Fire Safety Commercial PDF
Fire Safety Commercial PDF
Fire Safety Commercial PDF
COMMERCIAL
BUILDINGS
1
WHAT IS FIRE?
• Fire is the process of burning. It is infact a chemical
reaction initiated by presence of heat energy in
which a substance combines with oxygen in the air
and the process is accompanied by emission of
energy in the form of heat, light and sound.
Therefore, three elements are essential for
combustion i.e.
• Acombustible matter i.e fuel
• Oxygen
2 • Source of heat, Spark flame etc.
FIRE SAFETY AS PER AS NBC
• With the help of FIRE PROTECTION ACT of
1997 and National Fire Protection
Association ,a part was added to NATIONAL
BUILDING CODE
• THE SECTION IS TERMED AS PART 4 (FIRE AND
LIFE SAFETY )
3 • THIS PART INVOLVES CERTAIN SET OF NORMS
FOR FIRE SAFETY OF ALL TYPES OF BUILDINGS.
FIRE SAFETY AS PER AS NBC
Group ‘A’ - Residential And commercial: Lodgings,
Dwellings Dormitories, Flats, Hotels.
Group ‘B’ - Educational : School, Colleges,
Recreations
Group ‘C’ - Institutional : Hospitals, Homes for aged,
Orphanages, Jails, Mental Hospital, reformatories.
Group ‘D’ - Assembly : Theatres, Drama Hall, Assembly
4
Halls, Auditorium, Exhibition, Restaurants, Place of workship,
Terminal etc.
FIRE SAFETY AS PER AS NBC
Group ‘E’ - Business : Office, Labs, Computer
Installations
Group ‘F’ - Mercantile : Shops, Stores, Market.
Group ‘G’ - Industrial : Assembly Plants, Labs,
Pumping stations, Refineries,Saw mills.
Group ‘H’ - Storage : All types of storages, Sheds,
5
trucks & marine terminals, Garages, Hangars, Stables.
Group ‘J’ - Hazardous : Used to store highly combustible or
explosive materials which may produce poisonous fumes
or explosions or toxic etc.
WIDTH OF ROAD
Sections:- As per section 4.6 (a) of part 3 &
7.4.1 (a) of part IV of N.B.C.
The road which abuts a High rise commercial building to
be constructed shall be more then 12 meter width. The
road should be hard surfaced to carry a minimum
weight of 18,000 Kgs, the maximum weight of a Fire Engine.
6
ENTRANCE WIDTH AND HEIGHT OF CLEARANCE.
7
SET BACKS AND OPEN SPACES
8
CAR PARKING IN SETBACKS
9
CAR PARKING
10
STAIRCASES
13
LIFTS
15
THE REFUGE AREA
17
SERVICE DUCTS
As per appendix D 1.9 part IV of N.B.C. all the services ducts, if
provided, should have to be enclosed by walls of at least 2 hour
fire resistance & should have to be sealed at every alternate floor
with non-combustible materials having at least 2 hour fire
resistance. The sealing at floor level is to prevent travel of smoke &
fire to the upper floors through the ducts.
18
FIRE FIGHTING SYSTEM
WET RISERS AND DOWN COMMER SYSTEM
• Wet riser : It is a vertical pipeline (dia. depends on the floor area
of the building) connected to a bottom tank(underground
water tank).
• Down Commer : It is a vertical pipeline (dia. depends on the
floor area of the building
• Dry riser : It is a vertical pipe which is always kept dry to avoid
20
the freezing of water.
• Hydrant : It is a horizontal pipe line with outlet of 63 mm. dia.
connected to underground water tank.
WET RISERS
• Wet riser cum down commer or only down commer system shall
be provided for commercial building.
• For commercial building only wet-riser system shall be
provided.
• For hotels wet-riser cum down commer both the systems shall
be provided.
• Diameter of riser will be 150mm for all the buildings.
