0% found this document useful (0 votes)
276 views2 pages

Octagonal Pole

This document provides the technical specifications for octagonal lighting poles produced by Ventura Lighting Limited, including pole dimensions, material thicknesses, base plate sizes, and foundation bolt configurations for pole heights between 4 and 12 meters. Dimensions include the total pole height, top and bottom diameters, wall thickness, base plate size and thickness, and number and pattern of foundation bolts.

Uploaded by

ARUN RAWAT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
276 views2 pages

Octagonal Pole

This document provides the technical specifications for octagonal lighting poles produced by Ventura Lighting Limited, including pole dimensions, material thicknesses, base plate sizes, and foundation bolt configurations for pole heights between 4 and 12 meters. Dimensions include the total pole height, top and bottom diameters, wall thickness, base plate size and thickness, and number and pattern of foundation bolts.

Uploaded by

ARUN RAWAT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

VENTURA LIGHTING LIMITED

Subsidiary of
VENTURA BSCIC
LIGHTING VENTURA LIGHTING AND INFRATECH LIMITED www.jas-anz.com.au/register

ISO 9001 REGISTERED

TECHNICAL SPECIFICATION OF OCTAGONAL POLES


TOP A/F OUTSIDE d

BRACKET FOR
ELEC.BOARD MTG.

L
DOOR
OPENING
D

REGULAR
OCTAGONAL
T1
H

d
STIFENER PLATE
(X4)
T

BOTTOM A/F (OUT SIDE)

'' B ''
L

PCD of Bolts
'' L ''

Top Dia -' TD '


Bottom Dia-'
BD'
Suitable Slots
for Foundation
Bolts
SEC C - C VIEW FROM TOP OF THE POLE
DIMENSION OF OCTOGONAL POLE WITH BASE PLATE FOUNDATION TYPE
FOR MAXIMUM WIND SPEED OF 180 Km/h
Series Pole (P)
Pole Height Total Height - 'H' Top Dia - "TD" Base Dia - "BD" Thickness Base Plate Foundation Bolt
(T1) {LxBxT) Detail
VL 4.0 P 4000 70 130 03 200X200X12 4X16 ON P.C.D-175
VL 5.0 P 5000 70 130 03 200X200X12 4X16 ON P.C.D-175
VL 6.0 P 6000 70 130 03 220X220X12 4X16 ON P.C.D-175
VL 7.0 P 7000 70 130 03 220X220X12 4X20 ON P.C.D-175
VL 8.0 P 8000 70 135 03 225X225X16 4X20 ON P.C.D-190
VL 9.0 P 9000 70 155 03 260X260X16 4X20 ON P.C.D-210
VL 10.0 P 10000 70 175 03 275X275X16 4X25 ON PCD-225
VENTURA

VL 11.0 P 11000 90 210 03 300X300X20 4X25 ON P.C.D-260


VL 12.0 P 12000 90 240 03 320X320X20 4X27 ON P.C.D-290
Abbreviation: H=Total height, T1=Sheet thickness, D=Door Opening, L=Foundation Bolt Length, d=Bolt Diameter
Sales Office :- C-33, East of Kailash, New Delhi-110065, Tel.: 011-26842693 Fax : 91-11-26842693
Photometric Centre:- 142 A/1, NSEZ, NOIDA
Works :- 136, Industrial Area, Malanpur, (Ghirongi) Distt. Bhind, (MP)
Email.: [email protected] www.venturalighting.com