-In & Self-Registration. ESL-SOF. EDIBON Student
LabSoft (Student Software)
• Existing Tasks checking & Monitoring. Application Main Screen
EPE. EDIBON Practical Exercise Program Package
• Default contents & scheduled tasks available to be used from the Main Screen
first session.
• Practical Exercises accomplishment by following the Manual
provided by EDIBON.
• Evaluation Methods to prove your knowledge and progression.
• Test self-correction.
• Calculations computing and plotting.
• Equation System Solver Engine.
• User Monitoring Learning & Printable Reports.
ERS. EDIBON Results & Statistics
• Multimedia-Supported auxiliary resources. Program Package - Question
Explanation
ECAL. EDIBON Calculations Program Package
Main Screen
For more information see ICAI catalogue. Click on the following link:
www.edibon.com/en/files/expansion/ICAI/catalog

9 www.edibon.com
Complete Technical Specifications (for optional items)
9 PBCC/FSS. Faults Simulation System.
Example of some screens
Faults Simulation System (FSS) is a Software package that simulates
several faults in any EDIBON Computer Controlled Unit. It is useful for
Technical and Vocational level.
The “FAULTS” mode consists in causing several faults in the unit
normal operation. The student must find them and solve them.
There are several kinds of faults that can be grouped in the following
sections:
Faults affecting the sensors measurement:
- An incorrect calibration is applied to them.
- Non-linearity.
Faults affecting the actuators:
- Actuators channels interchange at any time during the program
execution.
- Response reduction of an actuator.
Faults in the controls execution:
- Inversion of the performance in ON/OFF controls.
- Reduction or increase of the calculated total response.
- The action of some controls is annulled.
On/off faults:
- Several on/off faults can be included.

For more information see FSS catalogue. Click on the following link:
www.edibon.com/en/files/expansion/FSS/catalog

c) Multipost Expansions options


10 MINI ESN. EDIBON Mini Scada-Net System for being used with
EDIBON Teaching Units.
MINI ESN.
MINI ESN. EDIBON Mini Scada-Net System allows up to 30 students to work EDIBON Mini Scada-Net System
with a Teaching Unit in any laboratory, simultaneously. It is useful for both,
Higher Education and/or Technical and Vocational Education.
The MINI ESN system consists of the adaptation of any EDIBON Computer
Controlled Unit with SCADA integrated in a local network.
1 UNIT= up to 30
This system allows to view/control the unit remotely, from any computer STUDENTS can work
integrated in the local net (in the classroom), through the main computer simultaneously
connected to the unit. Then, the number of possible users who can work with
the same unit is higher than in an usual way of working (usually only one).
Main characteristics:
- It allows up to 30 students to work simultaneously with the EDIBON
Computer Controlled Unit with SCADA, connected in a local net.
Computer Controlled Centrifugal Pump Bench (PBCC)
- Open Control + Multicontrol + Real Time Control + Multi Student
Post.
- Instructor controls and explains to all students at the same time. Software for:
Control - Computer Control
- Any user/student can work doing "real time" control/multicontrol Interface Box - Data Acquisition
and visualisation. - Data Management
- Instructor can see in the computer what any user/student is doing
in the unit. Instructors'
- Continuous communication between the instructor and all the Central Mini Scada-Net
users/students connected. Computer Software
Main advantages:
- It allows an easier and quicker understanding. LOCAL NET FOR 30 STUDENTS
- This system allows you can save time and cost.
- Future expansions with more EDIBON Units. Note: The MINI ESN
system can be used with
any EDIBON computer
controlled unit
For more information see MINI ESN catalogue. Click on the following link:
www.edibon.com/en/files/expansion/MINI-ESN/catalog

11 ESN. EDIBON Scada-Net Systems.


This unit can be integrated, in the future, into a Complete Laboratory with many Units and many Students.
For more information see ESN catalogue. Click on the following link:
www.edibon.com/en/files/expansion/ESN/catalog
10 www.edibon.com
ORDER INFORMATION

