JSA07945E- 13F06146-06147 e-com Electrical drawing

e-com Electrical drawing


Controller Controller

MCB MCB

PGM

PGM
PGA
PGB
To inside

15V

PE
J12
CN6

CN3 J1
CN1 COM A B

CN2 CN2

GND
VCC

W+

U+
W-
A+

B+

V+
U-
V-
A-

B-
1 3 4 5 6 7 8 9 10 11 12 13

cos+
GND

GND
VCC

VCC

cos-
sin+

sin-
W+

U+
W-

B+
V+

Z+

A+
A+

B+

U-
V-
A-

B-

A-
B-

Z-
STP Meaning of pins inside the plug
Model
Shield twist-pair Shield twist-pair cable             
cable cable B- z+ z- A+ A- 0V B+ 5V SIN- SIN+ COS+ COS-
ERN1387 15
5a 4b 4a 6b 2a 5b 3b 1b 1a 7b 2b 6a
PG

PG
Model STP Meaning of pins inside the plug * For gearless motor
cable               

TS5246N*** A+ A- B+ B- U+ U- V+ V- W+ W- VCC COM


15
-8192

Note:
If user earth point is steady, please connect one side of shield layer of encoder cabel
to PE, and leave another side not connecting; if user earth point is not steady, please
connect to 0V instead of PE.
Controller

MCB

PGM

PGA

PGB
15V

PE
CN6

12+

PB
PA
0

* Only for gear motor


Shield twist-pair cable
PG
D..02H
24 42 D..03H
01 D..09H D..09H

MJB-B MP1:01 MP4:3


MJP:13
MJP:12

11 12 13 23 24 31 32 33 34 35 42
MJ6:5 MJ4:8 MJ5:9 MJ13:1 MJ14:2 MJ1:2 JAQ
MJP:10 MJP:11 MJ12:1 MJ12:2 MJ6:3 MJ6:4 MJ4:9 MJ5:8 MJ13:2 MJ14:1 MJ1:3 MJ1:1 MJ8:1

CJ30:1
ES1 ES2
UL DL SPL SSC 11
1 2 1 2 1 2 1 2 1 2 1 2
SMC
E-stop of control panel E-stop of motor/manual wheel switch Up final limit Down final limit Speed governor *Rope gripper 12

CJ30:2

PJ6:3 PJ6:4 PJ6:5 CJ1:2 CJ1:3 CJ1:1

JB
41 44
13 21 22 23 25 43
PJ1:1 PJ1:2 PJ2:1 PJ2:2 PJ3:1 PJ3:2 PJ4:1 PJ4:2

PIB
42 CJ16:2 CJ16:3 CJ16:4 CIB:1 CIB:2
CJ15:1 CJ15:2 CJ16:1

ES3 ES4 ES6 ES5


SPR SCB SWB SSG SCF
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 of back
2 1 2
*E-stop E-stop on cartop
E-stop 1 in pit E-stop 2 in pit Governor tension roller Safety gear *Car fixing switch door
*Car buffer *Counterweigh buffer
Optional Optional IOP

Safety switches in pit Safety switched on cartop

Landing vice door lock *Only use for double door lock function
MJS1:1 1SD 2SD nSD MJS1:2
1 2 1 2 1 2
KM1 02
KM1
301 3 4 5 6 MCB:X8 (D..07H)

Landing main door lock MJB-B


MJS2:1 1SD 2SD nSD MJS2:2 MJ8:2
1 2 1 2 1 2

MP2:2 JMS1
MJ1:6 301 3 4 MCB:X5 (D..07H)
M2 CJ9:1 CJ1:6

SDF
MS1 CJ9:2
1 2
Front car door lock MS1
MS1 CJ14:1
SDP
MS CJ14:2 CJ1:7 MJ1:7
1 2 KM 02
Back car door lock CJB-B MP4:4

