TC FLS Sihi LPHX 40000 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

SIHILPH-X - Liquid Ring Vacuum Pump

One Stage

LPH 40106, LPH 40411, LPH 40516

Pressure Range: 150 to 1013 mbar


Suction Range: 45 to 275 m³/h

CONSTRUCTION
SIHI liquid ring vacuum pumps have a simple but robust
construction with the following features and benefits:

Near isothermal compression


Oil free, with no internal lubrication
Capable of handling almost all gases and vapours
Able to handle quantities of liquid “carry over”
Low maintenance and safe operation
Low noise and almost vibration free
Available in a wide range of materials
Broad range of applications
O-ring sealing as standard
Drain hole as standard
Built-in solids drain
Rotating metallic parts are non contacting to minimise wear
ATEX compliance

SIHI liquid ring vacuum pumps of the range LPH 40106, LPH
40411 and LPH 40516 are one stage pumps. They can be used as NOTE
compressors without any modification. By continuously feeding the pump with a small amount of service
liquid (usually water), the heat due to gas/vapour compression is
APPLICATIONS conducted away. This also replenishes the liquid ring and ensures
Evacuation and pumping of dry gases and saturated vapours. The that it does not become saturated with process media. The
pumps can also handle liquids. These units offer pressures in the condensed gas and fluid can be separated in a liquid separator
range of 150…900 mbar(a) to atmospheric. Typical application (see Accessories Catalogue). Recharging the pump with service
areas include: liquid at ambient temperature enables the unit to condense
Chemical and pharmaceutical industry for distillation, drying evacuated gases/vapours. It can therefore be used for solvent
and degassing recovery. More information is provided in the accessory catalogues.
Electronic industry for impregnation and drying The integrated solids drain permits the removal of any entrained
Plastics & Rubber industry for degassing solids whilst the pump is operating. The service liquid can,
Food and beverage industry for bottle filling. therefore, simply be re-circulated.
The rotation of the pump is clockwise when viewed from the drive
end.

GENERAL TECHNICAL DATA


Pump Type Units LPH 40106 LPH 40411 LPH 40516
Speed 50 Hz rpm 1450
60 Hz rpm 1740
Maximum overpressure on compression bar 0.6 0.8 0.4
Permissible pressure difference max. 1.2 1.2 1.2
bar
between suction and discharge side min. 0.2 0.2 0.2
Hydraulic test pressure (overpressure) bar 3.0
Moment of inertia of rotating parts
kg . m² 0.0375 0.05 0.065
of pump and water content
Noise level at 200 mbar suction pressure [50Hz] dB (A) 57 61.5
Minimum permissible pulley diameter for V belt drive mm 160
Maximum gas temperature dry °C 200
saturated °C 100
Service liquid:
Maximum permissible temperature °C 80
Minimum permissible temperature °C 10
Maximum viscosity mm²/s 90
Maximum density kg/m³ 1200
Liquid capacity up to middle of shaft litre 3.5 4.5 5.5
Maximum flow resistance of the heat exchanger bar 0.2
In selecting a pump, avoid choosing one which is likely to be operating at a combination of its maximum permissible limits e.g. maximum
viscosity and maximum permissible pressure difference.

VACUUM TECHNOLOGY LPH LI 2


133.71120.65.01 E 41/2018
SIHILPH-X
Materials

Materials
Position number Component 0K 4B

10.60 Casing
1.4408
10.90 Central body 0.6025

13.70 Guide disc


1.4404
21.00 Shaft 1.4021

23.50 Impeller 1.4308 1.4408

Mechanical seal,
43.30, 43.31 Cr-Steel / Carbon / Butadiene rubber Cr Ni Mo-Steel / Carbon / Viton
Type SIHI FK (AG)

43.30, 43.31 Double mechanical seal on request

Cut-away diagram LPH 40106, LPH 40411, LPH 40516 with single and double mechanical seal

2
SIHILPH-X
Performance Characteristics LPHX 40106

The operating data is valid under the following conditions:

 Process media: - dry air: 20°C


- steam saturated air: 20°C

 Service liquid: - water: 15°C

Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure)


The suction volume is related to the suction pressure.
Tolerance for the suction volume flow is 10% and for power 5%.
The maximum consumption of make up water occurs at the lowest suction pressure.

