Eaton Industrial Special Process List (SPL)
Eaton Industrial Special Process List (SPL)
Eaton Industrial Special Process List (SPL)
Processor Address City ST/Country Zip Attention Phone Status Approval Date Aluminum Finishing Plating/ Steel Finishing Non-Ferrous Heat Treat Steel Heat Treat Inspection Welding & Brazing Miscellaneous
ASTM-E-1444 (MPI) Abrasive Clean TAP-PS-510; Shot Peening MIL-S-
Absolute Technologies 4890 East La Palma Ave Anaheim CA 92807 (714) 692-6570 A 05/25/11 13165, AMS-S-13165,and AMS 2430; NADCAP
Accredited for MPI & Shot Peen
Anodize (TYPE I, II, III) MIL-STD-8625, AMS-2468, AMS QQ-N-290, AMS 2403 AMS 2410M AMS 2412 AMS-QQ-C-
ACP Aerospace 6 Joo Koon Circle Singapore Singapore 629037 65 6863 8318 A 05/15/12 69, 70, 71, 72. CHEMICAL CONVERSION MIL-DTL- 320M AMS 2460 AMS 2406
5541
MIL-STD-6866 (FPI) W/ ETCH AND ATC SOP 52- NADCAP Accredited for NonDestructive Testing
Eastlake OH 44095 (440) 954-9404 A 09/11/13 08-0000-00-017 And ASTM-E-1417 (MPI) ASTM-E-
Advanced Quality Group Inc. 36600 Lakeland Blvd.
1444 & ATC SPEC. 03-10562, Pre-FPI etch TAP-
PS-498
Anodize (TYPE I, II, III) MIL-STD-8625, AMS-2469, Electroless Nickel AMS 2404, MIL-C-26074. Silver QQ-S-365, Nadcap Approved Anodize & Chemical Conversion;
Aero-Safe Processing Inc. 1360 Commerce Pkwy Fort Erie ON L2A 5N1 (905) 994-8848 CA 08/10/09 70, 71, 72. CHEMICAL CONVERSION MIL-DTL- ASTM B 700, AMS 2412. Copper MIL-C-14550, AMS 2418. not for GE. Euclid did not perform a SP audit at
5541 supplier
Anodize (TYPE I, II, III) MIL-STD-8625, AMS-2469, Nadcap Approved Anodize & Chemical Conversion;
Aerospace Metal Finishing 71 Proctor Rd. Schomberg ON LOG 1T0 (905) 939-8830 CA 08/10/09 70, 71, 72. CHEMICAL CONVERSION MIL-DTL- not for GE. Euclid did not perform a SP audit at
5541 supplier
MIL-H-6088 (ALUMINUM) SOLUTION NADCAP Accredited Aluminum Heat Treating.
979 Seville Rd. P.O. BOX & PRECIPITATION HEAT TREAT.
Alfe Heat Treating Inc. Wadsworth OH 44281 (330) 336-0211 A 11/15/13
749 AMS-H-6088, AMS 2770, 2771, 2772.
MIL-A-8625 (TYPE II, III CLASS 1 & 2) AMS-2471 & QQ-P-35 (PASSIVATION TYPE 1 THRU IV) MIL-S-5002 MIL-L-46010 (SOLID FILM LUBRICANT TYPES I
AMS-2472 MIL-DTL-5541 (CHEMICAL (PASSIVATION ONLY) ASTM A967 ASTM A380, AMS 2700 & ll) TAP-PS-775 (SOLID FILM) AS 5272 Dry Film.
CONVERSION CLASS 1A, III MIL-A-63576, AMS NADCAP Accredited for Chemical Processing and for
2482, Ty2.) P.T.F.E.IMPREGNATION ON ALUM. & Painting & Dry Film Coatings.
ALUM. ALLOYS, TYPE I & III AMS-2468 AMS-2469
Allen Aircraft Products, Inc. 4879 Newton Falls Road Ravenna OH 44266-9673 (330) 296-9621 x 3442 A 07/26/13
MIL-C-5541 (CHROMATE CONV. (CLASS 1 & 3) QQ-P-35 (TYPES II, VI, VII,VIII) PASSIVATION MIL-S-5002 MIL-STD-6866 (FPI W/O ETCH) ASTM-E-1417 Welding MIL-STD-2219 NADCAP Accredited for NonDestructive Testing
(FPI) ASTM-E-1444 (MPI) MIL-STD-453 and 1261
Alloyweld Inspection Co. 796 Maple Lane Bensenville IL 60106-1585 (630) 595-2145 A 09/24/09 RADIOGRAPHY Mil-Std-2154 Type I & II
Ultrasonics Radiograph (ASTM E 1742, ASTM E
2033) Pre-FPI Etch TAP-PS-498
MIL-H-6875(STEEL & MIL-B-7883 (BRAZING) "TAP-PS specifications supplier only approved to
CRES) *TAP-PS-716 *TAP- AMS-2664, AMS-2665 Perform initial Hardening for Machinability of Rough
PS-764 *TAP-PS-669 *TAP- (SILVER BRAZING) Machined Blanks" NADCAP Approved for Materials
American Brazing 4428 Hamann Parkway Willoughby OH 44094 (440) 946-5900 A 01/03/13 PS-564 *TAP-PS-920 AMS- AMS 2675 (NICKEL) Testing Laboratories, Hardness Testing for Heat Treat,
H-6875, AMS 2759, 2769, ALLOY BRAZING) Heat Treating and Brazing.
2774, 5629, 5663, 6875
Anodize Type II & III, MIL-A-8625, AMS-2468, 2471, Passivation QQ-P-35 TYPE II, VI, VII ASTM 967 AMS-QQ-P-35, Note: No NADCAP Accreditation.