MS
D..04H
MJ7:1
301
MJ7:2
302
MJ7:4
D..07H SA
MJ7:5
SB
MJ7:6
GND

MOD+

MOD+
MOD-

MOD-
COM

COM
24V

24V
MOD+

MOD-

COM
24V
G G G

HOS CN1 HOS CN1


CN1 HOS
RD
1 1
- +

JP1

JP1
2 2 1
Up arrival lantern/gong 1 2 1 2 1 2
3 3

JP1
2
4 4 FIR
GN 3
1 2
- +
1 FIR 1 FIR 4

JP2

JP2
2 2

Down arrival lantern/gong


1 2 1 2
3 3

4 4

1
24+ 1
1
24+ 1
1
24+ 1
2

JP2
2 2 2
UP
JP3

JP3
2 2 3
3 UP 3 UP 3
3 3 GND 4
GND 4 GND 4 4
4 4

1
24+ 1
1
24+ 1
1
24+ 1
2

JP3
2 2 2
DN
JP4

JP4
2 2 3
3 DN 3 DN 3
3 3 GND 4

MCTC-HCB-R1-SJ
MCTC-HCB-D2-SJ
GND 4 GND 4 4
MCTC-HCB-H-SJ
MCTC-HCB-F-SJ

4 4

MCTC-HCB-B-SJ
RD Up arrival lantern
HCB-SL-V
HCB-SL-H

A1 1
HCB-TFT

GN Down arrival lantern


A2 2

CN2
AM 3

B1 4

B2 5

BM 6
Optional

FOB FOB FOB

Note:
1.MCTC-HCB-H-SJ is vertical dot-matrix display.
2.MCTC-HCB-F-SJ is horizontal dot-matrix display.
3.MCTC-HCB-B-SJ is without display.
4.FLCD-H is horizontal 7-segment LCD dispaly.
5.FLCD-V is vertical 7-segment LCD display.
6.HCB-TFT is full color LCD.
tj{jTojiToVm HCB-SL
tj{jTojiTiTzq
JP2 JP1 Setting list of S1 Setting list of S2

C1
C2
C3
C4
C5
C6
B2
B1

A2
A1
BM

AM
F 0 1 2 3 4 1 2 3 4 5
1 ON OFF OFF OFF OFF

Set it to on when at 1th floor


OFF
ON
Use for testing
floor selection
2 OFF ON OFF OFF OFF
3 ON ON OFF OFF OFF
4 OFF OFF ON OFF OFF
5 ON OFF ON OFF OFF
6 OFF ON ON OFF OFF
7 ON ON ON OFF OFF
8 OFF OFF OFF ON OFF
HCB-SL-H HCB-SL-V 9 ON OFF OFF ON OFF
10 OFF ON OFF ON OFF
J2 11 ON ON OFF ON OFF
12 OFF OFF ON ON OFF

24V

COM
MOD-
MOD+
S1
13 ON OFF ON ON OFF
14 OFF ON ON ON OFF
S1
15 ON ON ON ON OFF
JP2 JP1 J1
16 OFF OFF OFF OFF ON
17 ON OFF OFF OFF ON
JP4
(DOWN) (UP)
JP3 CN1 Note: 18 OFF ON OFF OFF ON
JP4-DN JP3-UP

MOD+
MOD-
It can be used on landing and

COM
24V
19 ON ON OFF OFF ON
24V

COM
MOD-
MOD+

CN1
J1 20 OFF OFF ON OFF ON
in COP after setting DIP 21 ON OFF ON OFF ON
switch. 22 OFF ON ON OFF ON
Jumper Terminal and Application The right table shows how to
23
24
ON ON ON OFF
OFF OFF OFF ON
ON
ON
J1 set floor address. It can be 25
26
ON OFF OFF ON
OFF ON OFF ON
ON
ON
J2   used up to the 31th floor. 27 ON ON OFF ON ON
28 OFF OFF ON ON ON
Setting of HCB-H and HCB-F floor address: 29 ON OFF ON ON ON
30 OFF ON ON ON ON
1. Press button S1, HCB will display floor set. Floor address will increase 1 if 31 ON ON ON ON ON
press S1 once. the max. value of floor address is 40. If without pressing in 3 COP OFF OFF OFF OFF OFF

seconds, HCB will save the current display value as floor address. after flash Example:
twice, it saves successfully. COP ON ON
2. If HCB is used as floor indicator in COP, please set floor address 0.
1F ON ON
tj{jTojiTyXVkY

1RWH 10F ON ON
-LVXVHGIRUVDYLQJIORRULQIRUPDWLRQ
ZKHQMXPSLQJLWWKHXSDQGGRZQFDOOLQJ
EXWWRQLVXVHGIRUFKDQJLQJIORRULWLV
XVHGIRUFDOOLQJIXQFWLRQZKHQQR
MXPSLQJ7KHIORRUDGGUHVVFDQEHVHWE\XS
DQGGRZQEXWWRQZKHQMXPSHG-

UP
JP1 JP3 JP2 J1 CN1
Setting list of S1 HCB-TFT
Floor
bit1 bit2 bit3 bit4 bit5 bit6 bit7 bit8
1 ON OFF OFF OFF OFF OFF

