Zoncare-Q9: High End Full Digital Color Doppler Ultrasound Diagnostic System
This document provides an overview of the Zoncare-Q9, a high-end full digital color Doppler ultrasound diagnostic system. It has applications in abdomen, cardiac, obstetrics, gynecology, urology, small parts, vascular, and pediatrics imaging. Key features include a 10.4" touch screen, 4 transducer ports, over 50,000 image storage capacity, and the ability to perform 2D, M-mode, Doppler, and 4D/5D imaging with bundled transducers for various applications.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
124 views7 pages
Zoncare-Q9: High End Full Digital Color Doppler Ultrasound Diagnostic System
This document provides an overview of the Zoncare-Q9, a high-end full digital color Doppler ultrasound diagnostic system. It has applications in abdomen, cardiac, obstetrics, gynecology, urology, small parts, vascular, and pediatrics imaging. Key features include a 10.4" touch screen, 4 transducer ports, over 50,000 image storage capacity, and the ability to perform 2D, M-mode, Doppler, and 4D/5D imaging with bundled transducers for various applications.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7
ZONCARE-Q9
High End Full Digital Color Doppler Ultrasound Diagnostic System
System Overview Hard Disc: ≥ 320GB
Application Footswitch: BNC/USB Abdomen Ethernet Port: 1 (10Mb/1000Mb) Cardiac External Display: DVI, VGA Obstetrics External VCR Gynecology Digital Video Monitor Urology Compound Video Output Export Image Format: Small Parts USB Modem PNG, JPEG, BMP, GIF, DICOM Vascular USB Printer Cine Frame Capacity: Pediatrics Peripherals/Storage Tray > 8000 frames Digital B/W Thermal Printer Stored Image Capacity: Electrical Power DVD/CD Recorder > 50000 images Voltage: 100V~240V CD-R Storage Current: 7.0A/4.0A Cine/Image Memory DVD Storage Frequency: 50/60Hz Cine Memory: 128Mb Cine Review Speed: 1/8, 1/4, 1/2, 1, 2 Technology Transducer/Gel Holders Cine Review Loop TP-view Tech Transducer/Gel Holders: 6 Cine Capture Function Panoramic Imaging Tech Transducer Hooks: 2 Dual/Quad Image Cine Display Speckle Reduction Tech Gel Heater: 1 Measurements, Calculations, Annotations- Dual & Triplex Synchronous Display Physical Specifications on Cine Playback (still image) Directional Power Doppler Equipment: Elastography Tech 910mm×660mm×1470mm; 68kg DICOM & EMR Connectivity Real-time 4D Volume Imaging Tech Package: DICOM3.0 Compliant Expand-Pulse-Inversion Imaging Tech 1035mm×725mm×1535mm; 128kg DICOM Work-list Color Deflection Tech DICOM Storage Free-hand 3D Imaging Tech Conditions DICOM Structured Reporting Spatial-Compound Imaging Tech Operating DICOM Print Pulse-Inversion Harmonic Imaging Tech Temperature: 10°C~40°C DICOM Commit Imaging Parameters Preset Humidity: 30%~75% Electronic Medical Record Custom Key/Optimization Key Pressure: 50kPa~106kPa RIS HL7 Port Shipping/Storage General Performance Temperature: -15°C~50°C Image Storage Digital Broadband: 8192 channels Humidity: 10%~90% Storage Format: Beam-former: Re-programmable Pressure: 50kPa~106kPa PNG, AVI, MPEG, RAW (cine) Transmit Voltage: Adjustable (16 steps) Export Video Format: Beam-former Frequency Range: 1~40 MHz Connectivity/Media/Peripherals AVI, MPEG, DICOM Transducer Ports: 4 (Activated) USB Ports: 5