Main items (always included in the supply) Optional items (supplied under specific order)
Minimum supply always includes: a) Industrial configuration
1 Unit: PBCC. Computer Controlled Centrifugal Pump 7 PLC. Industrial Control using PLC (it includes PLC-PI Module plus
Bench. PLC-SOF Control Software):
2 PBCC/CIB. Control Interface Box. - PCL-PI. PLC Module.
3 DAB. Data Acquisition Board. - PBCC/PLC-SOF. PLC Control Software.
4 PBCC/CCSOF. Computer Control + Data Acquisition +
Data Management Software. b) Technical and Vocational Education configuration
5 Cables and Accessories, for normal operation. 8 PBCC/ICAI. Interactive Computer Aided Instruction Software
6 Manuals. System.
9 PBCC/FSS. Faults Simulation System.
*IMPORTANT: Under PBCC we always supply all the elements for
immediate running as 1, 2, 3, 4, 5 and 6. c) Multipost Expansions options
10 MINI ESN. EDIBON Mini Scada-Net System for being used with
EDIBON Teaching Units.
11 ESN. EDIBON Scada-Net Systems.

11 www.edibon.com
TENDER SPECIFICATIONS (for main items)

1 PBCC. Unit:
Bench-top unit.
Anodized aluminum frame and panels made of painted steel.
Main metallic elements made of stainless steel.
Diagram in the front panel with distribution of the elements similar to the real one.
Centrifugal pump, computer controlled:
Maximum flow: 80 l/min.
Maximum height (approx.): 20 mwc.
Pump-and-engine-set coupled to an AC motor.
Two regulation valves.
Torque measurement and speed measurement.
Discharge pressure sensor, range: 0 – 2.5 bar.
Admission pressure sensor, range: -1 – 0 bar.
Flow sensor, range: 0 – 150 l/min.
Water transparent tank, capacity: 60 l.
The complete unit includes as well:
Advanced Real-Time SCADA.
Open Control + Multicontrol + Real-Time Control.
Specialized EDIBON Control Software based on LabVIEW.
National Instruments Data Acquisition board (250 KS/s, kilo samples per second).
Calibration exercises, which are included, teach the user how to calibrate a sensor and the importance of checking the accuracy of the sensors before
taking measurements.
Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time.
Capable of doing applied research, real industrial simulation, training courses, etc.
Remote operation and control by the user and remote control for EDIBON technical support, are always included.
Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).
Designed and manufactured under several quality standards.
Optional ICAI software to create, edit and carry out practical exercises, tests, exams, calculations, etc. Apart from monitoring user's knowledge and
progress reached.
This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple
students to simultaneously operate many units in a network.

2 PBCC/CIB. Control Interface Box:


The Control Interface Box is part of the SCADA system.
Control interface box with process diagram in the front panel.
The unit control elements are permanently computer controlled.
Simultaneous visualization in the computer of all parameters involved in the process.
Calibration of all sensors involved in the process.
Real time curves representation about system responses.
All the actuators’ values can be changed at any time from the keyboard allowing the analysis about curves and responses of the whole process.
Shield and filtered signals to avoid external interferences.
Real time computer control with flexibility of modifications from the computer keyboard of the parameters, at any moment during the process.
Real time computer control for parameters involved in the process simultaneously.
Open control allowing modifications, at any moment and in real time, of parameters involved in the process simultaneously.
Three safety levels, one mechanical in the unit, another electronic in the control interface and the third one in the control software.
3 DAB. Data Acquisition Board:
The Data Acquisition board is part of the SCADA system.
PCI Express Data acquisition board (National Instruments) to be placed in a computer slot.
Analog input: Channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KS/s (kilo samples per second).
Analog output: Channels=2. Resolution=16 bits, 1 in 65536.
Digital Input/Output: Channels=24 inputs/outputs.