LOGO setting
RS485 communication selection.
2 OFF ON OFF OFF OFF OFF

1234 567 8
3 ON ON OFF OFF OFF OFF

4 OFF OFF ON OFF OFF OFF

5 ON OFF ON OFF OFF OFF

ON
6 OFF ON ON OFF OFF OFF

7 ON ON ON OFF OFF OFF


S1
8 OFF OFF OFF ON OFF OFF

9 ON OFF OFF ON OFF OFF

10 OFF ON OFF ON OFF OFF

11 ON ON OFF ON OFF OFF

12 OFF OFF ON ON OFF OFF

13 ON OFF ON ON OFF OFF

14 OFF ON ON ON OFF OFF

15 ON ON ON ON OFF OFF

16 OFF OFF OFF OFF ON OFF JP1 JP2


17 ON OFF OFF OFF ON OFF CN1
JP3-UP JP4-DN

MOD+
MOD-
24V

COM
18 OFF ON OFF OFF ON OFF

19 ON ON OFF OFF ON OFF

20 OFF OFF ON OFF ON OFF

21 ON OFF ON OFF ON OFF

22 OFF ON ON OFF ON OFF

23 ON ON ON OFF ON OFF

24 OFF OFF OFF ON ON OFF

25 ON OFF OFF ON ON OFF

26 OFF ON OFF ON ON OFF


Note:
27 ON ON OFF ON ON OFF
It can be used on landing and in COP after setting DIP switch.
28 OFF OFF ON ON ON OFF
The right table shows how to set floor address. It can be used up to the 31th floor.
29 ON OFF ON ON ON OFF

30 OFF ON ON ON ON OFF

31 ON ON ON ON ON OFF
᪡㒉ㆅ OFF OFF OFF OFF OFF OFF

Example:
ON
COP

ON
1F

ON
10F
MCB:X12
MCB:X14
MCB:X16
MCB:X18

MCB:X13
MCB:X15
MCB:X17
MCB:X19
RTD
D..22H
RRD

MJB-B MP2 MP2 MJP:9 MJP:1


D33...006H D33...006H
6 8 10 12 7 9 11 13

301
302 302
MJ4 1 2 3 4 5 6 7 8 9 MJ5 1 2 3 4 5 6 7 8 9 MJ10 1 2 3 4 5 6 MJ10-1 1 2 3 4 5 6

G
RRD

RRD
302

302

302

302
RTD

RTD
301
1DSD
2DSD
3DSD

G
32
33
DSR
G
31
32
1USD
2USD
3USD

301
USR

UTF LTF
MJ10 1 2 3 4 5 6 MJ10-1 1 2 3 4 5 6
Governor switch
DA 1 2 3 4 5 6 7 8 9 DB 1 2 3 4 5 6 7 8 9
D..06H
301

31
32

301

32
33
1USD
2USD
3USD

1DSD
2DSD
3DSD
USR

DSR

1
SPL2
GR

2
G
G G

1
SPL1
GR

2
G
2

1
UL 3DSD
Overspeed governor Overspeed governor
1

2
GT GT

G G
2

USR 2DSD
1

Safety gear Safety gear


2

1USD 1DSD *Only used for car remote trip *Only used for blocks remote trip
1

2
2

2USD DSR
1

2
2

3USD DL
1

Upper terminal frame lower terminal frame


CJB-B
CJ4
CJB CJB CJB
ET1
01
CJ17 ET2
HLC1 502 02
CIB CJ15 1 ET3
03
35 1 2 505 D..16H
44 1 ET4
04
1 2
41 Illumination EV+
JAQ 2 05
2 EL Emergency illumination EV-
G CJ18 06
301 D..06H 3 Fan3
502 N5
07
D..09H 3 1 503
59 safety D..18H 2 1 507 08
TOP 4
2
Illumination switch in car 505
circuit CJ16 PG D..18H 09
AYS 42 Fan Fan switch in car 507
5 1 10
CP5 Alarm button AL AL1
AYX 43 EST1
501 11
6 2 D..16H 4 3
AL2
43 1 12
3 502
44 PG 3
4
Socket

CJ19
CP2
CJ9 301 1 ET1
SDF M2 1 LID 01
D..06H 1 2 2 ET2
02
LID
Front door lock MS1 2 ET3
D..16H 03
ET4
Emergency power 04
1 2 EV+
05
D..06H CJ3:6 EV-
06
Leveling inductor(LID)
*Bridge here if without Door lock
CJ20
D..09H 59
CJ14 1
D..06H SDP MS1 1 *Inspection fence switch 58
2
1 2
MS 2
(Option)
Back door lock
*Lighting-beam1: (With power box) *Lighting-beam2: (Without power box)

Front CJB Front CJB


Power CJ5 CJ6 CJ6
101 301(24+)
L 1 1 1
102 SDE1
N 2 2 2
G 302(-)
G 3 3 3
G
4 4
Signal CJ6
COM 301
1
NC SDE1 CTB CTB
2 CP3 CP3
3 CN3 CN3
5 5
X1 X1
4
6 6
X2 X2

Back Back
Power CJ10 CJ11 CJ11
101 301(24+)
L 1 1 1
102 SDE2
N 2 2 2
G 302(-)
G 3 3 3
G
4 4
Signal CJ11
COM 301
1
NC SDE1
2
3
4
Front door machine