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: Zoncare Building, 380#, High-tech 2nd road, Eastlake High-tech Development Zone, Wuhan, Hubei 430206 P.R.C.P Tel: 86-27-87770203 Email: [email protected] Fax: 86-2787770581 Website: www.zoncare.com/en/ ZONCARE-Q9 High End Full Digital Color Doppler Ultrasound Diagnostic System
Pan/Zoom Embedded Computer Geometric Focus Approx: 90 mm
Real-Time Image Zoom CPU: Frozen Image Zoom Intel E4300 (Minimum) Micro-Convex Array Probe: Read Zoom Range: 100%~500% Hard Drive (Patient) Data: Frequency: Write Zoom Range: 100%~300% ≥ 500 GB Central 4 MHz Up/Down/Left/Right Inversion Average Min. 3.6 MHz Audio: Speakers Max. 4.4 MHz ECG (Optional) Internal/External: Internal (stereo) Pitch: 0.28 mm ECG Module Frequency Range: 200Hz~17 kHz Radius: 20 mm ECG Lead Impedance: 4Ω Number of Elements: 128 ECG Invert Power: 5W Geometric Focus Approx: 90 mm ECG Baseline Sound Pressure: 80 dB/W ECG Gain Size: 105mm×35mm×20.3mm Linear Array Probe: Frequency: Hardware Specification UPS (Optional) Central 10 MHz LED Monitor Voltage: 100V~240V Average Min. 7.2 MHz Size (Diagonal): 19” Frequency: 50/60Hz Max. 8.8 MHz Contrast Ratio: 1500:1 Current: 7.0A/4.0A Pitch: 0.390 mm Resolution: 1024×768 pixels Runtime: > 90 minutes Radius: N/A 2 Brightness: 250 cd/m Weight: 11kg Number of Elements: 128 Color Depth: 24bit Dimensions: 295mm×265mm×90mm Geometric Focus Approx: 30 mm Rotate Angle: ± 90° Grey Levels: 256 Imaging Performance Intra-Cavity Probe: Startup Time (Max): Frequency: Touch Screen Avg. <60 seconds Central 6.5 MHz Size (Diagonal): 10.4” Preset Switching Time: Average Min. 5.85 MHz Weight: 500g Avg. < 1 second Max. 7.15 MHz Contrast Ratio: 600:1 Storage Time (Image to Disk): Pitch: 0.205 mm Resolution: 1024×768 pixels Avg. < 0.5 second Radius: 10 mm 2 Brightness: 450 cd/m Number of Elements: 128 Grey Levels: 64 Transducers Geometric Focus Approx: 35 mm Input Signal: LVDS Convex Array Probe Compatible with bare hands/thin medical Frequency: Phased Array Probe: gloves (e.g., latex, vinyl, nitrile) Central 3.3 MHz Frequency: Average Min. 3.15 MHz Central 2.5 MHz Console Max. 3.85 MHz Average Min. 2.25 MHz Console Adjustment: Pitch: 0.468 mm Max. 2.75 MHz Tilt & Swivel Radius: 60 mm Pitch: 0.300 mm Number of Elements: 128 Radius: N/A
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: Zoncare Building, 380#, High-tech 2nd road, Eastlake High-tech Development Zone, Wuhan, Hubei 430206 P.R.C.P Tel: 86-27-87770203 Email: [email protected] Fax: 86-2787770581 Website: www.zoncare.com/en/ ZONCARE-Q9 High End Full Digital Color Doppler Ultrasound Diagnostic System Diameter Reduction: B/PW, B/CW, B B/Power, Dual B/Power Point to Point Dual Compound, B/Elasto, B B/Elasto Number of Elements: 64 Area: B B/TDI, Dual B/TDI Geometric Focus Approx: 30 mm Cross, Ellipse, Trace, B/C/M, B/C/PW, B/C/CW Point to Point B/Power/M, B/Power/PW, B/Power/CW 4D Volume Probe Area Reduction: B/TDI/M, B/TDI/PW, B/TDI/CW Ellipse/Ellipse, Ellipse/Trace, Software Specifications Trace/Trace B-Mode Software Languages Hip Angle Maps: 17 English D: d Ratio Focus Count: Max. 10 German Gain: 0~100% Spanish Doppler Auto-Focus: Available Italian Velocity: TGC: 8 Sliders Czech Single, Double (PSV/EDV) Dynamic