2472. Chromate Conversion Coat MIL-DTL-5541. AMS 2700
Anodizing Specialists, Inc. 7547 Tyler Blvd. Mentor OH 44060-4869 (440) 951-0257 A 01/02/13
Anodize Type I, II & III, MIL-A-8625, MIL-A-8625. Electroless Nickel Plate ASTM B663 TYPE I - IV, AMS QQ-N-290, NADCAP Approved for Chemical Processing
Applied Total Control Treatment No. 6 Marsiling Lane Blk B Singapore Singapore 739145 65 9647 5994 A 05/10/12
Conversion Coat MIL-DTL-5541 ASTM B700-97, AMS 2404
Fluorescent Particle Inspection, ASTM-E-1417. NADCAP Accredited for NonDestructive Testing
Magnetic Particle Inspection ASTM-E-1444. Facility, Magnetic Particle and Fluorescent Particle
5305 John Lucas Drive
Applus RTD Burlington ON L7L 6A8 (905) 331-8810 CA 08/20/09 Inspection without etch. Not approved for use on GE
Unit-1
programs. Previously names Stavely Services.
MIL-A-8625(SULFURICACID, TYPE IAND TYPE QQ-C-320, MIL-C-23422, AMS 2406 (CHROME), AMS2404 MIL-A-8625 (ASTM B117, SALT SPRAY; ASTM MIL-A-8625 (ASTM B117, SALT SPRAY; ASTM
II)ANODIZE AMS-2468, AMS- (ELECTROLESSNICKEL), QQ-N-290, MIL-P-27418 (NICKEL B244,- THICKNESS; TABER ABRASION; B244,- THICKNESS; TABER ABRASION;
2469(HARDCOAT)AMS 2470(CHROMICACID),AMS SULFAMATE),QQ-P-35 MIL-S-5002 STEEL COATING WEIGHT) AMS 2468 (ASTM B 137, COATING WEIGHT) AMS 2468 (ASTM B 137,
2471(SULFURICACIT.UNDYED), PARTS)(PASSIVATIONAMS 2438 (CHROME-DENSE) COATING WEIGHT ASTM B244; THICKNESS) COATING WEIGHT ASTM B244; THICKNESS)
AMS2472(SULFURICACID, DYED).AMS AMS2469 (ASTMB117, SALT SPRY; ASTM AMS2469 (ASTMB117, SALT SPRY; ASTM B137,
2482IMPREGNATION, Chromic Conversion MIL-DTL- B137, COATING WEIGHT; ASTM B244, COATING WEIGHT; ASTM B244, THICKNESS;
5541, MIL-C-5541. THICKNESS; ASTM B487; ASTM B487;
MICROSCOPICALEXAMINATION)AMS 2470 MICROSCOPICALEXAMINATION)AMS 2470
(ASTM B117, SALT SPRAY; ASTM B137, (ASTM B117, SALT SPRAY; ASTM B137,
COATING WEIGHT) AMS 2471 (ASTM B117, COATING WEIGHT) AMS 2471 (ASTM B117,
SALT SPRAY; ATM B137, COATING WEIGHT) SALT SPRAY; ATM B137, COATING WEIGHT)
AMS 2472 (ASTM B117, SALT SPRAY; ATM AMS 2472 (ASTM B117, SALT SPRAY; ATM
B137, COATING WEIGHT) MIL-C-5541 (ASTM B137, COATING WEIGHT) MIL-C-5541 (ASTM
B117, SALT SPRAY; QQ-C-320 (ASTM B487, B117, SALT SPRAY; QQ-C-320 (ASTM B487,
MICROSCOPICALEXAMINATION)ASTM B578, MICROSCOPICALEXAMINATION)ASTM B578,
Argo-Tech Corporation - Plating 23555 Euclid Ave. Cleveland OH 44117 (216) 692-5456 A MICROHARDNESSMIL-STD- 1312/5, MICROHARDNESSMIL-STD- 1312/5,
FASTENERS) AMS 2404 (ASTMB117,SALT FASTENERS) AMS 2404 (ASTMB117,SALT
SPRAY: ASTM B487, SPRAY: ASTM B487,
MICROSCOPICALEXAMINATION)ASTM E290, MICROSCOPICALEXAMINATION)ASTM E290,
BND TEST) QQ-N-290 (ASTM B487, BND TEST) QQ-N-290 (ASTM B487,
MICROSCOPICALEXAMINATION)ASTM B504; MICROSCOPICALEXAMINATION)ASTM B504;
COULOMETRIC MEASUREMENT;ASTM B529; COULOMETRIC MEASUREMENT;ASTM B529;
EDDY CURRENT)QQ-P-35 (ASTMB117, SALT EDDY CURRENT)QQ-P-35 (ASTMB117, SALT
SPRAY) AMS 2438 (ASTM B117, SALT SPRAY; SPRAY) AMS 2438 (ASTM B117, SALT SPRAY;
ASTM B487; ASTM B487;
MICROSCOPICALEXAMINATION;ASTM B504; MICROSCOPICALEXAMINATION;ASTM B504;
COULOMETRICMEASUREMENT;TABER COULOMETRICMEASUREMENT;TABER
ABRASION; MECHANICAL HYDROGEN ABRASION; MECHANICAL HYDROGEN
EMBRITTLEMENTTESTING; EMBRITTLEMENTTESTING;
MICROHARDNESS) MICROHARDNESS)
Anodize Type II & III, MIL-A 8625, AMS 2469, Type Electroless Nickel, AMS 2404, Mil-C-26074. Passivation, ASTM NADCAP Approved for Chemical Processing
AVTEC Finishing Systems 9101 Science Center Dr. New Hope MN 55428 Scott Peek (763) 489-7048 A 07/24/13 III Hardcoat, Chromate Conversion; Mil-C-5541, MIL- A967, A380, AMS 2700, QQ-P-35.
