Manual 450 Mps

1) This document provides important safety notices for installers of an automation system. It lists 27 safety regulations to follow including warnings about packaging materials, following instructions, intended use of the product, and more. 2) Mechanical elements must comply with certain standards and installation must meet safety standards C+E. Safety devices must protect areas with mechanical hazards. 3) The automation is equipped with anti-crush safety but further safety devices must be installed. Qualified personnel must perform repairs and adjustments. Only original spare parts should be used.

Uploaded by

Christian Bayle
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
747 views10 pages

Manual 450 Mps

1) This document provides important safety notices for installers of an automation system. It lists 27 safety regulations to follow including warnings about packaging materials, following instructions, intended use of the product, and more. 2) Mechanical elements must comply with certain standards and installation must meet safety standards C+E. Safety devices must protect areas with mechanical hazards. 3) The automation is equipped with anti-crush safety but further safety devices must be installed. Qualified personnel must perform repairs and adjustments. Only original spare parts should be used.

Uploaded by

Christian Bayle
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

per la natura for nature pour la nature ist umweltfreundlich para la naturaleza

carta riciclata 100% recycled paper 100% papier recyclé 100% 100% Altpapier 100% papel reciclado

A ZIE
N C

D
A
ER

C E R TI
ME

F
IC T
ATA

UNI EN ISO 9001-085


450 MPS
ENGLISH

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS


1) WARNING! FAAC strongly recommends to follow these instructions literally for the safety of persons. Improper
installation or misuse of the product will cause very serious damages to persons.
2) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.
3) Read the instructions carefully before installing the product.
4) Keep these instructions for future reference.
5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly
set forth will affect the reliability of the product and/or could be source of hazard.
6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which
the automation system is destined to.
7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.
8) Mechanical constructive elements must comply with UNI8612, CEN pr EN 12604 and CEN pr EN 12605 standards.
Countries outside the EC shall follow the regulations above besides their national normative references in order to
offer the utmost safety.
9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,
or for any deformation of the gates which may occur during use.
10) Installation must comply with UNI8612, CEN pr EN 12453 and CEN pr EN 12635.
The degree of safety of the automation must be C+E.
11) Before carrying out any operations, turn off the system’s main switch.
12) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.
Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.
13) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.
14) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green
wire of the operator.
15) The automation is fitted with an anti-crush safety system that is a torque control device. In any case, further safety
devices shall be installed.
16) The safety devices (e.g. photocells, safety edges, etc.) protect areas wherethere is a mechanical movement
hazard, e.g. crushing, entrapment and shearing.
17) Each installation must be fitted with at least one flashing light (e.g. FAAC LAMP, MINILAMP etc.) as well as a warning
plate suitably fixed to the gate, besides the safety devices as per point 16. above.
18) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts
other than FAAC original parts are used.
19) Use only FAAC original spare parts for maintenance operations.
20) Do not carry out any modifications to automation components.
21) The installer must supply all information regarding manual operation of the system in the event of an emergency
and provide the end-user with the leaflet attached to the product.
22) Keep out of persons when the product is in operation.
23) Keep out of reach of children the remote radio controls and any control devices. The automation could be
operated unintentionally.
24) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be
carried out exclusively by qualified personnel.
25) What is not explicitly stated in these instructions is not permitted.

9
ENGLISH

DESCRIPTION AND TECHNICAL SPECIFICATIONS LAYOUT AND ELECTRICAL WIRING


Table 1: 450 MPS Control unit technical specifications
Power supply 230 V(+6%-10%) - 50 Hz
m d
F4

Absorbed power 10 W
k
F2

Max. motor load 800 W


Max. accessories load 0,5 A
Max. electric lock load 12 VA fgh
Temperature range -20 °C +55 °C l F3

Fuses N. 4 (see fig.1)


Operations logics Automatic / Semi-automatic / Safety / Dead-man
Automatic timer/ button / Step-by-step semi-automatic e OPENING
LEAF DELAY
n
DISABLE
Opening/closing time Adjustable by trimmer (from 0-120 s)
i
FAILSAFE
Pause time Adjustable by trimmer (from 0-240 s) ON-OFF

Closing leaf delay time Adjustable by trimmer (from 0 -28 s)