Range: 145dB French Time/Slope: Depth: Max. 36cm Russian Time/Distance/Slope Acoustic Power: 0 ~ (-15) dB Simplified Chinese Trace: Chroma: 8 Brazilian Portuguese Point to Point, Trace, Range Grayscale Levels: 256 Auto-Trace: Frame Rate: > 500Hz User Interface PSV, EDV, MV, AT, DT, RI, Max Steer Angle: 17.5° Cine Playback PI, SD, VTI, PGr, MGr, HR Max. Line Density: 512 Multiple Arrows Persistence/ Frame Average: Up to 7 Configurable Worksheets Imaging Modes Spatial-Compound Imaging: 7, 3, 5 Lines Exam Review Overview Top/Bottom/Left/Right Reverse Pictograms (Body Marks) B, Dual B, Quad B Clarity Adaptive Speckle Reduction: System Setup Menu M, Color M, Anatomical M Off, Low, Med, High, Max Programmable Annotations Color, Dual Color, Simultaneous 2D/Color Compound, Dual Compound M-Mode Max Onscreen Measurements PW, CW, Triplex Maps: 16 Distance: 25 CFM, PD, Directional PD, CD Chroma: 17 Area: 12 Freehand 3D Sweep Speed: 3 Volume: 8 Standard 3D/4D, Advanced 3D/4D Anatomic M-Mode: Available Panoramic, Elastography Gain: 0~100% Measurement Tools Tissue Doppler Imaging (TDI) Distance: Point-to-Point B-Mode Expand Pulse Imaging (EPI) Max Steer Angle: 15° Distance: Diameter Reduction: Point-to-Point Point to Point, Curve Combined Modes Heart Rate/Time/Distance/Slope Angle: Dual B, Quad B, B/M, B B/C, Dual B/C Side-by-Side/Top/Bottom Layout Vector Angle
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: Zoncare Building, 380#, High-tech 2nd road, Eastlake High-tech Development Zone, Wuhan, Hubei 430206 P.R.C.P Tel: 86-27-87770203 Email: [email protected] Fax: 86-2787770581 Website: www.zoncare.com/en/ ZONCARE-Q9 High End Full Digital Color Doppler Ultrasound Diagnostic System
Color Mode Chroma: 17 Frames per Volume: 3~125
Gain: 0~100% Sample Volume Size: 0.5mm~40mm Field of View (Max): 5°~75° Color Maps: 9 Doppler Multi-Frequency:1.67MHz, Max Volume Rate: 3 Color Visibility: Off/On 2MHz, 2.5MHz, 3.33MHz, 4MHz Viewing Options: A/B/C/VR, A/VR, Doppler Steer Angles: 5 Steps Auto-Trace, Baseline, Side-by-Side/Top/ C/VR, V PRF: 0.2 kHz~10 kHz Bottom Layout, Invert, Duplex Rendering Methods: Surface, Surface- Wall Filter: 1-50% of PRF Smooth, Maximum, X-Ray Max. Steer Angle: 15° Freehand 3D Mode Live 3D/4D imaging, One Sweep 3D, Doppler Multi-Frequency: 2MHz~10MHz Maps: 17 Rendering 3D ROI, Multi-Slice, Priority: 0~250 Rendering Quality: Low, Med, High 3D Niche Mode, Measurements, Color Modes: Color & Power Methods: Parallel, Fan Sculpt, Annotations, Contrast, Threshold, Line Density Max: 256 Lines Frames per Volume: 3~125 Save Cine-loops, Save Volume Persistence/Frame Average: Up to 9 Frames Line Density: 64~192 Baseline/Invert/Color ROI/M-Mode Field of View (Max): 5°~75° Compound Viewing Options: A/B/C/VR, A/VR, Frame Count: 3 or 5 Lines (Tx/Rx) PW Mode C/VR, V Focus Count: Max. 2 Gain: 0~100% Rendering Methods: Surface, Surface- Max Line Density: 256 Sweep Speed: 5 Smooth, Maximum, X-Ray Compound Levels: Med, High, Shine Doppler Steer Angles: 5 Steps 3D ROI, 3D Niche Mode, Measurements, Maps: 3 Sculpt, Annotations, Contrast, Threshold Panoramic Max Steer Angle: 15° Max Length: > 0.8m Spectrum Filter (Edge): 0~12 Standard 3D/4D Mode Zoom, Rotate, Pan: Available Audio: 0~100% Maps: 17 Correction Angle: 80°/-80° Line Density: 