Control CJ8 CP3 CN3


CJB-B_PCB MCTC-CTB-A
Open limit1 OLT1 1 5 X1 X1 1
COM2 301 2 6 X2 X2 2
COM1 CM1 3 7 X3 X3
MDF 3
Door-open1 OD1 4 8 X4 X4
3~M
4
Door-close1 CD1 5 CP4 CN4
Force close1 *FC1 6 1 BM BM 1
2 B1 B1 2
Power CJ7 B2
3 B2
3
101
L 1 4 B3 B3 4
102 CM
N 2 5 CM
5
G
G 3 6 C1 C1 6
7 C2 C2 7
8 C3 C3M 8
CP2 C3 9
*Back door machine(Option) ˜ 9 301

NKT12(1-1)B3
302 DM 10
Control CJ13 10 COM
D1 11
Open limit2 OLT2 1 U
301 D2 12
COM2 2 D
COM1 CM2 3
MDF
Door-open2 OD2 4 Cartop phone
3~M
Door-close2 CD2 5
Force close2 *FC2 6

Power CJ12 Up arrival Down arrival


101
L 1
102 CP3 3 4 5 6
N 2 BM
G 1 2 3 4
G 3
emergency
KEP-111D-03
CAN+
CAN-
302
301

CTB
301 CAN-
CAN+ 302

CN2
MCTC-CTB

A 24V 301

D..18H Illumination in car CAN+

CN2
CAN+
Communicate with MCB

CN5
AM CAN- CAN- D..13H
COM 302

1
24V 1
Weighing device AI P24V

MCTC-CCB
2 2
Ai 3 3

CN6
D..17H

CN2
4 4

CN7
M
5 5
6 6
7 7
Front lighting-beam X1 8 8 CCB
D..12H-2 Back lighting-beam X2

MCTC-HCB
Front Door-open limit X3 24V 24V
Back Door-open limit Mod+ Mod+

CN2
X4

CN1
P24V Mod- Mod-

CN3
D..12H-3
P24V COM COM HCB COP
Front Door-close limit X5
Back Door-close limit
X6
Full load signal

MCTC-HCB
X7 24V
Over load signal X8 Mod+

CN1
Mod-

COM1 COM HCB


BM
Door-open signal1 B1
Front door machine 1 24V 1
Door-close signal1 B2

MCTC-CCB
D..12H-3 2 2
Force close1 B3 3 3
COM2

CN2
4 4
CN8

CM
Door-open signal2 5 5
C1
CN4

Back door machine 6 6


Door-close signal2 7 7
D..12H-3 C2 Vice
Force close2 8 8 CCB
C3 COP

COM DM
Arrive gong Arrival gong signal(Up) D1
D..12H-3 Arrival gong signal(Down) D2

Note˖
Vise COP and back door are option.
MJB CJB CTB
MP3:1 MJ3:1 CJ3:1 CP3:1 301 CN2:1 CN1:1 24V

MP3:2 MJ3:2 CJ3:2 CP3:4 302 CN2:4 CN1:4 COM

D..07H
MP3:5 MJ2:1 CJ2:1 CP3:2 CAN+ CN2:2 CN1:2 MOD+

MP3:6 MJ2:2 CJ2:2 CP3:3 CAN- CN2:3 CN1:3 MOD-

MOD+
MOD-
COM

COM

COM
24V

24V

24V
SA
SB

SA
SB
CN1 JP1 JP1

MCTC-HCB-H-SJ

FLCD-V

CLCD-08
COP COP COP

Dot matrix Seven segment LCD Dot matrix LCD


(Option) (Option)
1F 2F 16F 1F 2F 31F

4
1

GND

GND

GND
24+

24+

24+
GND

GND

GND
24+

24+

24+

4
1

JP1

JP2

JP31
JP1

JP2

JP16
1 ATT 1 ATT
1 1 1 1

DOB
DOB

Door-open 2
2 2 Door-open 2
2 2
JP17 JP21 JP32 JP36
3 3
button 3 3 button 3 3
4
4 4
Attendant 4
4 4
Attendant

1 SCD 1 SCD
1 1 1 1

DCB
DCB

2
Door-close 2
2
JP18
2
JP22
Door-close 2
JP33
2
JP37
3 3
button 3 3
button 3 3
4 Attendant vary 4 Attendant vary
4
2-16 Floor 4
direction button
4
2-31 Floor 4
direction button
IND IND
1 1 1 1

DODB
DODB

2 2
Delay-closing 2
JP19
2
JP23
Delay-closing 2
JP34
2
JP38
3 3
3 3
button 3 3
Independent button Independent
4 4 4 4
running button running button
FIR2
1 1 1 1
FIR2
Non-stop Non-stop

