EXCELSYS XF SERIES

THE MODULAR POWER SOLUTION OF CHOICE FOR HI REL AND


MIL-COTS
= APPLICATIONS

Advanced Energy's XF series, part of our Excelsys product


line, provides up to an incredible 1000 W in an extremely
compact 268 mm x 127 mm x 1U package. Designed for use in
harsh operating environments, the XF series is conformal coated
and ruggedized to withstand extremes in shock and vibration
as well as operation over a wide temperature range of -55 to
70°C. EMC characterization, shock and vibration, and thermal
stress reports are available.

PRODUCT HIGHLIGHTS

AT A GLANCE
 Conformal coated and   eries and parallel outputs
S
ruggedized as standard for higher voltages/ PowerPac
 Anti-vibration compound currents
Parallel powerpacs for XFA XFB XFC XFN
  7 to 440 Hz input
4 

frequency higher power


Power
  .15 V to 58 V standard
1  OVP, OTP, OCP as standard
output voltages   V/250 mA bias standby
5 400 700 1000 1000
 All outputs fully floating voltage provided
  xtra low profile: 1U height
E  Individual output control Slots
(40 mm)   ctive PFC (Power Factor
A 6 6 6 6
 Ultra high efficiency, Correction)
up to 90% Operating Temperature
 5-year warranty TYPICAL APPLICATIONS
-55 to 70°C -55 to 70°C -55 to 70°C -40 to 70°C
 Plug and play power
 Harsh industrial
Allows fast custom electronics Parameters
configuration
  ixed and mobile radar
F
 Outputs completely field 268 mm x 127 mm x 1U
(naval- and ground-based)
configurable with option
 Communications
to factory fix Certifications
 Military electronics

  IL-STD-810G: Shock and Vibration
M
 Test and measurement
 MIL-STD-461F (CE101 and CE102): EMC
characterised
 UL60950

 SEMI F47**
XF SERIES

MODELS

powerMods*

Model Vnom (V) Set Point Dynamic Vtrim Imax (A) Power (W) Remote Sense Power Good
Adjust Range Range (v)

XgA 12.0 10.8-15.6 — 12.5 150 — —

XgB 24.0 19.2-26.4 — 8.3 200 — —

XgC 36.0 28.8-39.6 — 5.6 200 — —

XgD 48.0 38.5-50.4 — 4.2 200 — —

XgE/Xg7 24.0 5.0-28.0 — 5.0 120 — —

XgF/Xg8 24.0 5.0-28.0 — 3.0 72 — Yes

24.0 5.0-28.0 — 3.0 72 — Yes

XgG 2.5 1.5-3.6 1.15-3.6 40.0 100 Yes Yes

XgH 5.0 3.2-6.0 1.5-6.0 36.0 180 Yes Yes

XgJ 12.0 6.0-15.0 4.0-15.0 18.3 220 Yes Yes

XgK 24.0 12.0-30.0 8.0-30.0 9.2 220 Yes Yes

XgL 48.0 28.0-58.0 8.0-58.0 5.0 240 Yes Yes

Xg1 2.5 1.5-3.6 1.15-3.6 50.0 125 Yes Yes

Xg2 5.0 3.2-6.0 1.5-6.0 40.0 200 Yes Yes

Xg3 12.0 6.0-15.0 4.0-15.0 20.0 240 Yes Yes

Xg4 24.0 12.0-30.0 8.0-30.0 10.0 240 Yes Yes

Xg5 48.0 28.0-58.0 8.0-58.0 6.0 288 Yes Yes

XgM 5.0 3.2-6.0 1.0 -6.0 40.0 200 Yes Yes

XgN 12.0 6.0-15.0 1.0 - 15.0 20.0 240 Yes Yes

XgP 24.0 12.0-30.0 1.0-30.0 10.0 240 Yes Yes

XgQ 48.0 24.0-58.0 1.0 to 58.0 6.0 288 Yes Yes

XgR 24.0 12.0-30.0 8.0-30.0 10.0 240 — Yes

XgT 48.0 28.0-58.0 8.0-58.0 6.0 288 — Yes

*When ordering individual powerMods for use with the XF Series add the suffix C for conformal coating

