44000 Series EI 30-5 (0.
6 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals 5
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 40 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE TEMP.
115 VAC 230 VAC V mA V ºC
44025 44013 6 100 9.94 70
44026 44014 9 66 14.95 70
44027 44015 12 50 19.9 70
44028 44016 15 40 24.9 70
44029 44017 18 33 29.9 70
44030 44018 24 25 39.8 70
44031 44019 2x6 2 x 50 2 x 9.94 70
44032 44020 2x9 2 x 33 2 x 14.95 70
44033 44021 2 x 12 2 x 25 2 x 19.9 70
44034 44022* 2 x 15 2 x 20 2 x 24.9 70
44035 44023* 2 x 18 2 x 17 2 x 29.9 70
44036 44024* 2 x 24 2 x 12 2 x 39.8 70
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 30-10.5 (1 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 70 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE TEMP.
115 VAC 230 VAC V mA V ºC
44061 44049 6 167 8.6 70
44062 44050 9 111 12.9 70
44063 44051 12 83 17.2 70
44064 44052 15 67 21.6 70
44065 44053 18 56 25.9 70
44066 44054 24 42 37.9 70
44067 44055 2x6 2 x 83 2 x 8.6 70
44068 44056 2x9 2 x 56 2 x 12.9 70
44069 44057 2 x 12 2 x 42 2 x 19 70
44070 44058 2 x 15 2 x 33 2 x 23.6 70
44071 44059 2 x 18 2 x 28 2 x 24.9 70
44072 44060* 2 x 24 2 x 21 2 x 37.9 70
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 30-12.5 (1.5 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 80 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE TEMP.
115 VAC 230 VAC V mA V ºC
44097 44085 6 250 9.7 70
44098 44086 9 167 14.5 70
44099 44087 12 125 19.3 70
44100 44088 15 100 24.2 70
44101 44089 18 83 29.8 70
44102 44090 24 63 38.6 70
44103 44091 2x6 2 x 125 2 x 9.7 70
44104 44092 2x9 2 x 83 2 x 15 70
44105 44093 2 x 12 2 x 63 2 x 19.3 70
44106 44094 2 x 15 2 x 50 2 x 24.2 70
44107 44095* 2 x 18 2 x 42 2 x 29 70
44108 44096* 2 x 24 2 x 31 2 x 38.6 70
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 30-15.5 (2 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 100 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE TEMP.
115 VAC 230 VAC V mA V ºC
44133 44121 6 333 10.4 70
44134 44122 9 222 15.5 70
44135 44123 12 167 20.7 70
44136 44124 15 133 25.8 70
44137 44125 18 111 30.8 70
44138 44126 24 83 41.4 70
44139 44127 2x6 2 x 167 2 x 10.4 70
44140 44128 2x9 2 x 111 2 x 15.4 70
44141 44129 2 x 12 2 x 83 2 x 20.7 70
44142 44130 2 x 15 2 x 67 2 x 25.8 70
44143 44131* 2 x 18 2 x 56 2 x 30.8 70
44144 44132* 2 x 24 2 x 42 2 x 41.4 70
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 30-18 (2.3 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 110 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE TEMP.
115 VAC 230 VAC V mA V ºC
44169 44157 6 383 10.5 70
44170 44158 9 256 15.7 70
44171 44159 12 192 21 70
44172 44160 15 153 25.9 70
44173 44161 18 128 31.4 70
44174 44162 24 96 41.9 70
44175 44163 2x6 2 x 192 2 x 10.5 70
44176 44164 2x9 2 x 128 2 x 15.7 70
44177 44165 2 x 12 2x 96 2 x 21 70
44178 44166 2 x 15 2 x 77 2 x 25.9 70
44179 44167* 2 x 18 2 x 64 2 x 31.4 70
44180 44168* 2 x 24 2 x 48 2 x 41.9 70
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 38-13.6 (3.2 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 150 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD SEC. AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE PROTECTION TEMP.
115 VAC 230 VAC V mA V mA ºC
44205 44193 6 533 8 630 70
44206 44194 9 356 12 400 70
44207 44195 12 267 16 315 70
44208 44196 15 213 20 250 70
44209 44197 18 178 24.1 200 70
44210 44198 24 133 32.1 160 70
44211 44199 2x6 2 x 267 2x8 315 70
44212 44200 2x9 2 x 178 2 x 12 200 70
44213 44201 2 x 12 2 x 133 2 x 16 160 70
44214 44202 2 x 15 2 x 107 2 x 20 125 70
44215 44203 2 x 18 2 x 89 2 x 24 100 70
44216 44204* 2 x 24 2 x 67 2 x 32.1 80 70
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 42-14.8 (5 VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 200 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD SEC. AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE PROTECTION TEMP.