NSB
NSB

2 2
2 2 2 2
JP20 JP24 JP35 JP39
3 3
button 3
MCTC-CCB-A CCB 3 button 3
MCTC-CCB-B CCB 3

4 4 Fireman switch 4 4

Fireman switch

CN1
CN2

CN1

8
1

8
1

CN7
CN7

MCTC-CTB-A CTB MCTC-CTB-A CTB

*:Use MCTC-CCB-B if more than 16 floors

*:Use both MCTC-CCB-A & MCTC-CCB-B if more than 31 floors

(Connect CN1 both of MCTC-CCB-A & MCTC-CCB-B)


1F 2F 16F 1F 2F 31F

4
1

GND

GND

GND
24+

24+

24+
24+

24+

24+
GND

GND

GND

4
1

JP1

JP2

JP31
JP1

JP2

JP16
1 1
1 1 1 1

DOB
Door-open
DOB

2
2
JP17
2
JP21
Door-open 2
2
JP32
2
JP36
3 3
button 3 3 button 3 3
4 4
4 4 4 4

1 1
1 1 1 1

Door-close

DCB
DCB

2 2
2
JP18
2
JP22
Door-close 2
JP33
2
JP37
3 3
button 3 3
button 3 3
4 4
4
2-16 Floor 4 4
2-31 Floor 4

1 1 1 1

2 2 2 2
JP19 JP23 JP34 JP38
3 3 3 3

4 4 4 4

1 1 1 1

2 2 2 2
JP20 JP24 JP35 JP39
3 3 3 3

4
MCTC-CCB-A CCB 4 4
MCTC-CCB-B CCB 4

CN1
CN2

CN1

8
1

8
1

CN8
CN8

MCTC-CTB-A CTB MCTC-CTB-A CTB

*:Use MCTC-CCB-B if more than 16 floors

*:Use both MCTC-CCB-A & MCTC-CCB-B if more than 31 floors

(Connect CN1 both of MCTC-CCB-A & MCTC-CCB-B)


QL2 FILTER

501
L L'
1 2
16A
Local power
502
N N'
3 4
30mA PE

PG
MJB
MP1:7 MP1:8 Jumping- Main board

MJ6:1 MJ6:2 MJ1:8 MJ1:9

PG PG

PG PG
PIB PJ6:1 PJ6:2 JB COP SC2(Fan)
G
36V(Option) CJ1:8 CJ1:9 CJB
36V(Option) SC1
(Illumination)
F1 CJ4:8 503
Option

220 220 505


CJ4:9
TP36 TP36
CJ4:10 507
36 36
ESP2 ESP1 CP5:1 CP5:3
501 502 CP4:9 CP4:10 CJ17:1 CJ17:2 CJ18:1 CJ18:2

501

502

507
502

505
503
PG EST2
EST1
3 SHL2 3
SHL2 CN5:1 CN5:3
4 4
PG A AM
HLP1 HLP1 HLC1 Fan3
3
SHL3 3
1 2 1 2 SHL3 1 2 2 1
Pit lighting 4 4 G
None when AC 36V HLT1 HLT1 HLCn Fan4

1 2 1 2 Auto off 1 2 2 1
top car lighting G
Pit inspection box None when AC 36V CTB car lighting
PG car Fan
Jumping-Car box
0&7&0&% 0&7&0&%

12 12

CN3 CN7 CN3 CN7


24V COM MOD+MOD- CAN+ CAN- Y1 M1 Y2 M2 Y3 M3 Y4 M4 Y5 M5 Y6 M6 24V COMMOD+ MOD- CAN+ CAN- Y1 M1 Y2 M2 Y3 M3 Y4 M4 Y5 M5 Y6 M6

Setting instruction of DIP switch Setting instruction of DIP switch


when simplex. when duplex.

0&%(J5) &7%RIPDLQ &7%RIYLFH 0&%(J5)


&7%(J2)
OLIW J2) OLIW J2)
ON OFF ON OFF ON OFF

Explain˖
1.Duplex connection is finished by local˗
2.When duplex control, to avoid effect each other, CAN+ of
two lifts'communication CANbus should be connected via Y5-M5.
And F5-30 should be set as 14. Please use twice twisted-pair cable.
3.setting instruction of CTB DIP
When simple, short right two pin of J2 on CTB
When duplex, short right two pin of J2 on CTB for main liftˈshort left two pin of J2 on
CTB for vice lift.
When duplex control, terminal resistance of J5 is nonuse.
4.parameter setting
main lift˖F6-07=2ˈF6-08=1DŽ
vice lift˖F6-07=2ˈF6-08=2DŽ
F6-07˖amount˗F6-08˖number of lift
Xb
Xa
~220V
L