DTL-5541
810 Bloomfield Ave.P.O. MIL-H-6088 (ALUMINUM)AMS-H- MIL-STD 6866 &ASTM-E-1417(FPI) FPI-NOTAPPROVED. FORPROCESSES
Atlantic Casting Clifton NJ 7012-1116 (973) 779-2450 A 06/16/06
BOX 4016 6088AMS 2771 REQ.ETCH
Anodize Types I, II & III, MIL-A-8625, AMS 2469, Electroless Nickel, AMS 2404, Mil-C-26074, ASTM B733. Removed Removed Magnetic Particle Inspection, ASTM E 1444, Removed original notes and added NADCAP
2470, 2471, 2472. Chromic Conversion MIL-DTL-5541. Passivation, ASTM A967, A380, AMS 2700, QQ-P-35. Chromium Fluorescent Particle Inspection, ASTM-E-1417 Accredited for Painting & Dry Film Coatings,
Barry Avenue Plating 2210 Barry Ave. Los Angeles CA 90064 Kathy Alaliz (310) 478-0078 A 06/13/12 AMS 2460, QQ-C-320. Silver AMS 2410, 2411, 2412, ASTM B700, (W/ETCH). Chemical Processing, NonDestructive Testing.
QQ-S-365. Passivation ASTM A967, A380, AMS 2700, QQ-P-35
Nital Etch (Pre-Penetrant) Aluminum Heat Treating, AMS 2771, Steel Heat Treat, MIL-H- MIL-STD-6866 &ASTM-E-1417 (FPI) MIL-STD- *Only Approved to Perform Initial Hardening for
AMS-H-6088, MIL-H-6088. 6875, AMS-H-6875, AMS 453 (RADIOGRAPHY) Machinability of Rough Machined Blanks. NADCAP
Willoughby OH 44094 (440) 946-5300 A 08/12/11 2759, 2769, 2774. TAP-PS- Approval for Steel and Aluminum Heat Treating,
Bescast 4600 E. 355th St.
564*, 669*, 764* 920. Hardness Testing for Heat Treating, Etch Processes,
Fusion Welding and NonDestructive Testing
(Penetrant, Radiography)
MIL-H-6088, AMS 2770,2772, 2750 Weber Metals subcontracted supplier for salt bath heat
Bodycote 7474 Garden Grove Blvd. Westminster CA 92683 Marcia Bell (714) 893-6561 A 06/19/13 treatment on F119 forged block mater NADCAP &
AS9100 accredited.
Hot Isostatic Processing (HIP), TAP-MS-642 NADCAP Accredited
Bodycote Hot Isostactic Processing 443 East High Street London OH 43140 [email protected] (740) 852-4955 A 07/22/08
Densal (I and II).
Updated: 11/18/14
11/18/2014 EATON INDUSTRIAL SPECIAL PROCESS LIST (SPL)
Release Date: 11/18/2014
#
Processor Address City ST/Country Zip Attention Phone Status Approval Date Aluminum Finishing Plating/ Steel Finishing Non-Ferrous Heat Treat Steel Heat Treat Inspection Welding & Brazing Miscellaneous
Removed Steel Heat Treating, MIL-H- *Only Approved to Perform Initial Hardening for
6875, AMS-H-6875, 2759, Machinability of Rough Machined Blanks (Was
Bodycote Thermal Processing 3370 Benedict Way Huntington Park CA 90255 [email protected] (323) 583-1231 A 03/11/13 2769, 2774, 5629. *TAP-PS- Industrial Steel Treating) NADCAP Accredited for
564*TAP-PS-669*TAP-PS- Heat Treating and Hardness Testing.
764.
AMS-2665(SILVER
Brite Brazing 5476 Lake Court Cleveland OH 44144 (216) 881-4532 A 09/10/13
BRAZING)
Ion Vapor Depostion (IVD) per AMS 2427, AS9100
Cametoid Technologies 150 Colonial Road Manchester CT 6040 Tom Scarduzio (860) 646-4667 A 10/09/13
Accredited
Aluminum Heat Treating, AMS 2771, Removed Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Fusion Weld NADCAP Accredited for Materials Test Laboratories,
AMS-H-6088, MIL-H-6088. (W/ETCH). Radiography, MIL-STD-453, and their evaluation. Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Metallographic Evaluation of Welds, Metallography
Carley Foundry 8301 Coral Sea St. N.E. Blaine MN 55449 Andy Brostrom (763) 780-5123 A 08/19/11 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Aluminum Heat Treating, AMS 2771, Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Fusion Weld NADCAP Accredited for Materials Test Laboratories,
AMS-H-6088, MIL-H-6088. (W/ETCH). Radiography, MIL-STD-453, and their evaluation. Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Metallographic Evaluation of Welds, Metallography
Cera-Met 2175 Avenue "C" Bethlehem PA 18017 Steve Huber (610) 266-0270 A 07/24/12 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Anodize (TYPE I, II, III) MIL-STD-8625, AMS-2469, Silver Plate QQ-S-365, ASTMB700. Chrome Plate AMS 2406, NADCAP Approved for Chemical Processing
70, 71, 72. CHEMICAL CONVERSION MIL-DTL- ASTM B650, QQ-C-320. Electroless Nickel AMS 2404, MIL-C-
5541 26074.
