Grounding, Bonding, Safety, RFI by Bill Mader, K8TE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

Grounding, Bonding, Safety, RFI

By Bill Mader, K8TE


W5UR

Longer Lives for You and Your Radio


Safety First—Grounding
Bonding—Keep the Noise Down
RFI—Radio Frequency Interference
Buy the Book by N0AX!
W5UR

Safety First—Grounding
 National Electrical Code—Safety!
Electrical Safety—Current Kills!
 No Help with RFI
 No Antenna Improvement
 Combine with Bonding for Safety!
 Lightning Protection (not Prevention)
W5UR

National Electrical Code


 Helps Lessen Likelihood of This
W5UR

National Electrical Code


 NEC/National Fire Protection Association
 DGYBS (Don’t Get Your Butt Shocked)
 Test Your Outlets
 Lights Dim on Transmit?
Loose Connections Lead to Fires
Wiring Size Too Small
 Don’t Cut/Bypass the Green Wire!
“Here, Hold My Beer. What Could Go Wrong With
This?”
W5UR

NEC on Grounding
 Ground Neutral at Breaker Panel Only
 Tie All Grounds to a Single Point
 Inspect At Least Annually!
 If In Doubt, Get Help
 Local Code Additions Matter
 Avoidance Can Cancel Your Insurance Payout
 Be Careful—120 VAC Can Kill You!
W5UR

Bonding (NOT Grounding)


 Robust, Low Resistance, Short
 Between All Gear
 The Connection Order Matters
 Lightning is a Pulse, Not Direct Current
 Inductance Matters Fast Rise/Decay Times
 Thanks to Jim Brown, K9YC
W5UR

What to Bond? Everything!


• Power Service Entry
• Telephone Entry
• Cable TV Entry
• Antenna Entry
• Operating Desk
• All Ground Rods
• Towers near the Building
• Building’s Structural Steel
• Grounded Metallic Plumbing
W5UR

How to Bond K9YC


 EVERYTHING TOGETHER!
Separate Bonds are Hazardous!
W5UR

How to Bond K9YC


 Bigger is Better
At Least 4 AWG for Towers
At Least 10 AWG for Shack
Steel Conduit (Properly Installed) is OK
 Shorter is Better
Wires are Inductors
Steep Pulses with High Current = High Voltage
Resistance (Ohmic) is Futile in Bonding
W5UR

Why Bond Equipment? K9YC


 Lightning Doesn’t Follow Maps
 Kill Hum, Buzz, RFI
 Shields Carry Leakage Currents
 Shields Act as Antennas (TX & RX)
 Pin One Problems Cause Noise
Poor Engineering Construction Practices
Shield Not Bonded to Metal Case
at Ingress and/or Egress
Coupling Inside Gear Creates/Allows for RFI
W5UR

Pin 1 Example
W5UR

Rigs with Pin 1 Problem


W5UR
W5UR
W5UR

RFI—Radio Frequency Interference


 Switching Mode Power Supplies
Cell Phone Chargers
Laptops/Desktops/Tablets
USB Hubs
Our Own 12VDC Power Supplies!
Station Layout (W8JI.com)
 All the New “Stuff” Your Neighbors Buy
 “If it ain’t heavy, it’s RFI’ing” K8TE
W5UR

In House Search
 Identify & Document RFI by Band
 Connect Rig to a Battery (Should be “Standard”)
 Turn Off Main Breaker
 Check All Bands Previously Noted
 Some RFI Disappears?
 Enable One Breaker At-a-Time
 Locate and Discard/Replace the Culprits
W5UR

Neighborhood Search
 Rotate Your Beam
 Document Frequencies/Time/Spectrum
 Use Portable Radio; Short Wave is Best
 Search for Loudest Signals
 Good Luck from Here
 Common Additional Sources
 Grow Lamps (Mary Jane?)
 Solar Systems
 Variable Speed HVAC
 LED Lighting—Research Replacements
W5UR

RFI Remediation
 Move to the Boondocks
 Buy Spouse an LED TV (K8TE)
 Separate RX Antenna (Magnetic Loop)
 Noise Cancelling System
DX Engineering NCC2
 Move Beyond the Boondocks in NM
 RX Noise Blanker
 Use CW (Narrow the Bandpass)
 Use JT-65/FT-8 (“Below” Noise Capable)
W5UR

40m Noise at K8TE on 80m OCF


W5UR

40m Noise at K8TE on 80m R8


W5UR

Grounding and Bonding for Us


 Ward Silver, N0AX
 Engineer
 Long Time ARRL
Editor
 Fun, Amiable Guy!
 Buy the Book
W5UR

What Did I Tell You?


Safety First—Grounding
Bonding—Keep the Noise Down
RFI—Radio Frequency Interference
Buy the Book!
W5UR

DCHF Highlights
 Three Days of 50+ Concurrent
Technical & Operational Sessions
21-23 September Register Now!
 HF University 2.0 All Day Friday
 EmComm College All Day Friday
 AMSAT Academy All Day Friday
 VE License Prep & Testing
 SKYWARN Training Sunday Morning
 QSL-card Checking for ARRL Operating Awards
 Build-a-thon With Rex Harper, W1REX
W5UR

DCHF Highlights
 Two Breakfast Banquets
 Evening ARRL Awards Banquet
 Friday Evening Mixer and Auction
 All With Separate Door Prizes
 Raffles With Exceptional Prizes
 (2) IC-7300’s and KX2 (probably) & More
 Manufacturers and Commercial Vendors
 STEM-Student High-Altitude Balloon Launch
En Route to CubeSat!
W5UR

DCHF Highlights
 Indoor Flea Market
 Friday/Saturday Outdoor Tailgate Market
 Consider Volunteering—Free Admission/Prize
 The Venue:
 Isleta Casino & Resort Convention Center
10 Minutes South of the Albuquerque Airport
 Food Station for Lunch
 Early Admission Only $12.50! $15.00 at the door
 Sign-up for Monthly E-Mail Updates
 https://www.dukecityhamfest.org/
W5UR

Questions
No “Dumb” Questions
Maybe a Dumb Answer
W5UR

References
 http://www.nfpa.org/nec
 http://www.midwestcomforthomes.com/examples-
bad-dangerous-electrical-wiring-systems/
 http://audiosystemsgroup.com/publish.htm
 https://www.dxengineering.com/parts/dxe-rf-pro-1b
 https://www.dxengineering.com/parts/dxe-ncc-2
 https://www.arrl.org/shop/Grounding-and-Bonding-
for-the-Radio-Amateur/
 http://w8ji.com/house_ground_layouts.htm
W5UR

Pin 1 Fixes
 Rewire Connector—Shield to Metal Chassis
 Bond Connector to Chassis, NOT PCB
 Use Common Mode Choking
Snap-on Ferrites
Wind Cables around Ferrite Cores
 Bonding Gear Together and to Shack Ground
Reduces Noise Generated by Gear
Eliminates Shock Hazards
 Bond Multiple Outlet Boxes Together
 Use Larger (12/10 AGW) to Breaker Panel

You might also like