AE Relay Product Introduction

Examples may be changed without notice Official Website:


Paper of this manual can be recycled http://www.aeg-imc.com Distribution and Control
Print No.: 2801641 Hotline: German Quality – Centennial
Version Number: 2019ZB003 400-820-5234 Heritage
GALAXY 3AE Series GALAXY 3AE Series
Protective Relay Protective Relay

Product Profile 3AE Ordering Information


GALAXY 3AE series protection and management device includes two categories of 3AEF151 feeder protection
and 3AEM149 motor protection, the new generation of protection device integrating computer measurement
and control that is aimed to adapting to the development demand of automatic technology of substations. It adopts
Function Content
a structure of double CPU, which can complete circuit protection, measurement, control, remote
communication and other functions. Normally open contact
SS1 User-defined Normally close contact (for device fault or
Product Features power failure) (Default setting)
·Highly reliable, maintenance-free, high accuracy, calibration-free. Passive or as DI input (Default setting)
·Anti-vibration, wide-range temperature, dust sealing and “one-to-one”design principle, which can be installed on Energy Pulse Input
Active
switch -gears separately, or be centralized on one panel.
Ungrounded system 0.02-1A (Default setting)
·Adaptable to adverse on-site operation environment, with EMC up to standard of Class Zero Sequence Current
·Wide-range working power supply of 100~250 VDC or 85~276 VAC, 50Hz (optional for DC48V). Grounded system 0.5-100A
·Large-sized white screen, Chinese interface, which can visually describe dynamic single line diagram and bar chart of load. Current 1A (Default setting)、5A
·The user can perform panel operation with multi-function buttons conveniently. Voltage 100V (Default setting)、400V
·Two sets of constant values for manual and automatic switches. Product Code 3AEF151、3AEM149
·Be capable of measuring current, voltage, power, power factor, energy and other parameters.
·It has one RS485 communication interface for information transmission, one RS232 communication
interface on front panel for test, as well as communication protocol MODBUS-RTU, etc.
·It has 8 channels of passive digital input, 4 channels of pulse input (can be defined as digital input),
6 channels of digital out-put, among which most digital inputs and outputs can be defined and programmed by the user.
·One analog output, for DCS system.
·Be capable of recording 100 event logs that will not loss when power is off, with 1ms resolution.
Technical Parameter
Parameter 3AEF151 3AEM149
Power Supply 100~250 VDC or 85~276 VAC, 50Hz (optional for DC48V)
Measurement All power measurement(voltage、 current 0.5%,power、power factor 1.0%)

IO Configuration 8DI、6DO、4PI、1AO
Three-phase three-step current protection One-step zero sequence current protection、
、Two-step zero sequence current Overvoltage protection、Blocking protection、
protection、Overload protection、 Thermal protection、Negative sequence current
Protection
Overvoltage protection、Under voltage protection、Undercurrent protection、
protection、Anomaly detection and alarm No-voltage restart function、Anomaly detection
for switch status、Three-phase no voltage and alarm for switch status、Three-phase no voltage
Monitoring Event log (capacity: 100 logs; resolution: 1ms)
Debugging Interface:RS232 communication、RS485 communication
Communication
(MODBUS-RTU communication protocol)
Technical Parameter
GALAXY 2A 2 E Series Parameter 2AEG150(F、M、T、B、C) 2AET(M)387 2AEU127
Protective Relay Power Supply 110/220VDC or VAC (+15%,-20%)
Measurement All power measurement(Voltage、Current 0.2%,Power、Power Factor 0.5%)
IO Configuration 16DI (110/220VDC or VAC)、10DO、1AO、3AI
Overload protection、Negative Overload protection、 Overload protection、Negative
sequence current protection、 Negative sequence sequence current protection、
Zero sequence current protection、current protection、Zero Zero sequence overcurrent
Overcurrent protection、 sequence current protection protection、Overcurrent
Product Profile Protection Overvoltage protection、 Overcurrent protection、 protection、Overvoltage
Galaxy 2AE series protection and management device is developed by taking full advantage of AEG’s centennial Overheating protection、 Overvoltage protection、 protection、Unbalanced
practice and technical accumulation in the field of power system automation, which applied computer software Unbalanced voltage protection、 Low-voltage protection voltage protection、Zero sequ-
and hardware, relay protection, automation control, ergonomics, fieldbus communication and other Low-voltage protection ence overvoltage protection
internationally advanced technologies, integrated the design idea of layered distribution, object blocking, Monitoring Event log (capacity: 100 logs; resolution: 1ms; fault recording:8 areas)
centralized functions and unitized application. Application of products of this series can substantially simplify
Communication RS485、RS485 + Ethernet、Optical Fiber、Double Ethernet、PROFIBUS-DP
secondary design and construction, save vast installation space and wires and cables, realizing continuous
measuring, metering, monitoring, control and communication for medium-voltage distribution grid, Other External spring prevention circuit module
providing the user with protection product combination with high price performance ratio.
2AE Ordering Information
Product Features
Function Marking Content
·High-accuracy Measurement and Metering 0 Null
Apply Ti 32-bit high-performance DSP processor and high-accuracy AD chip; measurement 1 *3AI+1AO
accuracy of current, voltage can reach 0.2%. Extended 2 * External spring prevention circuit module
Function *3AI+1AO+External spring prevention circuit module
·Comprehensive Incident Remembrance and Diagnose 3
IRIG-B Appliance 0 Null
Support up to 100 event logs (resolution 1ms), that will not loss when power is failed;
Standards 1 *RS-422
Support fault recording for 8 areas (available for manual recording), and no loss when power is failed.
2 *TTL
·Friendly Man-machine Interface 1 RS485
Super-sized LCD screen , all operation information can be shown on one screen; 2 * Optical Fiber
Chinese/English dual interface. Communication 3 * RS485 + Ethernet
4 * Double Ethernet
·Sophisticated Communication Network 5 *PROFIBUS-DP
Support communication RS485, RS485+Ethernet and Double Ethernet, can be 0 0.2A
configured flexibly based on demands. Zero Sequence
Current 1 1A
Communication interface of RS485 and Ethernet system can support 5 5A
MODBUS-RTU/IEC60870 -5 -103, can be configured flexibly based on demands. 1 1A
Current
5 5A
·Wide-range Power Input 0 Null
Apply switching power supply module with internationally advanced input scope 1 (F) Line protection device
(110 / 220 VAC or VDC), suitable for various medium-voltage substations, and can also effectively Function Code 2 (T)Transformer Feeder Protection Device
restrain power down and voltage leap. 3 (M) Motor Protection Device
4 (C)Capacity Protection Device
·Complete Self-checking Capacity 5 *(B)Backup Automatic Switch Protection Device
It has self-test function, self-protection function, self-recovery capability, can effectively 32 2AEG150 Integrated Protection Device
prevent system from being out of control under abnormal circumstances 33 2AET287 Transformer Differential Protection Device
34 2AEM287 Motor Differential Protection Device
Product Code
2AET387 Transformer Differential Backup Protection
35 Device
36 2AEM387 Motor Differential Backup Protection Device
37 2AEU127 PT Voltage Protection Device (select 0