• For each 1000m2 floor area or it’s part one riser shall be
provided.
21
• At every landing twin outlet each of 63mm dia.shall be
provided (one should be connected to hose reel & another
should be to hose & branch).
WET RISERS
• Length of hose should be shall that it should reach at the last
point of floor area.
• Minimum two courtyard hydrants shall be provided (courtyard
hydrant will be an extention to riser).
• Hose reel hose of 12mm dia. shall be provided from landing
valve to wet-riser at each floor.
• A separate fire service inlet shall be provided at the ground
floor.
22
• Location of wet-riser shall be preferable as near to staircase.
WET RISERS
23
FIRE HYDRANTS AND HOSE REELS
23
WATER TANK
• Underground water storage tank varies from 50,000 ltrs. to
250,000 ltrs. Depending on the type & occupancy of the
buildings.
• The capacity of terrace level water storage tank varies from
10,000 ltrs. to 20,000 ltrs. Depending on the type & occupancy of
the building.
• Above mentioned water tank capacity is for 1 riser. If the
number of risers will be more than 1, than quantity of water shall
24 be increased in that proportionate.
• In addition to this if automatic sprinkler, drenchers are provided
for special risk then this will be additional quantity of water
WATER TANK
25
FIRE ALARM SYSTEM
1. Manually operated Electrical fire alarm system
• Depending on the occupancy, M.O.E.F.A. system or automatic
operated system shall be provided in the building.
• Every building more than 15m in height shall provide both I.e.
M.O.E.F.A &A.F.A.
• Commercial buildings between15m & 24m in height may be
exempted from installation of automatic fire alarm system if
local fire brigade is well equipped to face the emergency up to
26 24m.
• One has to manually operate the glass in M.O.E.F.A.S.
FIRE ALARM SYSTEM
27
FIRE DETECTION SYSTEM
Section: As per section 7.9 of part IV of NBC. (8 of
Appendix A)
• Different types of detectors are provided as per the risk involved
in the area.
• Zones are made as per the risk or as per the floor.
• 2way communication system to be provided which will help to
contact from ground floor to specific floor or vice-versa.
• Mike on every floor has to be provided.
28
• On mike instructions can be given as per situation
• Manual call points, automatic detector & public address system
shall be inter linked.
SPRINKLER SYSTEM
Section: As per section 7.10.7 of part IV of NCB.
• Sprinkler system is a must for basement parking & other risk
areas where large quantities of combustible materials are
stored.
• Each sprinkler should cover 6.96m2 area.
• Normally a separate sprinkler should be provided for a separate
car.
• Sprinklers may connect to main water tank & pump, but
29 capacity of the tank & pump shall be increased in that
proportionate.
• The capacity of water tank shall be calculated on the basis of
sprinklers.
SPRINKLER SYSTEM
30
FIRE ESCAPE
As per section 8.2.5 of part IV of NBC, the escape route should be
marked with a sign board on the corridor & passage to guide
evacuation. Normally, the escape route sign board must be
written in luminous paint for easy identification. This is to guide
every occupant of the building who is bound to panic in the event
of accident.
31
PUBLIC ADDRESS SYSTEN
As per appendix D.5 of part IV of NBC, every high rise building
should have a public address system with 2 way communication
to conduct evacuation in a systematic manner & to communicate
any messages to occupants on every floor from the control room
PROVISION OF HELIPAD
Section: As per D 10(Appendix D) of part IV
of N.B.C.
32
For High rise commercial buildings above 60 m in height provision
for Helipad should be made.
Fire Drills & Fire Orders
Section: As per section D 8 (Appendix D) of part
IV of N.B.C.
Fire Safety Plan: It`s very important to have a fire safety plan to
prevent & extinguish any fire in the building with details action to
be taken by each occupant. Telephone nos. of all emergence
services much be indicated in the plan.
33
Fire Drills & Fire Orders
34
Fire Drills & Fire Orders
.