C.J. Saporito Plating 3119 S. Austin Ave. Cicero IL 60650 Jeff Logan (708) 222-5300 A 07/21/06
Concast Metal Products Co. 131 Myoma Rd. Mars PA 16046 (412) 538-4000, 1-800 626-7071 A + TAP-MS-285LEADED BRONZE
Aluminum Heat Treat AMS 2771 Fluorescent Penetrant Inspection, ASTM-E-1417 AWS D17.1, TAP-MS-642 NADCAP Accredited for Materials Test Laboratories,
(W/ETCH). Radiography, MIL-STD-453, Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Sand Castings TAP-MS-638 Metallographic Evaluation of Welds, Metallography
Consolidated Precision Product 4200 West Valley Blvd. Pomona CA 91769 Mike Adams (909) 595-2252 A 09/19/13 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Aluminum Heat Treat AMS 2771 Fluorescent Penetrant Inspection, ASTM-E-1417 AWS D17.1, TAP-MS-642 NADCAP Accredited for Materials Test Laboratories,
(W/ETCH). Radiography, MIL-STD-453, Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Investment Castings TAP-MS-638 Metallographic Evaluation of Welds, Metallography
Consolidated Precision Product 705 Industrial Ave. Port Hueneme CA 93041 Kinjal Patel (805) 488-6451 A 09/17/13 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Aluminum Heat Treat AMS 2771 Fluorescent Penetrant Inspection, ASTM-E-1417 AWS D17.1, TAP-MS-642 NADCAP Accredited for Materials Test Laboratories,
(W/ETCH). Radiography ASTM -E-1742. Sand & Chemical Analsis, Specimen Heat Treating,
Permanent Mold Castings TAP-MS-638 Metallographic Evaluation of Welds, Metallography
Consolidated Precision Product 8333 Wilcox Ave Cudahy CA 90201 Victor Zepeda (323) 773-2363 A 09/18/13 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Crucible Industries LLC 575 State Fair Blvd. Syracuse NY 13209-1560 (315) 487-4111 A + CPM Tool Steel producer
Bronze Plate AMS 2429, TAP-PS-809, Chrome Plate AMS 2406; NADCAP Accredited for Chemical Processing, Dry
DCI Aerotech, Inc. 7515 Lyndon Ave. Detroit MI 48238 (313) 341-9478 A 08/29/13 QQ-C-320, Silver Plate AMS 2410, AMS 2412, AMS 2418 Film Coatings MIL-L46010, MIL-DTL-53030.
Processor Address City ST/Country Zip Attention Phone Status Approval Date Aluminum Finishing Plating/ Steel Finishing Non-Ferrous Heat Treat Steel Heat Treat Inspection Welding & Brazing Miscellaneous
CHROMIC CONVERSIONCOATING TESTING, STAINLESSPASSIVATIONTESTING,BATCH RADIOGRAPHIC (NAVSEA 250-1500-1, PROCESSCONTROL, TAP-PS-902BEARING NADCAP Approved for Materials Test Laboratories,
ACID ETCHTESTING, ANODIZE TESTING, PLATING(CUSTOMERSPEC.)TESTING,PROCESSEVALUATIO MIL-STD-453C, MIL-STD- FAILUREANALYSIS,MATERIALSAPPLICATIO PREPARATION. Chemical Analsis, Corrosion, Specimen Heat Treating,
PROCESS EVALUATION N/TROUBLE SHOOTING 2132,GENERAL ELECTRIC, SNECMA) NPAINT ANDSOLVENTFORMULATIONAND Metallographic Evaluation of Welds, Metallography
METALLOGRAPHY(FULL ANALYSIS,SALT SPRAYAND and Microindentation Hardness, Mechanical Testing.
RANGETEST/ANALYSISOF RAW HUMIDITYTESTING.
ANDFINISH METALSAS PER
CUSTOMERREQUIREMENTS)OFF-
SITE ANDINSITU ANALYSIS
AVAILABLE.SCANNING
ELECTRONMICROSCOPE(FAILURE
ANALYSIS,ELEMENTALIDENTIFICAT
IONLIGHT ELEMENT
Eaton Aerospace Laboratories 23555 Euclid Ave. Cleveland OH 44117 (216) 692-5406 A ANALYSIS,FERROUS, NON-
FERROUS, COMPOSITE
ANDCERAMIC
MATERIALSANALYSIS ASPER
CUSTOMERREQUIREMENTS)
CHEMICAL ANALYTICALSERVICES
(METALS, SOLIDS, LIQUIDS
ANDGASEOUS ANALYSIS),MULTI-
SERVICE, FULLRANGE CHEMICAL
TESTING ASPER
CUSTOMERREQUEST
ANDSPECIFICATIONSIVE
ANALYSISGEAE CODE ANPWA 14
Electronic Balancing Co. 660 East "D" Street Wilmington CA 90744 (310) 830-4995 A + Precision Balancing
Anodize Types I, II & III per MIL-A-8625, AMS 2468, Chrome Plate QQ-C-320, AMS-2406, 2438, 2460. Cadmium Plate Magnetic Particle ASTM E 1444, MIL-STD-6866. Dry Film Coatings MIL-L-46010, MIL-L-8937, MIL-
2469, 2470, 2471, 2472. Chromate conversion Class 1 QQ-P-416, AMS 2400, AMS 2401, 2419. Nickel Plate QQ-N-290, Penetrant ASTM-E-1417 W/Etch. L-46147, MIL-L-23398, TAP-PS-775 (SOLID
& 3, MIL-C-5541. Ion Vapor Deposit (IVD) AMS AMS 2403, 2424. Passivation QQ-P-35, ASTM A380, A967, AMS FILM), AS 5272 TYPE I & II. NADCAP Approved
Santa Ana CA 92705 (714) 546-9842 A 03/15/12 2427, MIL-C-83488. 2700. Copper Plate MIL-C-14550, AMS 2418. Electroless Nickel for Chemical Processing, NonDestructive Testing
Embee Plating 2136 S. Hathaway Ave.
Plate MIL-C-26074, AMS 2404, ASTM B733. Silver Plate ASTM Magnetic Particle and Penetrant with Etch. Shot
B700, AMS 2410, 2411, 2412, QQ-S-365. Shot Peening MIL-S- Peening
13165, AMS-S-13165, AMS 2430.