Opening leaf delay time 2.5 s (Can be disabled through bridge) o
Thrust force Adjustable by trimmer F1 DL4 DL5 DL2
DL1
Terminal block inputs Open/Open single leaf/Stop/Opening safeties/Closing
DL3
safeties/ mains power +earth J1 J2 J3

Terminal block outputs Flashing light - motors - 24 Vdc accessories power


supply - 24 Vdc warning light power supply - N L

12 Vac electric lock power supply


Quick connector Decoding cards - RP 433 SL/DS a j b c Fig. 1
Microswitch programmable functions Operating logics - Reversing stroke for
electric lock - Closing safeties logics

J1 J2 J3

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
OP COM CL CL COM OP + — OP — CL NC — B — A — + — + —
N L LAMP MOTOR 1 MOTOR 2 30 Vcc FSW STOP FSWTX W.LIGHT LOCK
BLU
BLU

24 Vdc
3W

M1 M2
230 V 50 Hz

STOP OPEN OPEN FSW TX


C1 C2 IND. TOT.

N.B.: The capacitors are provided with the operators. For the safety and fail-safe devices, see the “Safety devices” section.
Fig. 2
Caution: Before touching the electronic unit (connections, Warning: the max. accessory load is 500 mA. To calculate
programming, maintenance) always switch off the power absorption values, refer to table 2.
supply.
Safety devices
a J1 terminal block (fig. 2) These are all devices (photocells, safety edges, magnetic
: Earth connection coils, etc.) with an N.C. (normally closed) contact which
N. : power supply 230 V~ ( Neutre ) activate if an obstacle obstructs the area protected by the
L. : power supply 230 V~ ( Phase)
N.B.: For correct operation the card must be connected to the Opening, closing or opening/closing photocells
system’s earth. Install a suitable differential magneto-thermal
circuit-breaker upstream of the system.
b J2 terminal block (fig. 2)
LAMP.: flashing light output ( 230 V ~)
MOTOR 1 Open /Common/ Close: Motor 1 connection
Can be used in one-leaf application.
(leaf closing delay)
A A
MOTOR 2 Close /Common/ Open: Motor 2 connection
Not to be used in one-leaf application. A
N.B. To check the operation of the equipment at the test B
B
bench, a load must be connected on the MOTOR 1 input.
c J3 terminal block: low voltage (fig. 2) used to connect all
accessories (see table 2).

30 Vdc Opening
Closing photocells
– accessories power supply negative photocells
+ accessories power supply positive (+ 30 Vdc)
Fig. 3

10
ENGLISH

safety devices and stop the movement of the gate leaves The purpose of the opening safety devices is to safeguard
(fig. 3). the zone behind the gate leaves (A, fig. 3).
The 450 MPS card has an additional FAIL-SAFE device which CL. - Closing safety device contact (N.C.): in the A-S-E-EP-AD
serves to check that the N.C. contact on the photocell logics, during the closing phase the safety devices reverse
receiver is working efficiently before any operation (Can the direction of movement of the gate leaves, or they stop
be disabled through bridge Fig. 1 ref.15) . the movement of the leaves then reverse direction when
N.B.: If the Opening safety devices are engaged when the they are disengaged (see microswitch SW4 settings). They
gate is closed, they prevent the leaves from opening. do not engage during the opening cycle.
If the Closing safety devices are engaged when the gate In B, C and B/C logics, they interrupt movement during the
is open, they prevent the leaves from closing. closing cycle. They do not engage during the opening
OP. - Opening safety device contact (N.C.): in the A-S-E-EP-AD cycle.
logics, during the opening phase the safety devices stop N.B.: If closing safety devices are not connected, jumper
the movement of the gate leaves; when they are inputs OP and FSWTX (fig. 4).
disengaged the opening movement recommences. They The purpose of the closing safety devices is to safeguard
do not engage during closure. the zone in which the leaves move during the closing cycle
In the B, C and B/C logics, they interrupt movement during (B, fig. 3).
the opening cycle. They do not engage during the closing If the Fail-Safe function is not used, see cabling at page 4
cycle. for connections of photocells.
N.B.: If opening safety devices are not connected, jumper
inputs OP and FSW TX (Fig. 4).

