100% found this document useful (1 vote)
550 views12 pages

Manual Wind Controller 2

The document is a user manual for a wind/solar hybrid controller. It describes the controller's functions which include reliably charging batteries from wind turbines and solar panels, displaying system parameters on an LCD screen, protecting the batteries from over/under charging, and optionally communicating data to monitor the system remotely. The controller is suitable for hybrid power and monitoring systems up to 20kW and 240V.

Uploaded by

Kazedr 15
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
550 views12 pages

Manual Wind Controller 2

The document is a user manual for a wind/solar hybrid controller. It describes the controller's functions which include reliably charging batteries from wind turbines and solar panels, displaying system parameters on an LCD screen, protecting the batteries from over/under charging, and optionally communicating data to monitor the system remotely. The controller is suitable for hybrid power and monitoring systems up to 20kW and 240V.

Uploaded by

Kazedr 15
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Wind/Solar 

Hybrid Controller  User Manual 

User’s Manual 
Wind/Solar Hybrid Controller 

Please  Read  This  User  Manual  Carefully  Prior  to 


Installation and Operation of This Product. 

2014 V1.0
Wind/Solar Hybrid Controller  User Manual 

Notices 
1)  Battery reverse­connection is forbidden. 

2)  Battery virtual connection or damage is one main factor of malfunction. Please check battery 

voltage  and  connection  status  weekly,  clear  rust  on  positive,  negative  terminal  in  time;  use 

lead terminal if available. 

3)  If  the  malfunction  is  not  easy  to  eliminate  or  reason  unclear,  please  write  down  the 

phenomenon in detailed record, and contact manufacturer for help in time. 

Installation Environment 
1) The equipment should be installed indoor where is well­ventilated. 

2) Avoid exposing the apparatus under direct sunshine, exposure, rain, moist, acid mist and dust. 

3) Allow at least 20 inches (0.5 m) distance from battery. 

4) Ambient Temperature is ­20~+55℃; Ambient Humidity is 35 ~85%RH, no condensing. 

5)  Do  not  install  the  equipment  in  a  compartment  with  flammable  liquids,  such  as 

gasoline, or explosive vapors. Be ware of the flame and the spark. 

1. General Description 

The  wind/solar  hybrid  controller  is  an intelligent  control  device  which  can  control  wind  turbine 
and  solar  panel  at  the  same  time,  specially  designed  for  high­end  wind/solar  hybrid  system  and 
also suitable  for  wind/solar hybrid power system and  wind/solar hybrid  monitoring system.  It is 
used to control the wind generator and solar panel to charge the batteries safely and efficiently. 

With decent appearance, easy operation, visual LCD display and perfect protection functions, the 
apparatus has high charge efficiency, low no­load loss. 

The wind/solar hybrid controller is the core component of the off­grid power generation system. 
The  performance  of  the  controller  will  impact  the  life  and  the  stability  of  the  whole  system, 
especially the lifespan of battery banks.

1/11 
Wind/Solar Hybrid Controller  User Manual 

2. Model Specification 

Rated Input  Rated Battery  Optional 


Product Name  Feature 
Power  Voltage  Function 
06  0.6 kW  24  24V  N  Normal  00  Normal 
Low Voltage 
10  1kW  48  48V  L  01  RS232 
Charge 
Buck oltage 
20  2kW  96  96V  D  02  RS485 
Charge 
Solar Dumpload 
30  3kW  120  120V  B  Economic  04 
Separately 
Micro­current  Wind Turbine 
Wind solar  50  5kW  220  220V  S  10 
Charge  Single Phase DC 
WWS  hybrid 
RS232 
controller 
Wind Turbine 
100  10kW  240  240V  11 
Single Phase DC, 
RS232 
RS485 
Wind Turbine 
200  20kW  12 
Single Phase DC, 
RS232 
XX  Other 

Remark: Micro­current Charge Function is only available for system no more than 3kW Power 
running with Battery Banks no more than 48V. 
E.G.:WWS20­48­L01 Rated Output Power: 2kW 
Rated Battery Voltage: 48V 
With Low Voltage Charge and RS232 communication function

2/11 
Wind/Solar Hybrid Controller  User Manual 

3. Performance Description 
²  Reliability:Intelligentized,  modularized  design,  simple  mechanism,  powerful  functions. 
With  industrial  range  superior  components  and  strict  production  technology,  the  controller 
can  be  used  in  relatively  bad  working  environment  and  has  reliable  performance  and  long 
life­span. 

