Modtool Instructions: Auckland Head Office
Modtool Instructions: Auckland Head Office
When ModTool starts it creates a couple of folders under the location it was started from. The “LogFiles”
folder contains log files that record the activity of ModTool. The “ModWeighLogFiles” folder is created
when the “Save System Logs” button is used and holds the logs from the ModWeigh units.
To remove ModTool simply delete the exe file and these two folders if they exist.
To download the ModTool exe file open the website www.emc.co.nz and click the Downloads button
near the top right. Click ModWeigh near the center of the page. This opens the ModWeigh downloads
area.
Double click Software Tools & Updates and then ModTool - for MT3 configuration. From here you
can double click the ModTool6.XXrXX.exe file to download it.
Important: Please note the following caveats when downloading and running ModTool.
Downloading
Depending on which web browser you are using you may need to specify that the file is safe to
download.
In Google Chrome for example you will need to click Download after which chrome may issue a warning
saying “ModTool6.XXrXX.exe is not commonly downloaded and may be dangerous”.
You will need to click the small button next to Discard and click Keep, as in the following screen shot.
When you double click the ModTool exe file for the first time you will get the following warning from
Windows.
You will need to click More Info to run ModTool. This warning only appears the first time after you
download the exe file.
A second screen now appears where you can click Run anyway.
The first step is to connect to the ModWeigh unit. Depending on which type of ModWeigh unit you are
using there are a couple of options.
● A standard USB micro B cable can be used to connect your PC/laptop to the USB port of the
ModWeigh unit. If you are using Windows 10 then it automatically installs the correct drivers. If
you are using Windows 7 or Windows 8 then you will need to download and install the correct
USB drivers from the ModWeigh download area of our website at www.emc.co.nz.
● A MAC cable and MAD adapter can be used with a standard USB to RS232 Serial adapter to
connect the PC/laptop to the COM1 port of the ModWeigh unit.
Once the ModWeigh unit is connected the Connect button changes to Disconnect and the list of
ModWeigh units is shown in the left hand pane.
To select a unit click on it and information about that unit will be displayed on the right hand side.
There are two operations that can be carried out on all ModWeigh units.
The Update All button - clicking this button will update the software in all units. This will take a long time
and the units will be restarted at the end of the process.
The Save System Logs button - clicking this button saves the system logs from all units into a folder
called “ModWeighLogFiles”. This will take a long time.
The product information includes the product type, software version, serial number and card number. To
the right of this information is the product type description, in this case the ModWeigh unit is a Weight
Indicator.
The weight (AI1) and output current (AO1) are displayed next and update once per second.
Initially the calibration is locked. The calibration fields are greyed out to show this.
To unlock the calibration click the locked checkbox. The calibration will then become unlocked and the
fields can then be edited.
weight capacity - sets the weight capacity. This is equivalent to menu quick key Q2121 in a ModWeigh
display.
AI1 response time - use the up/down control to adjust this. This is equivalent to menu quick key
Q22311 in a ModWeigh display.
zero - set this to 0 and press the Enter key to zero the weighing system. This is equivalent to menu quick
key Q22321 in a ModWeigh display.
span - apply a known weight and press the Enter key to span the weighing system. This is equivalent to
menu quick key Q22322 in a ModWeigh display.
limit - OUT9 is driven on when the weight is below the value entered in this field. This is equivalent to
menu quick key Q23524 in a ModWeigh display. Please note that this field is only shown for a 61 Weight
Indicator product type.
The Save Settings… button - clicking this button allows you to save the settings of the selected
ModWeigh unit to a file on your computer. You can choose to either save the normal setup or just the
altered setup (only those settings changed from the default). The “...” button allows you to select the
folder where the settings file will be saved, by default the file is saved in the same folder that ModTool is
started from.
The Load Settings… button - clicking this button allows you to load the settings back into the selected
ModWeigh unit using a file on your computer. You can choose what to load into the unit from: settings,
macros, memory storage or loadcell calibration. The “...” button allows you to select the file where the
settings will be loaded from.