Electrical, Sound, Vibration, Endurace Testing services. INDEPENDENT TESTING SERVICES DYNAMIC
Environ Laboratories, Inc. 9725 Grand Ave. South Minneapolis MN 55431-2621 (952) 888-7795 A +
VIBRATION ENDURANCE CYCLING, ETC.
**MIL-H-6088AMENDMENT 1, AMS-H- **MIL-H-6875 (STEEL & *Approved to Perform Initial Hardening for
6088, AMS 2770 CRES)CLASS A,B,C. Machinability of Rough Machined Blanks, and
(ALUMINUM)PRECIPITATIONHARDE PRECIPITATIONHARDE Hardening and temper-conditioning. Not Approved For
NING ONLY NING OFCLASS D TAP- Diffusion Nitriding.**Limited Note: Euclid Heat
Euclid Heat Treat 1408 E. 222ND. ST. Cleveland OH 44117 (216) 481-8444 A 11/26/13 PS-716 *TAP-PS-548 Treat "Not" NADCAP Accredited.
*TAP-PS-596 *TAP-PS-
564 *TAP-PS-669 *TAP-PS-
764 *TAP-PS-920 **AMS-
H-6875 TAP-PS-6875
Anodizing AMS 2469, 2470, 2471, 2472 Conversion Passivation QQ-P-35, ASTM A 967, A 380. Magnetic Particle ASTM E 1444, MIL-STD-6866. NADCAP Approved for Chemical Processing,
Future Weld 3518 E. Wood Street Phoenix AZ 85040 (602) 437-2426 A 03/09/12 Coatings AMS 2473, 2474, MIL-C-5541, MIL-D-5541. Penetrant ASTM-E-1417 W/Etch. NonDestructive Testing Magnetic Particle and
Penetrant with Etch.
MIL-H-6875 AMS-H-6875 NADCAP Accredited for Materials Testing
(STEEL & CRESCLASS A, Laboratories, Metallography and Microhardness. Steel
B, C, D)**TAP-PS-548 Heat Treating and Hardness Testing.
General Metal Heat Treating, Inc. 941 Addison Rd. Cleveland OH 44103-1609 Deborah Dougherty (216) 391-0886 A 07/24/14 **TAP-PS-596 *TAP-PS- *Only Approved to Perform Initial Hardening for
564 *TAP-PS-669 *TAP-PS- Machinability to Rough Machined Blanks. **Approved
764 *TAP-PS-920 TAP-PS- for hardening and temper conditioning(less diffusion
942 nitriding)
Passivation QQ-P-35, ASTM A 967, A 380, AMS 2700. Magnetic Particle Inspection ASTM-E-1444. NADCAP and AS9100 Accredited for Chemical
H & S Inspection Service 422 Oliver Dr. Troy MI 48084 1850 Front Street (248) 362-8141 A 07/23/13 Penetrant Inspection ASTM-E-1417 No Etch. Processing Passivation. NonDestructive Testing
Magnetic Particle and Penetrant with Etch.
Performs PVD (Physical Vapor Deposition) coatings
on cutting & forminig tools. Development project with
Munroe Falls OH 44262 Jim Haag (330) 686-2136 CA 02/25/14 processor to TZB (Titanium-Zirconium Di-Boride)
Hardcoating Technologies 103 S. Main Street
coat gear motor compenents to extend service life on
high wear areas.
Braze per MIL-B-7883 Heat Treat per MIL-H- Brazing MIL-B-7883, NADCAP Accredited for Brazing (Vacuum &
6875, AMS-H-6875, 2759, AMS-2662, 2664, 2665, Atmosphere). Steel Heat Treating and Hardness
HI Techmetal Group- 2774, 2759, 2801. *TAP-PS- 2670, 2675, 2678. Testing. *Only Approved to Perform Initial Hardening
34800 Lakeland Blvd. Eastlake OH 44095 Removed (440) 946-2280 A 12/13/12
HTG HITech Aero 564 *TAP-PS-669 *TAP-PS- for Machinability of Rough Machined Blanks.
764 *TAP-PS-920 *TAP-PS- **Approved for hardening and temper conditioning
596. (less diffusion nitriding)
Removed MIL-H-6088*AMS-H-6088*AMS-2772* MIL-H-6875 AMS-H-6875 *Aging only**Only approved toperform initial
Wickliffe OH 44092 R. Palermo (440) 943-4555 A 12/13/12 (TAP-PS-564, 548, 596, heattreating per listedTAP-PS specifications.
Hi Tecmetal Group-Nettleton 28910 Lakeland Blvd
669, 691, 716 and 764**)
Updated: 11/18/14
11/18/2014 EATON INDUSTRIAL SPECIAL PROCESS LIST (SPL)
Release Date: 11/18/2014
#
Processor Address City ST/Country Zip Attention Phone Status Approval Date Aluminum Finishing Plating/ Steel Finishing Non-Ferrous Heat Treat Steel Heat Treat Inspection Welding & Brazing Miscellaneous
Anodize MIL-A-8625 types I, II & III, AMS 2469, Silver Plate AMS 2410,2411, 2412 and QQ-S-365. Nickle Plate NADCAP Accredited
2470, 2471 AMS 2403,2424 & QQ-N-290. Electroless Nickel plate AMS 2404,
Hixson Metal Finishing 829 Production Place Newport Beach CA 92663 Debbie Sykes (949) 645-4800 A 11/19/13
2405 & MIL-C-26074. Passivation QQ-P-35, ASMT A380. Dry
Film Coatings AC 7108/1, AS 5272, MIL-L-46010
Anodize MIL-A-8625 Types I, II & III, AMS 24669, Cadmium Plate QQ-P-416, AMS 2400, 2401. Chromium Plate NADCAP Accredited for Chemical Processing, Dry
2470, 2471, 2472 Conversion Coat MIL-C-5541, DTL- QQ-C-320, ASTM B 650, AMS 2406, 2460. Nickel Plate QQ-N- Film Coatings MIL-L46010, MIL-L-81329, 23398,
Hohman Plating & Mfg 814 Hillrose Ave. Dayton OH 45404 (937) 228-2191 A 05/08/09 5541, AMS 2473. 290, AMS 2403, 2423, 2424. Electroless Nickel Plate MIL-C- AMS 2515, 2525, 2526.DTL-53030.