²  PWM  Stepless  Dumpload  Mode:  dump  residual  power  with  division  into  thousands  of 
stages.  It  can  dump  residual  power  while  charging  battery  banks,  which  is  benefit  to 
effectively extend battery longevity. 

²  Voltage Limiting and Current Limiting Charge Mode: 
When  battery  voltage  exceeds  the  pre­set  floating  voltage  point,  the  controller  will  adopt 
PWM  voltage  limiting  charge  mode.  It  dumps  the  excess  energy.  When  wind  turbine 
charging  current  exceeds  pre­set  brake  current  point,  the  controller  will  automatically  start 
brake to protect battery banks. 

²  LCD  Display  Function:  LCD  screen  can  display  system  status  and  parameters  via  visual 
digital  and  graphic  form.  Such  as:  battery  voltage,  wind  turbine  voltage,  PV  voltage,  wind 
turbine current, PV current, wind turbine power, PV power, battery power status etc. 

²  Perfect  Protection  Functions:  Battery  over  charge  protection,  Battery  over  discharge 
protection,  Battery anti­reserve  connection  protection,  wind turbine  current­limiting charge, 
automatic  brake,  manual  brake;  solar  anti­reverse  charge  protection,  solar  anti­reverse 
connection protection, lightning protection, etc. 

(Note:  Following  optional  functions  are  valid  only  for  controllers  which  have  these 
functions) 

²  Optional Remote Communication Function: 
The software can  monitor real­time system running status, which contain all the parameters 
on  the  LCD  screen.  Through  the  software,  users  can  not  only  set  and  adjust  relevant 
parameters,  but  also  can  control  the  wind  turbine  and  load  running  status,  and  alarm  while 
malfunction happens. 

²  Optional Low Voltage Charge Function: 
Boost module is added in the controller to help wind turbine charge battery banks even in low 
wind or the wind turbine rotates in low speed. User can adjust the admittance value and start 
charge voltage via software according to different wind turbine parameters.

3/11 
Wind/Solar Hybrid Controller  User Manual 

²  Optional Dry­contact signal Function: 
When  the  battery  is  reaching  setting  value,  the  controller  will  automatically  output 
dry­contact signal. 

²  Optional Temperature Compensation Function: 
The  controller  can  adjust  the  unload  voltage  according  to  different  ambient  temperature  so 
that the battery charge is in the best efficiency. 

²  Optional SD card Function: 
With SD card, controller store system history data when the controller disconnected with PC. 

²  Optional Wind Speed Detection Function: 
The  controller  can  detect  real­time  wind  speed  when  it  is  matched  with  appointed 
anemometer. User can read the real­time wind speed via monitoring software. 

²  Optional Micro­current Charge Function: 
When the wind turbine input voltage reaches to the pre­set value, the controller will produce 
the micro­current charge for the battery. 

²  Optional  Wind  Turbine  Rotate  Speed  Detection  Function:  User  can  read  the  real­time 
wind turbine rotate status via monitoring software. 

²  Optional DC Output Function: DC output offers power for DC load, with various control 
modes for choice, including: Constant on; Constant off; Constant half­power; light­control on, 
light­control off; light­control on, time­control off; light­control on, time­control half­power, 
light­control off; light­control on, time­control half­power, time­control off. Via LCD buttons, 
users  can  set  three  output  control  modes:  constant  on;  light­control  on,  light­control  off; 
light­control on, time­control off. 

4. Installation Flow 
Remark: Users should connect according to the following corresponding connection: 

PIC A

4/11 
Wind/Solar Hybrid Controller  User Manual 

PIC B 

PIC C 

PIC D 
User should connect and  operate all  parts according to  following  procedures after  wind turbine, 
solar panel and external circuit constructions are finished. 

Step 1.  Check  the  package  and  then  check  the  controller  for  damage  after  unpacking. 
Damaged controller cannot be installed in the system. 

Step 2.  For  controller  whose  dumpload  box  is  separated,  please  connect  dumpload  box  to  the 
“DUMP LOAD” terminals of the controller. 

