HV Circuit Breakers
HV Circuit Breakers
HV Circuit Breakers
st
HV Circuit Breakers
customers
st Siemens Fills The Order
Breaker products:
− Dead tank breakers
− Live tank breakers
− Vacuum breakers
− GIS
− Circuit switchers
− Reclosers
PTD H 3 World Headquarters in Berlin
− MV and HV Arrester
Products
customers
st Over 30 Years Experience in
Jackson
1973 – Plant opened as Allis Chalmers (Moved from Boston)
− Began production of SDO, BZO, GHO, TDO Breakers
1978 – Became Siemens Allis
1982 – Replace GHO with 3AT
1985 – Purchased SP Breaker from Westinghouse to
replace TDO
− Began Voltage Regulator Production
1992 - Began SPS
1994 – Began Mfg. of TCP Design to replace BZO
− Began Mfg. of SDV to replace SDO
1995 –Began Candlestick type Circuit Switcher production (CPV)
1996 – Replaced TCP Design with SPS1-145
1998 – Replaced SP / SPS / SPS1 with new SPS2 design
1999 - Replaced TCP-245 with SPS2-245
2000 – Replaced CPV with new CPV2 Design
Present – SPS2, CPV2, Single and Three Phase Voltage Regulators,
Reclosers, Surge Arrestors
customers World Wide Dead-Tank Breaker
st Center Of Competency
Design Commonality
Minimal Maintenance
No Field Adjustments
Retrofitable Design
Added Value
customers
st SPS2 Circuit Breakers
Available 15kV – 245kV
Proven, global components
− FA2 and FA4 Mechanisms
− 3AP arc-assist interrupter
Up to 68kA at 245kV
Up to -30 º to 55 º C without
tank heaters
customers Siemens Experience : The 3AP
st
interrupter
Superior performance
− 18 full faults
− 6000 operations at 6kA
− 10,000 mechanical operations
Up to 18 current transformers
Metering / Relaying accuracy CT’s
Extra creepage bushings
Composite bushings
High seismic withstand
External pull to trip handle
Relays for reclosing or non-reclosing applications
customers
st New / Future Offerings
− Synchronous Close
Minimising of overvoltages
−Decreasing of the dielectric stress -> lower ageing
−Substitution of closing resistors -> higher reliability
customers
st
Circuit Breaker Type SPS2X_US
Porcelain
bushing
8240
(324,4)
Current
transformer
Circuit-breaker
3570
(140,5)
Spring
operator
customers
st Platform 550 kV Circuit-Breaker 3AP2/3 Dead-Tank
5750
(226,4)
Composite
bushing
8570
Current (337)
transformer
Circuit-breaker
3540
(139,4)
Spring
operator
customers Platform 550 kV Circuit-Breaker
st 3AP2/3 Dead-Tank with Closing Resistors
Closing resistor
Filter material
customers
st
Surge Arresters
Station and Distribution
customers Surge Arresters
Introduction and General Information
st
Experience of more than...
75 years with surge protective devices
25 years with metal-oxide surge arresters
15 years with polymer (silicone) insulated high-voltage arresters
Monitoring
Devices
3EX5 060/62 3EX6 040 3EX5 030 3EX5 050
3EL2 3EP4 3EP2 3EP3 3EQ1 3EQ4 3EQ3 3ES2 3ES5 3ES7,
3ES9
Column of MO resistors
totally surrounded
by silicone
„Cage Design“
customers Silicone Housed Surge Arresters for High Voltage
st Type 3EL – Design Principle: „Cage Design“
customers Silicone Housed Surge Arresters for High Voltage
st 3EL - Comparison of Cantilever Strength
3EQ4
up to Um = 550 kV
3EQ1
up to Um = 362 kV
„Tube Design“
customers Silicone Housed Surge Arresters for High Voltage
st 3EQ – Design Principle: “Tube design”
2
3
SIEMENS Competition
Example left side (SIEMENS):
3EQ with 2 segments for up to 550 kV system voltage
more stability
= higher mechanical cantilever strength
less segments to mount
= less installation time
--> less installation costs
less danger of moisture ingress between flanges
better voltage distribution
all in all:
The lower the number of segments per arrester stack
the better the electrical and mechanical performance is.
customers Arrester Monitoring Devices
st Types 3EX6 040, 3EX5 030, 3EX5 050, 3EX5 060/62
Control Spark Gap Surge Counter Surge Counter with Arrester monitor with
leakage current meter remote indication
3EX6 040 3EX5 030
3EX5 050 3EX5 060/062
customers
st
Voltage Regulators
customers
st
+ / - 10 % Regulation
in 32 Steps
Equipped with
Controller (MJ-XL)
customers
st Voltage Regulator - Applications
Pole Mounted
Platform Mounted
Substation
customers
st Three Phase Regulators
• Functionality
• Advanced Metering
• Superior Data Logging
• Intuitive User Interface
• Powerful Communications
• Continuing Enhancements
customers
st Advanced Metering
• Instantaneous Voltages, Current, & Power
• Demand Voltages, Current, & Power
• Minimum/Maximum Time Stamps to the second
• Energy Readings
• Support for 3-Phase Calculations
• Harmonics Displays to the 31st harmonic
customers
st Superior Event Logging
• Multiple “Event Types”
• Tap Change, Tap at Neutral, Tap
raise/lower to NN position, VLC/VRC
active, Power Flow reversal,
Configuration change,
• Tap Tracking
• Remote Control
• Controller Error
customers
st Intuitive User Interface
• Menu-Driven