26074, AMS 2404, 2405.Passivation QQ-P-35, ASTM A967, A380,
AMS 2700.
Hooven Heat Treating, Inc. 11 Old Right Rd. Ipswich MA 1938 (800) 346-5852 A + Was Metal Photo - photo nameplates
NADCAP Approved for Materials Test Laboratories,
Chemical Analsis, Specimen Heat Treating,
Metallographic Evaluation of Welds, Metallography
Howmet Aluminum Georgetown
93 Mountainview Rd. N. Georgetown Ontario L7G4J6 (905) 877-6936 A 10/05/09 and Microindentation Hardness, Mechanical Testing,
Casting
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Chromium Plating AMS 2406 2438 2460 QQ-320 MIL-STD- NADCAP Approved for Chemical Processing
1501, Nickel Plating AMS 2403 2423 2424, Electroless Nickel
Induplate 1 Greystone Dr. N. Providence RI 02911 Juan Rosario (401) 231-5770 A 09/27/12
Plating AMS 2404. Abrasive Blast TAP-PS-510.
Inspection Engineering LLC 30903 Viking Parkway Westlake OH 44145 Dennis Kostelnik (440) 892-9277 A 08/24/12 CALIBRATION CMM & gage Calibration house
Joining Technologies 17 Connecticut South Drive East Granby CT 6026 Jeff Whittaker (860) 784-1964 CA 10/08/13 MIL-W-8604, AWS D17.1 NADCAP and AS9100 Accredited
K.P. Bronze 16 Allaura Blvd. Aurora ON L4G 3S5 800 572-0660 A + TAP-MS-285 LEADED BRONZE MATERIAL
QQ-P-416 CADMIUM PLATECLASS 1,2, &3. TYPE 1 & 2 AMS- Note: Not NADCAP Accredited
K.B. Plating Co. 3685 E. 78TH ST. Cleveland OH 44105 (216) 341-1115 A 08/30/13 2400 AMS-2401 QQ- C-320 (Chrome plate class 2) AMS-2406 &
MIL-C-23422, MIL-STD-1501
Anodize AMS 2468, 2469, 2470, 2471, 2472, 2482, PASSIVATION QQ-P-35, ASTM A 380, A 967, AMS 2700 Magnetic Particle ASTM-E-1444, Fluorescent NADCAP Accredited Chemical Processing,
MIL-A-8625 Acid Etch TAP-PS-498 Chromate Cadmium Plate AMS 2400, 2401 ASTM B600, QQ-P-416 Particle ASTM-E-1417 W/Etch, Radiography MIL- NonDestructive Testing, MPI, FPI, Radiography,
Magnetic Inspection Lab 1401 Greenleaf Ave. Elk Grove Village IL 60007-5522 (847) 437-4488 A 08/07/14
Conversion Coatings MIL-C-13924, -5541, -DTL-5541 STD-453 , TAP-PS-498 Welding & Dry Film applications.
Maini Precision Products Pvt Ltd Bommsandra Estate Bangalore India Gautam Maini (91) 80 40724700 A 01/25/10 FPI ASTM-E-1417 MPI ASTM-E-1444 NADCAP ACCREDITED
MIL-STD-1252 TAP-PS-402 NADCAP Accredited Welding / Brazing, Rotational
Manufacturing Technology Inc. 1702 W. Washington St. South Bend IN 46628 (574) 233-9490 A +
Friction / Inertia Welding.
Metal Improvement Co. 1652 E. Highland Rd. Twinsburg OH 44087 (330) 425-1490 A 05/15/14 Shot Peening MIL-S-13165, AMS-S-13165, AMS 2430. NADCAP Accredited Shot Peening
Metal Improvement Co. 30100 Cypress Rd. Romulas MI 48174 (734) 728-8600 A 07/24/13 Shot Peening MIL-S-13165, AMS-S-13165, AMS 2430. NADCAP Accredited Shot Peening
Shot Peening MIL-S-13165, AMS-S-13165, AMS 2430, 2431, NADCAP Accredited Shot Peening
Metal Improvement Co. 103 S. 41ST. AVE. Phoenix AZ 85009-4627 Cecilia Owen (602) 278-2811 A 10/30/13
2432, ASTME B851
Micro Laboratories, Inc. 7158 Industrial Park Blvd. Mentor OH 44060 (440) 918-0001 A + Instrument calibration, NDT supply
Magnetic Particle ASTM-E-1444, Fluorescent NADCAP Accredited for NonDestructive Testing,
Milan Tool Corp 8989 Brookpark Rd Cleveland OH 44129-6890 (216) 661-1078 A 11/11/11
Particle ASTM-E-1417 W/Etch Magnetic particle and Penetrant W/Etch
Heat Treat per MIL-H-6088, AMS-H- NADCAP Accredited for Aluminum Heat Treating
Newton Heat Treating 19235 E. Walnut Dr. City of Industry CA 91748-1438 (626) 964-6528 A 03/14/12
6088, 2770, 2771, 2772. and Hardness Testing
Heat Treat per MIL-H-6088, AMS-H- Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for Materials Test Laboratories,
6088, 2771 (W/ETCH). Radiography, MIL-STD-453, Mechanical Testing, Aluminum Heat Treating and
NFT Technology Co. Ltd. No 88 Weisuei Rd Gangshan Township Taiwan 80026 886 2 6606 6622 A 03/13/14
ASTM -E-1742. Casting AMS 2175 Hardness Testing. NonDestructive Testing (Penetrant
W/Etch, Radiography).