Step 3.  Connect battery positive pole to the positive (+) “BATTERY” terminal, Connect battery

5/11 
Wind/Solar Hybrid Controller  User Manual 

negative pole to the negative (­) “BATTERY” terminal with copper core cable. 

(Note:  Although  the  controller  has  anti­reverse  connection  protection  function,  wrong 
polarity  of  battery  shall  be  forbidden!  Please  refer  to  Appendix  I  for  copper  wire  over 
current capability.) 

Step 4.  Connect the wind turbine output lines to the “WIND INPUT” terminals in condition of 
wind turbine in action­less or low speed. 

Step 5.  Connect solar panels to the “SOLAR INPUT” terminals. 

Step 6.  Check all connection is proper and firm or not. 

Step 7.  If the controller has communication function, user can read and set relevant parameters 
via software. 

Step 8.  User can set relevant parameters through LCD buttons. 

5. LCD Display Instruction and Button Specification 

5.1 LCD Display Instruction 

1)  Wind turbine symbol. 

2)  Day symbol.  Night symbol. 

3)  Battery symbol, 
inner strip graph indicates the battery power status. Five inner horizontal 
strips display indicates the battery is full. The symbol  shall be flashing when the battery 

is over­discharge, flashing will not stop until battery voltage recover. The symbol  shall 
be flashing when the battery is over charge, flashing will not stop until battery voltage recover. 

4)  Parameters display symbol. Each system parameters are displayed via visual digit 
and graph. 

5)  Press the "Enter" key and "Esc" button at the same time, LCD displays the symbol 
which indicates wind turbine in brake status. Wind turbine will stop rotating or running in

6/11 
Wind/Solar Hybrid Controller  User Manual 

low speed under brake status. Press the "Enter" key and "Esc" button at the same time under brake 
status,  the  symbol  will  disappear  and  brake  status  is  released.  In  normal  situation,  the 
wind turbine shall be in running status rather than brake status. 

5.2 Button Specification 

LCD  backlight  will  be  on  after  pressing  any  button.  The  backlight  will  go  out  to  save  power  if 
there is no button operation for 10 seconds. 

² "  ": Up/ Increase. In browsing status, press  to check the previous parameter. In 


setting window, press this button to check the next adjustable parameter or increase the value 
of current parameter. 
² "  “: Down/Decrease. In browsing window, press  to check the next parameter. In 
setting window, press this button to check the previous adjustable parameter or decrease the 
value of current parameter. 

² "Enter": Set/Confirm. In browsing window, press "Enter" to access setting window. In setting 
window, press this button to save parameters and return back to browsing window. 

² "Esc": Cancel/Manual reset. In setting window, press "Esc" to return to browsing window 
without saving the modified parameters. 

5.3 Parameters Browsing 

1) When power is on, the LCD is under browsing window and displays battery voltage: XX.X V; 

2) In  browsing  window,  LCD  will  circularly  display  the  following  parameters  by  pressing 
"  " button and "  " button.

7/11 
Wind/Solar Hybrid Controller  User Manual 

6. Monitoring Software (Optional) 

The monitoring software is specially developed for the controllers that we produced, the following 
are the part functions which can be realized via the software, more information please refer to our 
software user manual. 

a)  Remote monitoring and parameters configuration for different controller models. 

b)  Big database system capacity. 

c)  The controller can network according to RS482 bus, GPRS, Ethernet. 

d)  History data Inquiry. 

7. Technical Data 

Parameters  WWS06­48­B  WWS10­48­B  WWS10 


Rated Battery Voltage(V)(VB)  48  24  48 
Rated Wind Power (kW) PW  0.6  1  1  1 
Dimensions (L ×W ×H) (mm)  205×150×82  424×423×170 
Admittance Value 
Low  5/60  /  10/15  10/60 
(Factory Default) 
Voltage 
Wind Turbine Start Charge Voltage 
Charge  8  /  4  8 
(Factory Default) (V) 
Function 
Dimensions (L ×W ×H) (mm)  220×150×82  /  423×305×170 

Parameters  WWS20 

Rated Battery Voltage(V)(VB)  48  96  120  220  240

8/11 
Wind/Solar Hybrid Controller  User Manual 

Rated Wind Power(kW)PW  2 
Dimensions (L ×W ×H) (mm)  424×423×170 
Admittance Value 
10/30  10/150  10/150  5/300 
Low  (Factory Default) 
Voltage  Wind Turbine Start Charge Voltage 
8  20  20  40 
Charge  (Factory Default) (V) 
Function  Dimensions (L ×W ×H) (mm)  423×305×170 