~220
G3

PE

- 24 +
1
Q5
2

G
1 24+
5 CAN+
6 CAN-

MP3
CN7

MJB
NO.1
2 COM

G
MCTC-GCB-A

1 24+
5 CAN+
CAN-
MP3
CN9

6
MJB
NO.2

2 COM
G

1 24+ COM
5 CAN+ CAN-
6 CAN- CAN+
MP3
CN8
CN2

MJB
NO.3

2 COM 24+
G

1 24+
5 CAN+
CAN-
MP3
CN10

6
MJB
NO.4

2 COM
MCTC-MCB-A

Adaptor
CN9 CN7 CN3
CN2
:X23 :M4 :Y4 24+ :COM :MOD+ :MOD- RS232<->CAN

CANBUS

MJB-B
:16 :17 :18 :1 :2 :3 :4
MP2 MP3 *Optional: PC monitor

MJ20 MJ21
:1 :3 :1 :2

301 X23 M4 Y4 301 302 MOD+ MOD-

Adaptor Adaptor
RS485<->dry contact
BM B2 B1 AM A2 A1 RS485<->network

TCP/IP

FIRE_F1 FIRE_F2
Remote fire switch Monitor of RS485 COM HOS Fault Inspection Running
Remote fire return signal, output of relay
*Optional:dry contact monitor *Optional:network monitor
3 4

*Optional function:remote fire


Parameter setting: F5-23=23
*Dry contact output from other equipments
EOP (Emergency operation panel) Up running button
Emergency running switch
SUB1
SER
Remote reset Machine room lighting
E-stop on control panel SGR SHL1
ES1 MJP 3 4 3 4
D..28H2/2
Down running button 1 RRD
SDB1
8 301
Hoistway lighting
9 RTD Remote trip
SSL1
Re. D..009H SGT
3 4 3 4
D..28H2/2

IOP Plug
CIB
Only use for roomless
ℷ ᐌ -NORM ‫ ذ‬ℶ -STOP
1 2 3 4 5 6

44 JAQ 301 59 AYS AYX

ℷ ᐌ -NORM Ẕ ׂ -INS MJ10-1:1 Remote reset


Remote reset
MP1:11
MJP MJ10-1:4
SG SWG

1 RRD
Ϟ -UP MJ10-1:5 RRD 13 14
8 301 13 14
SG MP1:10 301
9 RTD
݀ ݅ -COM MJ10-1:2 RTD SWG
JAQ 44 301 59 AYS AYX 3 4
Remote trip
SMC MJ10-1:6
Up running button G 3 4
ϟ -DOWN
ES5 SUB2 Remote trip

1 2 1 2 3 4
Handle E-sotp SCM SDB2

3 4 3 4 3 4
Use for roomless and blocks governor
Handle inspection switch COM button Down running button

IOP top car inspection operation panel


Input and output terminal of MCB Machine phone, monitor phone
MP2 MP3
LID X09 X11 DSR 1DSD 2DSD 3DSD X22 M4 301 MOD+ CAN+ CT1 CT3

JMSF X10 USR 1USD 2USD 3USD BZF X23 Y4 302 MOD- CAN- CT2 CT4
1 3 5 7 9 11 13 15 17 1 3 5 7 9
6 8 10 12 14 16 18 2 4 6 8 10

MP1 MJP
01
1

Feedback Communication Governor


Vice safety of doorlock of HCB control 301 RRD
DANGER!!! HIGH VOLTAGE

02

1
2

KAQ1 KM MJ7 MJ10 RTD 58

2
03 Operate
3

10
01 ADS

3
301 MOD+ 302 302

4
1

4
04 handle
4

ADX

4
302 MOD- RTD RRD

5
2
5
2
101 11 X09

11
5

5
GND GND

6
3

6
Power 24 X10

12

6
102
6

42 X11

13

7
501 1 2 3 4 5
7

Wiring of main panal TA R S T 0 G


502
8

GND MJB MP4


9

ZQ2

6
Doorlock Wind Thermal Brake Brake 1 2 3
301 Governor
10

of hall switch resistor


feedback output ZQ1

5
MJ8 protection TB U V W
302
11

MJ12 MJ13 MJ15 MJ16 MJ18 MS

4
JAQ
1

JAQ 1 2 3 4 5 6 7 8 9 10 11

3
12 33 301 301 ZQ1
1

1
MJ14 M1
2

34 13 34 MHP BZF ZQ2 JAQ1F TC Xa Xb *LI *NI *LO*NO *H1L *H2L *HN *s1 *t1

2
2

2
Rope
1

GND
3

gripper MHP
35

1
2

switch

Up switch shelf Down switch shelf Inspection box of pit MP12


MJ4 MJ5 MJ6 RV3

3
MJ20
301 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7
1

RV2 Put apart

2
1USD 2USD 3USD USR 1DSD 2DSD 3DSD DSR 501 502 13 23 31
Put apart X22 to travel
2