3
SIHILPH-X
Performance Characteristics LPHX 40411

The operating data is valid under the following conditions:

 Process media: - dry air: 20°C


- steam saturated air: 20°C

 Service liquid: - water: 15°C

Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure)


The suction volume is related to the suction pressure.
Tolerance for the suction volume flow is 10% and for power 5%.
The maximum consumption of make up water occurs at the lowest suction pressure.

4
SIHILPH-X
Performance Characteristics LPHX 40516

The operating data is valid under the following conditions:

 Process media: - dry air: 20°C


- steam saturated air: 20°C

 Service liquid: - water: 15°C

Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure)


The suction volume is related to the suction pressure.
Tolerance for the suction volume flow is 10% and for power 5%.
The maximum consumption of make up water occurs at the lowest suction pressure.

5
SIHILPH-X
Dimensions LPH 40106, LPH 40411, LPH 40516 with single mechanical seal

1) = Connection uB on both sides is only necessary for LPH 40516

Gas inlet DN 40 (according to DIN EN 1092 PN 10)


N1 =
Gas inlet 1 ½“ (according to ANSI 150 lbs)
Gas outlet DN 40 (according to DIN EN 1092 PN 10)
N2 =
Gas outlet 1 ½“ (according to ANSI 150 lbs)
uB = Connection for service liquid G ½
ue = Connection for drain G 1/8
use = Connection for dirt drain G 1/8
ul = Connection for air cock G ½
um = Connection for pressure gauge G ¼
um1 = Connection for drainage valve or liquid level sensor G ¼

a m1 m2 o3 approx. weight
[mm] [mm] [mm] [mm] [kg]
LPH 40106 144 258 204 431 55
LPH 40411 194 308 254 481 60
LPH 40516 244 358 304 531 65

6
SIHILPH-X
LPH 40106, LPH 40411, LPH 40516 with single mechanical seal and top-mounted liquid separator

N1 = Gas inlet DN 40
N2 = Gas outlet DN 50
Liquid drain G 1 for LPH 40106,
uA =
G 1½ for LPH 40111 and 40516
uA1 = Liquid drain G 1/2
uF = Connection for make-up water G ½

1) = pipework to second side is only for LPH 40516

electric motor 50 Hz
base-
kW a f1 f2 e1 h1 l l1 v o1 * approx. weight
size plate
IP 55 EEx e ll T3 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg]
100 L 2.2 - 115
LPH
100 L 3.0 - S301 144 116 480 877 730 224 125 305 120
40106
100 L - 2.5 120
178
112 M 4.0 - 140
LPH 320
112 M - 3.6 194 274 145
40411
132 S - 5.0 S303 72 600 997 920 160 175
LPH 132 S 5.5 - 405 165
244 230 324
40516 132 M - 6.8 200
* dimensions dependent upon motor supplier

flange connections according to DIN EN 1092 PN 10


[mm]
DN 40 50
k 110 125
D 150 165
number x d2 4 x 18 4 x 18

7
SIHILPH-X
LPH 40106, LPH 40411 with single mechanical seal and side-mounted liquid separator

N1 = Gas inlet DN 40
N2 = Gas outlet DN 50
uA = Liquid drain G 1
ue1 = Connection for drain G ½
uF = Connection for make-up liquid 18 mm
uFl = Connection for liquid level indicator G ½

electric motor 50 Hz base-


kW plate a e1 l l1 v o1 * approx. weight
size
IP 55 EEx e ll T3 [mm] [mm] [mm] [mm] [mm] [mm] [kg]
100 L 2.2 - 135
LPH
100 L 3.0 - S301 144 480 730 224 125 305 140
40106
100 L - 2.5 140
112 M 4.0 - 160
LPH 320
112 M - 3.6 S303 194 600 920 274 160 165
40411
132 S - 5.0 405 195