2 advancedenergy.com
XF SERIES

ELECTRICAL SPECIFICATIONS

Input

Parameter Conditions/Description Min Nom Max Units

Input Voltage Range Input frequency: 47 to 440 Hz. See note 10 85 — 264 VAC

120 — 380 VDC

Power Rating XFA — — 400 W

XFB — — 700 W

XFC — — 1000 W

XFN — — 1000 W

Input Current XFA: 85 VAC in 400 W out — 7.5 — A

XFB: 85 VAC in 700 W out — 9.5 — A

XFC: 85 VAC in 765 W out — 11.5 — A

XFN: 85 VAC in 765 W out — 11.5 — A

Inrush Current 230VAC @ 25°C — — 25 A

Undervoltage Lockout Shutdown 65 — 74 VAC

Power Factor 110 VAC @ full load 0.98 0.99 — —

Fusing XFA: 250 V — F8A HRC — —

XFB: 250 V — F10A HRC — —

XFC: 250 V — F12A HRC — —

XFN: 250 V — F12A HRC — —

Output

Parameter Conditions/Description Min Nom Max Units

powerMod Power As per powerMod table — — — —

Output Adjustment Range Manual or electronic as per powerMod table — — — —

Minimum Load — — 0 — A

Line Regulation For ±10% change from nominal line — — ±0.1 %

Load and Cross Regulation For 25% to 75% load change — — ±0.2 %

Transient Response For 25% to 75% load change — — — —

Voltage deviation — — 10 %

Settling time — — 250 µs

Ripple and Noise 20 MHz bandwidth 100 mv or 1.0% pk-pk — — — —

Overvoltage Protection Vmax (latching) — — 170 %

Overcurrent Protection Straight line with hiccup activation at < 30% of Vnom 105 — 170 %

Remote Sense Max. line drop compensation (see powerMod table) — 0.5 VDC

Overshoot — — — 2 %

Turn-On Delay From AC In/powerMod Enable signal — — 1000/6 ms

Rise Time Monotonic — — 5 ms

Hold-Up Time For nominal output voltages at full load 20 — — ms

Output Isolation Output to output/output to chassis 500/500 — — VDC

advancedenergy.com 3
XF SERIES

ELECTRICAL SPECIFICATIONS (CONTINUED)

General

Parameter Conditions/Description Min Nom Max Units

Isolation Voltage Primary to secondary 3000 — — VAC

Input to chassis 1500 — — VAC

Efficiency 230 VAC, 1000 W @ 24V — 90 — %

Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875 — — — —

Earth Leakage Current 230 VAC, 50 Hz, 25°C — — — mA

Bias Supply Always ON. Current 250 mA. 4.8 5.0 — VDC

Weight powerPac — 1.2 — kg

Typical powerMod — 0.1 — kg

Reliability Telcordia SR-332 at 40°C and full load powerMod — — .959 fpmh

Telcordia SR-332 at 40°C and full load powerPac (excludes fans) — — 0.95 fpmh

MIL-STD-217F at 30°C and full load powerMod — — 12.99 fpmh

MIL-STD-217F at 30°C and full load powerPac (excludes fans) — — 10.2 fpmh

Environmental

Parameter Conditions/Description Min Nom Max Units

Operating Temperature XFA, XFB, XFC -55 — +70 °C

XFN operates to specification below -20°C after 10 min warm-up -40 — +70 °C

Storage Temperature -55 — +75 °C

Derating See the product catalog for full temperature derating — — — —

Acoustic Noise Measured from distance of 1 m — 56.5 — dBA

Relative Humidity Non-condensing 5 — 95 %RH

Shock 3000 Bumps, 10 G (16 ms) half sine — — — —

Vibration 1.5G: MIL-STD-810G 10 — 500 Hz

Altitude Operational: 2000 m, Storage: 8000 m — — — —

4 advancedenergy.com
XF SERIES

ELECTRICAL SPECIFICATIONS (CONTINUED)

EMC

Parameter Standard Level

Emissions

Conducted EN55011, EN55022, FCC: Class B Compliant

Radiated EN55011, EN55022, FCC: Class B Compliant

Harmonic Distortion EN61000-3-2 Class A Compliant

Flicker and Fluctuation EN61000-3-3 Compliant

Immunity

Electrostatic Discharge EN61000-4-2: Level 2 Compliant

Radiated RFI EN61000-4-4: Level 3 & MIL-STD-461F. See note 6. Compliant

Fast Transients - Burst EN61000-4-4: Level 3 Compliant

Input Line Surges EN61000-4-5: Level 3 & MIL-STD-1399 Compliant

Conducted RFI EN61000-4-6: Level 3 & MIL-STD-461F. See note 6. Compliant

Voltage Dips EN61000-4-11 & MIL-STD-70, SEMI F47 compliant. See note 7. Compliant

** SEMI F47 compliant at input voltages > 160 VAC. Consult Advanced Energy for details.
1 All specifications at nominal input, full load, 25°C unless otherwise stated.

2 This product is not intended for use as a stand alone unit and must be installed by qualified personnel.

3 The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.

4 Derating required below -40 °C.

5 With

certain configurations when powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Consult
Advanced Energy for further detail.
6 An external filter is required to meet certain conducted and radiated emissions requirements for MIL-STD-461F.

7 SEMI F47 compliant at input voltages > 160 VAC.

8 Consult Advanced Energy for module derating at temperatures from -40°C to -55°C.

9 Product is not UL/EN certified for 120-380VDC input operation.

10 No safety approval for operation above 63 Hz

advancedenergy.com 5
XF SERIES

MECHANICAL SPECIFICATIONS

Output Connectors

The output powerMods connection details are shown below. Type A connectors are for single
output powerMods XgA-XgT and Xg1-Xg7.The Type B connector is for the dual output XgF/Xg8
powerMod. The power and signal connectors are as follows:

Type A Type B Type A : powerMods Type B: powerMod

XgA to XgE XgF/Xg8


J3 J3
V1 Adjust
Voltage 8 7 XgG to XgT —
8 7
Adjust Xg1 to Xg7 —
V2 Adjust
2 1
2 1
J4
J4 4

