Design Pressure Estimation

The document describes the design pressure estimation for a vacuum buffer tank. It provides details on the operating fluid, densities, pressures, temperatures, heights, and calculations to determine the maximum allowable working pressure and internal design pressure for the tank.

Uploaded by

miteshpatel191
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views1 page

Design Pressure Estimation

The document describes the design pressure estimation for a vacuum buffer tank. It provides details on the operating fluid, densities, pressures, temperatures, heights, and calculations to determine the maximum allowable working pressure and internal design pressure for the tank.

Uploaded by

miteshpatel191
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DEVCHAND ENGINEERS PVT.

LTD
Works: A-4/5, Sachin Udyog Nagar Sahakari Mandli Ltd., opp: Village - Vanz Dandi Road, Sachin, Dist: Surat 394230
EQUIPMENT DESCRIPTION: VACUUM BUFFER TANK
EQUIPMENT TAG NO: V-2105 Job No : DEPL-U-001

DRAWING REFERENCE: DEPL-U-021-001_R0 Page 8

Design Pressure Estimation Document No : DEPL-U-DSG-001


Revision No : 0
Fluid Air + TFE
Density of operating Fluid ρ 26.1 Kg/m3
Operating Pressure Internal Po 0.50 MPa (g)
Full Vacuum External -1.0 MPa (g)
Operating Temperature To 45 to 60 oC
Design Temperature Ts 75 oC
The internal design pressure given by Owners (Client) is 0.343 MPa (g)
Internal diameter of Vacuum Buffer tank 1100 mm
Maximum height of Content in Vacuum Buffer Tank 2252 mm
MAWP has been assume to be same as design pressure as per UG-99(b) Note 34. 0.3432 MPa (g)
As per UG-98 the MAWP for a vessel is the maximum internal pressure at the top of the vessel:
Hence, Internal design pressure for calculation as per UG-21 = MAWP + Static Head
Evaluation of Static Head for Operating Fluid: (Reference: Drawing no. DEPL-U-021-001-R0)

MAWP Height of Static Head


Component
MPa (g) (meter)
Top Nozzle N2, N3, N4 0.343 0.158
Top Head 0.343 0.483
LI Nozzle L1 0.343 0.633
LI Nozzle L1 0.343 1.833
Shell 0.343 2.083
Bottom Head 0.343 2.408
Bottom Nozzle N1 0.343 2.566

Hence, maximum operating Fluid head h 2.566 m


Density of operating Fluid (ρ) ρ 26.1 kg/m3
Pressure due to static head Ps = h x ρ 67.0 kg/m2
0.0067 kg/cm2
0.0067 / 10.19716 = 0.0007 MPa (g)
Pressure due to static head is very small and hence ingnored.
The Internal design pressure considered for calculation,
P= MAWP + Ps
0.3432 + 0.0000 0.3432 MPa (g)
The Internal design pressure rounded of for calculation, P= 0.3432 MPa (g)