RV1 cable
1
to input 301 GND 31 32 301 GND 32 33 CT1CT2CT3 CT4 GND
X23
3

6 7 8 9 6 7 8 9 8 9 10 11 12 13
MJ22
COM Communication
3

MJ21
Travel cable
M4 MJ1 MJ2 MJ3 MOD- monitor
2

Put apart
1

1 2 3 4 5 1 2 3 4 1 2 3 4 5 6 7
to output Y4 JAQ 35 301 302 ADS 58 ADX LID YPX MOD+
1

42 101 102
2

CAN+ CAN- GND

M2 MS 501 502 CT1 CT2 GND CT3 CT4 RV1 RV2 RV3

6 7 8 9 5 6 7 8 9 10 11 12 13
PJ6
PT1 501 PJ1 PJ2
PT2 502

PT3 13
1 2 21 22 22 23 G
23

PT4 31

GND

8 1

9 2 PJ3 PJ4
10 3

4 G G
1 2 3 23 25 25 31
11 5

12 6

13 7
Inspection fence Saftey switch Put apart to travel cable Lighting power
CJ20 CJ16 CPR CP5

59 58 42 43 43 44 RV1 RV2 RV3 501 502 G

1 2 1 2 3 4 1 2 3 501 502 G
1 3 5
Cartop panel CTB
2 4 6
Cartop inspection CP4
CIB Catch block LID
4 5 6 503
501
59 ADS ADX CJ15 CJ19 Wiring of cartop FC2
44 JAQ 301 35 42 G 301 LID CD2
CJB
OD2
1 2 3 1 2 3 1 2
CM2
FC1
Front lighting-beam Front doorlock Back lighting-beam Back doorlock CD1
CJ5 CJ9 CJ10 CJ14 OD1
CM1
101 102 G M2 MS1 G 101 102 G MS1 MS G
1 2 3 1 2 3 1 2 3
CJ6 CJ11 CP3
Front door machine Back door machine
301 SDE1 302 G 301 SDE2 302 G OLT2
1 2 3 4 CJ8 1 2 3 4 CJ13 OLT1
4 5 6 SDE2
SDE1
CJ7 OD1 CD1 FC1 CJ12 OD2 CD2 FC2
302
101 102 G OLT1 301 CM1 101 102 G OLT2 301 CM2 CAN-
1 2 3 2 3 1 2 3 1 2 3 CAN+
1
301
CJ4 Cartop lighting
1 2 3 4 5 6 7 Car fan
Control box CJ18 CJ17 Emergency power
CT1 CT2 CT3 CT4 EL+ EL-
in car 502 507 G 502 505 G CP2
503 505 507 AL+ AL- G
1 2 3 1 2 3
8 9 10 11 12 13 302
301
AL-
Travel cable AL1
CJ1 CJ2 CJ3 EL-
1 2 3 4 5 1 2 3 4 1 2 3 4 5 6 7 EL+
CT4
JAQ 35 42 101 102 CAN+ CAN- 301 302 ADS 58 ADX LID CT3
CT2
M2 MS 501 502 CT1 CT2 CT3 CT4 RV1 RV2 RV3 CT1
6 7 8 9 5 6 7 8 9 10 11 12 13
MCTC-CCB-A/MCTC-CCB-B

JP1 JP2 JP31 FC-098E/FC-198E


:1 :2 :3 :4 :1 :2 :3 :4 ...... :1 :2 :3 :4
12V :1_+12V
LED+ 24V K_IN LED- 0V :2_GND

:3_NO
:4_COM
:5_NC
:6
:7
:8
:9
SBP :10
1 2 :11
1 2 3 4
Button terminal Access control bypass switch :11

:1 :2 :3 :4 :1 :2 :3 :4 ...... :1 :2 :3 :4

1F button 2F button 31F button

Access control system scheme 1: All buttons are contrlled in car together
1. One )&()&( controller and one bypass switch should be installed in car.
2. One relay's ON in )&()&( controls all button's COM Except main floor, button
for main floor is not controlled. Just suppose floor 1 is main floor in the diagram.
3. If no available access control card is used, the relay in )&()&( will not close
(Pin3-Pin4). And all buttons on COP will be unavailable.
4. If available access control is used, the relay in )&()&( will close (Pin3-Pin4).
Then, all buttons on COP will be available in 10 seconds.
5. The button for main floor is not controlled. So, this button is always available.
6. This access controller can be disabed by SBP (accsee control bypass switch). If SBP is
closed,access controller will be disabed, so all buttons are availabe .
Buttom/top IC card controller Middle IC card controller

Bottom/top landing display board DTIC controller I Middle landing display board DTIC controller I