Parameters  WWS30 

Rated Battery Voltage(V)(VB)  48  96  120  220  240 


Rated Wind Power(kW)PW  3 
Dimensions (L ×W ×H) (mm)  523×423×170 
Admittance Value 
Low  10/30  10/150  10/150  5/300  5/300 
(Factory Default) 
Voltage 
Wind Turbine Start Charge Voltage 
Charge  8  20  20  40  40 
(Factory Default) (V) 
Function 
Dimensions (L ×W ×H) (mm)  423×305×170 

Parameters  WWS50 
Rated Battery Voltage(V)(VB)  48  96  120  220  240 
Rated Wind Power(kW)PW  5 
Dimensions (L ×W ×H) (mm)  423×305×170 
Admittance Value 
Low  10/30  5/75  5/75  5/300  5/300 
(Factory Default) 
Voltage 
Wind Turbine Start Charge Voltage 
Charge  8  20  20  40  40 
(Factory Default) (V) 
Function 
Dimensions (L ×W ×H) (mm)  423×305×170 

Parameters  WWS100  WWS200 


Rated Battery Voltage(V)(VB)  120  220  240  220  240 
Rated Wind Power(kW)PW  10  10 
Dimensions (L ×W ×H) (mm)  423×305×170  423×305×170 
Admittance Value 
Low  5/75  5/300  5/300  5/300  5/300 
(Factory Default) 
Voltage 
Wind Turbine Start Charge Voltage 
Charge  20  40  40  40  40 
(Factory Default) (V) 
Function 
Dimensions (L ×W ×H) (mm)  423×305×170  423×305×170 

Note: The specific size to prevail in kind, / means no such product.

9/11 
Wind/Solar Hybrid Controller  User Manual 

Maximum Wind Turbine Input Power(W)  1.5PW 
Rated Solar Input Power(W)  PW×3/10 
Floating Charge Voltage(V)  VB  ×14.5/12 
Wind Turbine Brake Current(A)  PW/VB 
Dumpload Control Mode  PWM 
Display Mode  LCD 
Quiescent Current  ≤20mA 
Ambient Temperature & Humidity  ­20~+55℃/35~85%RH(Without Condensation) 
Communication Function (Optional)  RS232  、RS485、 RJ45、 GPRS (Optional) 
Temperature Compensation Function(Optional)  ­4mV/℃/2V ,–35℃~+80℃ , Precision:±1℃ 
In order to serve our customers better, our company can adjust parameter configuration according 
to customer’s requirement. 

8. Troubleshooting 
If your phenomenon is out of following descriptions or should you have any problems about these products, 
please contact manufacturer in time. 
Phenomenon  Troubleshooting 

The symbol  flashing,  without  Battery is over­voltage, check battery voltage, and whether the cables 


are well­connected or not, re­connect all components. 
charge or discharge 

a) Firstly, open the software “parameter”­“control”, please check if the 
setting is “BRAKE”. If yes, please cancel it. 
LCD display “BRAKE” all the time  b)Secondly,  Disconnect  wind  turbine,  battery  with  controller 
successively.  Reconnect  them  a  few  minutes  later,  then  check  if  it 
comes back to normal. 

9. Guarantee and Liability 
One year warranty is available for our product from the date of delivery. If the product is out of warranty or 
damaged by transportation, inappropriate operation, human factors, force majeure, no guarantee is made.

10/11 
Wind/Solar Hybrid Controller  User Manual 

Appendix 
Appendix I: Copper Wire Over Current Capacity 
(mm²)  Over current capability 
Wire Diameter  (A)  Wire Diameter 
(mm²)  Over current capability 
(A) 
4  ≤20  16  ≤90 
6  ≤30  25  ≤125 
10  ≤50 
AppendixⅡ : Dump load Box Dimension 

Product No.  Dumpload box Dimension (L ×W ×H)(mm) 

410×230×175  (24V System) 
WWS10 
300×190×120  (48V System) 
WWS20  410×430×175 
WWS30  540×430×175 
WWS50  770×390×180 
WWS100  520×430×675 
WWS200  680×420×675 
Note: The specific size to prevail in kind.