MP 30 Digital Weighing Indicator: AC DC AC

This document summarizes the specifications of the MP 30 Digital Weighing Indicator. It has a 16-bit resolution and can take up to 20 readings per second. It has options for analog outputs, serial interfaces, and setpoint outputs. It is IP65 sealed and has a manual tare function. Key specifications include its power supply, display, measurement input range and accuracy, analog and serial outputs, and environmental operating conditions.

Uploaded by

kevin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
361 views2 pages

MP 30 Digital Weighing Indicator: AC DC AC

This document summarizes the specifications of the MP 30 Digital Weighing Indicator. It has a 16-bit resolution and can take up to 20 readings per second. It has options for analog outputs, serial interfaces, and setpoint outputs. It is IP65 sealed and has a manual tare function. Key specifications include its power supply, display, measurement input range and accuracy, analog and serial outputs, and environmental operating conditions.

Uploaded by

kevin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MP 30

Digital Weighing Indicator

– 16 bit resolution and up to


20 readings/sec.
– Supply voltage: 85 - 250 VAC
50/60 Hz or 11-36 VDC /24 VAC (option)
– 3 digital control inputs
– Analog output (option):
0/4-20 mA or 0-10 VDC
– Serial interfaces (option):
RS 232 or RS 485
– 2 setpoint outputs (option)
– IP 65 sealed front panel
– Manual tare

Technical Data Digital control inputs Environmental conditions


3 configurable user inputs (TTL) Operating temperature range: 0 to 50°C
Protection class Input voltage: max. 30 VDC (0 to 45°C with all three plug-in cards
Housing: IP 20 Sink or source (aktiv |passiv) selectable installed)
Panel mounted: IP 65 Sink: high Vin < 0.7 VDC, low Vin > 2.5 VDC Storage temperature range: -40 to 60°C
Source: high Vin > 2.5 VDC, low Vin < 0.7 VDC Humidity: 0 to 85 % max. non-condensing
Power supply
85 - 250 VAC 50/60 Hz Update rates A/D converter
11 - 36 VDC or 24 VAC (Option) Step response: 200 msec. max. to Resolution: 16 bit
Max. power consumption: 15 VA within 99 % of final readout value A/D Conversion rate: 20 readings/sec.
(digital filter and internal zero
Display correction disabled) Manual tare
Bright 5-digit LED display, 14 mm 700 msec. max. (digital filter disabled, Configurable via front keys
Status symbols: brutto|gross, net, tare internal zero correction enabled)
Setpoint indication

Keypad Measuring input


5 keys for operation, calibration and
configuration Input Range Accuracy Accuracy Impedance max. Continous Resolution
(18 to 28°C) (0 to 50°C) Overload
Load cell excitation ±24 mVDC 0,02 % of 0,07 % of 100 MO 30 V 1 µV
Jumper selectable: reading +3 µV reading +4 µV
5 VDC at 65 mA max. +/-2 %
10 VDC at 125 mA max. +/-2 % ±240 mVDC 0,02 % of 0,07 % of 100 MO 30 V 10 µV
Max. four load cells of 350 O reading +30 µV reading +40 µV
Temperatur coefficient: 20 ppm/K max.
Analog output MP 30/20 Setpoint output MP 30/11 Low frequency noise rejection
2 analogue outputs with: Type: 4 FORM-A relays Normal mode: > 60 dB at 50 or
0/4-20 mA or 0-10 VDC Total current: 3 A at 120/240 VAC or 28 VDC 60 Hz +/-1 %, digital filter off
Isolation to sensor & user input commons Common mode: > 100 dB, DC to 120 Hz
Accuracy: 0.17 % of FS (18 to 28°C) Serial communications (w.r.t. earth)
Resolution: 1/3500 RS 232 (MP 30/31)
Compliance: 10VDC: 10 KO load min. or RS 485 (MP 30/32) Custom linearization
20 mA: 500 O load max. Isolation to sensor & user input commons: Data point pairs: selectable from 2 to 16
Update time: max. 200 msec. filter and zero Settings: Databits: 7/8, Display range: -19.999 to 99.999
correction disabled Baudrate: 300 - 19,200, Decimal point: 0 to 0.0000
Gross |net selectable Parity: no |odd |even
Bus address: selectable 0 - 99,
Setpoint output MP 30/10 max. 32 devices per line (RS 485)
Type: 2 FORM-C relays Distance:
Isolation to sensor & user input commons RS 232: up to 15 m
Total current: 5A at 120/240 VAC or 28 VDC RS 485: up to 1200 m
Life expectancy: 100 K cycles min.
at full load rating.
Gross |net selectable

1.950
(49.5) 1.750 1.750
(44.5) (44.5)

0.100 4.1
3.800
(2.5) (104.1) 3.60 (91.4)
(96.5)

Dimensions in inches (mm)

Order information

Type Description Order number


MP 30/00 Digital Indicator 85 to 250 VAC 9408 800 30001
MP 30/01 Digital Indicator 11 to 36 VAC/DC 9408 800 30011
MP 30/10 Dual Relay Output for MP 30/0x 9408 800 30101
MP 30/11 Quad Relay Output for MP 30/0x 9408 800 30111
MP 30/20 Analog Output for MP 30/0x 9408 800 30201
MP 30/31 RS 232 Interface for MP 30/0x 9408 800 30311
MP 30/32 RS 485 Interface for MP 30/0x 9408 800 30321

Sartorius Mechatronics T & H GmbH


Meiendorfer Strasse 205
22145 Hamburg, Germany
Specifications subject to change
without notice. Phone +49.40.67960.303
Printed in Germany.
n/sart · C
Fax +49.40.67960.383
Publication No.: HMP2002-e10101
Order No.: 9498 708 30001 [email protected]
Version 09.2010 www.sartorius-mechatronics.com