64~192 Elastography (Optional) Doppler Multi-Frequency: 2MHz~10MHz Rendering Quality: Low, Med, High Maps: 20 Chroma: 17 Frames per Volume: 3~125 Transparency: 0~100% Sample Volume Size: 0.5mm~40mm Field of View (Max): 5°~75° Max Frame Rate: 30Hz Auto-Trace, Baseline, Side-by-Side/Top/ Viewing Options: A/B/C/VR, A/VR, Region Selection: all, soft, med, hard Bottom Layout, Invert, Duplex, Triplex C/VR, V ROI, Stiffness Display Filter, Strain Ratio Rendering Methods: Surface, Surface- CW Mode Smooth, Maximum, X-Ray Analysis Packages Gain: 0~100% One Sweep 3D, 3D ROI, 3D Niche Mode, OB Sweep Speed: 5 Measurements, Sculpt, Annotations, Cardiac Doppler Steer Angles: 5 Steps Contrast, Threshold Abdominal Maps: 3 GYN Max Steer Angle: 15° Advanced 3D/4D Mode Urology Spectrum Filter (Edge): 0~12 Maps: 17 Vascular Audio: 0~100% Line Density: 64~192 Small Parts Correction Angle: 80°/-80° Rendering Quality: Low, Med, High
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: Zoncare Building, 380#, High-tech 2nd road, Eastlake High-tech Development Zone, Wuhan, Hubei 430206 P.R.C.P Tel: 86-27-87770203 Email: [email protected] Fax: 86-2787770581 Website: www.zoncare.com/en/ ZONCARE-Q9 High End Full Digital Color Doppler Ultrasound Diagnostic System
Abdomen (All Modes) LA/Ao (M): Abdomen: Vessel: Ao Root, LA Diam, ACS, Ao Root Ampl, Liver, GB, GBWT, CBD, Portal Vein, Vessel Area, Stenosis Area, Auto Trace, ET, HR Spleen, GB L/H/W PS, RI, S/D, Time, Manual Trace, ED, PI, (M-Mode, Color M, Anatomical M) (All Modes) Vessel Dia, Stenosis Dia, HR LV Simps.: Abdomen PW: (All Modes) A4C Dias, A4C Sys, A2C Dias, A2C Sys, Portal V, Hepatic A, RHV, MHV, LHV HR (All Modes) Breast (B-Mode, Dual B/Quad B, Lt/Rt Kidney: Left/Right Breast: Compound/Dual Compound) L, H, W, Cortex LtL1, LtL2, LtL3, LtL4, LtL5 Qp/Qs: (All Modes) (All Modes) LVOT VTI, RVOT VTI, LVOT Diam, Lt/Rt Kidney PW: RVOT Diam, HR Lt/Rt Vel Prox/Md/Dist, Lt/Rt Trace Cardiac (B-Mode, PW Doppler, CW Doppler, Prox/Mid/Dist MV: Triplex) (All Modes) Diameter, MVA (Trace), HR RV/LV: Lt/Rt Renal A.: (B-Mode, Dual B/Quad B, RVWd, RVDd, IVSd, LVDd, LVPWd, Lt/Rt Vel Prox/Mid/Dist, Lt/Rt Trace Compound/Dual Compound) RVWs, RVDs, IVSs, LVDs, LVPWs, HR Prox/Mid/Dist, Lt/Rt Upper/Mid/Lower MV (M): (B-Mode, Dual B/Quad B, Pole D-E Excursion, E-F Slope, A-C, EPSS, Compound/Dual Compound) (All Modes) HR RV/LV (M): Aorta: (M-Mode, Color M, Anatomical M) RVWd, RVDd, IVSd, LVDd, LVPWd, Prox/Mid/Dist Ao AP, Rt/Lt Iliac AP, MV (Color): RVWs, RVDs, IVSs, LVDs, LVPWs, HR Prox/Mid/Dist Ao Width, Rt/Lt Iliac Dist A, Dist B, A (Trace), PISA, (M-Mode, Color M, Anatomical M) Width, AAA L/H/W Diameter, HR TV (Color): (All Modes) (Color M, Simultaneous 2D/Color, TV Diam, PISA, HR Aorta PW: Dual Color, Color Doppler) (Color M, Simultaneous 2D/Color, Dual SMA, Celiac, Ao, Rt/Lt Iliact A/V MV (Doppler): Color, Color Doppler) (All Modes) Peak E, Peak A, PHT, MV VTI, MV Acc, AV (CONT.EQ): Bladder: A Dur, E Dur, IVRT, MR Peak, E/Ea, HR LVOT Diam, LVOT Peak, LVOT VTI, L, H, W, Blad Wall, Rt/Lt Ureter, (PW Doppler, CW Doppler, Triplex) AV Peak, AV VTI, HR Pre/Post-void L/H/W LV Mass A/L: (PW Doppler, CW Doppler, Triplex) (All Modes) EPI Area, Endo Area, LV Length, HR AV (Doppler): Prostate: (B-Mode, Dual B/Quad B, LVOT Peak, LVOT VTI, AV Peak, AV L, H, W Compound/Dual Compound) VTI, AR PHT, End Dias.Vel, LVOT (All Modes) LA/Ao: Diam, HR Dor.PenA: Ao Root, LA, Asc Ao, LVOT Diam, AVA (PW Doppler, CW Doppler, Triplex) Vessel Area, Stenosis Area, Auto Trace, (Trace), HR MV (Doppler): PS, RI, S/D, Time, Manual Trace, ED, PI, (B-Mode, Dual B/Quad B, Peak E, Peak A, PHT, MV VTI, MV Acc,