Application examples
The following are the commonly used connection arrangements (enable fail -safe):

No safety device connected One pneumatic edge connected as closing safety device and
one connected as opening safety device
14 15 16 23 24 14 15 16 23 24
OP — CL + — OP — CL + —
FSW FSWTX FSW FSWTX

Fig. 4 Fig. 5

1 pair of closing photocells connected 1 pair of opening photocells connected


12 13 14 15 16 23 24 23 24
12 13 14 15 16
+ — OP — CL + — + —
30Vcc FSW FSWTX
+ — OP — CL
30Vcc FSW FSWTX

1 1
2 2
1 1
3 3
2 2
4 4
5 5
RX TX RX TX
Fig. 6 Fig. 7

1 pair of opening photocells and 1 pair of closing 1 pair of closing photocells and 1 pair of opening/closing
photocells connected photocells connected

12 13 14 15 16 23 24 12 13 14 15 16 23 24
+ — OP — CL + — + — OP — CL + —
30Vcc FSW FSWTX 30Vcc FSW FSWTX

1 1
2 2
1 1
3 3
2 2
4 4

5 5

RX CL TX CL RX CL TX CL

1
1
2
2
1
1 3
3
2
2 4
4
5
5
TX OP RX OP
TX OP RX OP

Fig. 8 Fig. 9
Important: for further information on the operation of the safety devices, see table 3.

11
ENGLISH

Application examples
The following are the commonly used connection arrangements (disable fail -safe)

No safety device connected One pneumatic edge connected as closing safety device and
one connected as opening safety device

14 15 16 23 24 14 15 16 23 24
OP — CL + — OP — CL + —
FSW FSWTX FSW FSWTX

Fig. 4/A Fig. 5/A

1 pair of closing photocells connected 1 pair of opening photocells connected

12 13 14 15 16 23 24
12 13 14 15 16 23 24 + —
+ — OP — CL
+ — OP — CL + — 30Vcc FSW FSWTX
30Vcc FSW FSWTX

1 1
2 2
1 1
3 3
2 2
4 4
5 5
RX TX
RX TX

Fig. 6/A Fig. 7/A

Two pair of closure photocells connected 1 pair of closing photocells and 1 pair of opening/closing
photocells connected

12 13 14 15 16 23 24 12 13 14 15 16 23 24
+ — OP — CL + — + — OP — CL + —
30Vcc FSW FSWTX 30Vcc FSW FSWTX

1 1
2 2
1 1
3 3
2 2
4 4
5 5

RX TX RX TX

5 5
4 4
1 1
3 3
2 2
2 2
1 1

TX RX TX RX
Fig. 8/A Fig. 9/A

12
ENGLISH

STOP Table 2 - Current drawn by accessories


– Common ( - )
ACCESSORY CURRENT DRAWN
N.C. - STOP contact: all devices (such as pushbuttons)
which by opening a contact stop gate movement. PLUS 40 SL 30 mA
To install several safety stop devices, connect the N.C. PLUS 433 E 20 mA
contacts in series. MINIDEC SL / DS 6 mA
N.B. If the STOP devices are not connected, jumper STOP DECODER SL / DS 20 mA / 55 mA
and - inputs. RP 433 SL / DS 12 mA / 6 mA
B - SINGLE LEAF OPENING (N.O.): all devices (e.g. pushbutton) DIGICARD 15 mA
which, by closing a contact activates opening and/or METAL DIGIKEY 15 mA
closing of the leaf driven by motor 1. FOTOSWITCH 90 mA
– Common ( - ) DETECTOR F4 / PS6 50 mA
A - TWO-LEAF OPENING (N.O.): all devices (pushbuttons , PHOTOBEAM 50 mA
photocells, detectors, etc.) which assures opening/closing WARNING LIGHT 150 mA
of both leaves by closing a contact.
To install several control devices, connect the N.O. contacts
in parallel.
FSWTX
+ – Photocell transmitter power supply (FailSafe)
To use the Fail-Safe function, power supplies to the photocell PLUS
433 E
transmitters must be connected.
W.LIGHT
+ – Warning lamp power supply 24 Vdc 3 W max.
For correct operation of the system, do not exceed stated
power (see table 2).
450 MPS
LOCK
12 Vac electric lock power supply.
d J4 quick connector for decoder SL/DS - MINIDEC SL/DS - RP DECODER
SL
433 SL/DS cards (figs. 10-11-12-13) MINIDEC

