Real Time PCR Linegene 9600 Plus

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Biosan SIA., Ratsupites 7, build.

2, Riga, LV-1067, Latvia,


Phone: +371 674 261 37, Fax: +371 674 281 01,
E-mail: [email protected], www.biosan.lv

Real-Time PCR-LineGene 9600 Plus


DESCRIPTION

Line-Gene 9600 Plus is the newest product of Bioer’s Real-Time PCR detection system family. Based on Line-
Gene 9600’s large sample capacity, wide temperature range and multi-channels, Line-Gene 9600 Plus
provides brand-new & humanized running and operation interface for better operating experience.

Line-Gene 9600 Plus adopts Ferrotec specially-made Peltier, advanced fibber optic technology, new global
wide-range power supply, the unique patented block dissipation technology and bottom detection mode,
which provides better heating/cooling rate, temperature accuracy, uniformity and stability. Line-Gene 9600
Plus has up to 96 sample capacity and fast speed of dualcolor scanning, and the design of 5 channel detection
also covers the whole fluorescence detection wavelength.

Newly-designed automatic hot-lid without manual operation ensures constant pressure for various tube
heights. This auto hot-lid mode could be easily integrated into various automatic systems.

Newly-improved Line-Gene 9600 Plus Real-Time PCR detection system can satisfy various clients’ requirement
either for research or clinical use.
NUMÉRO DE
FLUORESCENCE CHANNELS LIST
CAT.
F1: FAM, SYBR Green
BYQ6094E 230VAC 50/60Hz Euro plug
F2: VIC, HEX, TET, JOE, CY3, TAMRA
F3: ROX, TEXAS RED
F4: CY5, Quasar-670
F5: CY5.5, Quasar-705

SOFTWARE FEATURES

Absolute Quantification
Relative Quantification
SNP Analysis
Data Automatic Analysis
Melting Curve Genotyping
Gradient
HRM Multi-channel
Crosstalk Correction
Background Correction
Automatic Gain
Customized Parameters

Biosan is an official distributor of LineGene 9600 Plus, Bioer in Latvia, Lithuania and Estonia. Other countries-
please, inquire.

Real-Time PCR-LineGene 9600 Plus Page 1 of 2


CARACTÉRISTIQUES
Capacité d’échantillon 96×0.2 ml (bottom transparent)

Dynamic range 1~10^10 copies

Excitation wavelength 300-800 nm

Emission wavelength 500-800 nm

Canaux 5

Plage d’ajustement de la
4 ~105°C (increment: 0.1°C)
température

Heating/coolling rate 4.0 °C/s

Précision de la témpérature ≤±0.1°C

Temperature fluctuation ≤±0.1°C

Uniformité de la température ≤±0.3°C

BLOCK/Tube simulation mode (automatic control based on sample


Temperature control mode
volume )

Volume d’échantillon 5 ~ 100 μl

Gradient temperature range 1 ~ 36°C

Hot-lid temperature range 30 ~110°C (adjustable default: 105°C, Automatic Hot-lid)

Repeatability 5%

Scan mode Entire plate or designated line

Program Max. 20 segments for each program, max. 99 cycles

Opération continue +

Scan period 5.5 s

Logiciel -----

Operating system Windows XP/Vista/7/8

Software required Microsoft Excel

Memory: 512MB, Hard Disk:10GB, CPU: Pentium® 4, Virtual


La configuration PC minimum
Memory: ≥1000MB

Tension nominale
100-240V; ~50/60Hz
d’alimentation

Consommation électrique 600W

Dimensions (L×D×H) 386×410×352 mm

Nombre d’emplacements USB adapter, Bluetooth adapter

Ferrotec pelitier / CE / Met / RoHS2 / PICC product quality liability


Certification
insurance

Tablet Microsoft Surface 2 pro

Real-Time PCR-LineGene 9600 Plus Page 2 of 2