0% found this document useful (1 vote)
439 views3 pages

Private: Total Demand Calculation: Al Muna Gardens For Each Villa Fixtures Type

The document calculates the total water demand for a residential villa development called Al Muna Gardens consisting of 122 villas. It determines the fixture units and water demand in gallons per minute and cubic meters per hour for each villa based on fixtures. It then calculates the total daily water demand in liters and gallons for a single villa and for the entire development, assuming 5 occupants and 400 liters per day per occupant. The overhead water tank size recommended for each villa is 600 gallons.

Uploaded by

EMAAD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
439 views3 pages

Private: Total Demand Calculation: Al Muna Gardens For Each Villa Fixtures Type

The document calculates the total water demand for a residential villa development called Al Muna Gardens consisting of 122 villas. It determines the fixture units and water demand in gallons per minute and cubic meters per hour for each villa based on fixtures. It then calculates the total daily water demand in liters and gallons for a single villa and for the entire development, assuming 5 occupants and 400 liters per day per occupant. The overhead water tank size recommended for each villa is 600 gallons.

Uploaded by

EMAAD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

TOTAL DEMAND CALCULATION : AL MUNA GARDENS FOR EACH VILLA

Fixtures type : private


Weight in Fixture units Total weight in fixture units
FIXTURES Quantity
Cold Hot Total Cold Hot Total
Water closet (flush valve) 6 0 6 0 0 0 0
Water closet (flush tank) 4 0 4 5 20 0 20
Water Bidet 1 1 2 0 0 0
Hose for W.C 1 1 2 5 5 5 10
Lavatory (& H.B., J.S.) 0.75 0.75 1 0 0 0 0
Service sink 1.5 1.5 2 0 0 0 0
Shower 2 2 2 4 8 8 8
Bath tub 2 2 2 1 2 2 2
Kitchen sink 1.5 1.5 2 1 1.5 1.5 2
Dishwashing machine 0 1 1 1 0 1 1
Laundry 1.5 1.5 2 1 1.5 1.5 2
Ablution (Public) 1 1 1.5 0 0 0
Urinal (1" flush valve) 10 0 10 0 0 0
Urinal (3/4" flush valve) 5 0 5 0 0 0
Urinal (flush tank) 3 0 3 0 0 0
Total Fixture Units 38 19 45
WATER DEMAND ( GPM ) 23.9 GPM 13.4 GPM 27.0 GPM
WATER DEMAND ( m3/ h ) 5.42 m3/h 3.04 m3/h 6.13 m3/h

Assuming Peak factor : 1.5


Duration : 60 min

The mean demand 18.0 gpm (mean demand = peak demand / peak factor )
Overhead tank size 540 gallon ( Overhead tank size = (peak demand - mean demand) x duration }
2.04 m3

Transfer pump capacity 18.0 gpm ( Transfer pump capacity = mean demand , Assuming one pump
4.09 m3/h running & one standby)
1.14 l/s
PROJECT NAME- AL MUNA GARDENS 122 VILLAS
MEP CONTRACTOR - SEMEC SPECIALIZED PROJECTS LLC
DATE - 22/DEC/2021
TYPE OF LOAD TOTAL NOS OF PERSON LITERS/DAY/PERSON
OCCUPANTS 5 400
OCCUPANTS /
FACILITY 20 400
BUILDING
TOTAL WATER DEMAND FOR 1 DAY (LITRE) FOR EACH VILLA
TOTAL GALLONS FOR DAY FOR EACH VILLA
TOTAL WATER DEMAND FOR ONE DAY (LITRE) FOR ALL 122 VILLA +
FB
TOTAL GALLONS FOR DAY FOR ALL 122 VILLA + FB
ASSUMED OVERHEAD WATER TANK FOR EACH VILLA - 600GALLONS
WATER DEMAND (LITRE)
2000

8000

2000
530

252000

66579 66578.5997358