e TORQUE trimmer: thrust adjusting trimmer (anti-crushing


SL/DS

safety system).
f PAUSE trimmer: pause time adjusting trimmer (A/S/AD Fig. 10 Fig. 11
logics).
Pause time is adjustable from 0 to 240 seconds.
g OP/CL trimmer: Opening/Closing time adjusting trimmer
Time is adjustable from 0 to 120 seconds.
h LEAF DELAY trimmer: closing leaf delay adjusting trimmer.
Leaf delay time is adjustable from 0 to 28 seconds.
N.B.:
1) If the opening/closing time is less than the set delay
time, the delayed leaf closes at the end of the closing
time.
2) In one-leaf application, set the leaf delay time to
minimum
i Programming microswitches
j Fuse F1 5x20 5 A/250 V rapid (motor power supply)
k Fuse F2 5x20 800 mA/250 V delayed (accessories power
supply)
l Fuse F3 5x20 1.6 A/250 V delayed (electric power supply)
m Fuse F4 5x20 250 mA/250 V delayed (transformer power
supply)
n Bridge to enable/disable the Fail-Safe (Fig. 14). N.B. Use a dedicated decoder for other accessory types.

o Bridge to enable/disable the wing opening


Fig. 12
delay(Fig. 14).

Fig. 13

13
ENGLISH

4) Switch on the power.


5) Send an OPEN signal to input A (fig. 2) and check that the
leaf opens.
If the gate closes, invert the motor wires on the control unit
(brown and black wires).
2.2. OPERATION TIME ADJUSTMENT
Opening/closing times are set by the OP/CL trimmer on the
FAIL-SAFE Disable Enable
control unit (fig. 1 - ref.7).
LEAF DELAY Enable Disable To reduce operation time, adjust the trimmer anticlockwise
Fig. 14 To increase operation time, adjust the trimmer clockwise.
Maximum operation time is 120 seconds.
For 90° opening the approximate opening/closing time is 18
1. PROGRAMMING THE MICROSWITCHES seconds.
For optimal system efficiency set the opening/closing time so
Automation programming is carried out by the microswitches that the electric motor remains activated for a few seconds
(fig. 1 - ref. 9) as shown in the diagram below. after the leaf has reached the mechanical travel stop.
2.3. CLOSING LEAF DELAY ADJUSTMENT
Fig. 15 In the case of overlapping leaves, it is possible to delay closing
of the leaf driven by motor M1 (see fig. 2) to ensure correct
1 2 3 4 5
closure of the gate.
Set the delay by the LEAF DELAY trimmer on the 450 MPS control
unit (fig. 1 - ref. 8).
REVERSING STROKE FOR
SW1 SW2 SW3 SW5
OPERATING LOGICS
ELECTRIC LOCK To reduce delay time, adjust the trimmer anticlockwise.
A OFF OFF OFF NOT ACTIVATED OFF To increase delay time, adjust the trimmer clockwise.
S ON OFF OFF ACTIVATED ON
Maximum delay time is 28 seconds. If the operation time is
E OFF ON OFF
EP ON ON OFF
shorter, the delay time is reduced automatically.
SAFETIES ON CLOSING SW4
B ON ON ON
2.4. SETTING PAUSE TIME
C OFF OFF ON INVERTS MOVEMENT
OFF
B/C OFF ON ON IMMEDIATELY When A or S logics are selected, the leaf momentary stop time
AD ON OFF ON STOPS AND INVERTS
MOVEMENT ON ON
can be set using the PAUSE trimmer (fig. 1 ref. 6).
DISENGAGEMENT Turn the trimmer clockwise to increase the time.
Turn the trimmer anticlockwise to reduce the time.
1.1. OPERATION LOGICS The maximum pause time is 240 sec.
There are seven operating logics available: 2.5. ANTI-CRUSHING SYSTEM ADJUSTMENT
A : “AUTOMATIC ” E : “SEMI-AUTOMATIC”
The 450 MPS control unit has been designed for use on both
S : “SAFETY” EP : “SEMI-AUTOMATIC STEP-BY-STEP”
electromechanical and hydraulic operators.
B : “DEAD-MAN BUTTON” C : “DEAD-MAN BUTTON”
When the 450 MPS card is used on electromechanical operators,
B/C : “DEAD-MAN BUTTON” AD :“AUTOMATIC TIMER”
the torque control device must be set by turning the TORQUE
Operation of the different logics is described in tables 3/a-b-c-d-e-f-g-h. trimmer (fig. 1 ref. 5).
1.2. REVERSING STROKE FOR ELECTRIC LOCK To reduce torque, adjust the trimmer anticlockwise.
To increase torque, adjust the trimmer clockwise.
This function is to be activated only if the electric lock is
installed. In any event, FAAC advises not to exceed a torque of 15 Kg
measured on the outer edge of the leaf.
1.3. SAFETIES ON CLOSING To ensure precise torque adjustment use a linear dynamometer.
This function serves to select the operating mode for the closing When the 450 MPS card is used on hydraulic operators, the
safeties: torque control device must be set to the maximum value by
- OFF: immediate reverse of movement during gate closure turning the TORQUE trimmer clockwise.
- ON: movement is stopped during closing and reversed on This device is already present inside the operator hydraulic
opening when the safety is disengaged. circuit (BY-PASS valves).