Fluorescent Particle Inspection, ASTM-E-1417 Note: In-house Penetrant Facility is operated by
Norbert Industries 38111 Commerce Dr. Sterling Heights MI 48312 (586) 977-9200 A 12/17/11 without Etch. contract with XRI Testing. NADCAP Accredited for
NonDestructive Testing (Penetrant without Etch).
Steel & Cres Heat NADCAP Accredited for Materials Testing
Treating MIL-H-6875, Laboratories, Metallography and Microhardness. Steel
AMS-H-6875, AMS 2759, Heat Treating and Hardness Testing.
O&W Heat Treat Inc. 1 Bidwell Rd. South Windsor CT 06074 (860) 528-9239 A 08/16/12 2769. * (TAP-PS-564, TAP- *Only Approved to Perform Initial Hardening for
PS-669, TAP-PS-764, TAP- Machinability to Rough Machined Blanks. **Approved
PS-920) for hardening and temper conditioning(less diffusion
nitriding)
Removed Heat Treat per MIL-H-6088, AMS-H- Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for Materials Test Laboratories,
6088, 2771 (W/ETCH). Radiography, MIL-STD-453, Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Metallographic Evaluation of Welds, Metallography
Ohio Aluminum Industries Inc. 4840 Warner Rd. Garfield Heights OH 44125 (216) 641-8865 A 07/16/11 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Anodize Types I,II & III - MIL-A-8625, AMS 2468, 2469, 2470, Nadcap Accredited for Chemical Processing, Painting
2471, 2482. Silver Plate - AMS-A-2410, 2411, 2412 and QQ-S-365, and Dry film coatings
ASTM B700, Nickle Plate - AMS 2403, 2424 & QQ-N-290,
Electroless Nickel Plate - AMS 2404, 2405 & MIL-C-26074,
PAS Technologies 1021 N. 22nd Ave. Phoenix AZ 85009 (602) 744-2631 A 10/30/13
Chrome Plate - AMS-QQ-320, AMS2406, 2407, 2438, Passivation -
QQ-P-35, ASTM A380, A967, AMS2700, MIL-S-5002, Dry Film
Coatings - AC 7108/1, AS 5272, MIL-L-46010
Jorge Alonzo
TAP-PS-498 (Aluminum Etch) Heat Treat per MIL-H-6088, AMS-H- Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for Materials Test Laboratories,
6088, 2771 (W/ETCH). Radiography, MIL-STD-453, Mechanical Testing, Aluminum Heat Treating and
PCC Structurals, Inc. 24 Granite St. Tilton NH 03276-0188 (603) 286-4301 A 07/27/06 ASTM -E-1742. Hardness Testing. NonDestructive Testing (Penetrant
W/Etch, Radiography). Name change was Wyman-
Gordon
Heat Treat per AMS-H-6088 MIL-H- Steel Heat Treating, MIL- Removed NADCAP Accredited Materials Testing Laboratories
6088 AMS-2770 AMS-2771 , AMS Q-A- H-6875, AMS-H-6875, Metallography and Microhardness, Aluminum and
Phoenix Heating Treating 2405 West Mohave Phoenix AZ 85009 Mike Hushek (602) 258-7751 A 10/29/13 200 2759, 2769, 2774, *TAP-PS- Steel Heat Treating
564*TAP-PS-669*TAP-PS-
764.
Removed Heat Treat per AMS-H-6088 MIL-H- Steel Heat Treating MIL-H- Removed NADCAP Accredited for Aluminum and Steel Heat
Praxair Surface Technology 1366 Tolland Turnpike Manchester CT 6042 Bruce Pederson (860) 533-4816 A 08/15/12 6088 AMS-2770 AMS-2771 6875, AMS-H-6875, 2759, Treating and Hardness Testing.
2769
7F #13 Lane 35, JIHU RD AMS 2771 X Ray ASTM E 1417 NADCAP Accredited.
Precision Engineered Products Tapiei Taiwan 114 R.O.C. 114 (886-2) 66066622 A 10/07/09
Nei-Hu
LASER WELDING Note: Not NADCAP Accredited.
965 Capstone Drive, Suite
Precision Joining Technologies, Inc. Miamisburg OH 45342 (937) 865-4051 A + (Approved to TAP-PS-
109
940)
ASTM-E-1417 (FPI) ASTM-E-1742 NADCAP Accredited for NonDestructive Testing
Precision Metalsmith Inc. 1081 East 200th St. Euclid OH 44117-1132 C. Cross (216) 481-8900 A 08/03/11 (Radiographics)MIL-STD-2175 Castings
(withoutMaterial Testing)
Progress Services Inc. 13948 Progress Parkway North Royalton OH 44113 (440) 237-1811 A + Pre-Penetrant Etch TAP-PS-498 Removed NADCAP Accredited for Pre-Penetrant etch
Fluorescent Particle Inspection, ASTM-E-1417. NADCAP Accredited for a NonDestructive Testing
Remmele Engineering 17701 198th Ave Big Lake MN 55309 (763) 263-2636 A 08/17/11 Facility, Fluorescent Particle inspection without etch.
Aluminum Acid Etch Heat Treat per MIL-H-6088, AMS-H- Removed Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for Materials Test Laboratories,
6088, 2771 (W/ETCH). Radiography, MIL-STD-453, Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Metallographic Evaluation of Welds, Metallography
Ross Aluminun Foundries 815 Oak Ave Sydney OH 45365-0609 (937) 492-4134 A 11/10/11 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Updated: 11/18/14
11/18/2014 EATON INDUSTRIAL SPECIAL PROCESS LIST (SPL)
Release Date: 11/18/2014
#
Processor Address City ST/Country Zip Attention Phone Status Approval Date Aluminum Finishing Plating/ Steel Finishing Non-Ferrous Heat Treat Steel Heat Treat Inspection Welding & Brazing Miscellaneous
Anodize MIL-A-8625, AMS 2468, 2469, 2470, 2471, Passivation QQ-P-35, AMS QQ-P-35. Chrome plate QQ-C-320, NADCAP Accredited for Chemical Processing.