2
3

2
MECHANICAL SPECIFICATIONS (CONTINUED)
1
1

M4 Screws

Output Signals and Power Connector Pinout

Pin J3 J3 J3 J3 J3 J4 J4

Module (XgA to XgD) (XgG-XgQ) (XgR-XgT) (XgE) (XgF) (Type A) (Type B)

(Xg1-Xg5) (Xg7) (Xg8) — —

1 not used +Sense* not used not used -pg (V2) -Vout -V2

2 Common -Sense* -Vtrim not used +pg (V2) +Vout +V2

3 not used Vtrim +Vtrim not used Inhibit V2) — -V1

4 not used Itrim Itrim Common Common (V2) — +V1

5 +Inhibit +Inhibit/enable +Inhibit/enable -pg -pg (V1) — —

6 -Inhibit -Inhibit/enable -Inhibit/enable +pg +pg (V1) — —

7 not used +pg +pg Inhibit Inhibit (V1) — —

8 not used -pg -pg Common Common (V1) — —

*Remote sense not present on XgR and XgT powerMods

Output Mating Connectors


J1 IEC320 type female plug rated 13, locking IEC cable and connector: Schaffner EMC part number IL13-US1-SVT-3100-183

J2 Locking Molex 51110-0860; non locking 51110-0850; Crimp Terminal: Molex p/n 50394: Or Molex 51110-0856, includes
locking tab and polarization keying

6 advancedenergy.com
XF SERIES

MECHANICAL SPECIFICATIONS (CONTINUED)

Input Connectors

Advanced Energy modular power supplies have a variety of input connector options to ease
system integration. These include IEC, Input cables (3-wire) and IEC to Screw Terminal Adaptor.
Pin J1 J2
1 Line Common

2 Neutral +5V bias

3 Earth not used

4 — AC fail

5 — Fan fail
J1
Input AC 100 V-240 V
J2 6 — Global enable
See Instruction Manual
700 Max Operating Temperature
7 — Temp alarm

8 — Global inhibit

Input Mating Connectors


J1 IEC320 type female plug rated 13, locking IEC cable and connector: Schaffner EMC part number IL13-US1-SVT-3100-183

J2 Locking Molex 51110-0860; non locking 51110-0850; Crimp Terminal: Molex p/n 50394: Or Molex 51110-0856, includes
locking tab and polarization keying

Input Cable (Option D)

Advanced Energy modular power supplies are also available with an input cable connection option
allowing greater flexibility when mounting the power supply in the system. Individually insulated
input cables are 300 mm in length and come supplied with Faston connectors.

advancedenergy.com 7
XF SERIES

MECHANICAL SPECIFICATIONS (CONTINUED)

XF Series Derating Curves

Temperature Derating Curve for XF Models


1100
120 V & 230 V
XFA= Forward & Reverse Fans
1000
120 V & 230 V
900 XFB= Forward & Reverse Fans

800 120 V = XFC & XFN


Forward Fans
Pout (W)

700
120 V = XFC & XFN
Reverse Fans
600
230 V = XFC & XFN
500 Forward Fans

400 230V = XFC & XFN


Reverse Fans
300
-55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 75
Temperature (ºC)

Line Derating Curve for XF Models (@ 60ºC)


1100 XFA = Forward & Reverse Fans

1000 XFB = Forward & Reverse Fans

900 XFC & XFN = Forward Fans

800 XFC & XFN = Reverse Fans


Pout (W)

700

600

500

400

300
90 120 150 180 210 240 270
Vin AC (V)

8 advancedenergy.com
XF SERIES

MECHANICAL DRAWINGS

CONFIGURATION

powerMods Configuration Options Input Connector Option


e.g. A for XgA – = Standard 0 = IEC
B for XgB C = Conformal coating D = Flying Lead
0 for Empty Slot P = Factory preset

X F
XF Variant Reverse Fan and Leakage Current Factory
A for XFA 2 = Reverse Fan Assigned
B for XFB 4 = 150uA Leakage Current
C for XFC 6 = Reverse Fan + 150uA Leakage Current
N for XFN

-= Standard indicates that all voltages are set to the nominal setpoint of each module and there are no parallel/series links fitted to the power supply

advancedenergy.com 9
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three decades
to perfecting power for its global customers. AE designs and
manufactures highly engineered, precision power conversion,
measurement and control solutions for mission-critical appli-
cations and processes.

AE’s power solutions enable customer innovation in complex


semiconductor and industrial thin film plasma manufacturing
processes, demanding high and low voltage applications,
and temperature-critical thermal processes.

With deep applications know-how and responsive service and


support across the globe, AE builds collaborative partnerships
to meet rapid technological developments, propel growth for
its customers and power the future of technology.

Specifications are subject to change without notice. Not responsible for errors
or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved.
For international contact information, Advanced Energy® and AE® are U.S. trademarks, and CoolX® is a U.S. and
visit advancedenergy.com Europe trademark of Advanced Energy Industries, Inc.

ENG-LV-XF-235-15 04.20