2. START-UP
1) Program the 450 MPS electronic control unit according to
specific requirements as shown in fig. 14.
2) Check led status as shown in table.
LED functions
LEDS ON OFF
DL 1 (OPEN INPUT A) Command active Command not active
DL 2 (OPEN INPUT B) Command active Command not active
DL 3 (STOP) Command not active Command active
DL 4 (FTSW OPEN) Safeties disengaged Safeties engaged
DL 5 (FTSW CLOSE) Safeties disengaged Safeties engaged
N.B.: the bold text indicates led status with gate idle.
2.1. DIRECTION OF ROTATION
1) Switch off the power.
2) Manually move the gate to halfway.
3) Lock the operators.

14
Table 3/a
LOGICS "A" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
CLOSED Opens leaves and Opens single leaf and re-closes
No effect (OPEN inhibited) No effect No effect (OPEN inhibited) off
recloses after pause time after pause time
OPEN on PAUSE Recloses leaves immediately Recloses leaf immediately No effect Freezes pause until disengagement (*1) (OPEN inhibited) on
CLOSING Reopens leaves immediately Reopens leaf immediately No effect (OPEN inhibited) See paragraph 1.3 Stops closing and, when disengaged, opens flashing light
Stops
OPENING No effect Stops opening and, when disengaged, closes Stops opening and, when disengaged,
No effect on
continues to open
STOPPED Closes the leaf/leaves No effect (OPEN inhibited) No effect No effect (OPEN inhibited) on

Table 3/b
LOGICS "S" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
Opens leaves and Opens single leaf and No effect (OPEN inhibited) No effect No effect (OPEN inhibited) off
CLOSED recloses after pause time recloses after pause time
OPEN on PAUSE Recloses leaves immediately Recloses leaf immediately No effect Freezes pause until disengagement (*1) (OPEN inhibited) on

CLOSING Reopens leaves immediately Reopens leaf immediately No effect (OPEN inhibited) See paragraph 1.3 Stops closing and, when disengaged, opens flashing light
Stops
Stops opening and, when disengaged,
OPENING Recloses leaves immediately Recloses leaf immediately Stops opening and, when disengaged, closes No effect on
continues to open
STOPPED Closes the leaf/leaves No effect (OPEN inhibited) No effect No effect (OPEN inhibited) on

15
Table 3/c
LOGICS "E" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
CLOSED Opens leaves Opens single leaf No effect (OPEN inhibited) No effect No effect (OPEN inhibited) off

OPEN Recloses leaves immediately Recloses leaf immediately No effect No effect (OPEN inhibited) on
CLOSING Reopens leaves immediately Reopens leaf immediately Stops No effect (OPEN inhibited) See paragraph 1.3 Stops closing and, when disengaged, opens flashing light

Stops opening and, when disengaged,


OPENING Stops Stops opening and, when disengaged, closes No effect on
continues to open

STOPPED Closes the leaf/leaves No effect (OPEN inhibited) No effect No effect (OPEN inhibited) on