4 PBCC/CCSOF. Computer Control +Data Acquisition+Data Management Software:


The three softwares are part of the SCADA system.
Compatible with the industry standards.
Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters.
Management, processing, comparison and storage of data.
Sampling velocity up to 250 KS/s (kilo samples per second).
Calibration system for the sensors involved in the process.
It allows the registration of the alarms state and the graphic representation in real time.
Open software, allowing the teacher to modify texts, instructions. Teacher’s and student’s passwords to facilitate the teacher’s control on the student, and
allowing the access to different work levels.
This unit allows the 30 students of the classroom to visualize simultaneously all the results and the manipulation of the unit, during the process, by using
a projector or an electronic whiteboard.
5 Cables and Accessories, for normal operation.
6 Manuals:
This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface and Control Software, Starting-up, Safety, Maintenance,
Calibration & Practices Manuals.

12 www.edibon.com
Tender Specifications (for main items)

Exercises and Practical Possibilities to be done with the Main Items

1.- Demonstration of a centrifugal water pump in operation.


2.- Introduction to pump speed laws.
3.- Obtaining of curves H(Q), N(Q) and Eff%(Q).
4.- Simultaneous representation of H(Q), N(Q) and Eff%(Q).
5.- Obtaining the map of a centrifugal pump.
6.- Adimensional study of magnitudes H *, N * and Q *.
7.- Cavitation test and obtaining of curves NPSHr.
Additional practical possibilities:
8.- Sensors calibration.
Other possibilities to be done with this Unit:
9.- Many students view results simultaneously.
To view all results in real time in the classroom by means of a projector or an electronic whiteboard.
10.- Open Control, Multicontrol and Real Time Control.
This unit allows intrinsically and/or extrinsically to change the span, gains; proportional, integral, derivative parameters; etc, in real time.
11.-The Computer Control System with SCADA allows a real industrial simulation.
12.-This unit is totally safe as uses mechanical, electrical/electronic, and software safety devices.
13.-This unit can be used for doing applied research.
14.-This unit can be used for giving training courses to Industries even to other Technical Education Institutions.
15.-Control of the PBCC unit process through the control interface box without the computer.
16.-Visualization of all the sensors values used in the PBCC unit process.
- By using PLC-PI additional 19 more exercises can be done.
- Several other exercises can be done and designed by the user.

13 www.edibon.com
TENDER SPECIFICATIONS (for optional items)
a) Industrial configuration
7 PLC. Industrial Control using PLC (it includes PLC-PI Module plus PLC-SOF Control Software):
-PLC-PI. PLC Module:
Metallic box.
Circuit diagram in the module front panel.
Digital inputs (X) and Digital outputs (Y) block: 16 Digital inputs. 14 Digital outputs.
Analog inputs block: 16 Analog inputs.
Analog outputs block: 4 Analog outputs.
Touch screen.
Panasonic PLC:
High-speed scan of 0.32 µsec. Program capacity of 32 Ksteps. High-speed counter. Multi-point PID control.
Digital inputs/outputs and analog inputs/outputs Panasonic modules.
-PBCC/PLC-SOF. PLC Control Software:
For this particular unit, always included with PLC supply.
Practices to be done with PLC-PI:
1.- Control of the particular unit process through the control interface box without the computer.
2.- Visualization of all the sensors values used in the particular unit process.
3.- Calibration of all sensors included in the particular unit process.
4.- Hand on of all the actuators involved in the particular unit process.
5.- Realization of different experiments, in automatic way, without having in front the particular unit. (These experiments can be decided previously).
6.- Simulation of outside actions, in the cases do not exist hardware elements. (Example: test of complementary tanks, complementary
industrialenvironment to the process to be studied, etc).
7.- PLC hardware general use.
8.- PLC process application for the particular unit.
9.- PLC structure.
10.-PLC inputs and outputs configuration.
11.-PLC configuration possibilities.
12.-PLC program languages.
13.-PLC different programming standard languages (ladder diagram (LD), structured text (ST), instructions list (IL), sequential function chart (SFC),
function block diagram (FBD)).
14.-New configuration and development of new process.
15.-Hand on an established process.
16.-To visualize and see the results and to make comparisons with the particular unit process.
17.-Possibility of creating new process in relation with the particular unit.
18.-PLC Programming Exercises.
19.-Own PLC applications in accordance with teacher and student requirements.