Up button(bottom)/Down button(top) port Up button port Down button port


:1 :2 :3 :4 301 :1_24V :1 :2 :3 :4 :1 :2 :3 :4 301 :1_24V
302 :2_GND 302 :2_GND
LED+ 24V K_IN LED- LED+ 24V K_IN LED-

:3_JDQ1 :3_JDQ1
:4_JDQ2 :4_JDQ2
:5_485-A :5_485-A
:6_485-B :6_485-B
:7_XF-1 :7_XF-1
:8_XF-2 :8_XF-2
:9_485-A2 :9_485-A2
SBPn SBPn
:10_485-B2 :10_485-B2
1 2 1 2
1 2 3 4
Button terminal
IC bypass switch IC bypass switch

:1 :2 :3 :4 :1 :2 :3 :4 :1 :2 :3 :4

IC card reader IC card reader

Up/Down button Up button Down button

IC CARD SCHEME3: Hall buttons enable/disable singly


1. 1 DTIC controller, 1 IC card reader and 1 bypass switch should be installed in every
FOB.
2. For top floor and bottom floor, no need to push the button after used IC card. For middle
floors, after used IC card, need to push the up/down button.
3. if no abailable IC card is used, the relay in DTIC will not close (Pin3-Pin4). Such as,
up/down buttons on FOB will be unavailabe.
4. If avaiable IC card is used, the relay in DTIC will close (Pin3-Pin4). Then, up/down
button on FOB will be availabe in 10 sencons.
5. This IC card funtion can be disabled by SBPn (IC card bypass switch). If SBPn is
closed,
DTIC will be disabled, so up/down buttons are available at any time. n means floor number.
Buttom/top IC card controller Middle IC card controller

Bottom/top landing display board JT-04E controller Middle landing display board JT-04E controller

Up button(bottom)/Down button(top) port Up button port Down button port


301 :1 24V+
:1 :2 :3 :4 :1 :2 :3 :4 :1 :2 :3 :4 301 :1 24V+
302 :2_24V-
302 :2_24V-
LED+ 24V K_IN LED- :3_IN+ LED+ 24V K_IN LED-
:4_IN-
:5_OUT1_1 :3_IN+
:6_OUT1_2 :4_IN-
:7_OUT2_1 :5_OUT1_1
:8_OUT2_2 :6_OUT1_2
:7_OUT2_1
1 2 3 4 SBPn
SBPn :8_OUT2_2
Button terminal 1 2
1 2
:1 :2 :3 :4 IC bypass switch
IC card reader IC bypass switch

IC card reader

:1 :2 :3 :4 :1 :2 :3 :4

Up/Down button

Up button Down button

IC CARD SCHEME3: Hall buttons enable/disable singly


1. 1 JT-04E controller, 1 IC card reader and 1 bypass switch should be installed in every
FOB.
2. For top floor and bottom floor, no need to push the button after used IC card. For middle
floors, after used IC card, need to push the up/down button.
3. If no abailable IC card is used, the circuit in controller will not close. Such as,
up/down buttons on FOB will be unavailabe.
4. If avaiable IC card is used, the circuit in controller will close. Then, up/down
button on FOB will be availabe in 10 sencons.
5. This IC card funtion can be disabled by SBPn (IC card bypass switch). If SBPn is closed,
IC card will be disabled, so up/down buttons are available at any time. n means floor number.
QL1 power box

User power
L

for lighting
1 2
~AC220 16A

3 4
N 30mA

Fire emergency elevator (option) SSL1


HLn
301

13

23
A1
KF2

14

24
A2
HL3

MCB
HL2
M4

MP2:17 MP2:18
Y4

MJB-B

SSL2
302
D..21H HL1

Remote fire
*shaft lighting is optional

*only use for power box


QL1

User power
L

for lighting
501
Xa
1 2
~AC220 16A QL2:2 (D..18H)
502
Xb
3 4
N 30mA

Firefighter(option) HN
SSL1
HLn
301 D..21H ESC1
H1L
L N
H2L G
13

23

A1

43
KF2
KYX
14

24

A2
HL3
3

44
SHL1
MCB 4
M4
Y4

HL2
D..21H

302 HCC Fan2


L N L N

SSL2 Controller lighting G


Fan
HL1

*shaft lighting

hoistway lamp breaker hoistway lamp

Q8 SL
+12V T3 T4 0V
1 2

*only use for no power box


MCTC-SCB-A

301 24V

302 COM

FL1
MP12:1 FL1_up relevel input signal

FL2
MP12:2 FL2_down relevel input signal
MCTC-MCB
M3

Y3 SY_door lock short contactor output

X01_up level MP2:1


YPS

X02_door zone SX1_door zone input signal

X03_down level MP12:3


YPX

X08_ᇕ 䮼 ড 作 SX2_door lock short contactor feedback output

JAQ MP4:3 SO1_door lock circuit

MS MP4:4 SO2_door lock circuit

only use for relevel function