Table 3/d
LOGICS "EP" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
CLOSED Opens leaves Opens single leaf No effect (OPEN inhibited) No effect No effect (OPEN inhibited) off

OPEN Recloses leaf/leaves immediately No effect (OPEN inhibited) on


No effect
CLOSING Stops See paragraph 1.3 Stops closing and, when disengaged, opens flashing light
Stops
Stops opening and, when disengaged,
OPENING Stops Stops opening and, when disengaged, closes No effect on
continues to open
ENGLISH

STOPPED Inverts the direction No effect (OPEN inhibited) No effect (if the gate must open, inhibits OPEN) No effect (if gate must close, inhibits OPEN) No effect (OPEN inhibited) on
Table 3/e
LOGICS "B" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
No effect No effect No effect No effect off
CLOSED Opens the leaf/leaves Closes the leaf/leaves (OPEN A/B inhibited) (OPEN-A inhibited) (OPEN A/B inhibited)
(OPEN-B inhibited)
ENGLISH

No effect No effect No effect No effect


OPEN Opens the leaf/leaves Closes the leaf/leaves (OPEN-A inhibited) (OPEN-B inhibited) on
(OPEN A/B inhibited) (OPEN A/B inhibited)
Interrupts operation Interrupts operation
No effect No effect No effect flashing light
CLOSING Stops (OPEN-B inhibited) (OPEN-A/B inhibited)
Interrupts operation Interrupts operation
OPENING No effect No effect No effect on
(OPEN-A inhibited) (OPEN-A/B inhibited)
No effect No effect No effect No effect on
STOPPED Opens leaves or 1 leaf Closes leaves or 1 leaf
(OPEN A/B inhibited) (OPEN-A inhibited) (OPEN-B inhibited) (OPEN A/B inhibited)
Table 3/f
LOGICS "B/C" OPENING PULSE/HOLD TO RUN CONTROL
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
No effect No effect No effect No effect off
CLOSED Opens the leaf/leaves Closes the leaf/leaves (OPEN A/B inhibited) (OPEN-A inhibited) (OPEN A/B inhibited)
(OPEN-B inhibited)

No effect No effect No effect No effect


OPEN Opens the leaf/leaves Closes the leaf/leaves (OPEN-A inhibited) (OPEN-B inhibited) on
(OPEN A/B inhibited) (OPEN A/B inhibited)
Interrupts operation Interrupts operation
No effect No effect No effect flashing light
CLOSING Stops (OPEN-B inhibited) (OPEN-A/B inhibited)
Interrupts operation Interrupts operation
OPENING No effect No effect No effect on
(OPEN-A inhibited) (OPEN-A/B inhibited)
No effect No effect No effect No effect

16
STOPPED Opens leaves or 1 leaf Closes leaves or 1 leaf on
(OPEN A/B inhibited) (OPEN-A inhibited) (OPEN-B inhibited) (OPEN A/B inhibited)

Table 3/g
LOGICS "C" HOLD-TO-RUN CONTROLS
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
No effect No effect Interrupts operation No effect off
CLOSED Opens the leaf/leaves Closes the leaf/leaves (OPEN A/B inhibited) (OPEN-A inhibited) (OPEN-B inhibited) (OPEN A/B inhibited)

No effect No effect Interrupts operation No effect


OPEN Opens the leaf/leaves Closes the leaf/leaves (OPEN-A inhibited) on
(OPEN A/B inhibited) (OPEN-B inhibited) (OPEN A/B inhibited)

No effect No effect Interrupts operation Interrupts operation


CLOSING No effect flashing light
Stops (OPEN-B inhibited) (OPEN-A/B inhibited)
Interrupts operation No effect Interrupts operation
OPENING No effect No effect on
(OPEN-A inhibited) (OPEN-A/B inhibited)

Table 3/h
LOGICS "AD" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETIES CLOSING SAFETIES OPENING/CLOSING SAFETIES W.L.
CLOSED Opens leaves and Opens single leaf and re-closes
No effect (OPEN inhibited) No effect No effect (OPEN inhibited) off
recloses after pause time after pause time
OPEN on PAUSE It controls the re-counting of the It controls the re-counting of the No effect Freezes pause until disengagement (*1) (OPEN inhibited) on
pause time pause time
No effect (OPEN inhibited) See paragraph 1.3 Stops closing and, when disengaged, opens flashing light
CLOSING Reopens leaves immediately Reopens leaf immediately Stops
Stops opening and, when disengaged, closes Stops opening and, when disengaged,
OPENING No effect on
If held, it remains in pause (timer function). continues to open
STOPPED Closes the leaf/leaves No effect (OPEN inhibited) No effect No effect (OPEN inhibited) on