b) Technical and Vocational Education configuration


8 PBCC/ICAI. Interactive Computer Aided Instruction Software System.
This complete software package consists of an Instructor Software (EDIBON Classroom Manager - ECM-SOF) totally integrated with the Student Software
(EDIBON Student Labsoft - ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge
of the students.
- ECM-SOF. EDIBON Classroom Manager (Instructor Software).
ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out
Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for
individual students, workgroups, units, etc...so the teacher can know in real time the level of understanding of any student in the classroom.
Innovative features:
• User Data Base Management.
• Administration and assignment of Workgroup, Task and Training sessions.
• Creation and Integration of Practical Exercises and Multimedia Resources.
• Custom Design of Evaluation Methods.
• Creation and assignment of Formulas & Equations.
• Equation System Solver Engine.
• Updatable Contents.
• Report generation, User Progression Monitoring and Statistics.
- ESL-SOF. EDIBON Student Labsoft (Student Software).
ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their
knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are
provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time,
as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge.
Innovative features:
• Student Log-In & Self-Registration.
• Existing Tasks checking & Monitoring.
• Default contents & scheduled tasks available to be used from the first session.
• Practical Exercises accomplishment by following the Manual provided by EDIBON.
• Evaluation Methods to prove your knowledge and progression.
• Test self-correction.
• Calculations computing and plotting.
• Equation System Solver Engine.
• User Monitoring Learning & Printable Reports.
• Multimedia-Supported auxiliary resources.

14 www.edibon.com
Tender Specifications (for optional items)

9 PBCC/FSS. Faults Simulation System.


Faults Simulation System (FSS) is a Software package that simulates several faults in any EDIBON Computer Controlled Unit.
The "FAULTS" mode consists in causing several faults in the unit normal operation. The student must find them and solve them.
There are several kinds of faults that can be grouped in the following sections:
Faults affecting the sensors measurement:
- An incorrect calibration is applied to them.
- Non-linearity.
Faults affecting the actuators:
- Actuators channels interchange at any time during the program execution.
- Response reduction of an actuator.
Faults in the controls execution:
- Inversion of the performance in ON/OFF controls.
- Reduction or increase of the calculated total response.
- The action of some controls is annulled.
On/off faults:
- Several on/off faults can be included.

c) Multipost Expansions options


10 MINI ESN. EDIBON Mini Scada-Net System for being used with EDIBON Teaching Units.
MINI ESN. EDIBON Mini Scada-Net System allows up to 30 students to work with a Teaching Unit in any laboratory, simultaneously.
The MINI ESN system consists of the adaptation of any EDIBON Computer Controlled Unit with SCADA integrated in a local network.
This system allows to view/control the unit remotely, from any computer integrated in the local net (in the classroom), through the main computer
connected to the unit.
Main characteristics:
- It allows up to 30 students to work simultaneously with the EDIBON Computer Controlled Unit with SCADA, connected in a local net.
- Open Control + Multicontrol + Real Time Control + Multi Student Post.
- Instructor controls and explains to all students at the same time.
- Any user/student can work doing "real time" control/multicontrol and visualisation.
- Instructor can see in the computer what any user/student is doing in the unit.
- Continuous communication between the instructor and all the users/students connected.
Main advantages:
- It allows an easier and quicker understanding.
- This system allows you can save time and cost.
- Future expansions with more EDIBON Units.
The system basically will consist of:
This system is used with a Computer Controlled Unit.
- Instructor’s computer.
- Students’ computers.
- Local Network.
- Unit-Control Interface adaptation.
- Unit Software adaptation.
- Webcam.
- MINI ESN Software to control the whole system.
- Cables and accessories required for a normal operation.

* Specifications subject to change without previous notice, due to the convenience of improvement of the product.
REPRESENTATIVE:

C/ Julio Cervera, 10-12-14. Móstoles Tecnológico.


28935 MÓSTOLES. (Madrid). ESPAÑA - SPAIN.
Tel.: 34-91-6199363 Fax: 34-91-6198647
E-mail: [email protected] Web: www.edibon.com

Edition: ED01/19
Date: May/2019

15

You might also like