Masibus 409-4IN R0F 0716 Large Display Indicator

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

409-4IN

Large Display Indicator

Model 409-4IN is the large display Indicator which can be monitored


up to distance of 160 feet (50m). Its large digit facilitates process value
Features
to be monitored across wider geographical area in plant. It has most
advanced features for monitoring and communication of process 4” (100mm) Large LED Display
status. 21 selectable input types (TC, RTD, mV, mA, V, ? )
Transmitter Power Supply
Model 409-4IN accepts 21 different industry standard inputs with high RS485 serial communication (optional)
accuracy of 0.1% to measure temperature, pressure and other process PV write facility via Serial input
variables. It is easy to operate and configuration is user friendly. CJC Programmable retransmission output (optional)
compensation for thermocouple input is done through software for Two programmable alarm outputs (optional)
higher accuracy.
Available with 19” Rack & IP65 Wall mount enclosure
Display brightness control
It can be interfaced with SCADA/PLC using optional RS485
Serial RS485 Input (Modbus Slave Read/Write)
communication and analog retransmission output for process
Input Scalability for Linear input type
automation. It has two-way communication facility allowing user to
Square Root Extraction for linear input type.
read and write PV over Modbus between any Master device and
Indicator. Selectable Digital Filter 0-60 Sec

Alarm can be configured for two set points which are indicated on front
Status LEDs. This Indicator has SMPS power supply for smooth and
reliable performance. It is also equipped with transmitter power supply.
Applications
Temperature & process indication
Model 409-4IN utilizes its unique feature of LED brightness control Pressure/ Level/ Flow Monitoring
which enables plant engineers/ operators to adjust intensity of Plastics molding/extrusion temperature monitoring
controllers' LED display in order to achieve comfort for eyes. Heat treatment - furnace temperature monitoring
Weighing platform
Model 409-4IN is equipped with advanced functions like digital Remote Process Supervision
filtering, password setting, input and output protection and square root
function for optimum process functionality.

www.masibus.com [email protected]
TECHNICAL SPECIFICATIONS
Input Power Supply
Thermocouple (E, J, K, T, B, R, S), RTD (Pt100), Supply Voltage 85-265VAC/ 125-300VDC
Input Type
Current, Voltage, Resistance Power consumption <10 VA
Display Range Table-1 Isolation (Withstanding voltage)
Accuracy ±0.1% of FS ± 1Digit • Between primary terminals* and secondary terminals**: At least 1500 V AC for 1 minute
• Between primary terminals* and grounding terminal: At least 1500 V AC for 1 minute
ADC Resolution 17 bits • Between grounding terminal and secondary terminals**: At least 1500 V AC for 1 minute
Display Resolution 0.1°C/ 1 Count • Between secondary terminals**: At least 500 V AC for 1 minute
* Primary terminals indicate power terminals and relay output terminals.
Sampling Rate 4 Samples/Sec ** Secondary terminals indicate analog I/O signal and Communication O/P.
CJC Error ±2.0 °C Insulation resistance: 20M? or more at 500 V DC between power terminals and grounding terminal.
Sensor open All inputs except 0-5V, 0-10V, ± 10V, 0-20mA Enclosure Protection IP20 IP65
Sensor Burnout current 0.5 uA (Approx.) 19” Rack / Panel Mount
Mounting Wall Mount
RTD excitation current 0.8 mA (Approx.) /Wall Mount
NMRR > 40 dB Enclosure material MS Powder Coated MS Powder Coated
CMRR > 100 dB Dimensions(in mm) 440(W)x175(H)x70(D) 500(W)x300(H)x120(D)
< 100ppm for Input to Display Panel Cutout(in mm) 444 (+0.8) x175 (+0.8) NA
Temp-co
< 150ppm for retransmission output Weight 3 Kg (Approx.) 8.3 Kg (Approx.)
> 1M? for TC, 0-2V, 0.4-2V, 0-75mV, ± 75mV Terminal Cable Size 2.5mm² 2.5mm²
Input Impedance
> 840 k? for 0-5V, 1-5V, 0-10V, ±10V 2 Nos. Clamp, 4 Nos. Wall Mounting
Max Voltage 20VDC Standard Accessories 2 Handle for 19” Rack / Bracket. 3 Nos. of PG 13
Display & Keys Panel Mount Gland (For Cable entry).
Process Value 4" Four-digit Seven segment Red LED Environmental
Status Indication 4 Red LED's for (Alarm and Tx/Rx) Operating temperature 0-55 °C
Keys Menu, Enter, Increase, Decrease Storage temperature 0-80 °C
Output Humidity 20-95 %RH non-condensing
Alarm Output (Optional) Table-1: Display Range
Relays 2 Nos. Input Type Range
Type Single Change over (C, NO, NC) E -200 to 1000°C
Rating 5A @ 230VAC / 30VDC J -200 to 1200°C
Retransmission Output (Optional) K -200 to 1350°C
Current 0/4-20mA @500? Max. Thermocouples T -200 to 400°C
Voltage 0/1-5V, 0-10V @2K? Min. B 450 to 1800°C
Accuracy 0.25% of FS R 0 to 1750°C
Communication (Optional) S 0 to 1750°C
Interface RS485 (2 Wire) RTD Pt-100 -199.9 to 850.0°C
Protocol Modbus-RTU 0 - 400?
Resistance -1999 to 9999
Baud rate 4800, 9600, 19200, 38400 0 - 6000?
Transmitter Power 1-5V /4-20mA
24VDC (±10%) @50mA 0-5V/0-20mA
Supply
0-2V
0.4-2V
Linear ±10 V -1999 to 9999
0 - 10 V
-10-20mV
±75 mV
0-75mV
Serial (RS485) PV write Facility 1999 to 9999
ORDERING CODE
Model Input Type Communication Relay Retransmission O/P Mounting (Protection)
409-4IN 1 E N None N None N None P0 19” Rack (IP20)
2 J Y RS485 Y 2 Relays C 4-20mA W0 Wall (IP20)
3 K D 0-20mA W1 Wall (IP65)
4 T E 1-5V
5 B F 0-5V
6 R G 0-10V
7 S
9 Pt-100
C 4-20mA
D 0-20mA
E 1-5V
F 0-5V
G 0-10V
H 0-2 V
I 0.4 – 2V
R ±75mV
U 0-75mV
V 0-400?
W 0-6000?
M Serial RS485# When Serial input type is selected, RS485 o/p needs to be selected
#

S Special

Head Office: Masibus Automation And Instrumentation Pvt. Ltd.


All specifications are subject to change without notice
B-30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India.
due to continuous improvements.
Tel: +91 79 23287275-77, Fax: +91 79 23287281.
Doc. Ref. 409-4IN/R0F/0716
E-mail: [email protected], Web: www.masibus.com