0% found this document useful (0 votes)
74 views2 pages

Equipment: MS Software: Procedure To Adjust The Step Range of Cmyd Key Correction

1. This document provides instructions to adjust the step range of the CMYD key correction for different screens on an MS software. 2. It describes adjusting parameters in the I2GUISettings - Global.ini file to change the correction amount and maximum values for color and density. 3. The parameters control the detail of the correction by adjusting the correction amount per step and the maximum adjustment range displayed.

Uploaded by

radisa69q
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views2 pages

Equipment: MS Software: Procedure To Adjust The Step Range of Cmyd Key Correction

1. This document provides instructions to adjust the step range of the CMYD key correction for different screens on an MS software. 2. It describes adjusting parameters in the I2GUISettings - Global.ini file to change the correction amount and maximum values for color and density. 3. The parameters control the detail of the correction by adjusting the correction amount per step and the maximum adjustment range displayed.

Uploaded by

radisa69q
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

No.

ED1014
September 2009

Equipment : MS Software

PROCEDURE TO ADJUST THE STEP RANGE OF CMYD KEY


Subject :
CORRECTION

Improvement & Part No. Errata & Technical Product Info. & Modification Field Equip.
Countermeasures Additions Information Specifications Control Countermeasure
UN1 [ ] UN2 [ ] UN3 [ √ ] UN4 [ ] No. No.

<Contents>
The procedure to adjust the step range of the CMYD key correction for 6-frame view and order
screen/1-frame view and order screen/Enlarged view and order screen is described below.

<Version in question>
MS01 Basic Software V.2.5.5

<Adjustment procedure>

1. File
C:\Fes\Datafiles\I2GUISettings - Global.ini

2. Items to be adjusted
Change the parameters described in bold face of I2GUISettings - Global.ini (No. 1 - No. 4) below. After
changing, restart the system. (Note: Do not change other items than those in bold face.)

[I2GUISettings]
colorMultiplier=8 …No. 1
colorMax=20 … No. 2
Example
densityMultiplier=15 … No. 3 Regular Shops with regular Professional
densityMax=34 … No. 4 shops and pro services lab
contrastMultiplier=5
No. 1 8 4 2
contrastMax=10
saturationMultiplier=1 No. 2 20 30 36
saturationMax=9 No. 3 15 8 4
sharpenMultiplier=50
No. 4 34 50 60
sharpenMax=10
hlSDMultiplier=2
hlSDMax=25

Factory Modifications : From Serial No.: Completion Date :

Field Countermeasures : [ ] Individually, with Charge [ ] Individually, Free of Charge [ ] All Free of Charge
Order Basis Automatic Distribution
Part Preparation : [ ] [ ] Available : [ ] Being Prepared by: [ ]
After Order Received by:

1
<Description of items to be adjusted>
No. Key name Default Description Range Restriction
1 colorMultiplier 8 Correction amount of CMY per 1 step. 1 - 512
The smaller the value is, the more The result of
detailed the correction is. multiplying value of No.
2 colorMax 20 The maximum value that CMY can be 1 - 99 1 by value of No. 2
set on the GUI. should be 512 or less.
The minimum value is the negative
value.
(Ex. If this value is 20, the setting can
be done between 20 to -20.)

3 densityMultiplier 15 Correction amount of D per 1 step. 1 - 512


The smaller the value is, the more The result of
detailed the correction is. multiplying value of No.
4 densityMax 34 The maximum value that D can be set 1 - 99 3 by value of No. 4
on the GUI. should be 512 or less.
The minimum value is the negative
value.
(Ex. If this value is 34, the setting can
be done between 34 to -34.)