2472, Chromate Conversion Coatings MIL-C-5541, - AMS-QQ-C-320, 2406. Copper plate MIL-C-14550, AMS 2418.
DTL-5541, AMS 2473. Cadmium plate AMS QQ-P-416, 2400. Silver plate QQ-S-365,
AMS 2410,211,2412. Electroless Nickel plate MIL-C-26074, AMS
2404, 2405.
Selfridge Plating Co. 42081 Irwin Rd. Harrison Twp. MI 48045 Jim Dodge (586) 469-3141 A 08/16/13
Anodize: MIL-A-8625 Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for NonDestructive Testing,
Southwest United Canada 8201 Keele Street Unit 9/12 Concord L4K 1Z4 (905) 456-3245 A 01/24/11 W/Etch. Magnetic Particle Inspection ASTM-E- Magnetic particle and Penetrant W/Etch.
1444. Shot Peening manual & automated.
Chem Film MIL-DIL-5541 Gold Plate MIL-G-45204, ASTM B488, AMS 2422. Electroless NADCAP Accredited for Chemical Processing. MPC
Nickel MIL-C-26074, AMS 2404, ASTM B733. Nickel Plating QQ- source for gold plate on electronic feed thru (F22)
N-290. Silver Plating QQ-S-365, ASTM B700. Passivation ASTM
Specialized Plating Inc. 15 Wardhill Avenue Haverhill MA 1835 Paul Kelly (978) 373-8030 A 09/27/12
A380, A967, QQ-P-35, AMS 2700.
TAP-PS-510 (Abrasive clean) Heat Treat and Nitride NADCAP Accredited for Materials Testing
per TAP-PS-764, 716, 548, Laboratories, Metallography and Microhardness. Steel
564, 596, 669, 691. *TAP- Heat Treating and Gas Nitriding. Only approved
PS-920 (INITIAL & FINAL special process source for gas nitride per various TAP-
HEAT TREAT PER PS specifications.
Specialty Steel Treating 34501 Commerce Rd. Fraser MI 48026-1692 Rick Carroll (810) 293-5355 A 07/24/13 PARAGRAPHS 4.2.31 And
4.2.3.2 Only). MIL-H-6875,
AMS-H-6875, 2759, 2769,
2774..
Anodize AMS 2468, 2469, 2471, 2472, MIL-A-8625. Removed Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for Chemical Processing and
Acid Etch TAP-PS-498. Chromate Conversion W/Etch NonDestructive Testing. MPC anodize source on F22
Stable Plating Co. 1150 E. Edna Place Covina CA 91724 Steve Crest (626) 339-9091 A 03/07/13
Coating MIL-C-13924, -5541, -DTL-5541. controllers
Superfinishers Inc. 380 East Highland Rd. Macedonia OH 44056 (330) 467-2125 A + Superfinish per ATC specification 03-10099 Superfinish ATC Spec. 03-10099
Supreme Gear Co. 17430 Malyn Blvd Fraser MI 48026 Ed Ebenhoeh (586) 294-7625 A 07/27/12 Magnetic Partical Inspection ASTM E 1444 AS9100, ISO9001:2008, NADCAP accredited for MPI
Fluorescent Particle Inspection, ASTM-E-1417. NADCAP Accredited for NonDestructive Testing
Magnetic Particle Inspection ASTM-E-1444. Facility, Magnetic Particle and Fluorescent Particle
Talon Test Lab 5002 S.40th Street Phoenix AZ 85040 (602) 454-2500 A 03/06/12
Film Radiography ASTM-E-1742. Inspection without etch. Film Radiography.
Aluminum Castings MIL-STD-2175 Aluminum Heat Treat MIL-H-6088, Fluorescent Particle Inspection, ASTM-E-1417 NADCAP Accredited for Materials Test Laboratories,
AMS-H-6088, 2771. (W/ETCH). Radiography, MIL-STD-453, Chemical Analsis, Specimen Heat Treating,
ASTM -E-1742. Metallographic Evaluation of Welds, Metallography
Tec-Cast Inc. 440 Meadow Lane Carlstadt NJ 7072 (201) 935-3885 A 03/20/07 and Microindentation Hardness, Mechanical Testing,
NonDestructive Testing (Penetrant, Radiography),
Fusion Welding and Aluminum Heat Treating.
Complete Mechanical Testing, Hardness, Fusion weld and welder NADCAP Accredited for Materials Test Laboratories-
Metallography, Microhardness and Chemical evaluations. Mechanical Testing, Hardness, Metallography,
Tensile Testing 4520 Willow Parkway Cleveland OH 44125 (216) 641-3290 A +
Testing. Corrosion, Chemical Testing and evaluation of welds.
Removed Aluminum Heat Treat MIL-H-6088, Steel Heat Treating MIL-H- NADCAP Accredited for Materials Testing
AMS-H-6088, 2770, 2771, 2772. 6875, AMS-H-6875, 2759, Laboratories-Metallography, Microhardness and
Therelek Engineers Private Ltd. 70-71 3rd. Phase, Peenya Bangalore India 560058 T. Radhakrishnan 91-080-28395101 A 10/13/09
2769, 2774. Hardness Testing. Aluminum and Steel Heat Treating.
Anodize types I & II, MIL-A-8625, AMS 2470, 2471. NADCAP Accredited for Chemical Processing.
Wolkerstorfer Co. 348 First Street SW New Brighton MN 55112 (651) 636-0720 A 08/18/11 Chromate Conversion Coat MIL-C-5541, DTL-5541.