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: Zoncare Building, 380#, High-tech 2nd road, Eastlake High-tech Development Zone, Wuhan, Hubei 430206 P.R.C.P Tel: 86-27-87770203 Email: [email protected] Fax: 86-2787770581 Website: www.zoncare.com/en/ ZONCARE-Q9 High End Full Digital Color Doppler Ultrasound Diagnostic System
A Dur, E Dur, IVRT, MR Peak, E/Ea, HR Uterus: Lt/Rt Ovary:
Add: Zoncare Building, 380#, High-tech 2nd road, Eastlake High-tech Development Zone, Wuhan, Hubei 430206 P.R.C.P Tel: 86-27-87770203 Email: [email protected] Fax: 86-2787770581 Website: www.zoncare.com/en/ ZONCARE-Q9 High End Full Digital Color Doppler Ultrasound Diagnostic System
Urology Dual Compound) Power cord/grounding cable
Dor.PenA: Stenosis A: Fuse (2) Vessel Area, Stenosis Area, Auto Trace, Lt/Rt Prox/Mid/Dist CCA, User’s Manual PS, RI, S/D, Time, Manual Trace, ED, PI, Lt/Rt Prox/Mid/Dist ICA, Coupling Gel (0.25L) Vessel Dia, Stenosis Dia, HR Lt/Rt Bulb (All Modes) (B-Mode, Dual B, Quad B, Compound, Optional Accessories Prostate: Dual Compound) 17” LCD Monitor L, H, W Stenosis D: 4D Imaging Module (All Modes) Lt/Rt Prox/Mid/Dist CCA, Elastography Module Lt/Rt Testicle: Lt/Rt Prox/Mid/Dist ICA, Convex Array Probe L, H, W Lt/Rt Bulb Micro Convex Array Probe (All Modes) (B-Mode, Dual B, Quad B, Compound, Linear Array Probe Lt/Rt Kidney: Dual Compound) Phased Array Probe L, H, W, Cortex Arterial: Intra-cavity Probe (All Modes) Distance, Area, HR, Velocity, 4D Volume Probe Lt/Rt Kidney PW: Time/Slope, Trace, Range, Diam Red, DICOM 3.0 Lt/Rt Vel Prox/Md/Dist, Area Red, d:D Ratio, Diameter, Pedal Switch Lt/Rt Trace Prox/Mid/Dist Mean Velocity Laser, Ink-jet Printer (All Modes) (All Modes) Puncture Trestle Lt/Rt Renal A.: Lt/Rt Carotid: Barcode Reader Lt/Rt Vel Prox/Mid/Dist, Lt/Rt Prox/Mid/Dist CCA, ECG Lt/Rt Trace Prox/Mid/Dist, Lt/Rt Bulb, Lt/Rt Prox/Mid/Dist ICA, UPS Lt/Rt Upper/Mid/Lower Pole Lt/Rt Prox/Mid/Dist ECA, Lt/Rt Vert Art, (All Modes) Lt/Rt Sub Clav Certificates Bladder: (All Modes) Quality Standards L, H, W, Blad Wall, Rt/Lt Ureter, Venous: ISO9001 Pre/Post-void L/H/W Lt/Rt GSV Prox/Mid/Dist, ISO13485 (All Modes) Lt/Rt SFV Prox/Mid/Dist, CMD Vessel: Lt/Rt CFV, Lt/Rt POPV, CE Vessel Area, Stenosis Area, Auto Trace, Lt/Rt LSV Prox/Mid/Dist, Distance, CE Declaration PS, RI, S/D, Time, Manual Trace, ED, PI, Time ZONCARE-Q9 has been assessed with Vessel Dia, Stenosis Dia, HR (All Modes) respect to the conformity assessment (All Modes) procedure described in Article 11.3.a and Standard Package Annex II excluding section 4 (Module H) of Vascular Main unit (with 19” LED Monitor) Council Directive 93/42/EEC on Medical Intima: 10.4’’ LED touch screen operation Devices, as amended, and found to comply IMT, Lt/Rt Prox/Mid/Dist CCA, Gel Heater (Notified Body No.: 0434) Lt/Rt Bulb Convex Probe (B-Mode, Dual B, Quad B, Compound, 3D Imaging Module/Software