115 VAC 230 VAC V mA V mA ºC
44241 44229 6 833 8.4 800 50
44242 44230 9 556 12.6 630 50
44243 44231 12 417 16.9 400 50
44244 44232 15 333 21 315 50
44245 44233 18 278 25.3 315 50
44246 44234 24 208 33.7 200 50
44247 44235 2x6 2 x 417 2 x 8.4 400 50
44248 44236 2x9 2 x 278 2 x 12.6 315 50
44249 44237 2 x 12 2 x 208 2 x 16.9 200 50
44250 44238 2 x 15 2 x 167 2 x 21 160 50
44251 44239 2 x 18 2 x 139 2 x 25.3 160 50
44252 44240* 2 x 24 2 x 104 2 x 33.7 100 50
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 48-16.8 (10VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 300 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER NO. ORDER NO. SEC. SEC. NO LOAD AMBIENT
115 VAC 230 VAC VOLTAGE CURRENT VOLTAGE TEMP.
Pri. Protection Pri. Protection
125 mA 63 mA V mA V ºC
44277 44265 6 1667 7.2 50
44278 44266 9 1111 10.8 50
44279 44267 12 833 14.4 50
44280 44268 15 667 18.1 50
44281 44269 18 556 21.6 50
44282 44270 24 417 28.9 50
44283 44271 2x6 2 x 833 2 x 7.2 50
44284 44272 2x9 2 x 556 2 x 10.8 50
44285 44273 2 x 12 2 x 417 2 x 14.4 50
44286 44274 2 x 15 2 x 333 2 x 18.1 50
44287 44275 2 x 18 2 x 278 2 x 21.6 50
44288 44276* 2 x 24 2 x 208 2 x 28.9 50
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 54-18.8 (16VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 400 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER ORDER SEC. SEC. NO LOAD SEC. AMBIENT
NUMBER NUMBER VOLTAGE CURRENT VOLTAGE PROTECTION TEMP.
115 VAC 230 VAC V mA V mA ºC
44313 44301 6 2667 7.4 2500 50
44314 44302 9 1778 11. 1 2000 50
44315 44303 12 1333 14.7 1250 50
44316 44304 15 1067 18.4 1000 50
44317 44305 18 889 22.1 1000 50
44318 44306 24 667 29.3 630 50
44319 44307 2x6 2 x 1333 2 x 7.4 1250 50
44320 44308 2x9 2 x 889 2 x 11.1 1000 50
44321 44309 2 x 12 2 x 667 2 x 14.7 630 50
44322 44310 2 x 15 2 x 533 2 x 18.4 500 50
44323 44311 2 x 18 2 x 444 2 x 22 500 50
44324 44312* 2 x 24 2 x 333 2 x 29.3 315 50
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 60-21 (22VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 550 grams
OUTLINE DIMENSIONS
Manufacturer's Mark & Approvals
Recommended layout for transformers with
1 secondary winding (allows for use of a
transformer with 2 secondary windings)
Recommended Drill Hole Diameter for Pins
ELECTRICAL SPECIFICATIONS
ORDER NO. ORDER NO. SEC. SEC. NO LOAD AMBIENT
115 VAC 230 VAC VOLTAGE CURRENT VOLTAGE TEMP.
Pri. Protection Pri. Protection
250 mA 125 mA V mA V ºC
44444 44432 6 3667 6.8 50
44445 44433 9 2444 10.3 50
44446 44434 12 1833 13.7 50
44447 44435 15 1467 17.1 50
44448 44436 18 1222 20.5 50
44449 44437 24 917 27.3 50
44450 44438 2x6 2 x 1833 2 x 6.8 50
44451 44439 2x9 2 x 1222 2 x 10.3 50
44452 44440 2 x 12 2 x 917 2 x 13.7 50
44453 44441 2 x 15 2 x 733 2 x 17.1 50
44454 44442 2 x 18 2 x 611 2 x 20.5 50
44455 44443* 2 x 24 2 x 458 2 x 27.3 50
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]44000 Series EI 66-23 (30VA)
Sealed Power Transformer
FEATURES
• UL and VDE Approvals
• Vacuum Filled
• Split Bobbin Design
• Self-Extinguishing Plastics UL94V-O
• Dielectric Strength 4200Vrms
• Inherently energy limited
• Resin Class B IEC 85 (20,000 h Testing to IEC 216)
• Conforms to EN 60742
• 100% Production Tested
• Weight: 700 grams
OUTLINE DIMENSIONS
ELECTRICAL SPECIFICATIONS
ORDER NO. ORDER NO. SEC. SEC. NO LOAD AMBIENT
115 VAC 230 VAC VOLTAGE CURRENT VOLTAGE TEMP.
Pri. Protection Pri. Protection
315 mA 160 mA V mA V ºC
44385 44373 6 5000 6.9 50
44386 44374 9 3333 10.3 50
44387 44375 12 2500 13.8 50
44388 44376 15 2000 17.2 50
44389 44377 18 1667 20.8 50
44390 44378 24 1250 27.7 50
44391 44379 2x6 2 x 2500 2 x 6.9 50
44392 44380 2x9 2 x 1667 2 x 10.3 50
44393 44381 2 x 12 2 x 1250 2 x 13.8 50
44394 44382 2 x 15 2 x 1000 2 x 17.2 50
44395 44383 2 x 18 2 x 833 2 x 20.8 50
44396 44384* 2 x 24 2 x 625 2 x 27.7 50
NOTE: Circuit isolation protection is provided per EN 60742
* Limited Approval Ratings
ZETTLER Magnetics, Inc. The Power to Transform
75 COLUMBIA o ALISO VIEJO, CA 92656 o PHONE 949-360-5838 o FAX 949-360-5839
o WEB SITE: http://www.zettlermagnetics.com o E-MAIL:
[email protected]