* dimensions dependent upon motor supplier

flange connections according to DIN EN 1092 PN 10


[mm]
DN 40 50
k 110 125
D 150 165
number x d2 4 x 18 4 x 18

8
SIHILPH-X
LPH 40516 with single mechanical seal and side-mounted liquid separator

N1 = Gas inlet DN 40
N2 = Gas outlet DN 80
uA = Liquid drain DN 32
ue1 = Connection for drain G ½
uF = Connection for make-up liquid 18 mm
uFl = Connection for liquid level indicator G ½

electric motor 50 Hz
base- approx. weight
kW plate
size
IP 55 EEx e ll T3 [kg]

LPH 132S 5.5 - 185


S 303
40516 132 M - 6.8 220

* dimensions dependent upon motor supplier

flange connections according to DIN EN 1092 PN 10


[mm]
DN 32 40 80
k 100 110 160
D 140 150 200
number x d2 4 x 18 4 x 18 8 x 18

9
SIHILPH-X
Make-up Liquid Consumption in [m³/h] dependent upon suction pressure, speed, drive type and temperature difference.
suction pressure
in [mbar] 150 400 600 800

KB KB KB KB
speed temperature FB temperature FB temperature FB temperature FB
pump type
[rpm] difference [°C] difference [°C] difference [°C] difference [°C]
20 10 5 2 20 10 5 2 20 10 5 2 20 10 5 2
1450 0.08 0.16 0.28 0.53 0.08 0.15 0.26 0.46 0.07 0.13 0.22 0.39 0.05 0.09 0.15 0.24
LPH 40106
1740 0.11 0.20 0.34 0.61 0.10 0.18 0.31 0.53 0.09 0.16 0.26 0.44 0.06 0.11 0.13 0.16
1.3 1.0 0.8 0.45
1450 0.12 0.22 0.38 0.66 0.12 0.22 0.35 0.58 0.11 0.19 0.31 0.49 0.07 0.12 0.19 0.29
LPH 40411
1740 0.16 0.28 0.46 0.75 0.15 0.26 0.42 0.64 0.14 0.23 0.36 0.54 0.09 0.15 0.22 0.32
1450 0.19 0.34 0.58 1.01 0.19 0.34 0.56 0.91 0.18 0.31 0.49 0.76 0.13 0.22 0.33 0.47
LPH 40516 2.0 1.6 1.2 0.7
1740 0.24 0.42 0.70 1.14 0.23 0.40 0.64 1.0 0.21 0.36 0.55 0.81 0.16 0.25 0.36 0.49

FB = Total service liquid flow rate on once-through system


KB = Flow of makeup water when combined with partial recirculation liquid at a temperature of 20°C, 10°C, 5°C, 2°C warmer than make-up water.

Data regarding the pump size - order notes


Range + Size Hydraulic + Bearings Shaft Seal Materials Casing Sealing

AGE Mechanical seal


Type SIHI FK, 0K Main parts out of cast iron,
A 1. hydraulic O-rings butadiene rubber impeller in
low alloyed steel 1 O-ring-
B two greased AG1 Mechanical seal sealing
roller bearings Type SIHI FK, 4B Main parts out of
O-rings Viton stainless steel

40106
LPH 40411 AB AGE, AG1 0K, 4B 1
40516

Motor Selection

For our products we offer a lot of different motor types.


To identify the right motor please specify frequency, voltage and protection class.

Example of an Order:

LPHX 40106 AB AGE 0K 1 with 3.0 kW AC motor, 50 Hz, 400V , IP55

10
SIHILPH-X
Spare Parts Order Number

Material Design 0K
Group Spare parts kit LPH 40106 LPH 40411 LPH 40516
20.00 Shaft 65 006 715 65 006 714 65 006 713
49.99 Basic Repair AGE 65 008 221

Material Design 4B
Group Spare parts kit LPH 40106 LPH 40411 LPH 40516
20.00 Shaft 65 006 754 65 006 755 65 006 756
49.99 Basic Repair AG1 65 008 223

