En LV XF Data Sheet
En LV XF Data Sheet
PRODUCT HIGHLIGHTS
AT A GLANCE
Conformal coated and eries and parallel outputs
S
ruggedized as standard for higher voltages/ PowerPac
Anti-vibration compound currents
Parallel powerpacs for XFA XFB XFC XFN
7 to 440 Hz input
4
SEMI F47**
XF SERIES
MODELS
powerMods*
Model Vnom (V) Set Point Dynamic Vtrim Imax (A) Power (W) Remote Sense Power Good
Adjust Range Range (v)
*When ordering individual powerMods for use with the XF Series add the suffix C for conformal coating
2 advancedenergy.com
XF SERIES
ELECTRICAL SPECIFICATIONS
Input
Input Voltage Range Input frequency: 47 to 440 Hz. See note 10 85 — 264 VAC
XFB — — 700 W
XFC — — 1000 W
XFN — — 1000 W
Output
Minimum Load — — 0 — A
Load and Cross Regulation For 25% to 75% load change — — ±0.2 %
Voltage deviation — — 10 %
Overcurrent Protection Straight line with hiccup activation at < 30% of Vnom 105 — 170 %
Remote Sense Max. line drop compensation (see powerMod table) — 0.5 VDC
Overshoot — — — 2 %
advancedenergy.com 3
XF SERIES
General
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875 — — — —
Bias Supply Always ON. Current 250 mA. 4.8 5.0 — VDC
Reliability Telcordia SR-332 at 40°C and full load powerMod — — .959 fpmh
Telcordia SR-332 at 40°C and full load powerPac (excludes fans) — — 0.95 fpmh
MIL-STD-217F at 30°C and full load powerPac (excludes fans) — — 10.2 fpmh
Environmental
XFN operates to specification below -20°C after 10 min warm-up -40 — +70 °C
4 advancedenergy.com
XF SERIES
EMC
Emissions
Immunity
Voltage Dips EN61000-4-11 & MIL-STD-70, SEMI F47 compliant. See note 7. Compliant
** SEMI F47 compliant at input voltages > 160 VAC. Consult Advanced Energy for details.
1 All specifications at nominal input, full load, 25°C unless otherwise stated.
2 This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
3 The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
5 With
certain configurations when powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Consult
Advanced Energy for further detail.
6 An external filter is required to meet certain conducted and radiated emissions requirements for MIL-STD-461F.
8 Consult Advanced Energy for module derating at temperatures from -40°C to -55°C.
advancedenergy.com 5
XF SERIES
MECHANICAL SPECIFICATIONS
Output Connectors
The output powerMods connection details are shown below. Type A connectors are for single
output powerMods XgA-XgT and Xg1-Xg7.The Type B connector is for the dual output XgF/Xg8
powerMod. The power and signal connectors are as follows:
2
3
2
MECHANICAL SPECIFICATIONS (CONTINUED)
1
1
M4 Screws
Pin J3 J3 J3 J3 J3 J4 J4
1 not used +Sense* not used not used -pg (V2) -Vout -V2
J2 Locking Molex 51110-0860; non locking 51110-0850; Crimp Terminal: Molex p/n 50394: Or Molex 51110-0856, includes
locking tab and polarization keying
6 advancedenergy.com
XF SERIES
Input Connectors
Advanced Energy modular power supplies have a variety of input connector options to ease
system integration. These include IEC, Input cables (3-wire) and IEC to Screw Terminal Adaptor.
Pin J1 J2
1 Line Common
4 — AC fail
5 — Fan fail
J1
Input AC 100 V-240 V
J2 6 — Global enable
See Instruction Manual
700 Max Operating Temperature
7 — Temp alarm
8 — Global inhibit
J2 Locking Molex 51110-0860; non locking 51110-0850; Crimp Terminal: Molex p/n 50394: Or Molex 51110-0856, includes
locking tab and polarization keying
Advanced Energy modular power supplies are also available with an input cable connection option
allowing greater flexibility when mounting the power supply in the system. Individually insulated
input cables are 300 mm in length and come supplied with Faston connectors.
advancedenergy.com 7
XF SERIES
700
120 V = XFC & XFN
Reverse Fans
600
230 V = XFC & XFN
500 Forward Fans
700
600
500
400
300
90 120 150 180 210 240 270
Vin AC (V)
8 advancedenergy.com
XF SERIES
MECHANICAL DRAWINGS
CONFIGURATION
X F
XF Variant Reverse Fan and Leakage Current Factory
A for XFA 2 = Reverse Fan Assigned
B for XFB 4 = 150uA Leakage Current
C for XFC 6 = Reverse Fan + 150uA Leakage Current
N for XFN
-= Standard indicates that all voltages are set to the nominal setpoint of each module and there are no parallel/series links fitted to the power supply
advancedenergy.com 9
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three decades
to perfecting power for its global customers. AE designs and
manufactures highly engineered, precision power conversion,
measurement and control solutions for mission-critical appli-
cations and processes.
Specifications are subject to change without notice. Not responsible for errors
or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved.
For international contact information, Advanced Energy® and AE® are U.S. trademarks, and CoolX® is a U.S. and
visit advancedenergy.com Europe trademark of Advanced Energy Industries, Inc.
ENG-LV-XF-235-15 04.20