) BUNDLE 2 R2 #5 OR 2 R9 #5
THRIE BEAM FOR SIZE & LOCATION, SEE ADJACENT TO EACH END OF
OR W-BEAM 2 ~ 10' STEEL JUNCTION BOX TABLE JUNCTION BOX (TYP.)
END OF BRIDGE OR WALL 7 CURB LINE
GUARDRAIL CONDUITS
2 ~ STAINLESS STEEL
TS LT MOUNTING TABS (TOP & BOT.)
8" x 8" x 18" JUNCTION BOX 7
2'-0"
JUNCTION BOX SIZED PLAN OR COPPER PIPE DRAIN
PER ELECTRICAL PLANS.
LABEL JUNCTION BOX LIDS CONDUITS & J-BOX IN TRAFFIC BARRIER
AS SHOWN (TYP.)
A
NOTE TO DESIGNERS
MODIFY THE FOLLOWING TO MATCH PROJECT REQUIREMENTS:
1. BARRIER END SECTION. ¢ J-BOX & BARRIER PANEL ¢ J-BOX & BARRIER PANEL SECTION A
2. REMOVE GUARDRAIL IF NOT CONNECTED TO BRIDGE ITEM.
3. CONDUIT ALIGNMENT 200'-0" MAX.
¾"
STEEL CONDUIT,
INCLUDING TS LT TS LT
Last revised on :
ELBOWS AND
SWEEPS
BONDING JUMPER
1" TIES ~ SPACE @ 2½" MAX. 1"
BLOCKOUT FOR STEEL CONDUIT TO PVC ADAPTOR IN TOP OF BRIDGE DECK 2"ø CONDUIT PIPES OR CONDUIT EXPANSION FITTING
CONDUITS STATIONARY FORM BARRIER WHERE AT CURB LINE SIZE CONDUIT PER CONDUIT FITTING - (TYPE AX FOR MOVEMENT OF ± 2")
PVC PIPE INSTALLED IN BARRIER 6 WIRING SCHEDULE
NOTES:
09/25/2020
1" TIES @ 2½" 1" JOINT THAT COINCIDES WITH THE RETAINING WALL EXPANSION JOINT.
¾" POLYSTYRENE FOAM. WRAP
1 1½ TIMES AROUND CONDUIT
4 LABEL JUNCTION BOX COVER IN ACCORDANCE WITH STANDARD SPECIFICATION SECTION 9-29.2(4).
AND CONDUIT FITTING
ADJACENT JUNCTION BOXES ARE SHOWN CENTERED BETWEEN ADJACENT DUMMY JOINTS. IF THE
DISTANCE BETWEEN ADJACENT DUMMY JOINTS IS 16'-0" OR GREATER, PLACE ADJACENT
¾"
JUNCTION BOXES SYMMETRICALLY ON EITHER SIDE OF THE CENTER OF ONE DUMMY PANEL WHILE
3" MIN., 6" MAX. (CONDUIT AND
MAINTAINING 8'-0" MINIMUM BETWEEN CENTER LINES OF THE JUNCTION BOXES.
SOIL
CONDUIT FITTING - TYPE DX FOR DEFLECTION OF 30° AND ¾" MOVEMENT. CONDUIT FITTING - TYPE DX FOR DEFLECTION OF 30° AND ¾" MOVEMENT. 8 3'-0" LONG EXPANDED POLYSTYRENE SLEEVE AROUND CONDUIT. DUCT TAPE SEAMS AND ENDS TO
2 3 SEAL AND PREVENT CONCRETE FROM BONDING WITH FITTING AND CONDUIT.