11
SIHILPH-X
Accessories

Recommended Accessory Material Execution LPH 40106 LPH 40411 LPH 40516
Top Mounted Liquid Separator Type / Weight XBa 1040 / 10 kg XBa 1340 / 14 kg
Top mounted separator 1.4571 SIHI-Part No. 43 253 089 43 253 090
Service liquid pipework, Steel, galvanised SIHI-Part No. 20 054 515 20 058 985 20 058 986
standard execution 1.4571 20 054 517 20 058 993 20 058 995
Service liquid pipework, Steel, galvanised + Brass SIHI-Part No. 20 059 008
on request
thermostatic control 24V 1.4571 + Brass 20 048 978
Side Mounted Liquid Separator Type / Weight XBp 0413 / 28 kg XBp 0414 / 31 kg
Side mounted separator 1.4571 SIHI-Part No. 35 000 503 35 000 505
Service liquid pipework, Steel, galvanised SIHI-Part No. 20 058 982 20 058 983 20 058 984
standard execution 1.4571 20 058 990 20 058 991 20 058 992
Service liquid pipework, Steel, galvanised + Brass SIHI-Part No. 20 059 099 20 094 388
thermostatic control 24V 1.4571 + Brass 20 059 100 on request
Pressure pipework (bend) 1.0254 SIHI-Part No. 35 003 165 35 023 751
1.4571 35 003 166 35 023 750
Liquid level indicator Brass / Plexiglas SIHI-Part No. 43 014 911
1.4571 / Plexiglas 43 040 384
Sterling SIHI - Non Return Ball Valve
Intermediate flange 0.6025 + Butadiene Rubber SIHI-Part No. 20 072 746 / 2.8 kg
execution XCk 40 0.6025 + Teflon Weight 20 072 745 / 2.8 kg
1.4408 + Teflon 20 029 494 / 5.2 kg
Flange execution with glass 0.6025 + Butadiene Rubber SIHI-Part No. 20 072 835 / 7.0 kg
cylinder XCk 406 0.6025 + Teflon Weight 20 072 836 / 7.0 kg
1.4408 + Teflon 20 072 834 / 7.0 kg
Adapter Flange Steel SIHI-Part No. 1 x 20 059 826 1 x 20 059 827
not necessary
1.4571 1 x 20 060 458 1 x 20 060 489
Drain Valve Steel + Teflon SIHI-Part No. 43 166 248
XCg 015 1.4571 + Teflon 43 014 547
Double nipple ½“-¼“ Steel, galvanised SIHI-Part No. 43 049 216
1.4571 43 013 084
Air Inlet Valve Brass SIHI-Part No. 43 014 257 + 43 060 102
1.4408 43 014 271
Motor
Motor standard execution IP 55 Size 100 L 100 L 112 M 132 S
Power 2.2 kW 3.0 kW 4.0 kW 5.5 kW
Weight 18 kg 20 kg 28 kg 45 kg
Coupling for motor IP 55 Type / Weight B 80 / 1.5 kg B 95 / 2.6 kg
Pump side SIHI-Part No. 43 021 414 43 021 426
Motor side 43 021 417 43 021 433
Coupling guard Steel SIHI-Part No. 43 042 248
Motor in EEx e ll T3 execution Size 100 L 112 M 132 S 132 M
Power 2.5 kW 3.6 kW 5.0 kW 6.8 kW
Weight 22 kg 30 kg 65 kg 80 kg
Coupling for Motor EEx e ll T3 Type / Weight BDS 88 / 2.0 kg BDS 103 / 3.1 kg
Pump side SIHI-Part No. 43 111 058 43 111 051
Motor side 43 111 029 43 111 040
Coupling guard Brass SIHI-Part No. 43 042 249
Baseplate Steel Type / Weight S 301 / 27 kg S 303 / 34 kg
SIHI-Part No. 43 040 634 43 040 635

Designs subject to change without prior notice.

Flowserve SIHI Germany GmbH


Lindenstraße 170, D-25524 Itzehoe, Germany, Tel. +49 (0) 48 21 / 7 71 - 01, Fax +49 (0) 48 21 / 7 71-274

12