Absolute and Gauge Pressure Cerabar PMP71

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Products Solutions Services

Absolute and
gauge pressure
Cerabar PMP71
Digital pressure transmitter with welded
metal sensor for measurement in gases, steam
or liquids

F L E X Benefits:
• Best accuracy, reproducibility and long-term stability
• Highest safety due to gas tight feedthrough with capabilities up to
SIL2/3, certified to IEC 61508
• Easy menu-guided commissioning via local display, 4 to 20mA with
HART, PROFIBUS PA, FOUNDATION Fieldbus
• HistoROM data management concept for fast and easy commissioning,
maintenance and diagnostics
• Overload-resistant and function-monitored from the measuring cell to
the electronics
• Available with mounted manifolds: always fit, always tested for leaks
• Seamless and independent system integration (HART/PA/FF)

More information and current pricing: Specs at a glance


www.us.endress.com/PMP71 • Accuracy Standard: 0.05% Platinum: up to 0.025%
• Process temperature -40°C...125°C (-40°F...257°F)
• Pressure measuring range 100mbar...700bar
(1.5psi...10.500psi)
• Main wetted parts Alloy C276 316L Rhodium
• Material process membrane 316L, AlloyC, Rhodium> Gold

Field of application: The Cerabar PMP71 digital pressure transmitter


with metallic membrane is typically used in process applications for
pressure, level, volume or mass measurement in liquids or gases. PMP71
is designed for high pressure applications up to 700bar. Quick Setup with
freely adjustable measuring range without pressure specification.
Designed according to IEC 61508 for use in SIL2/3 safety systems and
Cerabar S PMP71

available with MID Parts Certificate suitable for custody transfer


applications.

Features and specifications

Continuous / Liquids Measuring principle


Absolute and gauge pressure

Characteristic / Application
Digital transmitter with piezoresistive sensor and welded metallic
membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier

Specialities
diagnostic functionalities
different languages in software

Supply / Communication
4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC

Accuracy
Standard: 0.05%
Platinum: up to 0.025%

Long term stability


0,05% of URL/year

Ambient temperature
-50°C...85°C
(-58°F...185°F)

2 Endress+Hauser
Cerabar S PMP71

Continuous / Liquids Process temperature


-40°C...125°C
(-40°F...257°F)

Process pressure absolute / max. overpressure limit


1050bar (15,750psi)

Pressure measuring range


100mbar...700bar
(1.5psi...10.500psi)

Main wetted parts


Alloy C276
316L
Rhodium

Process connection
Threads
Flanges (DIN, ASME, ...) with flush membrane

Max. measurement distance


7000m (22.966ft) H2O

Communication
4...20 mA HART
1- 5V DC Low Power
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

Safety approvals
SIL

Design approvals
EN 10204-3.1
NACE MR0175, MR0103

3 Endress+Hauser
Cerabar S PMP71

Continuous / Liquids Marine approval


GL/ ABS

Drinking water approvals


NSF

Options
HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing

Successor
PMP71B

Application limits
Measuring cell: Metal
welded
If pressurized, possibly
use differential pressure
meas-urement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure

Pressure Measuring principle


Absolute and gauge pressure

Characteristic
Digital transmitter with piezoresistive sensor and welded metallic
membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functionsSecondary process barrier

4 Endress+Hauser
Cerabar S PMP71

Pressure Supply voltage


4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy
Standard: 0.05%
Platinum: up to 0.025%

Long term stability


0.05 % of URL/ year
0.07 % of URL/ 5 years
0.1 % of URL/ 10 years

Process temperature
-40°C...125°C
(-40°F...257°F)

Ambient temperature
-50°C...85°C
(-58°F...185°F)

Measuring cell
100 mbar...700 bar
(1.5 psi...10.500 psi)
relative/ absolute

Smallest calibratable span


5 mbar (0.075 psi)

Vacuum resistance
10 mbar (0.15 psi)

Max. Turn down


100:1

5 Endress+Hauser
Cerabar S PMP71

Pressure Max. overpressure limit


1050 bar (15.750 psi)

Process connection
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2
Flange:
DN25...DN80,
ASME 1"...4",
JIS 10K...20K

Material process membrane


316L, AlloyC,
Rhodium> Gold

Material gasket
None, measuring cell welded

Fill fluid
Silicone oil,
Inert oil

Material housing
Die-cast aluminum,
AISI 316L

Communication
4...20 mA HART
1- 5V DC Low Power
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

Safety approvals
SIL

6 Endress+Hauser
Cerabar S PMP71

Pressure Design approvals


EN10204-3.1
NACE MR0175

Marine approvals
GL/ABS

Drinking water approvals


NSF

Specialities
Diagnostic functions

Successor
PMP71B

More information www.us.endress.com/PMP71

Endress+Hauser USA addresses.endress.com


United States [email protected]