(*1) If residual pause time is less than 5 seconds on safety disengagement, the gate closes after 5 seconds.
N.B.: Effects of other active impulse inputs are shown in brackets
Le descrizioni e le illustrazioni del presente manuale non sono impegnative. La FAAC si riserva il diritto,
lasciando inalterate le caratteristiche essenziali dell’apparecchiatura, di apportare in qualunque

para la naturaleza
100% papel reciclado
momento e senza impegnarsi ad aggiornare la presente pubblicazione, le modifiche che essa ritiene
convenienti per miglioramenti tecnici o per qualsiasi altra esigenza di carattere costruttivo o
commerciale.
The descriptions and illustrations contained in the present manual are not binding. FAAC reserves the
right, whilst leaving the main features of the equipments unaltered, to undertake any modifications
it holds necessary for either technical or commercial reasons, at any time and without revising the
present publication.
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le
droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant
les caractéristiques essentielles, sans devoir pour autant mettre à jour cette publication.
Die Beschreibungen und Abbildungen in vorliegendem Handbuch sind unverbindlich. FAAC behält

ist umweltfreundlich
sich das Recht vor, ohne die wesentlichen Eigenschaften dieses Gerätes zu verändern und ohne
Verbindlichkeiten in Bezug auf die Neufassung der vorliegenden Anleitungen, technisch bzw.
konstruktiv/kommerziell bedingte Verbesserungen vorzunehmen.

100% Altpapier
Las descripciones y las ilustraciones de este manual no comportan compromiso alguno. FAAC se
reserva el derecho, dejando inmutadas las características esenciales de los aparatos, de aportar, en
cualquier momento y sin comprometerse a poner al día la presente publicación, todas las
modificaciones que considere oportunas para el perfeccionamiento técnico o para cualquier otro
tipo de exigencia de carácter constructivo o comercial.

FAAC per la natura


• La presente istruzione è realizzata al 100% in carta riciclata.
• Non disperdete nell'ambiente gli imballaggi dei componenti dell'automazione bensì selezionate
i vari materiali (es. cartone, polistirolo) secondo prescrizioni locali per lo smaltimento rifiuti e le
norme vigenti.

papier recyclé 100%


FAAC for the environment

pour la nature
• The present manual is produced in 100% recycled paper
• Respect the environment. Dispose of each type of product packaging material (card, polystyrene)
in accordance with the provisions for waste disposal as specified in the country of installation.
FAAC der Umwelt zuliebe
• Vorliegende Anleitungen sind auf 100% Altpapier gedruckt.
• Verpackungsstoffe der Antriebskomponenten (z.B. Pappe, Styropor) nach den einschlägigen
Normen der Abfallwirtschaft sortenrein sammeln.
FAAC écologique
• La présente notice a été réalisée 100% avec du papier recyclé.
• Ne pas jeter dans la nature les emballages des composants de l’automatisme, mais sélectionner
les différents matériaux (ex.: carton, polystyrène) selon la législation locale pour l’élimination des
déchets et les normes en vigueur.
FAAC por la naturaleza.
• El presente manual de instrucciones se ha realizado, al 100%, en papel reciclado.
• Los materiales utilizados para el embalaje de las distintas partes del sistema automático (cartón,
poliestireno) no deben tirarse al medio ambiente, sino seleccionarse conforme a las prescripciones
locales y las normas vigentes para el desecho de residuos sólidos.

recycled paper 100%


for nature

FAAC S.p.A.
Via Benini, 1
40069 Zola Predosa (BO) - ITALIA
Tel.: 051/6172411 - Tlx.: 521087
Fax: 051/758518

Timbro del Rivenditore:/Distributor’s Stamp:/Timbre de l’Agent:/ Fachhändlerstempel:/Sello del Revendedor:


carta riciclata 100%
732260 - Rev. D - 11000 - 697 - M

per la natura